This document provides special packaging instructions for a hydraulic manifold part number 12273563. The instructions specify how to clean, dry, pack, and preserve the item using various military standards for preservation, cleaning, drying, packing, and marking. The item is to be packed individually in a MIL-DTL-117, Type I, Class E bag that is then cushioned using A-A-59135, Class 1, Grade A material and secured in an A-A-59736, Type IV, Style B container. Plugs are to be installed in the inlet, outlet, and other ports of the item using specified NAS plugs prior to packaging. The container is identified as an acceptable Level B shipping container and if over 125 pounds of items are shipped to one destination, the exterior packs are to be palletized. Inspection of the preservation, unit pack, and packing is to be in accordance with the specified military standards and container specification.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment SP3300-23-Q-0220-P0001.pdf | ||
| _AMP12281256.pdf | ||
| _AMP9376467 - Valve Assembly Turret.pdf | ||
| _AK16008876.pdf | ||
| _AM12285300.pdf | ||
| _AK16686318 9376467-4 VALVE ASSEMBLY TURRET.pdf | ||
| _AKD4418137.pdf | ||
| _AMP12925899 Computer Electronic Unit - 013720720.pdf | ||
| Tab 10 - CSS SP3300-23-Q-0220.pdf | ||
| _AM12972530 2 EyeSafe Laser Rangefinder - 014979758.pdf | ||
| _AK10743788.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 1 Pages
SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188
-CC
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12273563 (19207) MANIFOLD, HYDRAULIC 19207 AK11301980
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
4730-01-130-1980 12-2-2005 D
7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)
1 EA NONE 23.6 3.545 22.5 X 16.5 X 16.5
12. MILITARY PRESERVATION (METHOD) 18.
STEPS
19.
REQ’D
20.
DESCRIPTION
MIL-STD-2073-1D, METHOD 41 1A 6 PLUGS: NAS OR EQUIVALENT, SEE NOTE A.
13. CLEANING
MIL-STD-2073-1D 2B 1 CUSHIONING: A-A-59135, CLASS 1, GRADE A,
14. DRYING SIZE: 39 X 21 X 1/4.
MIL-STD-2073-1D
3C 1 BAG: MIL-DTL-117, TYPE I, CLASS E, SIZE: 20 X 23.
15. PACKING
a. LEVEL A 4 1 CONTAINER: A-A-59736, TYPE IV, STYLE B, MIL-STD-2073-1D AND NOTE D SIZE: 22 X 16 X 16, NSN: 8115-01-006-7257.
b. LEVEL B
MIL-STD-2073-1D AND NOTE D
16. MARKING
MIL-STD-129
17. NOTES / DRAWING
A. PLACE PLUGS IN INLET AND OUTLET PORTS. IF ITEM IS RECEIVED WITH PLUGS INSTALLED THEN THIS
STEP MAY BE ELIMINATED. INSTALL PLUGS AS FOLLOWS:
• NAS833 OR EQUIVALENT, QTY. 3, PLUG PORTS R1, P3, AND P2
• NAS834 OR EQUIVALENT, QTY. 2, PLUG PORTS P1, AND R2
• NAS847 OR EQUIVALENT, QTY. 1, PLUG AIR BLEEDER PORT
B. SECURE WITH TAPE.
C. CLOSE BAG BY HEAT SEALING.
D. LEVEL A: PACKING SHALL BE ACCOMPLISHED USING A CLEATED PLYWOOD BOX, CONFORMING TO
ASTM-D6251, TYPE III, CLASS 1.
LEVEL B: THE UNIT CONTAINER IS AN ACCEPTABLE LEVEL B SHIPPING CONTAINER.
FOR BOTH LEVEL A AND LEVEL B, WHEN THE TOTAL QUANTITY TO BE SHIPPED TO THE SAME
DESTINATION EXCEEDS 125 POUNDS, EXTERIOR PACKS WITHOUT SKIDS SHALL BE PALLETIZED.
MIL-HDBK-774 MAY BE USED FOR GUIDANCE.
E. INSPECT THE PRESERVATION, THE UNIT PACK AND THE PACKING IN ACCORDANCE WITH
MIL-STD-2073-1D AND THE APPLICABLE CONTAINER SPECIFICATION.