Lighting Spreadsheet.xls

XLS spreadsheet 14 MB Posted

Attached to
Replacement Lighting, Canyon WC, Kelly WC & Pierce WC
Solicitation number
AG-82B1-S-10-0294
Issued by

About this file

Lighting Spreadsheet

View the file

Other files

File Type Posted
Canyonsanscost.xls XLS spreadsheet
AG-82B1-S-10-0294 Amendment 0001.pdf PDF
Piercesanscost.xls XLS spreadsheet
AG-82B1-S-10-0294 body.pdf PDF
AG-82B1-S-10-0294 SF 18.pdf PDF
Expierence Questionnaire.doc DOC document
AG-82B1-S-10-0294 Drawing.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Kelly Forks WC IMPORTANT NOTE: All project information should be input on this page. Input/select information into cells that have a blue color font.

Leave cells with black or red color fonts alone. See Example "Site Audit" Sheet for examples. Use the View menu and Zoom feature to magnify this page.

Existing Building(s) Lighting Spreadsheet Tool - Updated Jan 21, 2010
Project Name:KELLY FORKS WORK CENTERUtility Invoice Number:Utility Invoice Number
Dominant Building Type:Serving Utility:Utility Name
Space Heat Fuel Source:Utility Contact Name:Utility Contact Name
Customer NameCLEARWATER FSUtility Phone Number:Utility Phone
Contact Name:Energy Rate ($/kWh) & estimated $ savings/yr:$0.05CUSTOMER SIMPLE PAYBACK:
Facility Street Address:Demand Rate ($/kW) & estimated $ savings/yr:$0.000.0yearsThis Section for Calculating PV of Periodic Lamp Replacement Cost
Facility City:Audit Prepared By (Name and Phone Number):Auditor InfoUses a user-defined function called dfuncPV
Facility State & Zip:Trade Ally/Contractor Name:Trade Ally NameProgram Parameters
Building & Account Numberacct. #Date & Time (fills in automatically):3/24/10 7:29 AM
Discount Rate=dfuncPV(Number,OperatingHours,AverageLife,Cost,Labor,Labor_Rate,Discount_Rate,Measure_Life)
Summary Table >>Total Existing Kilowatt-HoursTotal Proposed Kilowatt-HoursTotal Estimated Annual kWh Site Savings (unadjusted)Annual Hours (weighted)Kilowatt-Hour Reduction PercentageTotal kWh Site Savings (adjusted for HVAC)Measure Life
19,2034,83514,36865275%Labor Rate
Project Cost>>Lesser of Credit/Reimbursement -or- 0% Project Cost>>Project Cost Cap
LocationExisting Lamp/Ballast CombinationNotes:Proposed Lamp/Ballast CombinationSummary/Design InfoContractor CostBPA Estimated Material and Labor Costs (Preliminary Only)ExistingProposed
For instance; building and room nameAnnual Operat HoursExisting Lamp/BallastQ'tyWatts EachMean Lumens EachTotal WattsTotal kWhFor high performance lamps and ballasts on the CEE list, include model numbers and CEE list date. Field notes on fixtures, mounting height, difficulty, approvals, etc…Annual Operat HoursProposed Lamp/BallastQ'tyWatts EachMean Lumens EachTotal WattsTotal kWhAnnual kWh SavingskWh ReductionLight Level ChangeCode$ per unitTotal $Installed Cost Per UnitNumber of UnitsTotalNotesCutsheetsRated Average Lamp Life (hours/lamp for ballast type and start frequency)Lamp Cost ($/lamp)Lamp Change Labor (hours/lamp)PV Lamp Periodic ReplacementRated Average Lamp Life (hours/lamp for ballast type and start frequency)Lamp Cost ($/lamp)Lamp Change Labor (hours/lamp)PV Lamp Periodic ReplacementNet PV Lamp Periodic Replacement (Costs(+) or Savings(-))
1Rental Cabin (1045)000$00$0
2General Living Room500Incandescent, 1-60 Watt Typical Bulb1360800780390500Screw-In CFL, 14 Watt13147201829129977%-10%13$0.00Screw in51,2000.050.0010,0000.090.00
3Bathroom500Incandescent, 1-60 Watt Typical Bulb560800300150500Screw-In CFL, 14 Watt514720703511577%-10%5$0.00Screw in51,2000.050.0010,0000.090.00
4Bedroom500Incandescent, 1-60 Watt Typical Bulb660800360180500Screw-In CFL, 14 Watt614720844213877%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
5Generator Shed (1819)000$00$0
6General400Incandescent, 1-200 Watt Bulb32003,154600240400Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (2-F32T8)3554,3721656617473%39%3$0.00Replace with new fluorescent fixture1,2,47500.090.0024,0000.090.00
7Main Office (2006)
8Office 1 (left of door)1,000T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts41769,7367047041,000High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.4484,59419219251273%-53%4$0.00Replace with new fixture1,2,420,0000.090.0030,0000.090.00
9Office 21,000T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts41769,7367047041,000High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.4484,59419219251273%-53%4$0.00Replace with new fixture1,2,420,0000.090.0030,0000.090.00
10Hallway1,000T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast1884,86888881,000High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448484045%-6%1$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
11Hallway1,000Incandescent, 2-40 Watt Typical Bulbs5808054004001,000Screw-In CFL, 14 Watt101472014014026065%79%10$0.00Screw in51,5000.050.0010,0000.090.00
12Mens Restroom500T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast1884,8688844500High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448242045%-6%1$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
13Mens Restroom500Incandescent, 1-60 Watt Typical Bulb1608006030500Screw-In CFL, 14 Watt1147201472377%-10%1$0.00Screw in51,2000.050.0010,0000.090.00
14Womens Restroom500T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast1884,8688844500High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448242045%-6%1$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
15Womens Restroom500Incandescent, 1-60 Watt Typical Bulb1608006030500Screw-In CFL, 14 Watt1147201472377%-10%1$0.00Screw in51,2000.050.0010,0000.090.00
16Storage/computer net.500T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast1884,8688844500High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448242045%-6%1$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
17Office 31,000T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts41769,7367047041,000High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.4484,59419219251273%-53%4$0.00Replace with new fixture1,2,420,0000.090.0030,0000.090.00
18Main Reception1,000T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts81769,7361,4081,4081,000High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.8484,5943843841,02473%-53%8$0.00Replace with new fixture1,2,420,0000.090.0030,0000.090.00
19Office 41,000T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts21769,7363523521,000High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.2484,594969625673%-53%2$0.00Replace with new fixture1,2,420,0000.090.0030,0000.090.00
20ExteriorMotion Sensor Fixture1No recommendation (leave fixture as-is)11
21Basement300Incandescent, 1-300 Watt Bulb13004,80230090300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448147684%-4%1$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
22Basement300Incandescent, 1-100 Watt Typical Bulb11001,54810030300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448141652%197%1$0.00New Fixture Standardize to new1,2,41,0000.050.0030,0000.090.00
23Basement300Incandescent, 75 Watt Reflector Lamp1758017523300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,5944814836%474%1$0.00New Fixture Standardize to new1,2,42,0000.090.0030,0000.090.00
24Basement300Incandescent, 1-75 Watt Typical Bulb1751,0867523300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,5944814836%323%1$0.00New Fixture Standardize to new1,2,41,2000.050.0030,0000.090.00
25Basement300T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts181769,7363,168950300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.18484,59486425969173%-53%18$0.00New Fixture Standardize to new1,2,420,0000.090.0030,0000.090.00
26Basement300Incandescent, 1-100 Watt Typical Bulb31001,54830090300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.3484,594144434752%197%3$0.00Screw in51,0000.050.0030,0000.090.00
27Upper Mezz300Incandescent, 1-300 Watt Bulb33004,802900270300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.3484,5941444322784%-4%3$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
28Caged Area300T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast2884,86817653300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.2484,59496292445%-6%2$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
29Shop
30General500Incandescent, 1-500 Watt Bulb45008,8112,0001,000500High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.4484,5941929690490%-48%4$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
31General500Incandescent, 1-300 Watt Bulb33004,802900450500High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.3484,5941447237884%-4%3$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
32General500Incandescent, 1-200 Watt Bulb22003,154400200500High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.2484,594964815276%46%2$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
33Carpenter Shop (2319)
34General800Incandescent, 1-500 Watt Bulb45008,8112,0001,600800High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.4484,5941921541,44690%-48%4$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
35General800Incandescent, 1-200 Watt Bulb52003,1541,000800800High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.5484,59424019260876%46%5$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
36Restroom300Incandescent, 1-60 Watt Typical Bulb1608006018300Screw-In CFL, 14 Watt1147201441477%-10%1$0.00Screw in51,2000.050.0010,0000.090.00
37Tree Cooler (1510)
38General300Incandescent, 1-300 Watt Bulb13004,80230090300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.1484,59448147684%-4%1$0.00New Fixture Standardize to new1,2,47500.090.0030,0000.090.00
39General300T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast6884,868528158300High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.6484,594288867245%-6%6$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
40Trailer (1336, 1337, 1338, 1349. Quantities assume all trailers)
41Bedrooms (3 lamps/ Rm)800Incandescent, 1-60 Watt Typical Bulb36608002,1601,728800Screw-In CFL, 14 Watt36147205044031,32577%-10%36$0.00Screw in51,2000.050.0010,0000.090.00
42Living Room800Incandescent, 1-60 Watt Typical Bulb24608001,4401,152800Screw-In CFL, 14 Watt241472033626988377%-10%24$0.00Screw in51,2000.050.0010,0000.090.00
43Kitchen (not sure, verify lite type)800T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast16884,8681,4081,126800High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.16484,59476861451245%-6%16$0.002L Reballast LBF1,220,0000.090.0030,0000.090.00
44Exterior500Incandescent, 1-60 Watt Typical Bulb860800480240500Screw-In CFL, 14 Watt8147201125618477%-10%8$0.00Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures6c
45Houses (1017, 1018, 1019)Assume 3 identical Houses (Quantities assume all houses)
46Bedroom 11,000Incandescent, 2-60 Watt Typical Bulbs31201,6003603601,000Screw-In CFL, 14 Watt614720848427677%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
47Bedroom 1 (Assume Table Lamp)500Incandescent, 2-60 Watt Typical Bulbs31201,600360180500Screw-In CFL, 14 Watt614720844213877%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
48Bedroom 2500Incandescent, 2-60 Watt Typical Bulbs31201,600360180500Screw-In CFL, 14 Watt614720844213877%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
49Bedroom 2 (Assume Table Lamp)500Incandescent, 2-60 Watt Typical Bulbs31201,600360180500Screw-In CFL, 14 Watt614720844213877%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
50Bedroom 31,000Incandescent, 2-60 Watt Typical Bulbs31201,6003603601,000Screw-In CFL, 14 Watt614720848427677%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
51Bedroom 3 (Assume Table Lamp)500Incandescent, 2-60 Watt Typical Bulbs31201,600360180500Screw-In CFL, 14 Watt614720844213877%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
52Kitchen1,000Incandescent, 2-60 Watt Typical Bulbs61201,6007207201,000Screw-In CFL, 14 Watt121472016816855277%-10%12$0.00Screw in51,2000.050.0010,0000.090.00
53Kitchen1,000Incandescent, 1-60 Watt Typical Bulb6608003603601,000Screw-In CFL, 14 Watt614720848427677%-10%6$0.00Screw in51,2000.050.0010,0000.090.00
54Living Room (Portable Lamps?)1,000Incandescent, 2-60 Watt Typical Bulbs61201,6007207201,000Screw-In CFL, 14 Watt121472016816855277%-10%12$0.00Screw in51,2000.050.0010,0000.090.00
55Garage300Incandescent, 1-100 Watt Typical Bulb61001,548600180300Screw-In CFL, 18 Watt6189781083214882%-37%6$0.00Screw in51,0000.050.0010,0000.090.00
56Exterior500Incandescent, 1-60 Watt Typical Bulb660800360180500Screw-In CFL, 14 Watt614720844213877%-10%6$0.00Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures6c
TOTALS>>>24929,47419,2032847,4074,83514,368$0$0goes to ProjectSave
Adding and Deleting Rows:

To Add Rows: 1) move the curser to the number box on the left hand side of the row you want to add and left-click to highlight the row, 2) right-click in the highlighted area and choose "copy", 3) right-click again on the row number and choose "insert copied cells".

To Delete Rows: 1) move the curser to the number box on the left hand side of the row you want to add and left-click to highlight the row, 2) right-click in the highlighted area and choose "delete".

P.S. The print area on this worksheet is set so the note box does not print. The print area is set on the other worksheets as well.

&L&F&R&D, &T Add A Row Automatically copies the Existing Lamp/Ballast Combination Quantity unless user types in a changed value. For instance, type in a different value if one or more fixtures are removed or added.

Mean lamp(s) light output per existing luminaire. Does not include luminaire efficiency. Automatically draws from the Data Existing tab column D of this workbook.

Quantity of existing luminaires. User input value.

Existing watts per luminaire. Automatically draws from the Data Existing tab column C of this workbook.

These are drop-down boxes. Make a selection and it will automatically draw from the Data Existing tab column B of this workbook and populate column F, G, H, I, and J of this spreadsheet.

Estimated annual operating hours of each lighting measure (not the building). This value is user calculated and input.

Area of building, room number, location, office name, etc.. Be specific enough that someone unfamiliar with the building can easily find the room or area. You can group exact same rooms together if they have the same hours of operation and are closely located.

Must be 25% or greater in order to receive a reimbursement or credit. Font turns red if less than 25%.

Proposed watts per luminaire. Automatically drawn from the Data Proposed tab column C of this workbook.

Mean lamp(s) light output per proposed luminaire. Does not include luminaire efficiency. Automatically drawn from the Data Proposed tab column D of this workbook.

Spreadsheet automatically calculates this value. It is a per room per measure calculation.

These are drop-down boxes. Make a selection and it will automatically draw from the Data Proposed tab column B of this workbook and populate column N, O, P, and Q of this spreadsheet.

Weighted average of existing lighting system hours of operation per year.

Calculated from column Q of this worksheet. Column Q is a hidden column.

Calculated from column I of this worksheet. Column I is a hidden column.

Automatically copies the Existing Annual Operating Hours of the measure unless user types in a changed value. For instance, type in a different value if an occupancy sensor is installed.

Total Project Estimated Annual kWh savings at the site. This value is unadjusted for interactions and busbar savings. This cell sums up values in column R.

OPTIONAL: This value should be the most representative utility demand rate in dollars per kilowatt per month. You may have to average seasonal demand rates.

This cell automatically calculates the estimated dollar savings per year (12 months) associated with kW or Demand savings. This number is added to the energy savings value and put into the estimated dollar savings cell in the letter tab of this workbook.

REQUIRED: This value should be the most representative energy rate in dollars per kilowatt-hour. Usually the highest block rate in the utilities rate structure. May have to average seasonal energy rates.

This is the Reimbursement or Credit amount. Based on the total rebate amounts or 70% of project cost whichever is less. Only gives a Credit if the kWh Reduction is at least 25%.

This value is taken from the Data Proposed tab column F.

This value is the multiplication of column M and column X of this spreadsheet. It is the total reimbursement or credit per measure.

Font is RED if Wattage Reduction is NOT between 20 and 50%. The value(s) below are only related to each measure.

Font is RED if Change in Light Level is NOT between -10% and +10%. Calculates total change in light output of lamp(s) only. Ignores luminaire efficiency. Use the below value(s) to determine how close you are to the existing light level.

Per measure summary info. Use this info to check yourself.

This value is only related to the lighting kilowatt-hour reduction affected by the installation. Does not depict total building kilowatt-hour reduction percentage.

Input the project cost into the cell to the right or use the contractor bid info form to the right of this page. Includes labor and materials from the installation contractors' invoices. Also, can include in-house labor costs. Direct installation labor costs only.

This value is taken from the Data Proposed tab column E.

CAA or CRC Reimbursement or Credit per unit and total per measure Charlie Grist:

Electric Savings including estimated interactive effects of lighting and HVAC Charlie Grist:

Select building type from list. If multiple building types are present consider separate audit sheets for separate buildings. Or select the type that most closely matches the primary areas of the building where proposed lighting measures occur.

This value is used to estimate interactive effects of lighting energy savings on HVAC.

Charlie Grist:

Select dominant space heat type from list. If multiple space heat types are present, consider separate audit sheets for separate buildings. Or select the type that most closely matches the primary areas of the building where proposed lighting measures occur.

This value is used to estimate interactive effects of lighting energy savings on HVAC.

Input building for this project This value takes into account the energy interaction between the lighting system and the HVAC system.

Input street address, city, and stare. Enter enough info to locate the facility.

CAA or CRC Reimbursement or Credit per unit and total per measure This value is the multiplication of column M and column X of this spreadsheet. It is the total reimbursement or credit per measure.

Automatically pulls from cell AC35 (the contractor bid worksheet), unless user manually enters a different number.

COTR

COTR Quick Check
Project Name0
Unique ID0
Project Cost$0.00
Annual Busbar Savings0kWh/year
Wattage Reduction0%
Total Reimbursement$0.00

CS#1a Lamp

CS#1b Lamp

CS#2 Ballast

CS#3a Refl Kit

CS#3b Refl Kit

CS#4 New Wrap

CS#5a CFL

CS#5b CFL

CS#6a Wallpack

CS#6b Wallpack

CS#6c Wallpack

CS#6d Spot

CS#6e Spot

CS#7 Exterior Pole

CS#8a_Occ Sen

CS#8b_Occ Sen

CS#8c_Occ Sen

CS#8d_Occ Sen

CS#8e_Occ Sen

CS#9 High Bay

CS#10a_Small Lamp fix

CS#10b_Small Lamp

CS#11_Exit

Data Existing

1234567891011121314151617181920
Updated January 9, 2009. This list is not meant to be complete, you can add equipment to this list.Default lamp life and cost data used for estimating life-cycle periodic replacement costs.
Description of Existing Lamp/Ballast CombinationInput WattsMean System LumensSuggested Upgrades / NotesRated Average Lamp Life (hours/lamp for RS ballast @ 12 hours/start)Lamp Cost ($/lamp)Lamp Change Labor (hours/lamp)
Describe existing lamp/ballast combination here<<Input a wattage and mean system lumens
=================================
EXIT SIGNS
=================================
Incandescent Exit Sign, 2-5 Watt Lamps102New LED Exit Sign10,000$2.310.1
Incandescent Exit Sign, 2-8 Watt Lamps162New LED Exit Sign10,000$2.310.1
Incandescent Exit Sign, 2-10 Watt Lamps202New LED Exit Sign10,000$2.310.1
Incandescent Exit Sign, 2-15 Watt Lamps302New LED Exit Sign10,000$2.310.1
Incandescent Exit Sign, 2-20 Watt Lamps402New LED Exit Sign10,000$2.310.1
Incandescent Exit Sign, 2-25 Watt Lamps502New LED Exit Sign10,000$2.310.1
Incandescent Exit Sign, 2-40 Watt Lamps802New LED Exit Sign10,000$2.310.1
=================================
T8 DE-LAMP
=================================
Standard 4' T8 2 lamp 32 Watt604932
Standard 4' T8 3 lamp 32 Watt906969
Standard 4' T8 4 lamp 32 Watt1149293
Standard 4' T8 6 lamp 32 Watt16215373
=================================
T12 FLUORESCENT (LAMPS UNDER 8')
=================================
T12 2' Fluorescent, 1-20 Watt Lamp, Magnetic Ballast24960T8 High Performance7,500$2.170.09
T12 3' Fluorescent, 1-30 Watt Lamp, Magnetic Ballast361630T8 High Performance18,000$3.290.09
T12 2'x2' Fluorescent, 1-40 Watt U-Tube Lamp, Magnetic Ballast482775T8 High Performance20,000$4.800.09
T12 2'x2' Fluorescent, 2-40 Watt U-Tube Lamps, Magnetic Ballast865550T8 High Performance20,000$4.800.09
T12 4' Fluorescent, 1-56 Watt HO Lamp, Magnetic Ballast664000T8 High Performance12,000$4.280.09
T12 4' Fluorescent, 2-56 Watt HO Lamps, Magnetic Ballast1328000T8 High Performance
----------------------------
T12 4' Fluorescent, 1-34 Watt ES Lamp, Energy Efficient Ballast431891T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast462434T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 1-34 Watt ES Lamp, Magnetic Ballast481934T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 1-40 Watt Lamp, Magnetic Ballast522434T8 High Performance20,000$1.120.09
----------------------------
T12 4' Fluorescent, 2-34 Watt ES Lamps, Energy Efficient Ballast723781T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 2-34 Watt ES Lamps, Magnetic Ballast823868T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast884868T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 2-40 Watt Lamps, Magnetic Ballast964868T8 High Performance20,000$1.120.09
----------------------------
T12 4' Fluorescent, 3-34 Watt ES Lamps, Energy Efficient Ballasts1165672T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 3-34 Watt ES Lamps, Magnetic Ballasts1305802T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 3-40 Watt Lamps, Energy Efficient Ballasts1347302T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 3-40 Watt Lamps, Magnetic Ballasts1487302T8 High Performance20,000$1.120.09
----------------------------
T12 4' Fluorescent, 4-34 Watt ES Lamps, Energy Efficient Ballasts1447562T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 4-34 Watt ES Lamps, Magnetic Ballasts1647736T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts1769736T8 High Performance20,000$1.120.09
T12 4' Fluorescent, 4-40 Watt Lamps, Magnetic Ballasts1929736T8 High Performance20,000$1.120.09
=================================
T12 FLUORESCENT (8' LAMPS)
=================================
T12 8' Fluorescent, 1-60 Watt Lamp, Magnetic Ballast834259T8 High Performance12,000$6.000.09
T12 8' Fluorescent, 1-75 Watt Lamp, Magnetic Ballast1005145T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 1-95 Watt HO ES Lamp, Magnetic Ballast1255729T8 High Performance12,000$7.630.09
T12 8' Fluorescent, 1-100W HO Lamp, Magnetic Ballast1406716T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 1-185 Watt VHO ES Lamp, Magnetic Ballast2008370T8 High Performance12,00012.580.09
T12 8' Fluorescent, 1-215 Watt VHO Lamp, Magnetic Ballast2309526T8 High Performance12,000$11.580.09
----------------------------
T12 8' Fluorescent, 2-60 Watt ES Lamps, Energy Efficient Ballast1238322T8 High Performance12,000$6.000.09
T12 8' Fluorescent, 2-60 Watt ES Lamps, Magnetic Ballast1388517T8 High Performance12,000$6.000.09
T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast15810181T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 2-75 Watt Lamps, Magnetic Ballast17310290T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 2-95 Watt HO ES Lamps, Magnetic Ballast22711458T8 High Performance12,000$7.630.09
T12 8' Fluorescent, 2-110 Watt HO Lamps, Energy Efficient Ballast23713432T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 2-110 Watt HO Lamps, Magnetic Ballast25213432T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 2-185 Watt VHO ES Lamps, Magnetic Ballast32516740T8 High Performance12,00012.580.09
T12 8' Fluorescent, 2-215 Watt VHO Lamps, Magnetic Ballast44019051T8 High Performance12,000$11.580.09
----------------------------
T12 8' Fluorescent, 3-60 Watt ES Lamps, Magnetic Ballasts22012776T8 High Performance12,000$6.000.09
T12 8' Fluorescent, 3-75 Watt Lamps, Magnetic Ballasts27415435T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 3-95 Watt HO ES Lamps, Magnetic Ballasts35217186T8 High Performance12,000$7.630.09
T12 8' Fluorescent, 3-110 Watt HO Lamps, Energy Efficient Ballasts39220148T8 High Performance12,000$7.020.09
----------------------------
T12 8' Fluorescent, 4-60 Watt ES Lamps, Energy Efficient Ballast24616643T8 High Performance12,000$6.000.09
T12 8' Fluorescent, 4-60 Watt ES Lamps, Magnetic Ballast27617035T8 High Performance12,000$6.000.09
T12 8' Fluorescent, 4-75 Watt Lamps, Energy Efficient Ballasts31620361T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 4-75 Watt Lamps, Magnetic Ballasts34620580T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 4-95 Watt HO ES Lamps, Energy Efficient Ballasts41622915T8 High Performance12,000$7.630.09
T12 8' Fluorescent, 4-95 Watt HO ES Lamps, Magnetic Ballasts45422915T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 4-110 Watt HO Lamps, Energy Efficient Ballasts47426864T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 4-110 Watt HO Lamps, Magnetic Ballasts50426864T8 High Performance12,000$7.020.09
T12 8' Fluorescent, 4-185 Watt VHO ES Lamps, Magnetic Ballasts65033480T8 High Performance12,00012.580.09
T12 8' Fluorescent, 4-215 Watt VHO Lamps, Magnetic Ballasts88038102T8 High Performance12,000$11.580.09
=================================
T12 FLUORESCENT (OTHER)
=================================
T12 Other Fluorescent, 1-20 Watt Lamp, Magnetic Ballast25944T8 High Performance9,000$2.170.09
T12 Other Fluorescent, 1-25 Watt ES Lamp, Magnetic Ballast421514T8 High Performance18,000$3.890.09
T12 Other Fluorescent, 1-30 Watt Lamp, Magnetic Ballast461791T8 High Performance18,000$3.290.09
T12 Other Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast482234T8 High Performance18,000$5.090.09
----------------------------
T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast501887T8 High Performance9,000$2.170.09
T12 Other Fluorescent, 2-25 Watt ES Lamps, Energy Efficient Ballast663027T8 High Performance18,000$3.890.09
T12 Other Fluorescent, 2-30 Watt Lamps, Magnetic Pre-Heat Ballast743581T8 High Performance18,000$3.290.09
T12 Other Fluorescent, 2-25 Watt ES Lamps, Magnetic Ballast743027T8 High Performance18,000$3.890.09
T12 Other Fluorescent, 2- 30 Watt Lamps, Magnetic Ballast793334T8 High Performance18,000$3.290.09
T12 Other Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast864469T8 High Performance18,000$5.090.09
----------------------------
T12 5' Fluorescent, 1-75 Watt HO Lamp, Magnetic Ballast904212T8 High Performance
T12 5' Fluorescent, 2-75 Watt HO Lamps, Magnetic Ballast1808424T8 High Performance
T12 6' Fluorescent, 1-85 Watt HO Lamp, Magnetic Ballast1025063T8 High Performance12,000$4.280.09
T12 6' Fluorescent, 2-85 Watt HO Lamps, Magnetic Ballast20410126T8 High Performance
=================================
METAL HALIDE
=================================
High Pressure Sodium, 35 Watt Lamp622006Hard-Wired CFL, 1-32 Watt Lamp (new fixture)10,000$23.010.4
High Pressure Sodium, 150 Watt Lamp1858640Hard-Wired CFL, 4-26 Watt Lamps (new fixture)10,000$18.400.4
Metal Halide, 50 Watt Lamp622006Hard-Wired CFL, 1-32 Watt Lamp (new fixture)10,000$23.010.4
Metal Halide, 70 Watt Lamp902950Hard-Wired CFL, 2-26 Watt Lamps (new fixture)10,000$23.010.4
Metal Halide, 100 Watt Lamp1295440Hard-Wired CFL, 2-42 Watt Lamps (new fixture)10,000$18.400.4
Metal Halide, 150 Watt Lamp1858640Hard-Wired CFL, 4-26 Watt Lamps (new fixture)10,000$18.400.4
Metal Halide, 175 Watt Lamp21094002 Lamp T5 High Output (high bay) New Fixture10,000$18.400.4
Metal Halide, 250 Watt Lamp295113003 Lamp T5 High Output (high bay) New Fixture10,000$18.400.4
Metal Halide, 320 Watt Lamp378144643 Lamp T5 High Output (high bay) New Fixture
Metal Halide, 400 Watt Lamp458260004 Lamp T5 High Output (high bay) New Fixture10,000$18.400.4
Metal Halide, 1000 Watt Lamp108078000Metal Halide Pulse Start, 750 Watt10,000$41.410.4
Metal Halide, 1500 Watt Lamp1605132000Metal Halide Pulse Start, 1000 Watt10,000$47.410.4
=================================
INCANDESCENT
=================================
Incandescent, 1-15 Watt Typical Bulb1595Screw-In CFL, 5 Watt1,500$0.670.05
Incandescent, 1-25 Watt Typical Bulb25170Screw-In CFL, 7 Watt1,500$0.670.05
Incandescent, 1-40 Watt Typical Bulb40403Screw-In CFL, 9 Watt1,500$0.670.05
Incandescent, 1-50 Watt Typical Bulb50429Screw-In CFL, 13 Watt1,200$0.670.05
Incandescent, 1-60 Watt Typical Bulb60800Screw-In CFL, 15 Watt1,200$0.520.05
Incandescent, 1-75 Watt Typical Bulb751086Screw-In CFL, 20 Watt1,200$0.520.05
Incandescent, 1-100 Watt Typical Bulb1001548Screw-In CFL, 26 Watt1,000$0.520.05
Incandescent, 1-150 Watt Typical Bulb1502537Screw-In CFL, 42 Watt1,000$0.520.05
----------------------------
Incandescent, 2-15 Watt Typical Bulbs30191Screw-In CFL, 2-5 Watt1,500$0.670.05
Incandescent, 2-25 Watt Typical Bulbs50340Screw-In CFL, 2-7 Watt1,500$0.670.05
Incandescent, 2-40 Watt Typical Bulbs80805Screw-In CFL, 2-9 Watt1,500$0.670.05
Incandescent, 2-50 Watt Typical Bulbs100858Screw-In CFL, 2-13 Watt1,200$0.670.05
Incandescent, 2-60 Watt Typical Bulbs1201600Screw-In CFL, 2-15 Watt1,200$0.520.05
Incandescent, 3-60 Watt Typical Bulbs1801600Screw-In CFL, 2-15 Watt1,200$0.520.05
Incandescent, 3-40 Watt Typical Bulbs1201600Screw-In CFL, 2-15 Watt1,200$0.520.05
Incandescent, 2-75 Watt Typical Bulbs1502171Screw-In CFL, 2-20 Watt1,200$0.520.05
Incandescent, 2-100 Watt Typical Bulbs2003096Screw-In CFL, 2-26 Watt1,000$0.520.05
Incandescent, 2-150 Watt Typical Bulbs3005073Screw-In CFL, 2-42 Watt1,000$0.520.05
----------------------------
Incandescent, 4-40 Watt Typical Bulbs1601610Screw-In CFL, 4-9 Watt1,500$0.670.05
Incandescent, 4-60 Watt Typical Bulbs2403199Screw-In CFL, 4-15 Watt1,200$0.670.05
Incandescent, 4-75 Watt Typical Bulbs3004342Screw-In CFL, 4-20 Watt1,200$0.520.05
Incandescent, 4-100 Watt Typical Bulbs4006192Screw-In CFL, 4-26 Watt1,200$0.520.05
----------------------------
Incandescent, 1-65 Watt PAR Lamp65608New LED Downlight (recessed can, LR6 or equivalent)2,000$4.000.09
Incandescent, 75 Watt Reflector Lamp75801New LED Downlight (recessed can, LR6 or equivalent)2,000$7.000.09
Incandescent, 90 Watt Reflector Lamp901071Screw-in Ceramic Metal Halide (self-ballasted)2,000$7.000.09
Incandescent, 100 Watt Reflector Lamp1001071Screw-in Ceramic Metal Halide (self-ballasted)2,000$7.000.09
Incandescent, 120 Watt Reflector Lamp1201440Ceramic Metal Halide, 1-39 Watt PAR Lamp2,000$7.000.09
Incandescent, 150 Watt Reflector Lamp1501710Ceramic Metal Halide, 1-39 Watt PAR Lamp2,000$7.000.09
----------------------------
Incandescent, 1-200 Watt Bulb2003154Screw-In CFL, 42 Watt750$4.290.09
Incandescent, 1-300 Watt Bulb3004802Screw-In CFL, 85 Watt750$4.920.09
Incandescent, 1-500 Watt Bulb5008811T8 High Performance750$10.840.09
Incandescent, 1-620 Watt Bulb6209350T8 High Performance750$15.360.09
=================================
HALOGEN
=================================
MR-16 or MRC-16 Halogen Display Lamps, 20 Watts20240Screw-in LEDNo DefaultNo DefaultNo Default
MR-16 or MRC-16 Halogen Display Lamps, 35 Watts35490Screw-in LEDNo DefaultNo DefaultNo Default
MR-16 or MRC-16 Halogen Display Lamps, 40 Watts40600Screw-in LEDNo DefaultNo DefaultNo Default
MR-16 or MRC-16 Halogen Display Lamps, 50 Watts50790Screw-in Ceramic Metal Halide (self-ballasted)No DefaultNo DefaultNo Default
MR-16 or MRC-16 Halogen Display Lamps, 75 Watts751320Screw-in Ceramic Metal Halide (self-ballasted)No DefaultNo DefaultNo Default
----------------------------
Halogen, 100 Watt1001440Screw-in Ceramic Metal Halide (self-ballasted)1,500$5.990.09
Halogen, 150 Watt1502160Ceramic Metal Halide, 1-39 Watt PAR Lamp1,500$5.990.09
Halogen, 250 Watt2503600Ceramic Metal Halide, 1-70 Watt PAR Lamp1,500$6.550.09
Halogen, 300 Watt3004680Ceramic Metal Halide, 1-100 Watt PAR Lamp1,500$7.050.09
Halogen, 500 Watt5008550Ceramic Metal Halide, 1-150 Watt Lamp (single or double end)1,500$6.980.09
Halogen, 750 Watt75013500Metal Halide Pulse Start, 200 Watt Lamp1,500$14.000.09
Halogen, 1000 Watt100018900Metal Halide Pulse Start, 200 Watt Lamp1,500$14.000.09
Halogen, 1500 Watt150029700Metal Halide Pulse Start, 350 Watt Lamp1,500$14.000.09
=================================
HIGH PRESSURE SODIUM
=================================
High Pressure Sodium, 35 Watt Lamp451845None24,000$15.720.4
High Pressure Sodium, 50 Watt Lamp683280None24,000$15.720.4
High Pressure Sodium, 70 Watt Lamp865166None24,000$15.720.4
High Pressure Sodium, 100 Watt Lamp12077901 Lamp T5 High Output (high bay) New Fixture24,000$15.720.4
High Pressure Sodium, 150 Watt Lamp170131201 Lamp T5 High Output (high bay) New Fixture24,000$15.720.4
High Pressure Sodium, 200 Watt Lamp245180402 Lamp T5 High Output (high bay) New Fixture24,000$15.720.4
High Pressure Sodium, 250 Watt Lamp295225503 Lamp T5 High Output (high bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)24,000$15.720.4
High Pressure Sodium, 310 Watt Lamp365303404 Lamp T5 High Output (high-bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)24,000$15.720.4
High Pressure Sodium, 400 Watt Lamp457410006 Lamp T5 High Output (high-bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)24,000$15.720.4
High Pressure Sodium, 1000 Watt Lamp110011480012 Lamp T5 High Output (high bay) New Fixture24,000$47.920.4
=================================
MERCURY VAPOR
=================================
Mercury Vapor, 100 Watt Lamp1253400T8 High Performance24,000$12.350.4
Mercury Vapor, 175 Watt Lamp2057600T8 High Performance24,000$12.350.4
Mercury Vapor, 250 Watt Lamp28510700T8 High Performance24,000$13.850.4
Mercury Vapor, 400 Watt Lamp45419100T8 High Performance24,000$18.340.4
Mercury Vapor, 1000 Watt Lamp108045000T8 High Performance24,000$64.080.4
=================================
ENTER OTHER LAMP/BALLAST COMBINATIONS
=================================
2-PL13 Fixture302412Explain in notes field on site audit tab if necessary
T12 2' Fluorescent, 2-20 Watt Lamp, Magnetic Ballast481920Explain in notes field on site audit tab if necessary
Explain in notes field on site audit tab if necessary
Explain in notes field on site audit tab if necessary
=================================

Data Proposed

1234567891011121314151617181920
Updated January 9, 2009. This list is not meant to be complete, you can add qualifying equipment to this list.Default lamp life and cost data used for estimating life-cycle periodic replacement costs.
Description of Proposed Lamp/Ballast CombinationInput WattsMean System LumensMeasure CategoryRebate AmountNotes / Alternate Suggestions# lampsbflumen lamplumen maintballast typeBEFLPWRated Average Lamp Life (hrs/lamp for RS ballast @ 12 hrs/start)Lamp Cost ($/lamp)Lamp Change Labor (hours/lamp)
Add qualifying measure(s) here. See the technical specifications for guidance.<<Input a wattage and mean system lumens
No recommendation (leave fixture as-is)N/A$0Leave fixture as-is
Decommission (Permanently Remove) Lighting Fixture00N/A$0Permanently remove unneeded light fixtures
=================================
HIGH PERFORMANCE T8 or NLO T5 LAMP and BALLAST (New Fixture or Retrofit)
=================================
32 Watt Lamps
----------------------------
High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products list.252297A1$20Best Energy Efficient Choice10.7831000.95ISL3.1296.7230,000$3.250.09
High Performance T8, 1-4' lamp with Normal Light Output ballast. Consult CEE's qualifying products list.282592A1$20Typical high performance recommendation10.8831000.95ISN3.1497.4330,000$3.250.09
High Performance T8, 1-4' lamp with High Light Output ballast. Consult CEE's qualifying products list.322945A1$20Best choice if de-lamping11.0031000.95PRS3.1396.8830,000$3.250.09
----------------------------
High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.484594A2$40Best Energy Efficient Choice20.7831000.95ISL1.63100.7530,000$3.250.09
High Performance T8, 2-4' lamps with Normal Light Output ballast. Consult CEE's qualifying products list.555183A2$40Typical recommendation20.8831000.95ISN1.6099.2030,000$3.250.09
High Performance T8 Stairwell or Parking Lot Light, 2-4' lamps with Normal Light Output ballast and fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)605183A2/J1$75Stairwell or parking garage new fixture (includes a light that is on 24/7)20.8831000.95ISN1.4790.9330,000$3.250.09
High Performance T8, 2-4' lamps with High Light Output ballast. Consult CEE's qualifying products list.746774A2$40Best choice if de-lamping21.1531000.95ISH1.5596.3530,000$3.250.09
----------------------------
High Performance T8, 2-8' 54 Watt lamps with Normal Light Output ballast, 96 Watt typical, System efficacy >95 lumens per Watt969587A2$40Various lamp ballast combinations are available, typical 96 watt ballast20.8758000.95ISN0.91105.1324,000$8.990.09
High Performance T8, 2-8' lamps with Normal Light Output ballast, 110 Watt Max, System efficacy >95 lumens per Watt11010199A2$40Various lamp ballast combinations are available, typical 110 watt ballast20.8861000.95ISN0.8097.6024,000$8.990.09
----------------------------
High Performance T8, 3-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.726803A2$40Best Energy Efficient Choice30.7731000.95ISL1.0799.4630,000$3.250.09
High Performance T8, 3-4' lamps with Normal Light Output ballast. Consult CEE's qualifying products list.817686A2$40Typical recommendation30.8731000.95ISN1.0799.8930,000$3.250.09
High Performance T8, 3-4' lamps with High Light Output ballast. Consult CEE's qualifying products list.11010160A2$40Best choice if de-lamping31.1531000.95ISH1.0597.2330,000$3.250.09
----------------------------
High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.959071A2$40Best Energy Efficient Choice40.7731000.95ISL0.81100.5130,000$3.250.09
High Performance T8, 4-4' lamps with Normal Light Output ballast. Consult CEE's qualifying products list.10810249A2$40Typical recommendation40.8731000.95ISN0.8199.8930,000$3.250.09
High Performance T8, 4-4' lamps with High Light Output ballast. Consult CEE's qualifying products list.14813547A2$40High-Bay applications41.1531000.95ISH0.7896.3530,000$3.250.09
----------------------------
25 Watt Lamps
----------------------------
High Performance T8, 2-4' 25 Watt lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.383474A2$40Best Energy Efficient Choice20.7724000.94ISL2.0397.2630,000$3.250.09
High Performance T8, 3-4' 25 Watt lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.585211A2$40Best recommendation if de-lamping is not an option (i.e. deep cell parabolic fixtures)30.7724000.94ISL1.3395.5930,000$3.250.09
High Performance T8, 4-4' 25 Watt lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.776948A2$40Best recommendation if de-lamping is not an option (i.e. deep cell parabolic fixtures)40.7724000.94ISL1.0096.0030,000$3.250.09
----------------------------
T5 Normal Light Output Lamps
----------------------------
New High Performance NLO T5, 2-4' lamps with Normal Light Output ballast (New Fixture or Retrofit)585235A2$40RT5 or equivalent new fixture20.9529000.95ISN1.6495.0024,000$6.000.09
=================================
RETROFIT HO/VHO T12 FIXTURES to T8 LAMPS & BALLASTS
=================================
4 Lamp T8 4' with Normal Light Output ballast (Upgrade from T12 HO/VHO)10810249K2$80Use 2-2 lamp HLO ballasts only if absolutely necessary40.8731000.95ISH0.8199.8930,000$3.250.09
4 Lamp T8 4' with High Light Output ballast (Upgrade from T12 HO/VHO)14813547K2$80Use 2-2 lamp HLO ballasts only if absolutely necessary41.1531000.95ISH0.7896.3530,000$3.250.09
6 Lamp T8 4' with Normal Light Output ballast (Upgrade from T12 HO/VHO)16215373K2$80Use 2-2 lamp HLO ballasts only if absolutely necessary60.8731000.95ISH0.5499.8930,000$3.250.09
6 Lamp T8 4' with High Light Output ballast (Upgrade from T12 HO/VHO)22221027K2$80Use 2-4 lamp HLO ballasts only if absolutely necessary61.1931000.95ISH0.5499.7030,000$3.250.09
8 Lamp T8 4' with Normal Light Output ballast (Upgrade from T12 HO/VHO)21620497K2$80Use 2-2 lamp HLO ballasts only if absolutely necessary80.8731000.95ISH0.4099.8930,000$3.250.09
8 Lamp T8 4' with High Light Output ballast (Upgrade from T12 HO/VHO)29627094K2$80Use 2-2 lamp HLO ballasts only if absolutely necessary81.1531000.95ISH0.3996.3530,000$3.250.09
=================================
HIGH OUTPUT (high-bay) FLUORESCENT (Install New Fixture)
=================================
High Output T5 New Fixtures
----------------------------

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .