Fence_Design_Sheet.pdf

PDF 676 KB Posted

Attached to
Fence Construction - Van Zandt County, Texas Federal contract opportunity
Solicitation number
AG-4D90-S-16-0031
Issued by
Department of Agriculture National Resources Conservation Service Western Region

About this file

Fence Design Sheet

View the file

Other files for this federal contract opportunity

Other files attached to Fence Construction - Van Zandt County, Texas, newest first.
File Type Posted
Van_Zandt_CO__Fence_Construction1_site_showing_notes.doc DOC document
AG-4D90-S-16-0031_Amendment1.pdf PDF
382_SOW_Fence.pdf PDF
Solicitation_AG-4D90-S-16-0031.pdf PDF
Maps.pdf PDF
382_Fence_Specification-Revised-2014.pdf PDF
382_Quality_Control_Plan_for_Fence_2016.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Participant Name :

Contract Number : Date : 02/22/16

I. WIRE : Planned

A. Barbed wire or Net wire Wire must meet ASTM-A 116 for woven or ASTM-121 for barbed

1. Size (gauge) 12 1/2

2. Strands 4

3. Height of top wire 44

4. Height of bottom wire 18

5. Wire attachments :

(T-post) a. wire clips 12 1/2 (Wood) b. staples x

6. Splice used : Western Union (* 8 wraps / side) or x

Western Union Splice

II. LINE POST : Planned

A. T - Post (new high carbon painted steel)

1. Length (normal) 6

2. Length (rocky soils only) x

3. Weight per foot 1.33

4. Spacing 12

5. Depth in ground : Normal - 24

Rocky - x

B. Wood Post (good cedar or treated pine)

1. Length (normal) x

2. Length (rocky soils only) x

3. Top diameter x

4. Spacing x

5. Depth in ground : Normal - x

B. Steel or Galvanized Post (must be capped and painted)

1. Length (normal) 6

2. Length (rocky soils only) x

3. Top diameter 2 3/8

4. Spacing 12

5. Depth in ground : Normal - 24

Pg.1 of 6

18 in.

24 in.

6 ft.+

5.5 ft.

2 3/8 in.(OD) + 20 ft. or less

24 in.

20 ft. or less

24 in.

20 ft. or less

5.5 ft.

3 in.+

Minimum

6 ft.+

5.5 ft.

1.25 - 1.33 lb/ft.

44 in.+

*Western Union

Loop Splice

14 in.+

12 - 12 1/2 gauge 9 gauge (1.5+ in.)

NON-ELECTRIC FENCE (382) SPECIFICATIONS

Quick Reference Checklist & Certification of Review

Minimum

6674421301D56 NRCS Planner : Julie Moore

May-09

III. END / GATE BRACES : Planned

A. STEEL PIPE (all exposed metal must be painted)

(1) Upright post (must be capped and cemented in ground) -

1. Length 8.0 +

2. Top diameter 2 3/8 +

3. Inside spacing 6.0+

4. Depth in ground 36.0+

(2) Cross member -

1. Length 6.0+

2. Top diameter 2 3/8 +

3. Distance above ground 28 - 36

Planned

No (Yes, No or NA)

Planned

Yes (Yes, No or NA)

Pg.2 of 6

2 3/8 in.(OD) +

28 - 36 in.+

WELDED STEEL 3-POST DIAGONAL END BRACE ASSEMBLY

WELDED STEEL 3-POST (double H) END BRACE

6 ft.+

2 3/8 in.(OD) + 6 ft.+

36 in.+

8 ft.+

Minimum

Option 1 :

Option 2 :

(applicable only to sandy loam and finer texture) Pipe size Depth driven 2 3/8 in. - 5 ft.

2 7/8 - 4 1/2 in. - 4 ft.

5+ in. - 3 ft.

Pipe must be painted or galvanized

(applicable only to sandy loam and finer texture) Pipe size Depth driven 2 3/8 in. - 5 ft.

2 7/8 - 4 1/2 in. - 4 ft.

5+ in. - 3 ft.

Pipe must be painted or galvanized

III. END / GATE BRACES : Planned

B. WOOD (pressure treated or durable wood)

(1) Upright post -

1. Length NA

2. Top diameter NA

3. Inside spacing NA

4. Depth in ground NA

(2) Cross member -

1. Length NA

2. Top diameter NA

3. Distance above ground NA

Planned

No (Yes, No or NA)

THREE POST DOUBLE "H" BRACE END ASSEMBLY WITHOUT DEADMAN

Planned

No (Yes, No or NA)

Pg.3 of 6

28 - 36 in.+

TWO (2) POST END BRACE WITH DEADMAN

6 ft.+ 36 in.+

6 ft.+ 4 in.+

8 ft.+ 6 in.+

Minimum

Option 1 :

Option 2 :

IV. PULL ASSEMBLY BRACES : Planned

A. STEEL PIPE (all exposed metal must be painted)

(1) Upright post (must be capped and cemented in ground) -

1. Length 8.0 +

2. Top diameter 2 3/8 +

3. Inside spacing 6.0+

4. Depth in ground 36+

(2) Cross member -

1. Length 6.0 +

2. Top diameter 2 3/8 +

3. Distance above ground 28-36

(H - type brace)

Planned

Yes (Yes, No or NA)

Planned

No (Yes, No or NA)

Pg.4 of 6

2 3/8 in.(OD) + 28 - 36 in.+

WELDED STEEL 2-POST PULL ASSEMBLY

Minimum

8 ft.+ 2 3/8 in.(OD) +

THREE POST WELDED PULL ASSEMBLY

36 in.+

Option 1 :

Option 2 :

Concrete mound to prevent water from standing around post

IV. PULL ASSEMBLY BRACES : Planned

B. WOOD (pressure treated or durable wood)

(1) Upright post -

1. Length x

2. Top diameter x

3. Inside spacing (H-brace) x

4. Depth in ground x

(2) Cross member -

1. Length x

2. Top diameter x

3. Distance above ground x

(H - type brace)

Planned (Option 1)

No (Yes, No or NA)

Planned (Option 2)

No (Yes, No or NA)

Pg.5 of 6

4 in.+ 28 - 36 in.+

"H" BRACE AND SINGLE POST PULL ASSEMBLIES

36 in.+

Minimum

8 ft.+ 4 in.+ 6 ft.+

Option 2 :Option 1 :

NOTE : All pull assemblies will be placed at approximately 1,320 ft. (normal length of spool) and at points of extreme changes in slopes.

Gates will meet the minimum requirements:

Steel or Galvanized Metal 5 Cross Members, 1 Vertical Stay 22 Gauge Tubing 1.625 in Outer Diameter Galvanized, Powder Coated, or Painted Finish

V. ANGLE BRACES :

NOTE : Angle braces required where the angle of the fence changes more than 20 degrees.

(To be placed on the inside of curves or angles)

Planned

* Preferred: A. STEEL PIPE (all exposed metal must be painted)

(1) Upright post (must be capped) -

1. Length 8.0 +

2. Top diameter 2 3/8 +

3. Upright post to anchor 7 - 8 ft.

4. Depth in ground 36 +

(2) Angle brace pipe -

1. Length 7 - 8 +

2. Top diameter 2 3/8 +

(3) Anchor pipe -

1. Length 24 +

2. Top diameter 2 3/8 +

3. Depth in ground 18.0 +

State law requires that you and/or your contractor notify the One-Call Board of Texas at 1-800-545-6005 no more than 14 days, no less than 48 hours, excluding Saturdays, Sundays, and legal holidays, prior to starting construction/excavation activities.

I have reviewed all of the NRCS Fencing Specifications listed above and understand that I must comply with the planned fencing specifications to maintain eligibility for cost-share assistance.

Participant Name : Date : Pg.6 of 6

18 in.+

2 3/8 in.(OD) +

24 in.+ 2 3/8 in.(OD) +

7 - 8 ft.

36 in.+

7 - 8 ft.+

Minimum

8 ft.+ 2 3/8 in.(OD) +

Pipe size Depth driven 2 3/8 in. - 5 ft.

2 7/8 - 4 1/2 in. - 4 ft.

5+ in. - 3 ft.

Sheet1

File details come from the government source that posted it. Updated .