AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE PAGE OF PAGES

1 8

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

Amendment 1 07/24/2014

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

USDA Forest Service Mt. Baker-Snoqualmie National Forest 2930 Wetmore Avenue, Suite 3A Everett, WA 98201

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State, and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NO.

AG-05M6-S-14-0019

9B. DATED (SEE ITEM 11)

07/21/2014

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

(X) A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN

THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return ____ copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.

The purpose of this Amendment is to replaced Section 22 41 00 Residential Plumbing Fixtures in section J of the Solicitation with this Amended Section 22 41 00. Also Drawings 2 of 5 and 3 of 5 the word “Refurbished” is misspelled.

Drawing 2 of 5 on the First Floor Proposed Plan under Living Room it shoud read “Refurbished Hardwood Floor” Drawing 3 of 5 on the Second Floor Proposed Plan under Bunkbed Room is should read “Refurbished Wall Panels”.

All else remains the same. The time of the Solicitation is not extended.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

Jorge A Somoza Contracting Officer

15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED

07/24/2014

(Signature of person authorized to sign) (Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

30-105 STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA

FAR (48 CFR) 53.243

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 1

SECTION 22 41 00 - RESIDENTIAL PLUMBING FIXTURES

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Faucets.

2. Lavatories.

3. Showers.

4. Kitchen sinks.

5. Toilet seats.

6. Supply fittings.

7. Waste fittings.

1.2 INFORMATIONAL SUBMITTALS

A. Coordination Drawings: Counter cutout templates for mounting of counter-mounted plumbing fixtures.

B. Sample Warranty: For special warranty.

PART 2 - PRODUCTS

2.1 LAVATORIES

A. Lavatories: Oval, vitreous china, pedestal.

1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. American Standard America.

b. Barclay Products Limited.

c. Kohler Co.

d. Peerless Pottery Sales, Inc.

e. Sterling; a Kohler company.

f. St. Thomas Creations.

g. TOTO USA, INC.

2. Fixture:

a. Standard: ASME A112.19.2/CSA B45.1.

b. Oval Nominal Size: 24 by 18 inches.

c. Color: White.

Amendment 1

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 2

3. Supply Fittings: Comply with requirements in "Supply Fittings" Article.

4. Waste Fittings: Comply with requirements in "Waste Fittings" Article.

2.2 LAVATORY FAUCETS

A. NSF Standard: Comply with NSF/ANSI 61, "Drinking Water System Components - Health Effects," for faucet materials that will be in contact with potable water.

B. Lavatory Faucets Single-control mixing and Two-handle mixing valve.

1. General-Duty, Solid-Brass Faucets:

a. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1) American Standard America.

2) Delta Faucet Company.

3) Eljer, Inc.

4) Elkay Manufacturing Co.

5) Kohler Co.

6) Matco-Norca.

7) Moen Incorporated.

8) Price Pfister, Inc.

2.3 SHOWERS

1. PMMA (Acrylic) Showers:

a. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

b. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on Specification or comparable product by one of the following:

1) Acryline USA, Inc.

2) Aqua Bath Company, Inc.

3) Aqua Glass Corporation.

4) Aquatic Industries, Inc.

5) Clarion Bathware.

6) Crane Plumbing, L.L.C.

7) Jacuzzi, Inc.

8) Kohler Co.

2. Standard: ANSI Z124.1.2.

3. Retain first "Surround" Subparagraph below for FRP surround.

4. Surround: One piece or sealed, multiple piece.

5. Bathing Surface: Slip resistant according to ASTM F 462.

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 3

6. Color: White.

7. Drain Location: Center.

2.4 SHOWER FAUCETS

A. NSF Standard: Comply with NSF/ANSI 61, "Drinking Water System Components - Health Effects," for faucet materials that will be in contact with potable water.

B. Shower Faucets: Single handle, pressure balance, mixing valve.

1. Single-Handle, Pressure-Balance Faucets:

a. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

b. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated in Specification comparable product by one of the following:

1) American Standard America.

2) Kohler Co.

3) Lawler Manufacturing Co., Inc.

4) Leonard Valve Company.

5) Matco-Norca.

6) Moen Incorporated.

2. Fixture:

a. Standard: ASME A112.18.1/CSA B125.1 and ASSE 1016.

b. General: Include hot- and cold-water indicators; check stops; and fixed shower head, arm, and flange. Coordinate faucet inlets with supplies.

c. Body Material: Solid brass.

d. Finish: Polished chrome plate.

e. Maximum Flow Rate: 2.5 gpm unless otherwise indicated.

3. Shower Head:

a. Type: Ball joint and head integral with mounting flange

b. Shower Head Material: Nonmetallic with chrome-plated finish.

c. Spray Pattern: Adjustable.

2.5 BATHROOM SINKS

A. Bar Sinks: Single bowl, counter mounted, enameled cast iron

1. Enameled Cast-Iron Bar Sinks:

a. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 4

b. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated in Specifications or comparable product by one of the following:

1) Commercial Enameling Company.

2) Eljer, Inc.

3) Kohler Co.

2. Fixture:

a. Standard: ASME A112.19.1/CSA B45.2 for enameled cast-iron lavatories.

b. Standard: ANSI Z124.3 for PMMA lavatories.

c. Standard: ASME A112.19.2/CSA B45.1 for vitreous-china lavatories.

d. Type: See Specifications

3. Supply Fittings: Comply with requirements in "Supply Fittings" Article.

4. Waste Fittings: Comply with requirements in "Waste Fittings" Article.

2.6 KITCHEN SINKS

A. Kitchen Sinks: Two bowl, counter mounted stainless steel.

1. Stainless-Steel Kitchen Sinks:

a. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1) Elkay Manufacturing Co.

2) Franke Consumer Products, Inc.

3) Griffin Products, Inc.

4) Houzer, Inc.

5) Just Manufacturing.

6) Kohler Co.

2.7 SINK FAUCETS

A. NSF Standard: Comply with NSF/ANSI 61, "Drinking Water System Components - Health Effects," for faucet materials that will be in contact with potable water.

B. Sink Faucets kitchen sink.

1. General-Duty, Solid-Brass Faucets:

a. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1) American Standard America.

2) Delta Faucet Company.

3) Eljer, Inc.

4) Elkay Manufacturing Co.

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 5

5) Kohler Co.

6) Moen Incorporated.

7) Price Pfister, Inc.

2.8 TOILET SEATS

A. Toilet Seats:

1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following]:

a. American Standard America.

b. Bemis Manufacturing Company.

c. Centoco Manufacturing Corporation.

d. Church Seats.

e. Eljer, Inc.

f. Kohler Co.

2. Standard: IAPMO/ANSI Z124.5.

3. Material: Plastic.

4. Type: Commercial.

5. Shape: Regular rim (Closed front)

6. Size: Regular

7. Hinge Material: Noncorroding meta.

8. Seat Cover: Not required.

9. Color: White.

2.9 SUPPLY FITTINGS

A. NSF Standard: Comply with NSF/ANSI 61, "Drinking Water System Components - Health Effects," for faucet materials that will be in contact with potable water.

B. Standard: ASME A112.18.1/CSA B125.1.

C. Kitchen Sink Supply Fittings:

1. Supply Piping: Chrome-plated-brass pipe or chrome-plated-copper tube matching water-supply piping size. Include chrome-plated wall flange.

2. Stops: Chrome-plated-brass, one-quarter-turn, ball-type or compression stop with inlet connection matching water-supply piping type and size.

a. Operation: Wheel handle.

2.10 WASTE FITTINGS

A. Standard: ASME A112.18.2/CSA B125.2.

B. Drain: Grid type with NPS 1-1/4 (DN 32) offset tailpiece for accessible lavatories.

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 6

C. Drain: Pop-up type with NPS 1-1/4 (DN 32) straight tailpiece as part of faucet for standard lavatories.

D. Drain: Grid type with NPS 1-1/2 (DN 40) offset tailpiece for accessible kitchen sinks.

E. Drain: Grid type with NPS 1-1/2 (DN 40) straight tailpiece for standard kitchen sinks.

2.11 GROUT

A. Standard: ASTM C 1107/C 1107M, Grade B, post-hardening and volume-adjusting, dry, hydraulic-cement grout.

B. Characteristics: Nonshrink; recommended for interior and exterior applications.

C. Design Mix: 5000-psi (34.5-MPa), 28-day compressive strength.

D. Packaging: Premixed and factory packaged.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine roughing-in of water-supply and sanitary drainage and vent piping systems to verify actual locations of piping connections before plumbing-fixture installation.

B. Examine walls, floors, cabinets, and counters for suitable conditions where fixtures will be installed.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. Install plumbing fixtures level and plumb according to roughing-in drawings.

B. Install floor-mounted water closets on closet flange attachments to drainage piping.

C. Install counter-mounting fixtures in and attached to casework.

D. Install pedestal lavatories on pedestals and secured to wood blocking in wall.

E. Install water-supply piping with stop on each supply to each fixture to be connected to water distribution piping. Attach supplies to supports or substrate within pipe spaces behind fixtures.

Install stops in locations where they can be easily reached for operation.

1. Exception: Use ball or gate valves if supply stops are not specified with fixture. Comply with valve requirements specified in Section 220523.12 "Ball Valves for Plumbing Piping" and Section 220523.15 "Gate Valves for Plumbing Piping."

RESIDENTIAL PLUMBING FIXTURES 22 41 00 - 7

F. Install tanks for accessible, tank-type water closets with lever handle mounted on wide side of compartment.

G. Install toilet seats on water closets.

H. Install faucet flow-control fittings with specified flow rates and patterns in faucet spouts if faucets are not available with required rates and patterns. Include adapters if required.

I. Install shower flow-control fittings with specified maximum flow rates in shower arms.

J. Install traps on fixture outlets.

1. Exception: Omit trap on fixtures with integral traps.

2. Exception: Omit trap on indirect wastes unless otherwise indicated.

3.3 CONNECTIONS

A. Connect fixtures with water supplies, stops, and risers, and with traps, soil, waste, and vent piping. Use size fittings required to match fixtures.

B. Comply with water piping requirements specified in Section 221116 "Domestic Water Piping."

C. Comply with soil and waste piping requirements specified in Section 221316 "Sanitary Waste and Vent Piping."

3.4 ADJUSTING

A. Operate and adjust plumbing fixtures and controls. Replace damaged and malfunctioning fixtures, fittings, and controls.

B. Adjust water pressure at faucets to produce proper flow.

3.5 CLEANING AND PROTECTION

A. After completing installation of plumbing fixtures, inspect and repair damaged finishes.

B. Clean plumbing fixtures, faucets, and other fittings with manufacturers' recommended cleaning methods and materials.

C. Provide protective covering for installed plumbing fixtures and fittings.

D. Do not allow use of plumbing fixtures for temporary facilities unless approved in writing by Owner.

END OF SECTION 224100

File details come from the government source that posted it. Updated .