ADDITIONAL TECH RU16MAR227777A.pdf
PDF 38 KB Posted
- Solicitation number
- HC101322QA329
- Issued by
-
Defense Information Systems Agency
About this file
This document contains an additional technical specifications file and a related federal contract opportunity solicitation. The additional technical specifications file outlines requirements for an OC-3C circuit, including fiber termination parameters, availability and response time standards, testing requirements, and round trip delay thresholds. The related federal contract opportunity solicitation seeks quotes to provide, install, and maintain a 155.52MB OC-3C lease between Fort Drum, New York and Ottawa, Canada. Quotes are due by June 6, 2022 and the selected company must comply with FAR commercial item terms and conditions. The Defense Information Systems Agency is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Vendor Block Diagram Sample and Maps.pdf | ||
| HC101322QA329.v2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDITIONAL TECHNICAL SPECIFICATIONS
1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: FRAME FORMAT: STS-3C, 1310NM RATE: PLUS OR MINUS 20 PPM
USER PROVIDED STS-3C FRAMING FROM GOVT ROUTER.
(B) NO CHANNELIZATION REQUIRED.
(C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, AT LEAST 99.98% OF THE TIME OR IAW THE APPROVED TARIFFS.
(D) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE-
CALL HAS BEEN REPORTED.
(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO
CIRCUIT.
(F) SINGLE MODE FIBER TERMINATIONS SC/SC CONNECTORS.
(G) NO NETWORK INTERFACE UNIT.
(H) DEDICATED PATH.
(I) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.
(J) THE VENDOR MUST TEST THE CIRCUIT END TO END FOR 72 HOURS UTILIZING A 2E23
TEST PATTERN.
(K) THE VENDOR WINNING AWARD OF THIS OC-3C SERVICE MUST HAVE A 24X7 NETWORK
OPERATIONS CENTER.
(L) THE OC-3C SERVICE WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY DISA
GOC IP "B" AT SCOTT AFB, IL. AFTER COMPLETION OF SATISFACTORY TEST BY DISA GOC
IP "B": (C) 618-418-8627, (D) 418-8627.
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 155.52MB/S 20 PPM. LINE CODE: OPTICAL.
FRAME FORMAT. SONET/STS-3C
1. TEST AND ACCEPTANCE: FIBER OPTIC OC-3C CIRCUITS SHALL PASS A FULLY
DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY THE ATM NETWORK OPERATIONS
CENTER IT&A.
2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS
SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE
(AVAILABILITY, SES, DM, EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL BE MEASURED
AND RECORDED OVER THE DURATION OF THE CONTIGUOUS 72 HOUR TESTING INTERVAL
AND SHALL BE MEASURED AND RECORDED PER DEFINITION IN ITU RECOMMENDATION
G.826 AND M.2100.
3. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE
FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE
GREATER THAN 99.98%. SEVERELY ERRORED SECONDS (SES) SHALL BE LESS THAN
0.02%. DEGRADED MINUTES (DM) SHALL BE LESS THAN 0.2%. ERROR FREE SECONDS
(EFS) SHALL BE GREATER THAN 99%.
4. LOSS OF BIT COUNT INTEGRITY (LBCI): LOSS OF BIT COUNT INTEGRITY SHALL BE
MONITORED ONLY BY THE FOLLOWING METHOD: USING TEST EQUIPMENT WHICH CAN
DETECT AND MEASURE THE OCCURRENCE OF THE INSERTION OR DELETION OF ONE OR
MORE BITS INTO THE DIGITAL BIT STREAM, ON MANY MANUFACTURERS BERT TEST
EQUIPMENT THIS IS MONITORED USING THE "PATTERN SLIP" PARAMETER WHERE EVERY
OCCURRENCE OF A PATTERN SLIP "EVENT" MARKS THE OCCURRENCE OF A LBCI
(RATHER THAN THE RAW TOTAL NUMBER OF PATTERN SLIPS ACCUMULATED OVER A
TESTING INTERVAL).
5. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24
HOURS. 6. ROUND TRIP DELAY (RTD): THE ROUND TRIP DELAY (RTD) FOR THIS DISA IP
BACKBONE CIRCUIT WILL BE MEASURED IN MILLISECONDS FROM THE CUSTOMERS
SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMERS SERVICE DELIVERY POINT
(SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS TO
EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION.
File details come from the government source that posted it. Updated .