This document provides specifications for fiberglass stock water troughs to be procured through a solicitation by the Bureau of Land Management. The specifications require seamless laminate construction of fiberglass stock water troughs that are a minimum of 3/16 inch thick and weigh at least 240 pounds for a 1,150 gallon round trough. The troughs must have 30-40 percent fiberglass content and be constructed on a male mold to ensure a nonporous interior surface. The interior of the trough must contain sand and fiberglass or gel-coat resin. Delivery of the troughs is to be made to the Dillon Field Office in Dillon, Montana. Pricing will be based on the unit prices provided in the bid schedule for fiberglass stock water troughs measuring 10 feet in diameter with a 1,100-1,200 gallon capacity including a built-in bird ramp.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140L3623Q0061.pdf | ||
| Schedule_of_Items.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications Fiberglass Stock Water Trough
Part 1: General
SUMMARY:
A. The troughs will be used for stock water storage. All troughs will have molded bird ramps. All troughs furnished, shall be of the same dimensions and capacities.
B. The bird ramp shall contain sand and fiberglass resin or sand and gel-coat resin (manufacturer's option). Sand used shall be a washed, fine graded material.
1.2 CONSTRUCTION - GENERAL SPECIFICATIONS:
A. General: Trough shall be seamless laminate construction throughout. Approximately 30 percent glass and 70 percent resin. Trough shall be constructed on a male mold to ensure a nonporous interior surface.
B. Wall: Wall shall be tapered sufficiently and stacking blocks provided for ease in nesting troughs for shipment and storage and to prevent sticking when nested.
C. Bottom: Trough shall have a sand roughened interior floor surface.
1.3 CONSTRUCTION - TECHNICAL SPECIFICATIONS:
A. Thickness: Troughs and bird ramps shall have a nominal minimum thickness of 3/16 inch.
B. Weight: Minimum weight before final finish of interior bottom shall be: 240 lbs. for 1150 gallon (round).
C. Glass Reinforcement: Fiberglass content shall be 30-40 percent.
D. A ¾” drain hole that is drilled and a drain plug.
E. Resin: Resin and the content of resins in the trough shall meet the following specification.
1. Commercial grade of orthophthalic polyester
2. Resin content shall be a maximum of 70 percent.
3. Ultimate tensile strength of 13,000 psi minimum.
4. Ultimate flexural strength of 20,000 psi minimum.
5. Cured compressive strength 24,000 psi minimum at break.
6. Barcol hardness 36 minimum.
1.4 FINISH:
A. Interior bottom of trough shall contain sand and fiberglass resin or sand and gel-coat resin (manufacturer's option). Sand used shall be a washed, fine graded material, 1/8 inch approximate diameter.
1.5 DELIVERY:
A. Deliver all fiberglass products to the Dillon Filed Office, Bureau of Land Management, 1005
Selway Drive, Dillon, Montana. Operating hours are 8 a.m. to 4:30 p.m.
1.6 BASIS OF PAYMENT:
A. Prices and payment will be full compensation for the product described in this section. Payment will be made under the unit price as stated in the bid schedule.
Pay Item Description Unit
MT-11201 (1)
Fiberglass Stock Water Trough 10ft in diameter, 1,100-1,200 Gallon Capacity (Round) With built in bird ramp(molded)………………………………. each
END OF SECTION