Salient Characteristics S20035
ACOUSTIC DOPPLER CURRENT PROFILER
SALIENT CHARACTERISTICS:
1 EA, Cable
1. Shall be compatible with ADCP specified below.
2. Shall be for RS232 and RS422 communication.
1 EA, Acoustic Doppler Current Profiler (ADCP):
3. Shall be a self-contained unit.
4. Shall be capable of operating from buoys or platforms as a down looker.
5. Shall be capable of transmitting data via cable RS232 or RS422.
6. Shall be capable of user selectable bandwidths.
7. Shall have user selectable cell size and cells can be divided into columns.
8. Shall have a minimum depth rating of 300m.
9. Shall include sensors.
a. Shall have pitch and roll sensor with pitch range ±90°, roll range ±180°, and resolution 0.1°.
b. Shall have compass with 3-axis and tilt compensation.
10. Shall have minimum profile parameters for velocity:
a. Shall be capable if accuracy at ±0.3cm/s or better.
b. Shall be capable of resolution at 0.1cm/s or better.
c. Shall be capable of range from 0m/s to ±1000m/s.
d. Shall have ping rate up to 10Hz.
11. Shall have minimum echo intensity profile with dynamic range greater than 50dB, precision at less than 0.1dB, and resolution at less than 0.1dB
12. Shall have a minimum beam angle of 25°.
13. Shall have 4 beams.
14. Shall not have built in datalogger; but, shall be compatible with datalogger specs below.
1 EA, Datalogger:
15. Shall be compatible with ADCP specified above.
16. Shall communicate by PakBus, Modbus, DNP3, SDI-12, and SDM.
17. Shall have at least 4MB of SRAM for usage and storage.
18. Shall support FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, and NTP protocols.
19. Must be capable of interfacing with an existing CR1000 Datalogger.
1 EA, Power Upgrade:
20. Shall be compatible with ADCP specified above and existing floating pontoon profiler.
21. Shall be solar power system.
22. Shall include two (2) 60 Watt panels, two (2) solar panel mounts, one (1) solar regulator, and one (1) 12v/100ah battery.
1 EA, Mounting System for ADCP:
23. Shall mount the ADCP, specs above, to the existing floating pontoon profiler allowing the ADCP to look down into the water column.
1 EA, Integration and Programing:
24. Vendor shall configure datalogger with ADCP, specified above.
1 EA, Install and Training:
25. Shall install ADCP, datalogger, and solor panel system onto existing pontoon, specs listed above.
26. Shall be 3-day training on the ADCP system.