A06_Pricing_Schedule_CACO_HVAC.docx
DOCX document 22 KB Posted
- Attached to
- CACO-PLVC HVAC ALTERATION Federal contract opportunity
- Solicitation number
- 140P4323Q0060
About this file
This document provides the pricing schedule for repairs and upgrades to the heating, ventilation, and air conditioning (HVAC) system at the Province Land Visitor Center (PLVC) for the National Park Service Northeast Region. The base work consists of repairs to an existing air handler and unit heaters, removal and replacement of damaged equipment, and ductwork and piping repairs. Optional work includes provision of a graphical interface for building management, a variable refrigerant flow central controller with BACnet IP connectivity, and replacement of an existing pneumatic control system with direct digital controls. Pricing is requested as lump sums for the base work and individual options, to be totaled at the bottom. The related federal contract opportunity is solicitation number 140P4323Q0060 for HVAC alterations at the CACO PLVC, to be awarded by the Department of the Interior National Park Service Northeast Region.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P4323Q0060_Amd_0004.pdf | ||
| A05_PWS_CACO_HVAC_0003.pdf | ||
| Sol_140P4323Q0060_Amd_0003.pdf | ||
| Sol_140P4323Q0060_Amd_0002.pdf | ||
| Sol_140P4323Q0060_Amd_0001.pdf | ||
| Amd0001-Additional-Bldg-Attachment_A_0001.pdf | ||
| CACO_WD_2015-4045-rev_25_5_11_23.pdf | ||
| A06_M-3.pdf | ||
| A06_M-4.pdf | ||
| A06_M-2.pdf | ||
| A06_E-2.pdf | ||
| A06_E-1.pdf | ||
| A06_T-1.pdf | ||
| Sol_140P4323Q0060.pdf | ||
| A06_M-1.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CACO HVAC
Pricing Schedule
| Base: |
| Provide all supervision, labor, materials, and equipment to provide repairs to the Province Land Visitor Heating System. Work consists of the following: 1. Repairs existing air handler, AHU-1; 2. Remove two failed hot water unit heaters and replace with new; 3. Remove damaged constant volume box, coil and associated piping designated HC-2; 4. Patch, repair and insulate ductwork and piping at former HC-2 location; 5. Remove damaged constant volume box HC-1; 6. Patch, repair and insulate ductwork and piping at former HC-1 location; 7. provide one, 3 ZONE, ductless, compact, air conditioning and heating VRF system. Unit shall be 48,000BTU cooling and 54,000BTU heating with three (3) wall mounted indoor units; 8. Provide new 100amp, 208/120 volt, 3phase, 4 wire panelboard to replace LP-1; 9. Provide new 400amp, 3phase, 4 wire, MLO panel to replace wireway, conductors and disconnects. |
| Option 1: |
| Provide graphical front end for managing building and BAS (Building Automation System) building controllers across the park. Users access via a new web interface. System shall operate as a Microsoft Windows® application and uses Microsoft SQL Server® for data storage. The province land visitor center shall be assigned its own virtual web and application server. BAS applications shall operate from an installation “on-Premises Server”. |
| Option 2: |
| Provide VRF central controller with BACnet IP card, programming, and system graphics. |
| $ |
| Option 3: |
| Decommission existing pneumatic controls and replace existing pneumatic system with a new Building Automation System with direct digital control for province land visitor HVAC system in accordance with this statement of work and drawings. |
| Total Base + Option 1 + Option 2 + Option 3 = |
| $ |