A06_Pricing_Schedule_CACO_HVAC.docx

DOCX document 22 KB Posted

Attached to
CACO-PLVC HVAC ALTERATION Federal contract opportunity
Solicitation number
140P4323Q0060
Issued by
Department of the Interior National Park Service Northeast Region

About this file

This document provides the pricing schedule for repairs and upgrades to the heating, ventilation, and air conditioning (HVAC) system at the Province Land Visitor Center (PLVC) for the National Park Service Northeast Region. The base work consists of repairs to an existing air handler and unit heaters, removal and replacement of damaged equipment, and ductwork and piping repairs. Optional work includes provision of a graphical interface for building management, a variable refrigerant flow central controller with BACnet IP connectivity, and replacement of an existing pneumatic control system with direct digital controls. Pricing is requested as lump sums for the base work and individual options, to be totaled at the bottom. The related federal contract opportunity is solicitation number 140P4323Q0060 for HVAC alterations at the CACO PLVC, to be awarded by the Department of the Interior National Park Service Northeast Region.

View the file

Other files for this federal contract opportunity

Other files attached to CACO-PLVC HVAC ALTERATION, newest first.
File Type Posted
Sol_140P4323Q0060_Amd_0004.pdf PDF
A05_PWS_CACO_HVAC_0003.pdf PDF
Sol_140P4323Q0060_Amd_0003.pdf PDF
Sol_140P4323Q0060_Amd_0002.pdf PDF
Sol_140P4323Q0060_Amd_0001.pdf PDF
Amd0001-Additional-Bldg-Attachment_A_0001.pdf PDF
CACO_WD_2015-4045-rev_25_5_11_23.pdf PDF
A06_M-3.pdf PDF
A06_M-4.pdf PDF
A06_M-2.pdf PDF
A06_E-2.pdf PDF
A06_E-1.pdf PDF
A06_T-1.pdf PDF
Sol_140P4323Q0060.pdf PDF
A06_M-1.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CACO HVAC

Pricing Schedule

Base:
Provide all supervision, labor, materials, and equipment to provide repairs to the Province Land Visitor Heating System. Work consists of the following: 1. Repairs existing air handler, AHU-1; 2. Remove two failed hot water unit heaters and replace with new; 3. Remove damaged constant volume box, coil and associated piping designated HC-2; 4. Patch, repair and insulate ductwork and piping at former HC-2 location; 5. Remove damaged constant volume box HC-1; 6. Patch, repair and insulate ductwork and piping at former HC-1 location; 7. provide one, 3 ZONE, ductless, compact, air conditioning and heating VRF system. Unit shall be 48,000BTU cooling and 54,000BTU heating with three (3) wall mounted indoor units; 8. Provide new 100amp, 208/120 volt, 3phase, 4 wire panelboard to replace LP-1; 9. Provide new 400amp, 3phase, 4 wire, MLO panel to replace wireway, conductors and disconnects.
Option 1:
Provide graphical front end for managing building and BAS (Building Automation System) building controllers across the park. Users access via a new web interface. System shall operate as a Microsoft Windows® application and uses Microsoft SQL Server® for data storage. The province land visitor center shall be assigned its own virtual web and application server. BAS applications shall operate from an installation “on-Premises Server”.
Option 2:
Provide VRF central controller with BACnet IP card, programming, and system graphics.
$
Option 3:
Decommission existing pneumatic controls and replace existing pneumatic system with a new Building Automation System with direct digital control for province land visitor HVAC system in accordance with this statement of work and drawings.