This document outlines requirements for the overhaul of U.S. Coast Guard Belfort Wind Speed Indicators. The contractor will be responsible for receiving, disassembling, inspecting, testing, repairing, reassembling, preserving, packaging, and shipping the indicators. All work must be done according to original equipment manufacturer procedures and specifications. The contractor must provide status reports and documentation throughout the process. The indicators will be repaired to like-new condition and undergo dynamic testing before being cleaned, packaged in individual boxes with foam cushioning, marked with shipping information, and returned to the Coast Guard Surface Forces Logistics Center. The contractor must follow quality control requirements and use new, original parts for any repairs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 9947 RD A.pdf | ||
| SOLICITATION 70Z08523Q39026B00.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OVERHAUL DESCRIPTION
FOR OFFICIAL USE ONLY
ITEM NAME INDICATOR,WIND DIRECTION AND SPEED
STOCK NUMBER 6660-01-133-9740
PART NUMBER 2411930-18
USED ON VARIOUS US COAST GUARD CUTTERS
Items as received by the contractor must be complete and of the proper cited part number. Discrepancies shall be reported to the Coast Guard Contracting Officer.
OVERHAUL REQUIREMENTS:
1.0 SCOPE
1.1. This document sets forth the requirements for the receipt, disassembly, inspections, condition/test reports, repair/overhaul, reassembly, testing, preservation, packaging, packing, and marking of U.S. Coast Guard Belfort Wind Speed Indicators.
1.2. Government Furnished Property (GFP) - NSN 6660-01-133-9740, p/n 2411930- 18, Wind Speed Indicator
a. The Contractor shall immediately notify the Coast Guard Contracting Officer if the make, model or part number delivered for overhaul does not conform to the Wind Speed Indicator above.
2.0 APPLICABLE DOCUMENTS
2.1. General - The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed.
2.2. Government Documents - The following specifications and standards form a part of this specification to the extent specified herein. Unless otherwise specified, the documents listed here by number and date shall be those in the current Department of Defense Single Stock Point of Specification and Standards (DODSSP) and supplements thereto.
a. United States Coast Guard USCG-SFLC Specification D-000-0100 Rev G Dated 06/2006, Bar Coding for USCG Surface Forces Logistics Center Material.
2.3. Commercial Documents - The following documents form a part of this specification to the extent specified herein. The documents shall be the version listed by number and date from the referenced industry organization.
a. American Society for Testing & Materials (ASTM) D3951-18, dated 11/12/2018, Standard Practice for Commercial Packaging
2.4. Specification Order of Precedence - In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.
3.0 REQUIREMENTS
3.1. General - Inspections, repair/overhaul and testing of each Wind Speed Indicator shall be accomplished in accordance with the Original Equipment Manufacturer (OEM) procedures, specifications, references and standard practices.
a. The repair/overhaul requirements described herein are considered the minimum necessary and are not intended to replace any procedures, controls, examinations, or tests normally employed by the Contractor to assure the quality of the product. The overhaul of the Wind Speed Indicator is intended to return the unit's performance to like new condition.
3.2. Overhaul - The Contractor shall provide all labor and materials to perform the repairs/overhaul services as described below for each Wind Speed Indicator. The overhaul shall include disassembly and cleaning to remove all contaminants including dirt, grease, corrosion and oil.
3.3. Preliminary disassembly, inspection and cleaning of each Wind Speed Indicator shall be conducted in accordance with OEM procedures, specifications, references and standard practices to determine the total estimated cost to repair including material, labor, testing, Preservation, Packaging, Packing and Marking (PPP&M) costs.
a. The degree of disassembly shall be commensurate with the level of repair/overhaul required. Cleaning shall be accomplished prior to or during the preliminary inspection and disassembly, whichever is deemed more practical by the Contractor. Final cleaning shall be conducted to ensure the components are free of obvious defects, soil, grease, residue, fingerprints, perspiration and other acid or alkali residues and treated for corrosion protection. All temporary markings and tags, to include the CG-5236 Serviceable/Unserviceable Tag shall be removed.
3.4. Cost Estimate - A detailed cost estimate shall be submitted to the Coast Guard Contracting Officer for review and approval prior to the start of any repair or order of material. The Contractor shall also provide the replacement cost (and manufacturing lead time) of an identical new Wind Speed Indicator for comparison to the overhaul cost. At a minimum, all parts that are worn, have an improper fit and or damaged beyond the OEM tolerances, shall be repaired or replaced as determined by the Contractor.
a. The detailed cost estimate shall contain the following as a minimum:
1) The part number, NSN and serial number of each Wind Speed Indicator.
2) The contract number for each Wind Speed Indicator.
3) A listing of individual parts by part number, cost and quantity
4) A listing of labor hours and labor rate to perform the overhaul, testing, and PPP&M
5) A recommendation and associated cost to renew the paint on any surface that has experienced paint failure. Painting just to restore cosmetics is not required.
6) The cost of an identical new Wind Speed Indicator (see section 3.5.a. of this specification)
b. Upon acceptance of the cost estimate and authorization to proceed by the Contracting Officer, the Contractor shall repair/overhaul the Wind Speed Indicator in accordance with the OEM procedures, specifications, references, standard practices and the references cited in section 2.0 of this specification.
SHELF LIFE CD 0
1.0 SCOPE
1.1. This document sets forth the requirements for the receipt, disassembly, inspections, condition/test reports, repair/overhaul, reassembly, testing, preservation, packaging, packing, and marking of U.S. Coast Guard Belfort Wind Speed Indicators.
1.2. Government Furnished Property (GFP) - NSN 6660-01-133-9740, p/n 2411930- 18, Wind Speed Indicator
a. The Contractor shall immediately notify the Coast Guard Contracting Officer if the make, model or part number delivered for overhaul does not conform to the Wind Speed Indicator above.
2.0 APPLICABLE DOCUMENTS
2.1. General - The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed.
2.2. Government Documents - The following specifications and standards form a part of this specification to the extent specified herein. Unless otherwise specified, the documents listed here by number and date shall be those in the current Department of Defense Single Stock Point of Specification and Standards (DODSSP) and supplements thereto.
a. United States Coast Guard USCG-SFLC Specification D-000-0100 Rev G Dated 06/2006, Bar Coding for USCG Surface Forces Logistics Center Material.
2.3. Commercial Documents - The following documents form a part of this specification to the extent specified herein. The documents shall be the version listed by number and date from the referenced industry organization.
a. American Society for Testing & Materials (ASTM) D3951-18, dated 11/12/2018, Standard Practice for Commercial Packaging
2.4. Specification Order of Precedence - In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.
3.0 REQUIREMENTS
3.1. General - Inspections, repair/overhaul and testing of each Wind Speed Indicator shall be accomplished in accordance with the Original Equipment Manufacturer (OEM) procedures, specifications, references and standard practices.
a. The repair/overhaul requirements described herein are considered the minimum necessary and are not intended to replace any procedures, controls, examinations, or tests normally employed by the Contractor to assure the quality of the product. The overhaul of the Wind Speed Indicator is intended to return the unit's performance to like new condition.
3.2. Overhaul - The Contractor shall provide all labor and materials to perform the repairs/overhaul services as described below for each Wind Speed Indicator. The overhaul shall include disassembly and cleaning to remove all contaminants including dirt, grease, corrosion and oil.
3.3. Preliminary disassembly, inspection and cleaning of each Wind Speed Indicator shall be conducted in accordance with OEM procedures, specifications, references and standard practices to determine the total estimated cost to repair including material, labor, testing, Preservation, Packaging, Packing and Marking (PPP&M) costs.
a. The degree of disassembly shall be commensurate with the level of repair/overhaul required. Cleaning shall be accomplished prior to or during the preliminary inspection and disassembly, whichever is deemed more practical by the Contractor. Final cleaning shall be conducted to ensure the components are free of obvious defects, soil, grease, residue, fingerprints, perspiration and other acid or alkali residues and treated for corrosion protection. All temporary markings and tags, to include the CG-5236 Serviceable/Unserviceable Tag shall be removed.
3.4. Cost Estimate - A detailed cost estimate shall be submitted to the Coast Guard Contracting Officer for review and approval prior to the start of any repair or order of material. The Contractor shall also provide the replacement cost (and manufacturing lead time) of an identical new Wind Speed Indicator for comparison to the overhaul cost. At a minimum, all parts that are worn, have an improper fit and or damaged beyond the OEM tolerances, shall be repaired or replaced as determined by the Contractor.
a. The detailed cost estimate shall contain the following as a minimum:
1) The part number, NSN and serial number of each Wind Speed Indicator.
2) The contract number for each Wind Speed Indicator.
3) A listing of individual parts by part number, cost and quantity
4) A listing of labor hours and labor rate to perform the overhaul, testing, and PPP&M
5) A recommendation and associated cost to renew the paint on any surface that has experienced paint failure. Painting just to restore cosmetics is not required.
6) The cost of an identical new Wind Speed Indicator (see section 3.5.a. of this specification)
b. Upon acceptance of the cost estimate and authorization to proceed by the Contracting Officer, the Contractor shall repair/overhaul the Wind Speed Indicator in accordance with the OEM procedures, specifications, references, standard practices and the references cited in section 2.0 of this specification.
3.5. Beyond Economical Repair (BER) - The Coast Guard Contracting Officer will determine the disposition of any Wind Speed Indicator delivered for overhaul that is BER.
a. If the Wind Speed Indicator is BER, the government reserves the right to purchase an identical new Wind Speed Indicator from the Contractor.
3.6. Parts - All replacement parts utilized in the overhaul shall be new OEM parts. Reclaimed, recycled or aftermarket parts are not acceptable and shall not be used. Commercial parts such as seals and bearings which are not manufactured by the Wind Speed Indicator manufacturer, shall be identified by their markings or through the use of the technical manual for identification purposes. Commercially available items such as these are generally interchangeable between different manufacturers and may be substituted as long as they are equal in all respects.
3.7. Testing and Certification - After completion of the repairs/overhaul, the Contractor shall conduct a dynamic test of each Wind Speed Indicator to assure maximum design performance. This dynamic test shall be accomplished using a fully operational equipment mock-up. The qualifying performance standard for each Wind Speed Indicator shall be documented and conform to the OEM requirements. Any Wind Speed Indicator that fails to meet the minimum performance parameters shall be investigated, corrected, re-tested and documented.
a. The Contractor shall provide a test report of the successful dynamic test and certification to the Contracting Officer and one copy of the report and certification shall be placed in the shipping container of each respective Wind Speed Indicator.
1) At a minimum, the test report shall contain the following information:
(a) Contractor's name
(b) Contract number
(c) Wind Speed Indicator model and serial number
(d) Date of test
(e) Description of each test conducted and results of each test
(f) Minimum/maximum parameters for each test conducted
(g) Name of the person conducting the testing
3.8. Painting - At the completion of all tests, the Wind Speed Indicator shall be thoroughly cleaned and painted if recommended and approved.
3.9. Installation Instructions - A copy of the OEM installation/alignment, parts and service manual shall be placed inside each Wind Speed Indicator shipping container.
3.10. Photo Documentation - The Contractor shall provide digital photo documentation to the Contracting Officer as follows:
a. When significant findings that will affect cost of repair/overhaul or time are discovered.
b. When other significant or unusual findings such as failed parts or damages are discovered.
c. The photo documentation shall be color digital and shall be sent to the Contracting Officer and the Contracting Officer's Representative via email.
3.11. Status Report - The Contractor shall submit a bi-weekly (every other week) status report on an excel spreadsheet via email to the Contracting Officer and the Contracting Officer's Representative. All Wind Speed Indicators shall be listed with the current repair status. The excel spreadsheet shall contain the following column headings.
a. Part number
b. Serial number
c. National Stock Number (NSN)
d. Date Wind Speed Indicator was received
e. Date Wind Speed Indicator detailed cost estimate sent (section 3.4. of this specification)
f. Date Wind Speed Indicator shipped
g. Comments/remarks
4.0 QUALITY ASSURANCE
4.1. General - The Contractor shall maintain an inspection system which shall insure that each item offered to the Coast Guard for acceptance or approval conforms to the contract requirements. The inspection system shall be documented and available for review by the Coast Guard.
4.2. Records - The Contractor shall maintain records of all inspections and tests. The records, at a minimum, shall indicate the nature and number of observations made, the number and type of deficiencies found, and the corrective action taken.
4.3. Calibration System - The Contractor, as well as any subcontractors, shall be required to maintain a test equipment calibration program. The program shall be documented and traceable to the National Institute of Standards (NIST).
4.4. Responsibility for Inspection - The Contractor shall be responsible for the performance of all inspection requirements specified herein. The Contractor shall provide space, personnel, and test equipment to conduct all required inspections. All inspection and testing shall be performed at the Contractor's plant or at other facilities acceptable to the Coast Guard. The Coast Guard reserves the right to verify or have performed any of the inspections or tests that are deemed necessary to assure that supplies and services conform to the prescribed requirements.
4.5. Responsibility for Compliance - All items shall meet the provisions of sections 3 & 5 of this specification. The inspections set forth in this specification shall become part of the Contractor's overall inspection system or quality program. The absence of any inspection requirements in this specification shall not relieve the Contractor of the responsibility of
3.5. Beyond Economical Repair (BER) - The Coast Guard Contracting Officer will determine the disposition of any Wind Speed Indicator delivered for overhaul that is BER.
a. If the Wind Speed Indicator is BER, the government reserves the right to purchase an identical new Wind Speed Indicator from the Contractor.
3.6. Parts - All replacement parts utilized in the overhaul shall be new OEM parts. Reclaimed, recycled or aftermarket parts are not acceptable and shall not be used. Commercial parts such as seals and bearings which are not manufactured by the Wind Speed Indicator manufacturer, shall be identified by their markings or through the use of the technical manual for identification purposes. Commercially available items such as these are generally interchangeable between different manufacturers and may be substituted as long as they are equal in all respects.
3.7. Testing and Certification - After completion of the repairs/overhaul, the Contractor shall conduct a dynamic test of each Wind Speed Indicator to assure maximum design performance. This dynamic test shall be accomplished using a fully operational equipment mock-up. The qualifying performance standard for each Wind Speed Indicator shall be documented and conform to the OEM requirements. Any Wind Speed Indicator that fails to meet the minimum performance parameters shall be investigated, corrected, re-tested and documented.
a. The Contractor shall provide a test report of the successful dynamic test and certification to the Contracting Officer and one copy of the report and certification shall be placed in the shipping container of each respective Wind Speed Indicator.
1) At a minimum, the test report shall contain the following information:
(a) Contractor's name
(b) Contract number
(c) Wind Speed Indicator model and serial number
(d) Date of test
(e) Description of each test conducted and results of each test
(f) Minimum/maximum parameters for each test conducted
(g) Name of the person conducting the testing
3.8. Painting - At the completion of all tests, the Wind Speed Indicator shall be thoroughly cleaned and painted if recommended and approved.
3.9. Installation Instructions - A copy of the OEM installation/alignment, parts and service manual shall be placed inside each Wind Speed Indicator shipping container.
3.10. Photo Documentation - The Contractor shall provide digital photo documentation to the Contracting Officer as follows:
a. When significant findings that will affect cost of repair/overhaul or time are discovered.
b. When other significant or unusual findings such as failed parts or damages are discovered.
c. The photo documentation shall be color digital and shall be sent to the Contracting Officer and the Contracting Officer's Representative via email.
3.11. Status Report - The Contractor shall submit a bi-weekly (every other week) status report on an excel spreadsheet via email to the Contracting Officer and the Contracting Officer's Representative. All Wind Speed Indicators shall be listed with the current repair status. The excel spreadsheet shall contain the following column headings.
a. Part number
b. Serial number
c. National Stock Number (NSN)
d. Date Wind Speed Indicator was received
e. Date Wind Speed Indicator detailed cost estimate sent (section 3.4. of this specification)
f. Date Wind Speed Indicator shipped
g. Comments/remarks
4.0 QUALITY ASSURANCE
4.1. General - The Contractor shall maintain an inspection system which shall insure that each item offered to the Coast Guard for acceptance or approval conforms to the contract requirements. The inspection system shall be documented and available for review by the Coast Guard.
4.2. Records - The Contractor shall maintain records of all inspections and tests. The records, at a minimum, shall indicate the nature and number of observations made, the number and type of deficiencies found, and the corrective action taken.
4.3. Calibration System - The Contractor, as well as any subcontractors, shall be required to maintain a test equipment calibration program. The program shall be documented and traceable to the National Institute of Standards (NIST).
4.4. Responsibility for Inspection - The Contractor shall be responsible for the performance of all inspection requirements specified herein. The Contractor shall provide space, personnel, and test equipment to conduct all required inspections. All inspection and testing shall be performed at the Contractor's plant or at other facilities acceptable to the Coast Guard. The Coast Guard reserves the right to verify or have performed any of the inspections or tests that are deemed necessary to assure that supplies and services conform to the prescribed requirements.
4.5. Responsibility for Compliance - All items shall meet the provisions of sections 3 & 5 of this specification. The inspections set forth in this specification shall become part of the Contractor's overall inspection system or quality program. The absence of any inspection requirements in this specification shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the government for acceptance comply with all requirements of the contract. Sampling for quality conformance does not authorize submission of known defective material (either indicated or actual) nor does it commit the government to acceptance of defective material.
4.6. Quality Assurance - The Contractor shall maintain an inspection system which shall insure that each item offered to the Coast Guard for acceptance or approval conforms to the contract. The inspection system shall be documented and available for review by the Coast Guard.
4.7. Test & Inspections - The inspections/tests required here and in the appropriate subsection in section 3.0. of this specification, are the minimum required and are not intended to supplant any controls, examination, inspections or tests normally employed by the Contractor to assure the quality of the item in question.
a. The following inspections are required.
1) Dynamic test and certification (section 3.7. of this specification)
2) Verify OEM installation/alignment, parts and service manual (section 3.9.
of this specification)
3) Verify PPP&M requirements (section 5.0 of this specification)
5.0 PRESERVATION, PACKING, PACKAGING & MARKING
5.1. Preservation - A repaired/overhauled Wind Speed Indicator is typically intended for warehouse storage and not for immediate installation. Therefore, it is critical that the Contractor ensure that the repaired/overhauled Wind Speed Indicator be prepared for long term storage.
5.2. Packing - Each Wind Speed Indicator shall be individually packed in its own container. Minimum acceptable is doubled walled cardboard.
5.3. Packaging - Each Wind Speed Indicator shall be cushioned with form fitting foam cushioning material capable of protecting the Wind Speed Indicator from damage during multiple shipments by commercial carrier (section 2.3.a. of this specification).
5.4. Marking - Each preserved and packed Wind Speed Indicator shall be marked in the upper left-hand side of the two longest sides (two opposite sides if square) of each box. The marking shall be 14 font minimum characters on a white background. NOTE: ALL PREVIOUS MARKINGS AND QUALITY ASSURANCE DECALS
SHALL BE REMOVED FROM A REUSABLE SHIPPING CONTAINER PRIOR TO THE APPLICATION
OF ANY NEW MARKINGS.
a. This marking shall consist of the STOCK NUMBER, ITEM NAME, PART NUMBER, CONTRACT NUMBER, GROSS WEIGHT (in lbs.), condition code CONDITION "A", unit of issue with quantity (i.e. 1-EA), and the words COAST GUARD SFLC MATERIAL.
STOCK NUMBER 6660-01-133-9740
ITEM NAME Indicator, Wind Direction PART NUMBER 2411930-18 CONTRACT NUMBER See Contract
SHIPPING WEIGHT AS DETERMINED BY CONTRACTOR CONDITION CODE CODITION "A"
QUANTITY & UNIT OF ISSUE 1 - EACH
COAST GUARD SFLC MATERIAL, REUSABLE SHIPPING CONTAINER DO NOT DESTROY
FRAGILE, SENSITIVE ELECTRONIC EQUIPMENT ENCLOSED
5.5. Bar Coding - The Contractor shall supply bar code labels on all CLIN"s except for those that require data submissions only.
a. All bar code labels shall be in accordance with SFLC specification D-000- 0100 Rev G.
1) The actual labels shall be Type "V". Grade "a", Style "2", Composition "b"
2) Each label shall contain encoded data for the Stock Number.
6.0 NOTES
6.1. Government & Commercial Document Services
a. Government Documents
1) Department of Defense Single Stock Point (DODSSP Documents) 700 Robbins Avenue Building #4, Section D Philadelphia, PA 19111-5098
FAX (215) 697-9398
http://dodssp.daps.dla.mil/
2) DOD & Navy Publications and Forms (Other Than DODISS) Naval Publication and Forms Center 5801 Tabor Ave.
Philadelphia, PA. 19120 215-697-2197
3) USCG Surface Forces Logistics Center Long Range Enforcer Product Line Mail Stop 26, Bldg. 3, 2nd Floor, CPD-2 2401 Hawkins Point Road Baltimore, MD 21226-5000 410-762-XXXX
b. Commercial Documents
1) American Society for Testing & Materials (ASTM) 1916 Race Street Philadelphia PA. 19103-1187 215-299-5585
FAX 215-977-9679
assuring that all products or supplies submitted to the government for acceptance comply with all requirements of the contract. Sampling for quality conformance does not authorize submission of known defective material (either indicated or actual) nor does it commit the government to acceptance of defective material.
4.6. Quality Assurance - The Contractor shall maintain an inspection system which shall insure that each item offered to the Coast Guard for acceptance or approval conforms to the contract. The inspection system shall be documented and available for review by the Coast Guard.
4.7. Test & Inspections - The inspections/tests required here and in the appropriate subsection in section 3.0. of this specification, are the minimum required and are not intended to supplant any controls, examination, inspections or tests normally employed by the Contractor to assure the quality of the item in question.
a. The following inspections are required.
1) Dynamic test and certification (section 3.7. of this specification)
2) Verify OEM installation/alignment, parts and service manual (section 3.9.
of this specification)
3) Verify PPP&M requirements (section 5.0 of this specification)
5.0 PRESERVATION, PACKING, PACKAGING & MARKING
5.1. Preservation - A repaired/overhauled Wind Speed Indicator is typically intended for warehouse storage and not for immediate installation. Therefore, it is critical that the Contractor ensure that the repaired/overhauled Wind Speed Indicator be prepared for long term storage.
5.2. Packing - Each Wind Speed Indicator shall be individually packed in its own container. Minimum acceptable is doubled walled cardboard.
5.3. Packaging - Each Wind Speed Indicator shall be cushioned with form fitting foam cushioning material capable of protecting the Wind Speed Indicator from damage during multiple shipments by commercial carrier (section 2.3.a. of this specification).
5.4. Marking - Each preserved and packed Wind Speed Indicator shall be marked in the upper left-hand side of the two longest sides (two opposite sides if square) of each box. The marking shall be 14 font minimum characters on a white background. NOTE: ALL PREVIOUS MARKINGS AND QUALITY ASSURANCE DECALS
SHALL BE REMOVED FROM A REUSABLE SHIPPING CONTAINER PRIOR TO THE APPLICATION
OF ANY NEW MARKINGS.
a. This marking shall consist of the STOCK NUMBER, ITEM NAME, PART NUMBER, CONTRACT NUMBER, GROSS WEIGHT (in lbs.), condition code CONDITION "A", unit of issue with quantity (i.e. 1-EA), and the words COAST GUARD SFLC MATERIAL.
STOCK NUMBER 6660-01-133-9740
ITEM NAME Indicator, Wind Direction PART NUMBER 2411930-18 CONTRACT NUMBER See Contract
SHIPPING WEIGHT AS DETERMINED BY CONTRACTOR CONDITION CODE CODITION "A"
QUANTITY & UNIT OF ISSUE 1 - EACH
COAST GUARD SFLC MATERIAL, REUSABLE SHIPPING CONTAINER DO NOT DESTROY
FRAGILE, SENSITIVE ELECTRONIC EQUIPMENT ENCLOSED
5.5. Bar Coding - The Contractor shall supply bar code labels on all CLIN"s except for those that require data submissions only.
a. All bar code labels shall be in accordance with SFLC specification D-000- 0100 Rev G.
1) The actual labels shall be Type "V". Grade "a", Style "2", Composition "b"
2) Each label shall contain encoded data for the Stock Number.
6.0 NOTES
6.1. Government & Commercial Document Services
a. Government Documents
1) Department of Defense Single Stock Point (DODSSP Documents) 700 Robbins Avenue Building #4, Section D Philadelphia, PA 19111-5098
FAX (215) 697-9398
http://dodssp.daps.dla.mil/
2) DOD & Navy Publications and Forms (Other Than DODISS) Naval Publication and Forms Center 5801 Tabor Ave.
Philadelphia, PA. 19120 215-697-2197
3) USCG Surface Forces Logistics Center Long Range Enforcer Product Line Mail Stop 26, Bldg. 3, 2nd Floor, CPD-2 2401 Hawkins Point Road Baltimore, MD 21226-5000 410-762-XXXX
b. Commercial Documents
1) American Society for Testing & Materials (ASTM) 1916 Race Street Philadelphia PA. 19103-1187 215-299-5585
FAX 215-977-9679
WARRANTY:
X A. Standard Manufacturer's Warranty
B. Item being repaired as an "onboard repair" or a "system stock" item and will be put into inventory. NOT FOR IMMEDIATE INSTALLATION.
Contractor must guarantee item against defects that lead to failure for days after installation for a period of up to two (2) years after delivery to Coast Guard.
GOVERNMENT ACCEPTANCE:
Acceptance will be made at destination by a Government representative.
Acceptance will be contingent upon the representative's verification of no damage in transit, correctness and completeness of order and contractor's conformance to preservation/packaging, packing and marking requirements.
PACKAGING AND MARKING FOR SHIPMENT:
X A. Each unit shall be packed individually in it's own wooden box which shall be capable of providing adequate protection to the item during multiple shipments. Mark each box in legible black print lettering with the following information:
NATIONAL STOCK NUMBER
ITEM NAME
PART NUMBER
GOVERNMENT ORDER NUMBER
6660-01-133-9740
INDICATOR,WIND DIRECTION AND SPEED
2411930-18
PRESERVATION / PACKAGING:
X A. Each unit shall be individually preserved and wrapped for protection against deterioration for a period of two (2) years minimum.
B. See Attachments
B. See Attachments
And the words: "Coast Guard SFLC Material, Condition "A"