This document is a Vacuum Chamber Specification for a 16" cube vacuum chamber to be integrated with a Shape Memory Alloy Low Temperature Characterization Rig. The chamber must be capable of operating down to 10^-6 torr and have multiple conflat interfaces to accommodate various test equipment. Key requirements include fabrication from 300 series stainless steel or 6061-T6 aluminum, a 5.25" x 5.25" or 6" diameter viewport window, and a 12-month manufacturer's warranty.

The related federal contract opportunity is Solicitation Number 80NSSC24871318Q, issued by the National Aeronautics and Space Administration Shared Services Center, for a Vacuum Chamber SKU0248807. The solicitation includes a Statement of Work and Request for Quote for the required vacuum chamber.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Vacuum Chamber Specification 1

Shape Memory Alloy Low Temperature Characterization Rig Vacuum Chamber Specification

April 29, 2024

Rev 2

Scope

The scope of this procurement covers a 16” cube vacuum chamber with front swing-out door capable of operating down to 10^-6 torr. The vacuum chamber shall be integrated with the Shape Memory Alloy (SMA) Low Temperature Characterization Rig, which integrates a thermal vacuum chamber with a COTS mechanical test system.

<insert Diagram here>

Purchase Specifications

* See attached drawing ########.pdf for detailed vacuum chamber fabrication requirements. In the case of discrepancy between the product specification detail below and the drawing, the drawing requirements take precedence.

1) Equipment: Vacuum chamber

2) Order Qty: 1 vacuum chamber

3) Product Description: 16” x 16” x 16” cube vacuum chamber with front swing-out door and multiple conflat interfaces to accommodate mechanical tester feedthroughs, cryocooler, and electrical instrumentation.

4) Warranty: Vendor shall provide manufacturer’s warranty on parts of not less than 12 months from time of delivery

5) Vacuum operating pressure: 10^-6 Torr or better

6) Max operating pressure: 0 psig

7) Operating temperature: Ambient temp (60-70F)

8) Materials Vessel shall be fabricated from either 300 series stainless steel or 6061-T6 Aluminum.

Vacuum Chamber Specification 2

9) Flange requirements:

a) Top chamber panel: Qty 1, 10” conflat flange, fixed, through-hole Qty 2, 6.75” conflat flanges, fixed, through-hole

b) Rear chamber panel: Qty 1, 13.25” conflat flange, fixed, through-hole

c) Bottom chamber panel: Qty 1, 10” conflat flange, rotatable, through-hole

d) Lower 10” extrusion: Qty 1, 4.5” conflat flange, fixed, through-hole, on tee branch run

10) Door View Port: The door shall include a 5.25” x 5.25” square or 6” diameter minimum viewport window made of fused silica glass. Window shall have a broad-band anti-reflective coating on both sides that limits reflectivity to <1% per surface over visible spectrum (425nm – 700nm), for incident angles of 0 to 10 degrees.

11) Camera mounting feature: The door shall include blind threaded holes on the swing-out door to accommodate mounting of 80/20 extrusion hardware to support camera. Threaded holes shall utilize heli-coil or equivalent insert and shall not compromise the ability of the door to support atmospheric loading when the chamber is at vacuum.

12) External mounting bosses: The chamber shall include 4 external mounting boss features on the top and bottom chamber panels.

13) Internal mounting bosses: The chamber shall include 4 internal mounting boss features on the bottom chamber panel.

14) Maximum chamber width: The width of the chamber as measured from the outside surface of the left most wall to the outside of the right most wall shall be no greater than 17”. Note, the door frame may be larger. This requirement only applies to the cube chamber body.

15) Fabrication approval: The contractor shall provide detailed drawings for approval.

Fabrication shall not start until the contractor receives drawing approval from NASA.

16) Inspections The contractor shall perform a vacuum test with leak check. The vendor shall verify all dimensional requirements as specified in included drawing.

Vacuum Chamber Specification 3

17) Delivery Destination:

The vendor/supplier shall include in their firm-fixed price cost proposal to the Government, FOB shipping costs of the packaged vacuum chamber to the following location:

NASA Glenn Research Center 21000 Brookpark Rd Bldg 401 Cleveland, OH 44135 Attn: Jason Wendell GRC Contact: Paige Foreman

Note: All conflat flanges shall be capped to protect flange sealing surfaces during shipping and handling.

18) Documentation Deliverables:

The vendor/supplier shall provide at a minimum three (3) copies of the following documentation at time of equipment delivery:

Signed Certification of Compliance (CofC) As-built drawings Analysis showing compliance to operating pressure and temperature (if applicable) Inspection reports including at a minimum vacuum/leak test and dimensional inspections.

NDE Reports (If Applicable)

19) Vendor/Supplier Proposal:

The vendor/supplier shall include in their firm-fixed price response to this solicitation at a minimum the following information:

Fabrication and Delivery schedule Shipping/transportation costs Listing of Vendor supplied Deliverables.

Any exceptions to the above government requirements as listed above in this procurement document.

Optional increased cost for accelerated delivery (< 12 weeks)