SATPC0034162 Tab 04 4 SOW_Redacted.pdf

PDF 123 KB Posted

Attached to
Agilent Cary 4000 UV-Vis Bundle.
Solicitation number
80NSSC24860795Q
Issued by

About this file

This federal notice solicits proposals for an Agilent Cary 4000 UV-Vis Bundle for use at NASA Headquarters. The required equipment includes an Agilent Cary 4000 double beam spectrophotometer with a wavelength range of 190-1100 nm and variable bandwidth capability of 0.5, 1, 2, 5, and 20 nm. Accessories such as temperature-controlled fluid cells, sample cell holders, cylindrical cell holders, and an external diffuse reflectance accessory must also be provided. Installation, necessary hardware, travel costs, labor, and parts for repairs are included. The period of performance is 14 weeks at the University of California San Diego Scripps Institution of Oceanography. Interested parties may submit capabilities by February 8, 2024 to be considered for the sole source contract intended for Agilent Technologies.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

1. Objective/ Requirements

This procurement is for the acquisition of an Agilent Cary 4000 UV-Vis Bundle for use at NASA Headquarters. The required specifics are detailed below:

2. Characteristics, Scope, and Specs

The vendor shall perform the following duties:

• Deliver a new Cary 4000 UV-Vis spectrophotometer, DRA-2500, and other purchased accessories with the following characteristics and performance specifications:

o Double beam spectrophotometer design o Wavelength range of 190-1100 nm o Dual lamp system with Tungsten and Deuterium lamps o Variable spectral bandwidth capability of 0.5, 1, 2, 5, and 20 nm o Internal Quality Assurance/Quality Control testing to meet manufacturing and pharmaceutical requirements o Accommodate a wide range of accessories including

Peltier temperature-controlled fluid cell holder, Sample cell holders of 5, 10, 20, 40, 50, and 100 mm pathlength, Cylindrical cell sample holder with 10 cm pathlength, External Diffuse Reflectance Accessory with 150 mm diameter

• Provide a technical representative to complete installation of the Cary 4000 spectrophotometer.

• Complete installation of spectrophotometer.

• Provide all the necessary hardware for said installation.

• The procurement for this purchase includes any vendor-incurred costs related to travel, labor, and parts for the necessary repairs.

3. Period of Performance

14 Weeks ARO

4. Place of Performance

University of California, San Diego Scripps Institution of Oceanography

Mail Code: 0208 La Jolla, CA 92037 c

File details come from the government source that posted it. Updated .