8.31.2026_Taylor Hoover MS MEP Upgrades_Addendum 001_Combined (1).pdf

PDF 7 MB Posted

Attached to
Hoover Heating/Cooling Bid
Solicitation number
RFP TAY 260000002580 1
Issued by
Michigan

About this file

This Addendum No. 001, dated August 31, 2026, amends the original drawings and specifications for the Taylor Schools Hoover Middle School MEP (Mechanical, Electrical, Plumbing) Upgrades project located at 27101 Beverly Road, Taylor, Michigan 48180, issued by The Collaborative on behalf of the Taylor School District. The project scope encompasses comprehensive HVAC system upgrades including the installation of new rooftop units (RTUs), air handling units (AHUs), heating hot water coils, exhaust fans, relief hoods, and associated ductwork and piping throughout the first floor and roof areas. Key clarifications provided in the addendum address structural support requirements, specifying that steel support is required only for pipe or duct openings larger than 28 inches in diameter, with Simpson Quick Frame systems to be used for all new RTU supports and exhaust fans exceeding 28 inches diameter. The addendum confirms this is a prevailing wage project and corrects the bid bond requirement from 10 percent to 5 percent. Significant drawing revisions documented include modifications to ceiling demolition and reflected ceiling plans to accommodate revised supply and return ductwork, RTU location shifts based on structural snow drift considerations, and adjustments to mechanical systems including changes to energy recovery unit controls and heating coil configurations across multiple building areas.

The addendum comprises four written pages and twenty updated drawings reflecting revisions across architectural, mechanical, and electrical disciplines. Notable changes include the addition of a service platform for RTU-3 under Alternate-2, relocation of RTU-2 per structural requirements, deletion of cooling functionality from AHU-2 in Alternate-2, and modifications to condensate piping and RTU service platform details on newly added sheet M5.01. All existing equipment must remain operational during construction, with coordination required between mechanical, structural, and other trades to ensure proper installation and sequencing. The project requires bidders to acknowledge receipt of this addendum in their bid forms, and all work must proceed in accordance with the contract documents, applicable codes including the 2021 Michigan Building Code and Michigan Mechanical Code, and the engineer's specifications.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

August 31, 2026

ADDENDUM NO. 001

To the Drawings and Specifications for:

Taylor Schools Hoover MS – MEP Upgrades

27101 Beverly Rd

Taylor, MI 48180

107445

Taylor School District

Prepared By:

The Collaborative

Telephone: (419) 242-7405

Fax: (419) 242-7400

Taylor School District

TO ALL BIDDERS:

This addendum supplements and amends the original drawings and specifications, and shall be taken into account in preparing proposals, and shall become a part of the contract documents. Receipt of this Addendum must be acknowledged in the Bid Form.

GENERAL

Question:

Duct penetrations are assumed to have steel support due to size of ductwork penetrations. Can you confirm if we will need to add steel for the following it’s not clear so just looking for clarification if we need to add steel supports for the following. Pipe portals, Exhaust fans, & relief hoods.

Answer:

Only need steel support for pipe or duct openings larger than 28” in diameter. We have the Simpson

Quick frames detail (On the roof plan) to be used for any new RTU supports.

Question:

Confirm if we need to reinforce any joist?

Answer:

Use the Simpson quick frames system below each new unit and SA and RA ducts. Same for any exhaust fans that are greater than 28" diameter up blast.

Clarifications:

1. This is a prevailing wage project

2. A 5% bid bond is required, not a 10% as listed

Drawings

Architectural Drawings

Drawing – D0.1.2 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN – AREA B

Item #1 Ceiling area of work expanded to accommodate supply and return ductwork revisions.

Drawing - A1.1.2 FIRST FLOOR PLAN – AREA B

Item #1 Sheet includes revisions to the floor horizontal mechanical units in the classrooms and adjacent casework. The existing casework and horizontal floor units will be removed. Exposed flooring

Taylor School District will be patched with new matching VCT tile. The existing piping and supply lines to the old units will also be removed and the wall will be finished to match adjacent. The new piping will attach to the new mechanical unit as shown in the mechanical drawings and will be protected with a sheet metal cover.

Any existing marker boards above floor horizontal mechanical unit and casework will be removed and returned to owner as required to install new piping to new mech unit.

Item #2 The existing piping and supply lines to the old units will be removed and the walls will be finished to match existing. The new piping will attach to the new mechanical unit as shown in the mechanical drawings and will be protected with a sheet metal cover. Any existing marker boards above floor horizontal mechanical unit and casework will be removed and returned to owner as required to install new piping to new mech unit.

Drawing - A1.1.7 ROOF PLAN – AREA A

Item #1 Service platform added to RTU-3 (Alternate-2) as indicated in sheet M1.30.

Drawing - A1.1.8 ROOF PLAN – AREA B

Item #1 RTU-2 shifted per structural comments regarding snow drift, as indicated in sheet M1.31.

Drawing - A1.3.2 FIRST FLOOR REFLECTED CEILING PLAN – AREA B

Item #1 Ceiling area of work expanded to accommodate supply and return ductwork revisions.

Mechanical Drawings

Drawing M0.00 – MECHANICAL GENERAL INFORMATION

Sheet 5.01 – Mechanical Details added to sheet index.

Drawing MD1.11 – MECHANICAL DEMOLITION FIRST FLOOR PLAN – UNIT B

Demolition of return ductwork revised to accommodate shift of RTU on new work roof plans.

Removal of thermostat in Media Center added to Alternate-1.

Drawing MD4.20 – ENLARGED MECHANICAL DEMOLITION PLANS - BALCONY

Demolition of supply ductwork revised to accommodate addition on HC-2 on new work plans.

Drawing M1.11 – MECHANICAL NEW WORK FIRST FLOOR PLAN – UNIT B

Supply and return ductwork revised to accommodate shift of RTU on new work roof plans.

Drawing M1.30 – MECHANICAL NEW WORK ROOF PLAN – UNIT A

Service platform added to RTU-3 (Alternate-2), as indicated.

Drawing M1.31 – MECHANICAL NEW WORK ROOF PLAN – UNIT B

RTU-2 (Alternate-1) shifted per structural comments regarding snow drift, as indicated.

Drawing M4.20 – ENLARGED MECHANICAL NEW WORK PLANS - BALCONY

HC-2 added to supply from AHU-2 (Alternate-2), as indicated. Associated supply ductwork and hydronic piping revised accordingly.

Taylor School District

Drawing M5.00 – MECHANICAL DETAILS

Roof gas pipe support detail revised, and heating coil piping diagram (2-way valve) detail removed.

Drawing M5.01 – MECHANICAL DETAILS.

Sheet M5.01 added, including details for RTU condensate piping and RTU service platform.

Drawing M6.01 – MECHANICAL SCHEDULES

“ALTERNATE: INDOOR AIR HANDLING ENERGY RECOVERY UNIT SCHEDULE (HEATING ONLY)”

revised. HC-2 added to “ALTERNATE: HEATING HOT WATER COIL SCHEDULE”.

Drawing M8.01 – MECHANICAL TEMPERATURE CONTROLS

“ENERGY RECOVERY UNIT CONTROL DIAGRAM” and associated sequence of operations revised to remove cooling from AHU-2 (Alternate-2).

Electrical Drawings

Drawing EP1.30

Shifted RTU connections based on mechanical changes.

Drawing EP1.31

Shifted RTU connections based on mechanical changes.

Drawing E4.20

Adjusted wire size for AHU-2 based on mechanical schedule changes.

Drawing E6.01

Adjusted load on breaker for AHU-2 based on mechanical schedule changes.

END OF ADDENDUM NO. 001 (04 Written Pages, 20 Drawings)

1301048954

Michael A.

Muse

N

OWNER JOB NO. ----

ISSUED FOR BIDDING08.11.2026

SHEET TITLE

SHEET NO.

D0.1.2

KEY PLAN

N.T.S.

FIRST FLOOR

DEMOLITION

REFLECTED

CEILING PLAN -

AREA B

Taylor Schools

Hoover Middle School - HVAC Upgrades

27101 Beverly Rd Taylor, MI 48180

TC JOB NO. 107445

ADDENDUM 00108.31.2026

PROJECT TITLE

1. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL

DRAWINGS FOR DEMOLITION SCOPE RELATED TO

EXISTING MEP SYSTEMS.

2. FOR ALL REMOVED FINISHES, FURNISHINGS,

CASEWORK, AND BUILDING ELEMENTS, REMOVE ALL

ASSOCIATED MOUNTING MATERIALS, ADHESIVES,

HARDWARE, AND RELATED ELEMENTS.

3. PATCH ALL DISTURBED SUBSTRATES AT LOCATIONS OF

REMOVED ELEMENTS AS REQUIRED TO CREATE

SMOOTH SURFACES FOR NEW CONSTRUCTION.

DEMOLITION GENERAL NOTES

(NOTE: NOT ALL NUMBERS ARE USED)

C: CEILINGS

C-1: REMOVE ACOUSTICAL PANEL CEILING TILES

TYP IN "HATCHED AREA"

C-2: REMOVE CORRESPONDING GYPSUM BOARD

CEILING SYSTEM FOR WORK.

C-3: REMOVE AND RETAIN CORRESPONDING

ACOUSTICAL PANEL CEILING TILES FOR WORK.

TYP IN "HATCHED AREA"

SEE MECHANICAL DRAWINGS

L: LIGHT FIXTURE

L-1: REMOVE AND RETAIN EXISTING LIGHT FIXTURE

AND COMPONENTS FOR REINSTALLATION

SEE REFLECTED CEILING PLAN

TYP

P: PLUMBING

P-1: REMOVE EXISTING SHOWER FIXTURE

SEE MECHANICAL DRAWINGS

CA: CASEWORK DEMO

CA-D: REMOVE EXISTING CASEWORK AND/OR SHELVING

MECHANICAL (M)

M-D: REMOVE EXISTING MECHANICAL UNIT

SEE MECHANICAL DRAWINGS

DEMOLITION KEYNOTES

ALT

#1

C-1

C-1

C-1

C-1

CL RM

STOR

VEST

GEN OFFICE

WAIT

VAULT

CL RM

CONF

WORK

OFF

AUDIO VIS.

TEACHERS

MEN

BOYS

GIRLS

J.C.

CONF

WAIT

CONF

BOOK

CLINIC

CONSUL

HALL

OFFICE

105A

OFFICE

CL RM

J.C.

BOYS

GIRLS

CL ROOM

MEDIA CENTER

CL RM

TYPING

SPEC. ED

WORK

110-A

ST

TLT

TLT

112A

CORR

VEST

CL RM

CL RM

CL RM

CL RM

OFF

CORR

CL RM

CL RM

CL RM

PREP

OFF

VEST

PREP

CL RM

CL RM

WET RM

CL RM

CL RM

150B

CL RM

150A

VEST

CORR

CL RM

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

CORR

LOBBY

CORR

CORR

CL RM

CL RM

CORR

CORR

C-3C-3

C-3

C-3

C-3

L-1

C-3

C-3C-3C-3

C-1

C-3C-3

C-3C-3C-3C-3

C-3 C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3

C-3 C-3

C-3

A R

E A

B

S E

E S

H E

E T

D 0.

1.

A R

E A

C

S E

E S

H E

E T

D 0.

1.

ALT

#1

C-1 C-1

C-1

C-1 C-1

C-1

C-1

C-1

C-1

WOMEN

MEN

CONS

CONS

TLT

TLT

PRIN

CL RM

CL RM

OFF

MECH-1

MECH-1

MECH-1

MECH-1

MECH-1

MECH-1

MECH-1

MECH-1

MECH-1

MECH-1 MECH-1

MECH-1

MECH-1MECH-1

MECH-1MECH-1

MECH-1MECH-1MECH-1

C-3

CL RM

L-1 L-1 L-1L-1 L-1 L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1L-1L-1

L-1 L-1

L-1 L-1

L-1

REMOVE

ANGLED CEILING

BUILD-OUT

SEE SHEET D0.1.3

REMOVE

ANGLED CEILING

BUILD-OUT

SEE SHEET D0.1.3

L-1

L-1

L-1

L-1

L-1

L-1 L-1

L-1 L-1

L-1

L-1

L-1

L-1

L-1L-1

L-1L-1L-1L-1L-1

L-1L-1

L-1

L-1L-1 L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1 L-1

L-1 L-1

L-1 L-1

PROTECT

FOLDING PARTION

FROM DAMAGE

TYP

PROTECT

FOLDING PARTION

FROM DAMAGE

TYP

PROTECT

FOLDING PARTION

FROM DAMAGE

TYP

PROTECT

FOLDING PARTION

FROM DAMAGE

TYP

L-1

SCALE: 1/8" = 1'-0"A2

FIRST FLOOR DEMOLITION REFLECTED CEILING PLANS - AREA B

A.

Muse

N

OWNER JOB NO. ----

ISSUED FOR BIDDING08.11.2026

SHEET TITLE

SHEET NO.

A1.1.2

KEY PLAN

N.T.S.

FIRST FLOOR

PLAN - AREA B

Taylor Schools

Hoover Middle School - HVAC Upgrades

27101 Beverly Rd Taylor, MI 48180

TC JOB NO. 107445

ADDENDUM 00108.31.2026

PROJECT TITLE

G2 A2.00

D1 A2.00

STOR

J.C.

GIRLS

BOYS

CONS

CONS

CONF

WAIT

CONSUL

CONF

BOOK

CLINIC

TLT

TLT

TLT

VAULT

WAIT

GEN OFFICE

PRIN

LOBBY

VEST

1VEST

OFFICE

105A

OFFICE

105 CL RM CL RM

GIRLS

BOYS

J.C.

MEN

WOMEN

MEN

TEACHERS

AUDIO VIS.

WORK

OFF

HALL

CONF

CL RM

CL ROOM

MEDIA CENTER

CL RM

CORR

VEST

TYPING

SPEC. ED

WORK

110-A

ST

TLT

TLT

112ACORR

PREP

OFF

CL RM

CORR

119 OFF

CORR

CL RM

CL RM

CL RM

116CL RM

CL RM

CL RM

CL RM

CL RM

CORR

CL RM

150A

CORR

VEST

CL RM

WET RM

CL RM

CL RM

PREP

OFF

CL RM

VEST

CL RM

CL RM

M-1

M-1 M-1

M-1 M-1

M-1

M-1

M-1

M-1

M-1

M-1

M-1

M-1

M-1

M-1

VCT-1

VCT-1 VCT-1

VCT-1 VCT-1

VCT-1

VCT-1

VCT-1

VCT-1

A R

E A

B

S E

E S

H E

E T

A 1.

1.

A R

E A

C

S E

E S

H E

E T

A 1.

1.

PLAN GENERAL NOTES:

1. COORDINATE SIZE AND LOCATION OF ALL HOUSEKEEPING

PADS AND/OR EQUIPMENT SUPPORTS WITH APPROPRIATE

EQUIPMENT MANUFACTURER.

2. COORDINATE SIZES AND LOCATIONS OF ALL

MISCELLANEOUS ACCESS PANELS REQUIRED. ACCESS

PANELS ARE SPECIFIED ARCHITECTURALLY BUT ARE TO

BE PROVIDED BY TRADES REQUIRING THEM. ALL

LOCATIONS MUST BE APPROVED BY ARCHITECT PRIOR TO

INSTALLATION.

3. FLOOR PLANS ARE DIMENSIONED TO ACTUAL WALL

THICKNESS UNLESS OTHERWISE NOTED.

4. DIMENSIONS FOLLOWED BY ± MUST BE FIELD REVIEWED

AND ALL NECESSARY ADJUSTMENTS MADE PRIOR TO

FABRICATION AND/OR INSTALLATION OF AFFECTED WORK.

NOTIFY ARCHITECT IF DISCREPANCIES ARISE BEFORE

PROCEEDING WITH THE WORK.

5. VERIFY QUANTITY, SIZES, AND LOCATIONS OF ALL FLOOR,

ROOF, AND WALL OPENINGS FOR MECHANICAL AND

ELECTRICAL WORK WITH THE APPROPRIATE TRADES.

PROVIDE ALL OPENINGS SHOWN OR REQUIRED FOR THE

COMPLETION OF THE WORK. PROVIDE ALL LINTELS

REQUIRED FOR THESE OPENINGS PER SPECIFICATIONS.

MECHANICAL (M):

M-1: NEW MECHANICAL UNIT

SEE MECHANICAL DRAWINGS

ELECTRICAL (E):

COORDINATE WITH ELEC FOR PLACEMENT OF WALL PANELS

SEE ELECTRICAL DRAWINGS

FINISH NOTES:

VINYL COMPOSTION TILE (VCT):

VCT-1: PATCH/INFILL FLOOR AREA FROM DEMOLISHED CABINET &

MECHANICAL FLOOR UNITS W/ NEW VCT TILE

MATCH EXISTING

TYP "GRID HATCHED AREA"

SCALE: 1/8" = 1'-0"A2

FIRST FLOOR PLAN - AREA B

REMOVE EXISTING

FLOOR MECHANICAL UNIT

SEE MECH & FIRST FLOOR

PLAN DRAWINGS

REMOVE EXISTING CASEWORK

AND/OR SHELVING SEE DEMO

MECH & FIRST FLOOR PLAN

DRAWINGS

REMOVE EXISTING MECHANICAL

SHEET METAL COVER

FINISH WALL TO MATCH ADJACENT

PATCH/INFILL EXPOSED &

DAMAGED VCT TILE WITH NEW

MATCH EXISTING

PATCH/INFILL EXPOSED & DAMAGED

VCT TILE WITH NEW

MATCH EXISTING

SEE FIRST FLOOR PLAN DRAWINGS

REMOVE AND

RETAIN EXIST

LIGHT FIXTURE &

COMPONETS

SEE ELEC & RCP

DRAWINGS

TYP

REMOVE AND RETAIN

CEILING TILE TO ACCESS EXIST MECH

SEE MECH & RCP DRAWINGS

TYP

REMOVE AND RETAIN EXISTING

BOARDS AS REQUIRED TO

INSTALL NEW PIPING

RETURN TO OWNER

SEE MECH DRAWINGS

NOT TO SCALE

A1

TYP EXIST CABINET AND MECH FLOOR UNIT

A.

Muse

N

OWNER JOB NO. ----

ISSUED FOR BIDDING08.11.2026

SHEET TITLE

SHEET NO.

A1.1.7

KEY PLAN

N.T.S.

ROOF PLAN -

AREA A

Taylor Schools

Hoover Middle School - HVAC Upgrades

27101 Beverly Rd Taylor, MI 48180

TC JOB NO. 107445

ADDENDUM 00108.31.2026

PROJECT TITLE

ROOF GENERAL NOTES:

1. MAINTAIN ROOF DRAINS IN FUNCTIONING CONDITION

TO ENSURE ROOF DRAINAGE AT END OF EACH

WORKDAY.

2. PREVENT DEBRIS FROM ENTERING OR BLOCKING ROOF

DRAINS AND CONDUCTORS.

3. PATCH ROOF SYSTEM AT ALL REMOVED

PENETRATIONS, CURBS, AND EQUIPMENT. REFER TO

MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.

4. PATCH ROOF SYSTEM AND PROVIDE FLASHING AT ALL

NEW ROOF PENETRATIONS, CURBS, AND EQUIPMENT.

REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL

DRAWINGS.

5. SEE MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS

FOR GENERAL ROOFING NOTES SPECIFIC TO THOSE

TRADES.

6. PROVIDE CRICKETS ON HIGH SIDE OF ROOFTOP UNITS

& OTHER EQUIPMENT, TYPICAL.

7. FINAL LOCATION OF ROOFTOP EQUIPMENT TO BE

COORDINATED WITH STRUCTURAL AND MECHANICAL

WORK.

8. PAINT ALL EXPOSED ROOFTOP NATURAL GAS LINES,

REFER TO SPECIFICATIONS.

9. ALL EQUIPMENT IS TO REMAIN OPERATIONAL DURING

CONSTRUCTION. COORDINATE REMOVAL AND OR

REPLACEMENT OF EQUIPMENT WITH OWNER.

10. ROOF SLOPES INDICATED ON THE DRAWINGS ARE TO

INDICATE DESIGN INTENT ONLY. CONTRACTOR SHALL

PROVIDE SHOP DRAWINGS FOR THE COMPLETE

ROOFING SYSTEM TO ENSURE PROPER DRAINAGE,

INCLUDING TAPERED INSULATION LAYOUT, FLOW

DIRECTIONS, DRAIN LAYOUT, AND CRICKET LOCATIONS.

REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

11. PROVIDE ROOF FLASHING FOR ALL ROOF MOUNTED

EQUIPMENT AND PENETRATIONS AT ALL NEW ROOFING

LOCATIONS. REFER TO PLUMBING, MECHANICAL &

ELECTRICAL DRAWINGS.

ROOF PLAN LEGEND:

EXISTING

MEMBRANE ROOF

SYSTEM

KEYNOTES:

(NOTE: NOT ALL NUMBERS ARE USED)

M-0 EXISTING MECHANICAL UNIT

SEE MECHANICAL DRAWINGS

M-1 NEW MECHANICAL UNIT

PROVIDE CRUB AND FLASHING AS NEEDED

SEE MECHANICAL DRAWINGS

XX-#

A B C D

E F G H J K

ALT

#1

ALT

#1

2' -6

M

IN

2'

-6

M

IN

2'-6"

MIN

2' -6

M

IN

INSTALL

BALLASTED

GUARD

STRUCT NOTE:

EXISTING JOISTS 6' O.C.

MUST HIT JOIST OR

ADD QUICK FRAMES BELOW

SEE SHEET A1.1.9

FOR STRUCT NOTES

STRUCT NOTE:

ADD QUICK FRAMES BELOW

UNIT BTW. EXIST. 32LJ AT +/- 7'-3" O.C.

SEE SHEET A1.1.9 FOR STRUCT NOTES

M-1

M-1

M-1

M-1

ROOF

ACCESS

HATCH

EXHUAST FAN

M-1

EXHUAST FAN

M-1

M-1

M-1

M-1

M-1

M-0

M-0

M-1 M-1

STRUCT NOTE:

EXISTING JOISTS 6' O.C.

MUST HIT JOIST OR

ADD QUICK FRAMES BELOW

SEE SHEET A1.1.9

FOR STRUCT NOTES

EQUIPMENT PLATFORM

SEE MECH DRAWINGS

FOR NOTES

AREA - A

SEE SHEET A1.1.7

AREA - C

SEE SHEET A1.1.9

A R

E A

B

S E

E S

H E

E T

A 1.

1.

A R

E A

C

S E

E S

H E

E T

A 1.

1.

A R

E A

B

S E

E S

H E

E T

A 1.

1.

A R

E A

A

S E

E S

H E

E T

A 1.

1.

ALT

#2

NEW ROOF

PENETRATION

TO GYM FAN

ROOM BELOW

NEW ROOF PENETRATION

TO GYM FAN ROOM BELOW

INSTALL

BALLASTED

GUARD

INSTALL

BALLASTED

GUARD

NEW ROOF

PENETRATION

NEW ROOF

PENETRATION

NEW ROOF

PENETRATION

NEW ROOF

PENETRATION

ROOF

ACCESS

HATCH

EXHUAST FAN

M-0

M-0 M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

ACCU

AHU-1

SEE MECH

R

TU

S

E

M

C

H

RTU - SEE

MECH

SCALE: 1/8" = 1'-0"A2

ROOF PLAN - AREA A

A.

Muse

N

OWNER JOB NO. ----

ISSUED FOR BIDDING08.11.2026

SHEET TITLE

SHEET NO.

A1.1.8

KEY PLAN

N.T.S.

ROOF PLAN -

AREA B

Taylor Schools

Hoover Middle School - HVAC Upgrades

27101 Beverly Rd Taylor, MI 48180

TC JOB NO. 107445

ADDENDUM 00108.31.2026

PROJECT TITLE

ROOF GENERAL NOTES:

1. MAINTAIN ROOF DRAINS IN FUNCTIONING CONDITION

TO ENSURE ROOF DRAINAGE AT END OF EACH

WORKDAY.

2. PREVENT DEBRIS FROM ENTERING OR BLOCKING ROOF

DRAINS AND CONDUCTORS.

3. PATCH ROOF SYSTEM AT ALL REMOVED

PENETRATIONS, CURBS, AND EQUIPMENT. REFER TO

MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.

4. PATCH ROOF SYSTEM AND PROVIDE FLASHING AT ALL

NEW ROOF PENETRATIONS, CURBS, AND EQUIPMENT.

REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL

DRAWINGS.

5. SEE MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS

FOR GENERAL ROOFING NOTES SPECIFIC TO THOSE

TRADES.

6. PROVIDE CRICKETS ON HIGH SIDE OF ROOFTOP UNITS

& OTHER EQUIPMENT, TYPICAL.

7. FINAL LOCATION OF ROOFTOP EQUIPMENT TO BE

COORDINATED WITH STRUCTURAL AND MECHANICAL

WORK.

8. PAINT ALL EXPOSED ROOFTOP NATURAL GAS LINES,

REFER TO SPECIFICATIONS.

9. ALL EQUIPMENT IS TO REMAIN OPERATIONAL DURING

CONSTRUCTION. COORDINATE REMOVAL AND OR

REPLACEMENT OF EQUIPMENT WITH OWNER.

10. ROOF SLOPES INDICATED ON THE DRAWINGS ARE TO

INDICATE DESIGN INTENT ONLY. CONTRACTOR SHALL

PROVIDE SHOP DRAWINGS FOR THE COMPLETE

ROOFING SYSTEM TO ENSURE PROPER DRAINAGE,

INCLUDING TAPERED INSULATION LAYOUT, FLOW

DIRECTIONS, DRAIN LAYOUT, AND CRICKET LOCATIONS.

REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

11. PROVIDE ROOF FLASHING FOR ALL ROOF MOUNTED

EQUIPMENT AND PENETRATIONS AT ALL NEW ROOFING

LOCATIONS. REFER TO PLUMBING, MECHANICAL &

ELECTRICAL DRAWINGS.

ROOF PLAN LEGEND:

EXISTING

MEMBRANE ROOF

SYSTEM

KEYNOTES:

(NOTE: NOT ALL NUMBERS ARE USED)

M-0 EXISTING MECHANICAL UNIT

SEE MECHANICAL DRAWINGS

M-1 NEW MECHANICAL UNIT

PROVIDE CRUB AND FLASHING AS NEEDED

SEE MECHANICAL DRAWINGS

XX-#

ALT

#1

ALT

#1

M-1

M-1

M-1

EXHUAST FAN

EXHUAST FAN

EXHUAST FAN

M-1 M-1 M-1 M-1 M-1 M-1

M-1 M-1

M-1 M-1

M-1 M-1

M-1 M-1

M-1

M-1

M-1

M-1 M-1 M-1

M-1

M-1

EXHUAST FAN

EXHUAST FAN

EXHUAST FAN

M-0

M-0

M-0

ROOF STEP

M-1M-1

STRUCT NOTE:

ADD QUICK FRAMES BELOW

SEE SHEET A1.1.9

FOR STRUCT NOTES

A R

E A

B

S E

E S

H E

E T

A 1.

1.

A R

E A

C

S E

E S

H E

E T

A 1.

1.

NEW ROOF

PENETRATION

NEW ROOF

PENETRATION

NEW ROOF

PENETRATION

NEW ROOF

PENETRATION

M-0

M-0

M-0

M-0

M-0 M-0

M-0

M-0

M-0

M-0

M-0

M-0

M-0

ACCU

AHU-1

SEE MECH

RTU - SEE

MECH

SCALE: 1/8" = 1'-0"A2

ROOF PLAN - AREA B

A.

Muse

N

OWNER JOB NO. ----

ISSUED FOR BIDDING08.11.2026

SHEET TITLE

SHEET NO.

A1.3.2

KEY PLAN

N.T.S.

FIRST FLOOR

REFLECTED

CEILING PLAN -

AREA B

Taylor Schools

Hoover Middle School - HVAC Upgrades

27101 Beverly Rd Taylor, MI 48180

TC JOB NO. 107445

ADDENDUM 00108.31.2026

PROJECT TITLE

9'-0"

GYP-01

CEILING HEIGHT AS MEASURED

TO BOTTOM OF ELEMENT

CEILING TYPE/FINISH

CEILING FIXTURE LEGEND

NOTE: NOT ALL SYMBOLS SHOWN ARE USED ON DRAWINGS.

ELECTRICAL FIXTURES

SPEAKER

RECESSED ROUND INCANDESCENT

RECESSED SQUARE INCANDESCENT

RECESSED SQUARE WITH FLARE

FRAME (MERCURY OR INCANDESCENT)

2' x 4' RECESSED FLUORESCANT

2' x 2' RECESSED FLUORESCANT

1' x 4' SURFACE FLUORESCANT

4' x 4' RECESSED FLUORESCANT

MECHANICAL EQUIPMENT / FIXTURES

RETURN AIR GRILL (TO FIT 24"x24" GRID)

SUPPLY AIR DIFFUSER (TO FIT 24"x24"

GRID)

VENT TO CEILING SPACE (TO FIT

24"x24" GRID)

SUPPLY OR RETURN (IN CENTER OF

TILE)

MECHANICAL UNIT

SEE MECHANICAL DRAWINGS

CEILING MATERIAL LEGEND

GYPSUM BOARD OR SYNTHETIC VENEER

PLASTER CEILING / SOFFIT / BULKHEAD

SUSPENDED ACOUSTICAL PANEL

CEILING

EXPOSED OR EXISTING CONSTRUCTION

TO REMAIN

CEILING GENERAL NOTES

1. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS

FOR ADDITIONAL INFORMATION ON MATERIALS AND

CONSTRUCTION.

2. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS

FOR FIXTURE TYPES AND ADDITIONAL INFORMATION

PERTAINING TO MECHANICAL AND ELECTRICAL WORK.

3. COORDINATE SIZE AND LOCATION OF ALL ACCESS

PANELS WITH TRADE REQUIRING THE SAME. ACCESS

PANELS ARE SPECIFIED ARCHITECTURALLY BUT ARE

REQUIRED TO BE PROVIDED BY TRADE. INDICATE ALL

LOCATIONS WITHIN FIXED GYPSUM BOARD CEILINGS

BEFORE INSTALLATION OF GYPSUM BOARD AND

RECEIVE WRITTEN APPROVAL FROM ARCHITECT

BEFORE PROCEDING WITH INSTALLATION.

4. COORDINATE INSTALLATION OF CEILING SUSPENSION

SYSTEMS WITH OTHER CEILING SPACE EQUIPMENT

SUPPORTS.

5. ALL SMOKE BARRIER PARTITIONS, HORIZONTAL EXIT

ENCLOSURES AND FIRE RATED PARTITIONS THAT

EXTEND TO DECK ABOVE SHALL BE MARKED EVERY

20'-0" HORIZONTALLY WITHIN THE CEILING SPACE: "FIRE

AND SMOKE BARRIER - PROTECT ALL OPENINGS."

6. ALL GYPSUM BOARD FASCIAS AT SOFFITS ADJACENT TO

ACOUSTICAL PANEL CEILINGS SHALL EXTEND 6"MINMUM

ABOVE ACOUSTICAL PANEL CEILINGS.

7. PROVIDE WOOD BLOCKING ABOVE GYPSUM BOARD

CEILINGS AS REQUIRED FOR MISCELLANEOUS

SUSPENDED ITEMS, INCLUDING CURTAIN TRACKS,

WINDOW SHADES, ACOUSTICAL BAFFLES, ETC.

8. CENTER ALL SPRINKLER HEADS IN CEILING PANELS

UNLESS SHOWN OTHERWISE.

9. CONTRACTOR TO PAINT ALL NON-FINISH ELEMENTS IN

AREAS NOTED AS EXP-PT TO INCLUDE, BUT NOT LIMITED

TO, STRUCTURE (BEAMS, JOISTS, STRUTURAL DECK,

ETC), FP/PLUMB LINES (PIPING, HANGERS, ETC),

MECHANICAL DUCTWORK AND PIPING (HANGERS,

STRAPPING, UNISTRUT, ETC), ELECTRICAL (CONDUITS,

HANGERS, BACKBOXES, ETC), AND TECHNOLOGY

(CONDUITS, HANGERS, BACKBOXES, ETC). COORDINATE

WITH ARCHITECT FOR QUESTIONS RELATED TO

ELEMENTS TO BE PAINTED.

CEILING LEGEND

ACOUSTICAL PANEL CEILINGS (APC):

APC1 REINSTALL SALVAGED ACOUSTICAL PANEL

CEILING TILES

TYP IN "HATCHED AREAS"

APC2 NEW CEILING ACOUSTICAL PANEL

CEILING TILES

MATCH EXISTING ADJACENT TILES

TYP IN "HATCHED AREAS"

GYPSUM BOARD CEILINGS (GYP) - SEE FINISH PLANS FOR

PAINT COLORS OR OTHER FINISHES:

GYP-PTX PAINTED GYP-01 (UNO) CEILING ON

SUSPENDED CEILING GRID SYSTEM OR

NSMF-X

L: LIGHT FIXTURE

L-1: REINSTALL EXISTING LIGHT FIXTURE

AND ELECTRICAL COMPONENTS

TYP (LIGHT FIXTURES ADJACENT TO HVAC

UNITS)

CEILING LEGEND

REFER TO THE FOLLOWING TAG FOR CEILING TYPE &

BOTTOM ELEVATION INFORMATION FOR EACH ROOM OR

ELEMENT UNLESS OTHERWISE NOTED.

MECH

UNIT

CL RM

VEST

LOBBY

CORR

J.C.

22 GIRLS

BOYS

CONF

CONS

WAIT

CONSUL

CONF

BOOK

HALL

CLINIC

TLT

TLT

GEN OFFICE

VAULT

TLT

WAIT

GEN OFFICE

PRIN

CL RM

WORK

HALL

AUDIO VIS.

TEACHERS

MEN

CL ROOM

MEDIA CENTER

CL RM

CORR

CORR

J.C.

BOYS

GIRLS

CL RM

CL RM

OFFICE

OFFICE

105A

VEST

VEST

CORR

CORR

ST

TLT

TLT

112A

WORK

110-A

TYPING

CL RM

CL RM

CL RM

CL RM

CORR

OFF

CL RM

CL RM

CL RM

CL RM

PREP

CL RM

OFF

CORR

PREP

CL RM

CL RM

CL RM

WET RM

CL RM

150B

CL RM

VEST

CORR

VEST

APC1

APC1

APC1

APC2

APC2

APC2 APC2

APC2

APC2

APC2

APC2

APC1APC1

APC1

APC1

CL RM

L-1

APC1

L-1

APC2

APC1

APC1

APC1

APC1

APC1 APC1

APC1APC1APC1

APC1

APC1

APC1

L-1 L-1 L-1 L-1 L-1

L-1 L-1

L-1L-1L-1

APC1

APC1

APC1

APC1

APC1

ALT

#1

ALT

#1

STOR

CONS

CONF

OFF

WOMEN

MEN

SPEC. ED

CL RM

OFF

APC1

APC1

APC2

APC2

APC2

APC2

APC2

APC2

L-1 L-1 L-1L-1 L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1L-1

L-1

L-1 L-1

APC1

L-1 L-1

L-1

L-1

L-1

L-1 L-1

L-1

L-1

L-1

L-1

APC2

NEW ROOF

PENETRATION

SEE MECH

NEW ROOF

PENETRATION

SEE MECH

APC1

L-1 L-1

L-1L-1

APC1 APC1

L-1

L-1

L-1

L-1

L-1

L-1L-1

L-1 L-1

L-1

L-1

L-1

APC1

APC1

APC1 APC1

APC1

APC1 APC1

APC1

APC1APC1

APC1

APC1

APC1

APC2

A R

E A

B

S E

E S

H E

E T

A 1.

3.

A R

E A

C

S E

E S

H E

E T

A 1.

3.

MECH

UNIT

MECH

UNIT

MECH

UNIT

MECH

UNIT

M E

C H

U N

IT

M E

C H

U N

IT

MECH

UNIT

MECH

UNIT

M E

C H

U N

IT

M E

C H

U N

IT

M E

C H

U N

IT

M

E C

H U

N

IT

M E

C H

U N

IT

M

E C

H U

N

IT

MECH

UNIT

SCALE: 1/8" = 1'-0"A2

FIRST FLOOR REFLECTED CEILING PLAN - AREA B

UN

IT

C

UN

IT

B

T T

T T

T

(E)HUV

FLOOR

MOUNTED

(E)HUV

FLOOR

MOUNTED (E)HUV

(E)HUV

FLOOR

MOUNTED (E)HUV

(E)HUV

(E)HUV

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

(E)HUV

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)HUV

CEILING

MOUNTED

(E)CONV

(E)CONV

(E)CUH

CEILING

MOUNTED

(E)AC

(E)AC(E)HUV

CEILING

MOUNTED

(E)CUH

WALL

MOUNTED

(E)CUH

WALL

MOUNTED

T

T

T

(E)CONV

(E)CUH

(E)CUH

WALL

MOUNTED

(E)CUH

CEILING

MOUNTED

(E)12x12

EA UP

(E)RG

(E)SD

(E)RG(E)RG

(E)G

(E)SD(E)SD

(E)SD

(E)SD

(E)RG

(E)SD

(E)RG

(E)SD

(E)SD

(E)RG

(E)SD

(E)EG

(E)EG

(E)RG

(E)SD

(E)SD

(E)RG

(E)RG

(E)EG

(E)EG

(E)EG

(E)SD

(E)EG

(E)SG(E)SD

(E)SD (E)SD(E)RG (E)RG

(E)SD (E)SD(E)RG (E)RG

(E)SD (E)SD (E)RG

(E)SD (E)SD (E)RG

(E)SD (E)SD (E)RG

(E)SD (E)SD(E)RG (E)RG

(E)RG

(E)RG

(E)RG

(E)SD (E)SD(E)RG (E)RG

(E)SD (E)RG

(E)RG

(E)SD

(E)RG

(E)SD

(E)SD

(E)SD

(E)RG(E)RG

(E)SG (E)RG

(E)SG

(E)RG

(E)SG

(E)RG

(E)EG (E)EG (E)EG

(E)EG

(E)EG

(E)EG

(E)CONV

(E)3"

(E)4"

(E)EA UP

TO EF

(E)60x27 LOUVER

(E)60x27 LOUVER (E)60x27 LOUVER

(E)60x27 LOUVER (E)60x27 LOUVER

BLANKED OFF**

(E)60x27 LOUVER

(E)60x27 LOUVER

(E)60x27 LOUVER

(E)60x27 LOUVER

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)24x24

UP TO IH

4 4

(E)EG

(E)EG

(E)EG

(E)EG

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E )H

HW

R

(E )H

HW

S

(E )H

HW

S

(E )H

HW

R

(E )H

HW

R

(E )H

HW

S

(E )H

HW

R

(E )H

HW

S

(E )H

HW

R

(E )H

HW

S

(E )H

HW

R

(E )H

HW

S

(E)EG(E)EG(E)EG

(E)RG

(E)RG (E)RG

(E)RG

(E)RG(E)RG

(E)RG (E)RG

(E)RG

(E)RG (E)RG

(E)RG

(E)RG(E)RG(E)RG(E)RG(E)RG

(E)RG

(E)RG

(E)EG

(E)SD

(E)SD

T T T T T T T

T

T

T

T

T

T

T

T

T

T

T T

T

T

T

T

T

T

T

T

(E)12x10 EA

UP TO EF

(E)68x16 RA

ALTERNATE-1

ALTERNATE-1

(E)15x15 EA

UP TO EF

(E)GAS VALVE BOX

(E)GAS VALVE BOX

(E)GAS

VALVE BOX

J.C.

GIRLS

BOYS

CONS

CONS

CONF

WAIT

CONSUL

CONF

BOOK

CLINIC

TLT

TLT

TLT

9AULT

WAIT

GEN. OFFICE

PRIN

LOBBY

9EST

OFFICE

105A

OFFICE

CL ROOM

GIRLS

BOYS

J.C.

MEN

WOMEN

MEN

TEACHERS

AUDIO 9IS.

WORK

OFF

HALL

CONF.

CL ROOM

MEDIA CENTER

CL RM

CORR.

9EST

TYPING

109 SPEC. ED

WORK

110-A

ST

TLT

TLT

112A CORR

PREP

OFF

CORR

119 OFF

CORR

CL RM

CL RM

CL RM

CL RM

CL RM

CL RM

CL RM

CL RM

CORR

CORR

9EST

WET RM

PREP

OFF

9EST

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)EA UP TO

EF ON ROOF

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)CASEWORK

21" DEPTH

FROM WALL

(E)60x10

LOUVER

HIGH

WALL

(E)GAS VALVE BOX

ANGLED CEILING

BUILD-OUT FOR

EXISTING HUV

ANGLED CEILING

BUILD-OUT FOR

EXISTING HUV

(E)60x10 LOUVER

HIGH WALL

(E)60x10 LOUVER

HIGH WALL

(E)EG

OUTLINE FOR

CEILING BUILD-OUT

FOR EXISTING HUV

~9" DROP FLAT

(E)OA DUCT UP TO

INTAKE HOOD ON ROOF

(E)60x10 LOUVER

HIGH WALL

(E)60x10 LOUVER HIGH WALL(E)60x10 LOUVER

HIGH WALL

TO (E)HC-3

IN MEZZ

(E)G (E)G (E)1"(E)1"

6 6 6

(E)3"

(E)4"

(E )H

HW

S

(E )H

HW

R

2-1/2" HHWS/R

UP TO MECH

MEZZANINE

CL RM

CL RM

CL RM

CL RM

CL RM

146 CL RM

147 CL RM

150A

CL RM

CL RM

ALTERNATE-1

GENERAL DEMOLITION NOTES

A

THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL

EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF

DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.

B

ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL

BE PERFORMED AT A TIME APPROVED IN ADVANCE BY OWNER'S

REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT

BUILDING'S OPERATION.

C

PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE

SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,

SYSTEMS, AND UTILITIES. NOTIFY DESIGN PROFESSIONAL OF ANY

INTERFERENCES OR DISCREPANCIES.

D

ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED

COMPLETELY WITH ALL RELATED ITEMS INCLUDING HANGERS,

SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN-ENDED PIPES

AND DUCTS.

E

THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT

BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING

RELOCATED AND OWNER-PROVIDED EQUIPMENT.

F

VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING

UTILITIES IN THE FIELD, INCLUDING POINTS OF CONNECTION, PRIOR TO

STARTING WORK.

G

ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING

UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN

LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND

REQUIRES FIELD VERIFICATION.

H

ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.

WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING

DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS

REQUIRED TO MATCH EXISTING.

DEMOLITION KEYED NOTES

REMOVE AIR CONDITIONING MINI SPLIT AND ALL ACCESSORIES

COMPLETE INCLUDING ALL SUPPORTS, CONTROLS AND REFRIGERANT

PIPING. CAP ALL PIPE PENETRATIONS THRU ROOF OR EXTERIOR WALL

AND SEAL WEATHER TIGHT. ASSOCIATED CONDENSING UNIT TO BE

DISCONNECTED AND REMOVED FROM EITHER ROOF OR SIDEWALL, SEE

ROOF PLAN FOR ADDITIONAL INFORMATION. PRIOR TO DEMO, VERIFY

WITH OWNER IF EXISTING UNITS SHOULD BE SALVAGED.

DISCONNECT AND REMOVE EXISTING FAN COIL UNIT ABOVE THE CEILING

INCLUDING ALL HANGERS, SUPPORTS, ACCESSORIES, AND CONTROLS.

REMOVE ALL ASSOCIATED DUCTWORK AND DIFFUSERS AS INDICATED.

REMOVE AND CAP ALL ASSOCIATED PIPING AS REQUIRED FOR

INSTALLATION OF NEW UNIT ABOVE THE CEILING, AS INDICATED.

COORDINATE WITH ALL TRADES FOR ADDITIONAL INFORMATION ON

DEMOLITION SCOPE FOR FAN COIL UNITS INDICATED.

DISCONNECT AND REMOVE AIR HANDLING UNIT COMPLETE INCLUDING

ALL ACCESSORIES, SUPPORTS, HANGERS, AND CONTROLS. DISCONNECT

AND TEMPORARILY CAP HEATING HOT WATER PIPING AND PREPARE TO

REWORK FOR NEW CONNECTION. REMOVE DUCTWORK AS INDICATED

AND PREPARE EXISTING DUCTWORK FOR NEW CONNECTIONS.

DISCONNECT AND REMOVE UNIT VENTILATOR COMPLETE INCLUDING ALL

ACCESSORIES, SUPPORTS AND HANGERS, AND CONTROLS. REMOVE ALL

EXISTING REFRIGERANT PIPING UP THRU ROOF, CAP AND SEAL EXISTING

ROOF PENETRATION WEATHER TIGHT. REMOVE AND CAP ALL

ASSOCIATED PIPING AS REQUIRED FOR INSTALLATION OF NEW UNIT

ABOVE THE CEILING, AS INDICATED. DISCONNECT AND REMOVE

EXISTING DUCTWORK FROM EITHER EXISTING INTAKE HOOD THRU ROOF

OR EXISTING INTAKE LOUVER THRU EXTERIOR WALL, AS INDICATED.

PREPARE EXISTING INTAKE HOOD OR INTAKE LOUVER FOR NEW

CONNECTIONS. COORDINATE WITH ALL TRADES FOR ADDITIONAL

INFORMATION ON DEMOLITION SCOPE FOR UNIT VENTILATORS

INDICATED.

REMOVE CABINET UNIT HEATER COMPLETE INCLUDING ALL

ACCESSORIES AND CONTROLS. HEATING HOT WATER PIPING TO REMAIN.

TEMPORARILY CAP AND PREPARE TO REWORK FOR NEW CONNECTION.

CUT AND CAP EXISTING GAS PIPING ABOVE CEILING IN CORRIDOR CLOSE

TO MAIN. ENSURE GAS PIPING IS UPSTREAM OF THE ASSOCIATED GAS

VALVE BOX LOCATED IN THE CLASSROOM PRIOR TO DEMOLITION.

REMOVE EXHAUST GRILLE AND EXHAUST DUCTWORK AS INDICATED

BACK THRU ROOF AND REMOVE EXISTING EXHAUST FAN (ON ROOF).

PREPARE ROOF OPENING FOR NEW DUCTWORK AND NEW EXHAUST FAN.

SEE DEMOLITION ROOF PLANS FOR ADDITIONAL INFORMATION.

DISCONNECT AND REMOVE INLINE EXHAUST FAN FOR LOCKER ROOMS

INCLUDING ALL ASSOCIATED HANGERS, SUPPORTS, CONTROLS AND

DUCTWORK, AS INDICATED. REMOVE EXISTING LOUVER AND SEAL

EXTERIOR WALL PENETRATION WEATHER TIGHT. PREPARE EXISTING

DUCTWORK FOR NEW CONNECTIONS.

9 DUCT OR PIPING CONTINUATION INTO MEZZANINE. SEE SHEET MD4.20

AND M4.20 FOR CONTINUATION AND ADDITIONAL INFORMATION.

REMOVE DUCTWORK AS INDICATED. PREPARE EXISTING DUCTWORK FOR

NEW CONNECTION. SEE NEW WORK PLANS FOR ADDITIONAL

INFORMATION.

REMOVE EXISTING EXHAUST DUCTWORK UP THRU ROOF AND EXISTING

EXHAUST FAN (ON ROOF). CAP EXISTING ROOF PENETRATION. SEE ROOF

PLAN FOR ADDITIONAL INFORMATION.

12 REMOVE EXISTING SHOWER HEADS IN SPACE AS INDICATED. CUT AND

CAP ALL PIPING AT FLOOR.

REMOVE RELIEF DUCTWORK THRU ROOF AND RELIEF HOOD ON ROOF.

CAP AND SEAL ROOF PENETRATION WEATHER TIGHT. SEE DEMOLITION

ROOF PLAN FOR ADDITIONAL INFORMATION.

X

SCALE:

MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

1/8" = 1'-0"

UNIFIED BUILDING

SYSTEMS ENGINEERING

SHEET TITLE

SHEET NO.

PROJECT TITLE

UBS PROJECT : 047.26.03

69 S. GRATIOT AVE.

MT. CLEMENS, MI 48043

N

KEY PLAN

N.T.S.

A B

C

OWNER JOB NO.

TC JOB NO. 107445

TD\ORU SFKRROV

HRRYHU MLGGOH

SFKRRO - H9AC

USJUDGHV

27101 BHYHUO\ RG

TD\ORU� MI 48180

ISSUED FOR BIDDING08.11.2026

MECHANICAL

DEMOLITION FIRST

FLOOR PLAN - UNIT B

MD1.11

ADDENDUM 00108.31.2026

jalvord Highlight

(E)HV-5

(E)HHWS DN

(E)HHWR DN TO

CONV BELOW

(E)34x18 SA

INTO GYM

SEE LOWER LEVEL FOR

CONTINUATION

(E)34x18 SA

INTO GYM

SEE LOWER LEVEL

FOR

CONTINUATION

(E)OA INTAKE

LOUVER

OPEN TO BELOW

GYM FAN

ROOM

(E)24x36 RA DN

SEE LOWER LEVEL

FOR CONTINUATION

(E)24x36 RA OED

PLENUM RETURN TO

EXISTING UNIT

REMOVE ELBOW,

PREPARE DUCT THRU

FLOOR FOR NEW

CONNECTION.

(E)HHWR

(E)HHWS

(E)1"

(E)2"

SEE LOWER LEVEL

FOR CONTINUATION

OF PIPING

GENERAL DEMOLITION NOTES

A

THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL

EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF

DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.

B

ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL

BE PERFORMED AT A TIME APPROVED IN ADVANCE BY OWNER'S

REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT

BUILDING'S OPERATION.

C

PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE

SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,

SYSTEMS, AND UTILITIES. NOTIFY DESIGN PROFESSIONAL OF ANY

INTERFERENCES OR DISCREPANCIES.

D

ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED

COMPLETELY WITH ALL RELATED ITEMS INCLUDING HANGERS,

SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN-ENDED PIPES

AND DUCTS.

E

THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT

BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING

RELOCATED AND OWNER-PROVIDED EQUIPMENT.

F

VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING

UTILITIES IN THE FIELD, INCLUDING POINTS OF CONNECTION, PRIOR TO

STARTING WORK.

G

ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING

UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN

LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND

REQUIRES FIELD VERIFICATION.

H

ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.

WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING

DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS

REQUIRED TO MATCH EXISTING.

DEMOLITION KEYED NOTES

DISCONNECT AND REMOVE AIR HANDLING UNIT COMPLETE INCLUDING

ALL SUPPORTS, HANGERS, ACCESSORIES, AND CONTROLS. REMOVE

DUCTWORK AND PIPING INDICATED AND PREPARE EXISTING DUCTWORK

AND PIPING FOR NEW CONNECTIONS.

REMOVE DUCTWORK, DUCT SLEEVE, AND LOUVER (WHERE APPLICABLE)

THROUGH WALL. COORDINATE WITH ARCHITECTURAL TRADES TO PATCH

WALL PENETRATION AS NECESSARY.

(E)12x12

EA DN

(E)12x12

EA UP

(E)32x20 SA INTO PLENUM(E)18x16 SA

INTO PLENUM

SEE LOWER LEVEL

FOR CONTINUATION

(E)26x20 SA

INTO PLENUM

SEE LOWER LEVEL FOR

CONTINUATION

(E)RA TO PLENUM

(E)HV-1

(E)12x12

EA DN

(E)12x10 EA

INTO PLENUM

SEE LOWER LEVEL

FOR CONTINUATION

(E)HC-3

(E)HC-2

(E)HHWS DN

(E)HHWR DN

SEE LOWER LEVEL

FOR CONTINUATION

(E)RA TO PLENUM

MAIN FAN

ROOM

OPEN TO BELOW

(E)HHWR

(E)HHWS

(E)2-1/2"

(E)1-1/2"(E)1"

(E)HV-3

(E)HV-4

(E)26x10

SA DN

(E)26x10

SA DN

BALCONY

MECH

STOR

(E)HHWR

(E)HHWS

SEE LOWER LEVEL

FOR CONTINUATION

OF PIPING

(E)2-1/2"

(E)1-1/2"

UNIFIED BUILDING

SYSTEMS ENGINEERING

SHEET TITLE

SHEET NO.

PROJECT TITLE

UBS PROJECT : 047.26.03

69 S. GRATIOT AVE.

MT. CLEMENS, MI 48043

N

KEY PLAN

N.T.S.

A B

C

OWNER JOB NO.

TC JOB NO. 107445

TD\ORU SFKRROV

HRRYHU MLGGOH

SFKRRO - H9AC

USJUDGHV

27101 BHYHUO\ RG

TD\ORU� MI 48180

ISSUED FOR BIDDING08.11.2026

ENLARGED

MECHANICAL

DEMOLITON PLANS -

BALCONY

MD4.20

SCALE:

ALTERNATE-2:

ENLARGED MECHANICAL DEMOLITON - BALCONY - GYM FAN ROOM

1/4" = 1'-0" SCALE:

ALTERNATE-1:

ENLARGED MECHANICAL DEMOLITON - BALCONY - MAIN FAN ROOM

1/4" = 1'-0"

SCALE:

ALTERNATE-2:

ENLARGED MECHANICAL DEMOLITON - BALCONY - MECH ROOM 65

1/4" = 1'-0"

M1.00

M1.00

M1.00

08.31.2026 ADDENDUM 001

HO HUB OUTLET

GAL GALLON

FFE FINISHED FLOOR ELEVATION

CIRC CIRCULATING

T & P TEMPERATURE AND PRESSURE

SP STATIC PRESSURE

SQUARE FOOT/SQUARE FEET

SERVICE SINK

SHOWER

SS

SqFt / SF

SH

POUNDS PER SQUARE INCH - GAUGEPSIG

REVOLUTIONS PER MINUTE

REDUCED PRESSURE ZONE

SUPPLY AIR

ROOF SUMP

RELIEF AIR

RETURN AIR

RPM

SA

RS

RPZ

REL.A

RA

POUNDS PER SQUARE INCH - ABSOLUTE

PRESSURE REDUCING VALVE

PRESSURE DROP (FEET OF WATER)

OPPOSED BLADE DAMPER

OPEN ENDED DUCT

OUTSIDE DIAMETER

ON CENTER / CENTER TO CENTER

OUTSIDE AIR

PD

PSIA

PRV

OBD

OED

OD

OC

OA

MANUAL AIR VENT

NOT IN CONTRACT

NORMALLY CLOSED

NOMINAL

NORMALLY OPEN

NOISE CRITERIA

MINIMUM

MISCELLANEOUS

MANHOLE

MANUFACTURER

MECHANICAL

NOM

NIC

N.C.

NO

NC

MAV

MIN

MISC

MFR

MECH

MH

1000 BRITISH THERMAL UNITS PER HOUR

POUNDS PER HOUR

LOCKED ROTOR AMPS

LEAVING WET BULB TEMPERATURE

LEAVING DRY BULB TEMPERATURE

MAXIMUM

LAVATORY

LEAVING AIR TEMPERATURE

INTERNAL STATIC PRESSURE

KILOWATT

INDIRECT WASTE

INCHES

INVERT

LRA

MAX

MBH

LWB

LDB

LBS/HR

LAV

ISP

INV

KW

LAT

IW

IN

WALL HYDRANT

WATER GAUGE

VENT THRU ROOF

WATER CLOSET

WET BULB TEMPERATURE

WASTE AND VENT

WG

WH

W

WC

WB

W&V

VTR

WASTE

HOUR

INVERT ELEVATION

HERTZ

INSIDE DIAMETER

HYDRANT

HORSEPOWER

HEATING

HYD

HZ

IE

ID

HTG

HR

HP

VOLUME DAMPER (MANUALLY ADJUSTABLE)

UNDERWRITERS LABORATORY

UNLESS NOTED OTHERWISE

TEMPERATURE CONTROL

TOTAL STATIC PRESSURE

UNDERGROUND

VD

UNO

UR

UL

URINAL

TSP

TYP

UG

TC

TYPICAL

SMOKE DETECTOR

MOTORIZED DAMPER

VOLUME DAMPER (MANUALLY ADJUSTABLE)

CO2 SENSOR

CROSS SECTION OF SUPPLY AIR DUCT

FLEXIBLE CONNECTION

LINEAR SLOT DIFFUSER

SUPPLY DIFFUSER

RETURN OR EXHAUST GRILLE

TRANSFER GRILLE

FLEXIBLE DUCT CONNECTION TO SUPPLY

CONCENTRIC TRANSITION (DOUBLE LINE)

CONCENTRIC TRANSITION (SINGLE LINE)

ECCENTRIC TRANSITION (SINGLE LINE)

ECCENTRIC TRANSITION (DOUBLE LINE)

RADIUS RECTANGULAR ELBOW

RADIUS ROUND ELBOW

ROUND ELBOW UP

RECTANGULAR ELBOW UP

RECTANGULAR ELBOW DOWN

ROUND ELBOW DOWN

RECTANGULAR TAKE-OFF (SINGLE LINE)

RECTANGULAR TAKE-OFF (DOUBLE LINE)

ROUND TAKE-OFF (SINGLE LINE)

ROUND TAKE-OFF (DOUBLE LINE)

SPIN-IN FITTING (WITH VOLUME DAMPER)

ELBOW (WITH TURNING VANES)

FULL LOAD AMPSFLA

GALLONS PER HOUR

GALLONS PER MINUTE

FLOOR

FEET

FEET PER MINUTE

FUNNEL FLOOR DRAIN

FLOOR SINK

FACE VELOCITY

FIRE VALVE CABINET

GPM

GPH

FVC

FV

FT

FS

FFD

FPM

FLR

FLEXIBLE CONNECTION

FIRE HOSE VALVE

FLOOR DRAIN

FACE AREA (COIL) / FREE AREA (LOUVER)

DEGREES FAHRENHEIT

FD

FHV

FC

FA

°F

ELECTRIC WATER COOLER

EXTERNAL STATIC PRESSURE

ELEVATION

ENTERING AIR TEMPERATURE

EXHAUST AIR

EXPANSION JOINT

EXHAUST FAN

ENERGY MANAGEMENT SYSTEM

ELECTRICALELECT

EWC

EWB

ESP

EMS

EJ

EL

EF

EAT

EDB

EA/EXH

DEGREES

DRY BULB TEMPERATURE

DOWN

EXISTING

DOMESTIC WATER HEATER

DRAIN TILE CONNECTION

DIRECT DIGITAL CONTROL

CABINET UNIT HEATER

CONTROL VALVE

CONVECTOR

DWH

(E)

DTC

DDC

DN

CV

DB

DEG

CUH

CONV

COOLING

CONTINUATION OR CONTINUED

CLEAN OUT

CAPACITY

BRITISH THERMAL UNIT

CUBIC FEET PER HOUR

CONSTANT AIR VOLUME

BACKWATER VALVE

CUBIC FEET PER MINUTE

CO

CONT

CLG

CFM

CFH

CAV

CAP

BWV

BTUH

BTU

ACCESS DOOR

AIR EXTRACTOR

BRAKE HORSEPOWER

BOTTOM OF DUCT

BACKFLOW PREVENTER

AUTOMATIC SPRINKLER RISER

ABOVE FINISHED FLOOR

AIR PRESSURE DROP

AUTOMATIC AIR VENT / AIR ADMITTANCE VALVE

ASR

BOD

BHP

BFP

APD

AFF

AAV

AE

AD

ENTERING WET BULB TEMPERATURE

ENTERING DRY BULB TEMPERATURE

BRITISH THERMAL UNITS PER HOUR

DESCRIPTION

MECHANICAL ABBREVIATIONS

ABBREV. DESCRIPTIONABBREV.

MECHANICAL ABBREVIATIONSMECHANICAL ABBREVIATIONS

ABBREV. DESCRIPTION

MECHANICAL SYMBOLS

ABBREV. DESCRIPTION

R

R

D

D

SD

INCLINED DROP IN DIRECTION OF AIR FLOW

(SINGLE LINE)

INCLINED DROP IN DIRECTION OF AIR FLOW

(DOUBLE LINE)

INCLINED RISE IN DIRECTION OF AIR FLOW

(SINGLE LINE)

INCLINED RISE IN DIRECTION OF AIR FLOW

(DOUBLE LINE)

DIFFUSER

DUCT

CROSS SECTION OF EXHAUST OR RETURN AIR

ORS OVERFLOW ROOF SUMP

RELATIVE HUMIDITYRH

OS&Y OUTSIDE SCREW AND YOKE

REQD REQUIRED

EXISTING DEVICES OR EQUIPMENT

NEW OR MODIFIED DEVICES OR EQUIPMENT

EXISTING SYSTEM COMPONENT TO BE REMOVED

DRAWING NOTATION

POINT OF NEW CONNECTION

SYMBOL

NEW WORK KEY NOTE NO. 1

DEMOLITION KEY NOTE NO. 1

EQUIPMENT TAG

DESCRIPTION

NEW

EXISTING

SMOKE DAMPER

FIRE DAMPER (HORIZONTAL)

FIRE DAMPER (VERTICAL)

NEW

EXISTING

EXISTING

NEW

EXISTING

NEW

EXISTING

NEW

HB HOSE BIBB

PT PRESSURE / TEMPERATURE PORT

FIRE HYDRANT

FIRE HOSE CABINET

FIRE HOSE RACK

FIRE DEPARTMENT CONNECTION

FHR

FHC

FDC

FH

AIR TERMINAL TAG:

IE: DIFFUSER TYPE = S-1

NECK SIZE = 12x12

CFM = 150 (TYPICAL FOR 2)

COMBINATION FIRE/SMOKE DAMPER

(HORIZONTAL)

COMBINATION FIRE/SMOKE DAMPER

(VERTICAL)

ECCENTRIC REDUCER

DESCRIPTION

MECHANICAL PIPING SYMBOLS

ABBREV.

PIPE ELBOW DOWN

DIRECTION OF FLOW

PIPE ELBOW UP

UNION

CONCENTRIC REDUCER

FLEXIBLE CONNECTION

PIPE GUIDE

PIPE ANCHOR

EXPANSION JOINT

CIRCULATING PUMP

BUTTERFLY VALVE

GLOBE VALVE

ANGLE VALVE

BALL VALVE

ISOLATION VALVE

PIPE CAP OR PLUG

TRAP (PLAN VIEW)

CENTRIFUGAL FAN

CHECK VALVE (SPRING)

PLUG VALVE

NEEDLE VALVE

FLOOR DRAIN / FUNNEL FLOOR DRAIN (ELEVATION)

CLEAN OUT (IN FLOOR)

ROOF SUMP

FLOOR DRAIN / FUNNEL FLOOR DRAIN (PLAN VIEW)

AUTOMATIC GAS SHUT-OFF VALVE

CHECK VALVE (SWING)

BACKFLOW PREVENTER

DIRECTION OF PIPE PITCH

HOSE BIBB, WALL HYDRANT

SPRINKLER HEAD (SIDEWALL)

SIAMESE CONNECTION (YARD)

FIRE HYDRANT

FLOW SWITCH

SPRINKLER HEAD (UPRIGHT)

SIAMESE CONNECTION (WALL MOUNTED)

OUTSIDE SCREW AND YOKE VALVE (OS&Y)

CLEAN OUT (IN LINE)

FLOW MEASURING DEVICE

COMBINATION FLOW MEASURING AND BALANCING DEVICE

BALANCING VALVE

AUTOMATIC AIR VALVEAAV

MANUAL AIR VALVEMAV

S = SUPPLY

R = RETURN

E = EXHAUST

T = TRANSFER

MINIMUM CIRCUIT AMPACITY MCA

MAXIMUM OVER-CURRENT PROTECTIONMOP

UNIT HEATERUH

PIPE TEE DOWN

STRAINER

CO

CO

WCO CLEAN OUT (WALL)

S

BFP

M WATER METER ASSEMBLY

PRESSURE REGULATING VALVE

SOLENOID VALVE

CONTROL VALVE (2-WAY / 3-WAY)

H

T

CO2

RETURN OR EXHAUST / SUPPLY AIR FLOW

M

MOTOR OPERATED DAMPER (AUTOMATIC)MOD

PUMPED SANITARY PIPING

HEATING HOT WATER SUPPLY PIPING

HEATING HOT WATER RETURN PIPING

SANITARY WASTE PIPING

CHILLED WATER SUPPLY PIPING

CHILLED WATER RETURN PIPING

FUEL OIL SUPPLY PIPING

DESCRIPTION

PIPING LEGEND

ABBREV.

DOMESTIC HOT WATER PIPING

DOMESTIC COLD WATER PIPING

PUMPED STEAM CONDENSATE RETURN PIPING

CONDENSATE DRAIN PIPING

STORM SEWER PIPING

STEAM PIPING

VENT PIPING

FUEL OIL RETURN PIPING

DRAIN TILE

REFRIGERANT LIQUID PIPING

REFRIGERANT SUCTION PIPING

FIRE PROTECTION PIPING

RAIN CONDUCTOR PIPING

GEO HEAT EXCHANGE RETURN

GEO HEAT EXCHANGE SUPPLY

CW

HW

HWR DOMESTIC HOT WATER RETURN PIPING

BOOSTED-DOMESTIC HOT WATER PIPINGBHW

BOOSTED-DOMESTIC COLD WATER PIPINGBCW

DOMESTIC 140°F HOT WATER PIPINGHW(140°F)

FOR

FOS

CHWR

CHWS

CD

CONDENSER WATER SUPPLY PIPING

CONDENSER WATER RETURN PIPINGCWR

CWS

NATURAL GAS PIPINGG

GXHR

GXHS

STEAM CONDENSATE RETURN PIPINGCR

HHWR

HHWS

HEAT PUMP LOOP SUPPLY PIPING

HEAT PUMP LOOP RETURN PIPINGHPLR

HPLS

NON POTABLE COLD WATER PIPINGNPCW

DT

F

PCR

LOW PRESSURE CONDENSATE PIPINGLPC

HIGH PRESSURE CONDENSATE PIPINGHPC

NITROGEN GAS PIPINGN

PSAN

RC

ORC OVERFLOW RAIN CONDUCTOR PIPING

RL

RS

SAN

ST

STM

HIGH PRESSURE STEAM PIPINGHPS

LOW PRESSURE STEAM PIPINGLPS

V

COMPRESSED AIR PIPINGCA

VACUUM PIPINGVAC

OXYGEN GAS PIPINGO2

MEDICAL AIR PIPINGMA

PUMPED STORM PIPINGPST

HOT GAS BY-PASS PIPINGHGB

TEMPERED WATER PIPINGTW

THERMOSTAT OR

TEMPERATURE SENSOR

HUMIDISTAT OR

HUMIDITY SENSOR

S-1 12x12 150-2

FURNISHEDFURN

INSTALLEDINST

AHU-1

FS

S

YEAR CODE

MICHIGAN BUILDING CODE

MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS

MICHIGAN PLUMBING CODE

MICHIGAN MECHANICAL CODE

INTERNATIONAL FUEL GAS CODE

APPLICABLE CODES

AND REGULATIONS

MICHIGAN UNIFORM ENERGY CODE2019

NFPA 101 WITH BFS AMENDMENTS2012

UNIFIED BUILDING

SYSTEMS ENGINEERING

SHEET TITLE

SHEET NO.

PROJECT TITLE

UBS PROJECT : 047.26.03

69 S. GRATIOT AVE.

MT. CLEMENS, MI 48043

OWNER JOB NO.

TC JOB NO. 107445

TD\ORU SFKRROV

HRRYHU MLGGOH

SFKRRO - H9AC

USJUDGHV

27101 BHYHUO\ RG

TD\ORU� MI 48180

ISSUED FOR BIDDING08.11.2026

MECHANICAL

GENERAL

INFORMATION

M0.00

DRAWING INDEX

SHT. NO. DESCRIPTION

M0.00 MECHANICAL GENERAL INFORMATION

M1.00 COMPOSITE MECHANICAL FIRST FLOOR PLAN

MD1.10 MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT A

MD1.11 MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

MD1.12 MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT C

MD1.30 MECHANICAL DEMOLITION ROOF PLAN - UNIT A

MD1.31 MECHANICAL DEMOLITION ROOF PLAN - UNIT B

MD1.32 MECHANICAL DEMOLITION ROOF PLAN - UNIT C

MD4.20 ENLARGED MECHANICAL DEMOLITON PLANS - BALCONY

M1.10 MECHANICAL NEW WORK FIRST FLOOR PLAN - UNIT A

M1.11 MECHANICAL NEW WORK FIRST FLOOR PLAN - UNIT B

M1.12 MECHANICAL NEW WORK FIRST FLOOR PLAN - UNIT C

M1.30 MECHANICAL NEW WORK ROOF PLAN - UNIT A

M1.31 MECHANICAL NEW WORK ROOF PLAN - UNIT B

M1.32 MECHANICAL NEW WORK ROOF PLAN - UNIT C

M4.20 ENLARGED MECHANICAL NEW WORK PLANS - BALCONY

M5.00 MECHANICAL DETAILS

M5.01 MECHANICAL DETAILS

M6.00 MECHANICAL SCHEDULES

M6.01 MECHANICAL SCHEDULES

M8.00 MECHANICAL TEMPERATURE CONTROLS

M8.01 MECHANICAL TEMPERATURE CONTROLS

08.31.2026 ADDENDUM 001

jalvord Highlight

UN

IT

C

UN

IT

B

T

(E)CONV

(E)CONV

(E)CONV

(E)12x12

EA UP

(E)RG

(E)SD

(E)RG(E)RG

(E)G

(E)SD(E)SD

(E)SD

(E)SD

(E)RG

(E)SD

(E)RG

(E)SD

(E)SD

(E)RG

(E)SD

(E)EG

(E)EG

(E)RG

(E)SD

(E)SD

(E)RG

(E)RG

(E)EG

(E)EG

(E)EG

(E)SD

(E)EG

(E)SG(E)SD

(E)SD (E)SD(E)RG (E)RG

(E)SD (E)SD(E)RG (E)RG

(E)SD (E)SD (E)RG

(E)SD (E)SD (E)RG

(E)SD (E)SD (E)RG

(E)SD (E)SD(E)RG (E)RG

(E)RG

(E)RG

(E)RG

(E)SD (E)SD(E)RG (E)RG

(E)SD (E)RG

(E)RG

(E)SD

(E)RG

(E)SD

(E)SD

(E)SD

(E)RG(E)RG

(E)SG (E)RG

(E)SG

(E)RG

(E)SG

(E)RG

(E)EG (E)EG (E)EG

(E)EG

(E)EG

(E)EG

(E)CONV

(E)3"

(E)4"

(E)EA UP

TO EF

(E)60x27 LOUVER

(E)60x27 LOUVER (E)60x27 LOUVER

(E)60x27 LOUVER (E)60x27 LOUVER

BLANKED OFF**

(E)60x27 LOUVER

(E)60x27 LOUVER

(E)60x27 LOUVER

(E)60x27 LOUVER

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)24x24

UP TO IH

(E)EG

(E)EG

(E)EG

(E)EG

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E)HHWS

(E)HHWR

(E )H

HW

R

(E )H

HW

S

(E )H

HW

S

(E )H

HW

R

(E )H

HW

R

(E )H

HW

S

(E )H

HW

R

(E )H

HW

S

(E )H

HW

R

(E )H

HW

S

(E )H

HW

R

(E )H

HW

S

(E)EG(E)EG(E)EG

(E)RG

(E)RG (E)RG

(E)RG

(E)RG(E)RG

(E)RG (E)RG

(E)RG

(E)RG (E)RG

(E)RG

(E)RG(E)RG(E)RG(E)RG(E)RG

(E)RG

(E)RG

(E)EG

T

T

T

(E)12x10 EA

UP TO EF

(E)68x16 RA

(E)15x15 EA

UP TO EF

(E)GAS VALVE BOX

(E)GAS VALVE BOX

(E)GAS

VALVE BOX

(E)EA UP TO

EF ON ROOF

(E)60x10

LOUVER

HIGH

WALL

(E)GAS VALVE BOX

ANGLED CEILING

BUILD-OUT FOR

EXISTING HUV

ANGLED CEILING

BUILD-OUT FOR

EXISTING HUV

(E)60x10 LOUVER

HIGH WALL

(E)60x10 LOUVER

HIGH WALL

(E)EG

OUTLINE FOR

CEILING BUILD-OUT

FOR EXISTING HUV

~9" DROP FLAT

(E)OA DUCT UP TO

INTAKE HOOD ON ROOF

(E)60x10 LOUVER

HIGH WALL

(E)60x10 LOUVER HIGH WALL(E)60x10 LOUVER

HIGH WALL

(E)G (E)G (E)1"(E)1"

(E)3"

(E)4"

(E )H

HW

S

(E )H

HW

R

2-1/2" HHWS/R

UP TO MECH

MEZZANINE

HUV-4 HUV-4

HUV-1

HUV-1

HUV-3

HUV-3 HUV-3

HUV-5

HUV-5HUV-5

HUV-4

HUV-4

HUV-3 HUV-1

HUV-5

3 3

3 3

HUV-1

HUV-1 HUV-1

HUV-1 HUV-1

HUV-1

HUV-3

HUV-4

CUH-3

CUH-3

CUH-3

CUH-2

CUH-3

T

T

T

T

T T T T T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

24x16 RA7

30x24 RA UP

TO RTU-2

ALTERNATE-1

34x30 SA UP

TO RTU-2

SA DUCT

OFFSET

J.C.

GIRLS

BOYS

CONS

CONS

18 CONF

WAIT

16 CONSUL

CONF

BOOK

CLINIC

TLT

TLT

TLT

9AULT

WAIT

GEN. OFFICE

PRIN

LOBBY

9EST

OFFICE

105A

OFFICE

CL RM

GIRLS

BOYS

J.C.

MEN

WOMEN

MEN

TEACHERS

AUDIO 9IS.

WORK

OFF

HALL

CONF.

CL RM

MEDIA CENTER

CL RM

CORR.

9EST

TYPING

SPEC. ED

WORK

110-A

ST

TLT

TLT

112A CORR

PREP

OFF

CORR

119 OFF

CORR

CL RM

CL RM

CL RM

116 CL RM

CL RM

CL RM

CL RM

CL RM

CORR

CORR

9EST

WET RM

PREP

OFF

9EST

CUH-3

RLRS

RLRS

RLRS

RL RSRLRS

RL

RS

RL

RS

RL

RS

RL

RS

RL RS

RLRS

RL

RSRL

RS

RL

RS

RL

RS

RL

RS

RL

RS

RL

RS

RL

RS

RL

RS

RL

RS

RL

RS

RLRS

RLRS

RLRS

RL

RS

24x36 RELIEF

OPENING THRU

ROOF TO GRH-1

24x36 RELIEF

OPENING THRU

ROOF TO GRH-1

20x16 TA 20x16 TA

ABOVE

CEILING

20x16 TA

ABOVE

CEILING

20x16 TA

ABOVE

CEILING

20x16 TA

ABOVE

CEILING

20x16 TA

ABOVE

CEILING

1/2" 3/4"

1/2" 3/4"

(350 CFM)

(500 CFM)

TYP. OF 6

IN MEDIA CENTER

(250 CFM)

TYP. OF 2

(200 CFM)(100 CFM)

(200 CFM)

(100 CFM)

(200 CFM)

8ALTERNATE-1

M M M M M

M M MM

M

M

M M

M

M

(350 CFM)

(350 CFM)

(350 CFM)

(350 CFM)

(350 CFM)

(350 CFM)

(350 CFM)

8 (350 CFM)

(350 CFM)

(100 CFM)

(100 CFM)

(200 CFM)

(200 CFM)

(500 CFM)

(200 CFM)

(200 CFM)

(200 CFM)

(100 CFM)

8(300 CFM)

CL RM

CL RM

CL RM

CL RM

CL RM

CL RM

CL RM

150A CL RM

CL RM

HVAC GENERAL NOTES

A

THESE DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE GENERAL

EXTENT OF THE WORK TO BE PERFORMED. PROVIDE AND EXECUTE ALL

HVAC SYSTEMS PER ENGINEER'S SPECIFICATION, AND LOCAL APPLICABLE

CODES INCLUDING AMENDMENTS, BULLETINS, ETC. AS WELL AS THE

STANDARDS OF INSTALLATION AND EQUIPMENT ESTABLISHED FOR THE

BUILDINGS, AND REQUIREMENTS OF THE OWNER.

B

EXCEPT FOR CHANGES AS MAY BE SPECIFICALLY APPROVED BY THE

ENGINEER OF RECORD. IN ACCORDANCE WITH ALTERNATES OF OPTIONS

AS STATED HEREINAFTER, ALL WORK MUST BE IN FULL ACCORDANCE

WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. SYSTEMS ARE

TO BE COMPLETE, EFFICIENT, AND SATISFACTORY OPERATION WHEN

PROJECT IS DELIVERED TO THE OWNER.

C

THE CONTRACTOR AND EACH SUBCONTRACTOR COVENANTS AND

AGREES TO INDEMNIFY, DEFEND, AND HOLD HARMLESS THE

CONSULTING ENGINEER, ARCHITECT, AND OWNER FROM AND AGAINST

ANY LIABILITY, LOSS, DAMAGE, OR EXPENSE INCLUDING ATTORNEYS

ARISING FROM A FAILURE OR ALLEGED FAILURE ON THE PART OF THE

CONTRACTOR, SUBCONTRACTORS, AND THEIR AGENTS/EMPLOYEES

PROPERLY TO DISCHARGE THE OBLIGATIONS ASSUMED BY HIM/HER IN

THE PERFORMANCE OF THE WORK, INCLUDING ANY ACT OR OMISSION

ALLEGEDLY RESULTING IN DEATH, PERSONAL INJURY, PROPERTY

DAMAGE, OR IMPROPER CONSTRUCTION PROTOCOL.

D

CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVAL

FROM GOVERNING AUTHORITIES AND FILE NECESSARY FORMS, PAY ALL

INSPECTION FEES.

E

CONTRACTOR TO EXAMINE ALL ADJOINING WORK BEFORE

COMMENCEMENT OF HIS/HER SCOPE OF WORK. REPORT ANY

DISCREPANCIES TO THE CONSTRUCTION MANAGER FOR REVIEW AND

APPROVAL. COORDINATE ALL WORK WITH OTHER TRADES TO ENSURE

THAT INSTALLATION IS MADE IN ACCORDANCE WITH THE CONTRACT

DOCUMENTS.

F

PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT,

DUCTWORK/PIPING SHALL NOT INTERFERE WITH ELECTRICAL

EQUIPMENT CLEARANCE.

G

CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH

MANUFACTURER'S CERTIFIED DRAWINGS. ALL PIPING CONNECTIONS

SHALL BE MINIMUM 3/4" UNLESS NOTED OTHERWISE.

H FURNISH ADEQUATE LIABILITY INSURANCE AND BONDING DOCUMENTS

AS REQUIRED BY THE OWNER.

J

SUPPORT ALL ANCHORS SECURED TO THE BOTTOM OF FLOOR SLABS

SHALL BE DROP-IN OR SLEEVE ANCHOR TYPE. ALL SUPPORTING STEEL

SHALL BE PROVIDED BY THE CONTRACTOR.

K DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT

RESTRICTS THE ACCESS TO MECHANICAL DEVICES REQUIRING ACCESS.

L THE CONTRACTOR SHALL PROVIDE ALL MISCELLANNEOUS SUPPORTING

STEEL FOR THE PROPER INSTALLATION OF MECHANICAL SYSTEMS.

M

BRANCH DUCTWORK TO GRILLES, REGISTERS, AND DIFFUSERS SHALL BE

THE SAME SIZE AS THE TERMINAL DEVICE NECK SIZE WHERE NO DUCT

SIZE IS INDICATED.

NEW WORK KEYED NOTES

INSTALL CEILING MOUNTED HORIZONTAL UNIT VENTILATOR COMPLETE

INCLUDING SUPPORTS, HANGERS, CONTROLS AND ACCESSORIES. EXTEND AND

CONNECT 1" HEATING HOT WATER SUPPLY AND RETURN PIPING TO NEW UNIT.

PROVIDE NEW ISOLATION AND CONTROL VALVES. EXTEND NEW

REFRIGERATION PIPING FROM ASSOCIATED CONDENSING UNIT ON ROOF TO

NEW UNIT. LINESETS TO BE SIZED PER MANUFACTURER'S REQUIREMENTS.

ROUTE OUTSIDE AIR DUCT TO EXISTING INTAKE HOOD ON ROOF. ROUTE

CONDENSATE PIPING THRU SIDEWALL TO EXTERIOR OR PROVIDE CONDENSATE

PUMP AND ROUTE UP THRU MECHANICAL PIPE CURB (WHICHEVER IS NEAREST).

TERMINATE ALL PENETRATIONS WEATHER TIGHT. REPLACE THERMOSTAT IN

PLACE OF EXISTING AND REUSE THERMOSTAT BOX IF APPLICABLE.

INSTALL CEILING MOUNTED HORIZONTAL UNIT VENTILATOR COMPLETE

INCLUDING SUPPORTS, HANGERS, CONTROLS AND ACCESSORIES.

EXTEND AND CONNECT 1" HEATING HOT WATER SUPPLY AND RETURN

PIPING TO NEW UNIT. PROVIDE NEW ISOLATION AND CONTROL VALVES.

EXTEND NEW REFRIGERATION PIPING FROM ASSOCIATED CONDENSING

UNIT ON ROOF TO NEW UNIT. LINESETS TO BE SIZED PER

MANUFACTURER'S REQUIREMENTS. ROUTE OUTSIDE AIR DUCT UP THRU

ROOF TO NEW INTAKE HOOD ON ROOF. ROUTE CONDENSATE PIPING

THRU SIDEWALL TO EXTERIOR OR PROVIDE CONDENSATE PUMP AND

ROUTE UP THRU MECHANICAL PIPE CURB (WHICHEVER IS NEAREST).

TERMINATE ALL PENETRATIONS WEATHER TIGHT. REPLACE

THERMOSTAT IN PLACE OF EXISTING AND REUSE THERMOSTAT BOX IF

APPLICABLE.

INSTALL CEILING MOUNTED HORIZONTAL UNIT VENTILATOR COMPLETE

INCLUDING SUPPORTS, HANGERS, CONTROLS AND ACCESSORIES. EXTEND AND

CONNECT 1" HEATING HOT WATER SUPPLY AND RETURN PIPING TO NEW UNIT.

PROVIDE NEW ISOLATION AND CONTROL VALVES. EXTEND NEW

REFRIGERATION PIPING FROM ASSOCIATED CONDENSING UNIT ON ROOF TO

NEW UNIT. LINESETS TO BE SIZED PER MANUFACTURER'S REQUIREMENTS.

ROUTE OUTSIDE AIR DUCT TO EXISTING INTAKE LOUVER THROUGH EXTERIOR

WALL. ROUTE CONDENSATE PIPING TO EXTERIOR THRU EXISTING LOUVER.

TERMINATE ALL PENETRATIONS WEATHER TIGHT. REPLACE THERMOSTAT IN

PLACE OF EXISTING AND REUSE THERMOSTAT BOX IF APPLICABLE.

INSTALL FLOOR MOUNTED HORIZONTAL UNIT VENTILATOR COMPLETE.

EXTEND AND CONNECT 1" HEATING HOT WATER SUPPLY AND RETURN TO

NEW UNIT. PROVIDE NEW ISOLATION AND CONTROL VALVES. REUSE

EXISTING OUTDOOR AIR LOUVER. ROUTE CONDENSATE PIPING THRU

EXISTING LOUVER. EXTEND NEW REFRIGERATION PIPING FROM

ASSOCIATED CONDENSING UNIT ON ROOF TO NEW UNIT. LINESETS TO

BE SIZED PER MANUFACTURER'S REQUIREMENTS. ROUTE NEW

REFRIGERANT AND HYDRONIC PIPING DOWN IN PRE-FABRICATED METAL

ENCLOSURE. COORDINATE WITH ARCHTIECTURAL TRADES TO MATCH

FINISHES TO EXISTING WALL. REPLACE THERMOSTAT IN PLACE OF

EXISTING AND REUSE THERMOSTAT BOX IF APPLICABLE.

INSTALL CABINET UNIT HEATER COMPLETE IN PLACE OF EXISTING.

REWORK HEATING HOT WATER PIPING AND EXTEND 1/2" HEATING HOT

WATER SUPPLY AND 1/2" HEATING HOT WATER RETURN PIPING TO

CABINET UNIT HEATER AND TERMINATE WITH ISOLATION VALVES. IF

CABINET UNIT HEATER IS RECESSED REWORK WALL PENETRATION TO

ALIGN WITH DIMENSIONS OF NEW UNIT. FIELD VERIFY ALL DIMENSIONS

BEFORE COMMENCEMENT OF WORK. REPLACE THERMOSTAT IN PLACE OF

EXISTING AND REUSE THERMOSTAT BOX IF APPLICABLE.

INSTALL CEILING MOUNTED HORIZONTAL FAN COIL UNIT (FCU) COMPLETE

IN PLACE OF EXISTING AIR HANDLING UNIT. REWORK SUPPLY DUCTWORK

AND OUTSIDE AIR DUCTWORK TO CONNECT TO HORIZONTAL UNIT

VENTILATOR. REWORK EXISTING HEATING HOT WATER PIPING AND EXTEND

1" HEATING HOT WATER SUPPLY AND 1" HEATING HOT WATER RETURN TO

FCU AND TERMINATE WITH ISOLATION VALVES. REPLACE THERMOSTAT IN

PLACE OF EXISTING AND REUSE THERMOSTAT BOX IF APPLICABLE.

7 24x16 RETURN AIR DUCT PENETRATION INTO MECHANICAL MEZZANINE

ROOM, SEE SHEET M4.20 FOR CONTINUATION.

8 CLEAN EXISTING DIFFUSER AND GRILLE. REBALANCE TO CFM INDICATED.

REFRIGERANT LIQUID AND SUCTION (RL/RS) PIPING UP THRU ROOF

THRU COMMON MECHANICAL PIPE CURB. SEE ROOF PLAN AND DETAILS

FOR ADDITIONAL INFORMATION.

X

SCALE:

MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

1/8" = 1'-0"

UNIFIED BUILDING

SYSTEMS ENGINEERING

SHEET TITLE

SHEET NO.

PROJECT TITLE

UBS PROJECT : 047.26.03

69 S. GRATIOT AVE.

MT. CLEMENS, MI 48043

N

KEY PLAN

N.T.S.

A B

C

OWNER JOB NO.

TC JOB NO. 107445

TD\ORU SFKRROV

HRRYHU MLGGOH

SFKRRO - H9AC

USJUDGHV

27101 BHYHUO\ RG

TD\ORU� MI 48180

ISSUED FOR BIDDING08.11.2026

MECHANICAL NEW

WORK FIRST FLOOR

PLAN - UNIT B

M1.11

08.31.2026 ADDENDUM 001

A B C D

E F G H J K

UNIT A

UNIT C

UN

IT

C

UN

IT

B

UN

IT

A

UN

IT

B

RTU-1

(HC-1 REPLACE.)

42x42 SA DN 54x24 RA DN

THRU ROOF

IH-1 IH-1

IH-1 IH-1

(E)IH

(E)KITCHEN EF

(E)KITHCEN EF

(E)EF (E)EF

(E)EF

(E)EF

(E)GRH

(E)GRH

(E)BF

(E)BF

(E)BF

(E)EF

(E)BF

(E)ROOF

ACCESS HATCH

(E)IH(E)IH

EF-5

EF-6

ACCU-2

ACCU-3

EF-1

6…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .