This file is a set of construction plans and specifications for the Butlertown Road Improvement Project in the Town of Montville, Connecticut. The project encompasses approximately 2.0 miles of roadway reconstruction along Butlertown Road from station 0+00 to station 20+00, with a proposal deadline of April 15, 2026, at 10:00 AM EDT. The scope of work includes full-depth reclamation of existing pavement to a minimum depth of 12 inches, placement of new bituminous concrete surfacing (2.5 inches of Class 2 surface course and 2.5 inches of Class 1 binder course), installation of drainage infrastructure including a 12-inch corrugated HDPE pipe system and water quality treatment structures (Contech Cascade Model CS-4 separators), vegetated swales, and Cape Cod berms for erosion control. Additional work includes tree removal within the limits of grading subject to approval by the town tree warden for trees exceeding 8 inches in diameter, clearing and grubbing for proposed swale areas, removal of existing structures and stumps, mailbox reset if required, metal beam guardrail installation (53 feet of Type R-B 350), pavement markings, and loam and seed restoration of all disturbed areas. The construction documents provide detailed plan and profile sheets with elevation data, cross-sections, and construction details across seven sheets.
The solicitation does not specify line-item pricing, estimated project value, or budget allocation in the available materials. Delivery terms are specified as Free On Board Destination, with payment terms to be negotiated with the selected vendor. No set-aside designations, disadvantaged enterprise requirements, or bidder eligibility restrictions are identified, allowing all qualified vendors to submit proposals. No incumbent contractor, current infrastructure integration requirements, or formal site visit or bidders' conference dates are documented. Additional information regarding funding sources, project budget, award timeline, and vendor question-and-answer procedures should be obtained by contacting Patrick Wall, the town representative, at 860-848-6717 or pwall@montville-ct.org.
Text of this file
Sheet List Table Sheet
Number Sheet Title
-- Cover Sheet
1 General Notes
2 Plan & Profile 1
3 Plan & Profile 2
4 Plan & Profile 3
5 Plan & Profile 4
6 Construction Details (1)
7 Construction Details (2)
· TREE REMOVAL WITHIN THE CONTRACT LIMITS SHALL BE DETERMINED IN CONJUNCTION WITH THE ENGINEER AND TOWN TREE WARDEN.
· NO TREE IN EXCESS OF 8" SHALL BE REMOVED WITHOUT APPROVAL BY THE TREE WARDEN.
· THE CONTRACTOR SHALL STAKE THE LIMITS OF GRADING PRIOR TO DETERMINING EXTENT OF TREE REMOVAL.
· ALL TREES (REGARDLESS OF SIZE), WITHIN THE LIMITS OF GRADING, OR INTERFERING WITH THE PROPOSED WORK SHALL BE REMOVED
BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
· THE CONTRACTOR SHALL GIVE ABUTTING PROPERTY OWNERS THE OPPORTUNITY TO TAKE CUT WOOD FOR THEIR PRIVATE USE. IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE ALL REMAINING STUMPS, CUT-UP TREES & LIMBS, ETC. WITHIN THE
CONTRACT LIMITS.
· ALL COSTS ASSOCIATED WITH THE ABOVE WORK SHALL BE INCLUDED IN THE SPECIFIC TREE REMOVAL PAY ITEMS.
· THE CONTRACTOR SHALL PROTECT REMAINING TREES FROM DAMAGE DURING CONSTRUCTION.
NAVD 88
BASE ELEV
210.00
BUTLERTOWN ROAD CL (STA 0+00 TO STA 5+00)
HORIZ. SCALE = 1" = 20'
VERT. SCALE= 1" = 5'
0+00
7.
.2
6.
.5
1+00
6.
.8
8.
.9
2+00
9.
.0
0.
.9
3+00
0.
.7
0.
.1
4+00
1.
.6
1.
.0
5+00
2.
.3
0.91%
-1.65% 2.43%
G R
AD
E
BR
EA
K
ST
A
0+
.0
EL
EV
.2
7 GRADE BREAK STA = 4+50.00
ELEV = 231.90
PVI STA = 0+70.76
PVI ELEV = 226.10
A.D. = 4.08% K = 24.54
100' VC
PV
C
: 0 +2
0.
EL
EV
: 2
.9
PV
T:
+2
0.
EL
EV
: 2
.3
LOW POINT ELEV = 226.60
LOW POINT STA = 0+61.25
100' VC
PV
C
: 1 +7
EL
EV
: 2
.6
PV
T:
+7
EL
EV
: 2
.3
PROPOSED GRADE
CROWNED ROADWAY SECTION
19' - 12" CORRUGATED HDPE PIPE
S=4.2%
0.91%
-1.65% 2.43%
EXISTING 42"
REINFORCED CONCRETE PIPE
CONTECH CASCADE MODEL CS-4
WITH GRATED INLET
TF=226.3±
INV IN=(12" NE)=222.00
INV OUT=(8" NW)=222.00
10' - 8" PVC PIPE
S=33.1%
SF SF SF SF SF
SF SF
.0
S 32° 04' 54" E 700.00' 0+00 1+00 2+00 3+00 4+00 5+0022
8 230
231 232
229 232
CONTECH CASCADE MODEL CS-4
WITH GRATED INLET
TF=226.3±
INV IN=(12" NE)=222.00
INV OUT=(8" NW)=222.00
CB W' CAPE COD BERM TOP
(3-FOOT SUMP)
TF=226.4±
INV OUT=(12" SW)=223.00
19' - 12" CORRUGATED HDPE PIPE
S=4.2%
CORE DRILL AND PROVIDE
WATER TIGHT CONNECTION
TO EXISTING PIPE
8" PVC
INV. ELEV. =218.00
10' - 8" PVC PIPE
S=33.1%
M A
TC
H
LI
N
E (S
EE
S
H
EE
T
BIT. CONC.
D'WAY
BIT. CONC.
D'WAY
BIT. CONC.
D'WAY APRON
BIT. CONC.
D'WAY APRON
CAPE COD BERM
(TYP.)
LIMIT OF GRADING
(TYP.)
RETAIN AND PROTECT
GUARDRAIL
GRAVEL D'WAY GRAVEL D'WAY
4" EPOXY RESIN
DOUBLE YELLOW LINE
(TYP.)
INSERT INLET
SEDIMENTATION
CONTROL DEVICE
INSTALL AND MAINTAIN
SILT FENCE. (TYP.)
REMOVE TREES WITHIN
LIMIT OF GRADING
(TYP.)
R-B APPROACH TERMINAL SECTION
CTDOT HW-910_17
R-B END ANCHORAGE TYPE II
PER CTDOT HW-911_01
LOAM & SEED ALL
DISTURBED AREAS
(TYP.)
COLD RECLAIM
EXISTING PAVEMENT
(SEE DETAIL)
REMOVE AND RESET
MAILBOX IF REQUIRED
PROVIDE 53 FT ±. TYPE R-B 350 METAL BEAM GUIDERAIL.
USE MULTIPLE BLOCKOUTS TO AVOID OBSTRUCTIONS
PER CTDOT HW-910_02 IF REQUIRED
220.00
BUTLERTOWN ROAD CL (STA 5+00 TO STA 10+00)
HORIZ. SCALE = 1" = 20'
VERT. SCALE= 1" = 5'
5+00
2.
.3
2.
.5
6+00
2.
.6
2.
.5
7+00
3.
.6
3.
.9
8+00
3.
.2
3.
.5
9+00
4.
.8
4.
.7
10+00
5.
.2
0.50%
50' VC
PV
C
: 8 +7
EL
EV
: 2
.0
PV
T:
+2
EL
EV
: 2
.5
50' VC
PVC: 9+25
ELEV: 234.57
PVT: 9+75
ELEV: 235.16
PROPOSED GRADE
CROWNED ROADWAY SECTION
.0
'5+00 6+00 7+00 8+00 9+00 10+00
PI 7+00.0
S 31° 28' 33" E 749.99'
M A
TC
H
LI
N
E (S
EE
S
H
EE
T
M A
TC
H
LI
N
E (S
EE
S
H
EE
T
BIT. CONC.
D'WAY APRON
4" EPOXY RESIN
DOUBLE YELLOW LINE
(TYP.)
LIMIT OF GRADING
(TYP.)
VEGETATED SWALE
(SEE DETAIL)
VEGETATED SWALE
(SEE DETAIL)
LOAM & SEED ALL
DISTURBED AREAS
(TYP.)
CLEAR AND GRUB AND REMOVE
ALL TREES IN AREA OF PROPOSED
VEGETATED SWALE
CLEAR AND GRUB AND REMOVE
ALL TREES IN AREA OF PROPOSED
VEGETATED SWALE
REMOVE TREES WITHIN
LIMIT OF GRADING
(TYP.)
COLD RECLAIM
EXISTING PAVEMENT
(SEE DETAIL)
230.00
BUTLERTOWN ROAD CL (STA 10+00 TO STA 15+00)
HORIZ. SCALE = 1" = 20'
VERT. SCALE= 1" = 5'
10+00
5.
.2
5.
.3
11+00
5.
.5
6.
.8
12+00
7.
.1
0.
.4
13+00
3.
.7
6.
.4
14+00
9.
.8
9.
.4
15+00
9.
.1
7.40%
0.63%
PVI STA = 12+07.30
PVI ELEV = 236.61
A.D. = 6.77% K = 22.14
150' VC
PV
C
: 1 1+
.3
EL
EV
: 2
.1
PV
T:
2+
.3
EL
EV
: 2
.1
PVI STA = 13+88.00
PVI ELEV = 249.98
A.D. = -7.80% K = 16.03
125' VC
PV
C
: 1 3+
.5
EL
EV
: 2
.3
PV
T:
4+
.5
EL
EV
: 2
.7
3201' SSD
HIGH POINT ELEV = 249.75
HIGH POINT STA = 14+44.12
PROPOSED GRADE
CROSS SLOPE TRANSITIONCROWNED ROADWAY SECTION SUPERELEVATED ROADWAY SECTION
.0
'10+00 11+00 12+00 13+00 14+00 15+00PI 14+50.023
M A
TC
H
LI
N
E (S
EE
S
H
EE
T
M A
TC
H
LI
N
E (S
EE
S
H
EE
T ) 53
4" EPOXY RESIN
DOUBLE YELLOW LINE
(TYP.)
CAPE COD BERM
(TYP.)
LIMIT OF GRADING
(TYP.)
VEGETATED SWALE
(SEE DETAIL)
REMOVE
BOULDER
BIT. CONC.
D'WAY APRON
BIT. CONC.
D'WAY APRON BIT. CONC.
D'WAY APRON
BIT. CONC.
D'WAY APRON
BIT. CONC.
D'WAY APRON
LOAM & SEED ALL
DISTURBED AREAS
(TYP.)
CLEAR AND GRUB AND REMOVE
ALL TREES IN AREA OF PROPOSED
VEGETATED SWALE
CLEAR AND GRUB AND REMOVE
ALL TREES IN AREA OF PROPOSED
VEGETATED SWALE
REMOVE TREES WITHIN
LIMIT OF GRADING
(TYP.)
COLD RECLAIM
EXISTING PAVEMENT
230.00
BUTLERTOWN ROAD CL (STA 15+00 TO STA 20+00)
HORIZ. SCALE = 1" = 20'
VERT. SCALE= 1" = 5'
15+00
9.
.1
9.
.8
16+00
9.
.5
8.
.4
17+00
8.
.5
8.
.6
18+00
9.
.7
9.
.9
19+00
9.
.1
9.
.1
20+00
9.
.4
-0.40% 0.19%
GRADE BREAK STA = 16+75.00
ELEV = 248.84
GRADE BREAK STA = 20+00.00
ELEV = 249.45
PROPOSED GRADE
SUPERELEVATED ROADWAY SECTION
.0
'15+00 16+00 17+00 18+00 19+00 20+00249
M A
TC
H
LI
N
E (S
EE
S
H
EE
T )4
REMOVE STUMP
REMOVE STUMP
4" EPOXY RESIN
DOUBLE YELLOW LINE
(TYP.)
CAPE COD BERM
(TYP.)
LIMIT OF GRADING
(TYP.)
BIT. CONC.
D'WAY APRON BIT. CONC.
D'WAY APRON
GRAVEL D'WAY
LOAM & SEED ALL
DISTURBED AREAS
(TYP.)
REMOVE TREES WITHIN
LIMIT OF GRADING
(TYP.)
COLD RECLAIM
EXISTING PAVEMENT
REMOVE TREE
NB TRAVEL LANE
BL
CONSTRUCTION
TYPICAL SECTION
BUTLERTOWN ROAD
STA 0+50 TO STA 20+00
(FULL-DEPTH RECLAMATION)
SCALE: 1" = 2'
11'-0')
PGL & CROWN LINE
EXISTING SUB-GRADE
2 12 " BITUMINOUS CONCRETE
CLASS 2 SURFACE COURSE 2 12 " BITUMINOUS CONCRETE
CLASS 1 BINDER COURSE
SB TRAVEL LANE
11'-0"
2.0%
VARIES - 2% MAX.
(SEE PLAN FOR GRADES)
COLD RECLAIM EXISTING PAVEMENT TO A
MINIMUM DEPTH OF 12". RECLAIMED MATERIAL
SHALL MEET THE REQUIREMENTS OF ARTICLE
M.05.01 OF DOT 819 SPECIFICATION.
REGRADE & COMPACT REMAINING MATERIAL.
NOTE:
CAPE COD BERM TO BE SET ON
BINDER OR TO BE LAID AS A
SINGLE MONOLITHIC UNIT WITH
THE TOP COURSE OF PAVEMENT.
BITUMINOUS CONCRETE BERM
HMA S0.375 WHERE DIRECTED
PAVEMENT CONSTRUCTION
PER TYPICAL SECTION
RECLAIMED BASE MATERIAL GRADATION
Square Mesh Sieve Size % Passing by Mass 2½ inches (63 mm) 100 2 inches (50 mm) 95 - 100 ¾ inch (19 mm) 50 - 75 ¼ inch (6.3 mm) 25 - 45 #40 (425 µm) 5 - 20 #100 (150 µm) 2 - 12
(4 '-0
SOLIDS STORAGE SUMP
INLET PIPE
(MULTIPLE INLET PIPES
MAY BE ACCOMMODATED)
OUTLET PIPE
VA
R
IE
S
2' -3
6]
PLAN VIEW B-B
NOT TO SCALE
ELEVATION A-A
NOT TO SCALE
FIBERGLASS OR
POLYPROPYLENE INTERNAL
COMPONENTS
CONTRACTOR TO GROUT
TO FINISHED GRADE
GRADE
RINGS/RISERS
48" [1219] I.D. MANHOLE
STRUCTURE
TOP SLAB ACCESS
(SEE FRAME AND GRATE DETAIL)
TOP OF CENTER CHAMBER
(EXTENSIONS AVAILABLE
AS REQUIRED)
INLET PIPE(S)
LOCATION MAY
VARY WITHIN 260°
PERMANENT
POOL ELEVATION
24" X 24" FRAME AND GRATE
(MAY VARY)
NOT TO SCALE
INLET TRAY
NOT TO SCALE
INLET TRAY
GENERAL NOTES
1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE.
2. FOR SITE SPECIFIC DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT CONTECH
ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com
3. CASCADE SEPARATOR WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION
CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT.
4. CASCADE SEPARATOR STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 2', AND
GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM
ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306.
5. CASCADE SEPARATOR STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C478 AND AASHTO LOAD
FACTOR DESIGN METHOD.
6. ALTERNATE UNITS ARE SHOWN IN MILLIMETERS [mm ].
INSTALLATION NOTES
A. ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS AND
SHALL BE SPECIFIED BY ENGINEER OF RECORD.
B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE CASCADE
SEPARATOR MANHOLE STRUCTURE.
C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE.
D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET AND OUTLET PIPE(S). MATCH PIPE INVERTS WITH ELEVATIONS
SHOWN. ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES.
E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO ASSURE UNIT IS WATER TIGHT, HOLDING WATER TO FLOWLINE
INVERT MINIMUM. ALL JOINTS BELOW PIPE INVERTS SHALL BE GROUTED.
TYPE C TOP TO BE REPLACED WITH CAPE COD BERM TOP
(SEE DETAIL BELOW)
SPECIAL NOTE:
ENSURE OPENINGS CAST IN CONTECH UNIT TAKE ACCOUNT
OF PROPOSED ENTERING AND LEAVING PIPE SLOPES.
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .