- 15 -
SECTION 2: GETTING STARTED
4. Connecting Electrical Power
4. Connecting Electrical Power All Epilog laser systems have an auto-switching power supply that detects the incoming voltage and automatically switches itself to operate properly at any single phase voltage between 100 and 240 VAC. The power supply will also automatically compensate for either 50 or 60 Hz. Epilog supplies the appropriate power cord for the system you ordered. The power cord is found in the accessory package with your machine. The power cord for the laser plugs into the power receptacle located on the left side of the machine in the rear corner. It is recommended that a dedicated 15 amp circuit be used if available, but it is not required.
The Fusion 120 watt laser system requires 208/220/240 volt electrical power. This system will not operate on 120 volt power. The Fusion 120 watt power cord comes with a male plug type NEMA L6-15R (which is a Hubble HBL4570C equivalent).
While the 60 and 75 watt Fusion models can operate on 110 volts, we recommended using 208/220/240 volt electrical power to achieve maximum performance. If you would like a 220V cord for your 60 or 75Watt Fusion, please request it at time of ordering.
5. Setting Vector Cutting Table Default If you have ordered the optional Vector Cutting Table, install it into your system (see “Installation of the Vector Cutting Table” on page 119). On the Fusion Control Panel, use the Joystick to scroll down until Settings is highlighted. Use the Joystick to scroll through the options until you see Vector Grid In. This indicates if the Vector Cutting Table is installed.
Center click to gain access, tilt the Joystick up or down to toggle to Yes if the Vector Cutting Table is installed. Press the Go key to make your change permanent.
6. Connect the Laser to Your Computer You are now ready to connect your computer to the laser. The following connections can be used:
1. USB only connection: You can use the USB port for the print driver and Epilog Job Manager. Multiple laser systems cannot be operated from a single computer through the USB connections. If you are using the USB connection, you will need one computer for each laser system.
2. Ethernet only connection: With an Ethernet connection you can print from the Laser Dashboard and use the Epilog Job Manager.
3. If you are using the optional eView Camera Module, you will need to use both USB and Ethernet connection. For this connection, please see “Attaching the eView Camera System to Your Computer” on page 141.
Electrical Connection 110/220 V - 50/60 Hz recommended using 208/220/240 volt electrical power to achieve maximum performance. If you would like a 220V cord for your 60 or 75Watt Fusion, please request it at time of ordering.
NEMA L6-15R
plug type
File details come from the government source that posted it. Updated .