This document is a Contract Data Requirements List (CDRL) for Commercial Off-The-Shelf (COTS) Manuals and Associated Supplemental Data, specifically an Operator/Service Manual for a Single-CMM Dryer/Filter system. The CDRL (DD Form 1423-1) outlines requirements for contractors to provide commercially available operator and service manuals with each system delivered, with electronic submissions preferred in MS-Excel or MS Word format on CD-ROM or DVD media.

The document is associated with a naval contract opportunity (Solicitation Number N6426725Q4112) issued by the Department of the Navy Naval Sea Systems Command. Distribution of the manual is limited to U.S. Government Agencies and their contractors, with a Distribution Statement C classification. The manuals shall be submitted to multiple addressees, including NAWCAD BL31400 at Joint Base MDL in Lakehurst, NJ, and NAVAIR Metrology and Calibration in Patuxent River, MD. One operator/service manual must be shipped with each Calibration Standard installed.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD FORM 1423-1, FEB 2001

CONTRACT DATA REQUIREMENTS LIST

(1 Data Item)

PREVIOUS EDITION MAY BE USED.

Form Approved OMB No. 0704-0188

The public reporting burden for this collection of information is estimated to average 110 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to the Department of Defense, Executive Services and Communications Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. Please do not return your form to the above organization. Send completed form to the Government Issuing Contracting Officer for the Contract/PR No. listed in Block E.

A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY:

TDP ________ TM _______ OTHER

D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR

1. DATA ITEM NO. 2. TITLE OF DATA ITEM 3. SUBTITLE

4. AUTHORITY (Data Acquisition Document No.) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE

7. DD 250 REQ

8. APP CODE

9. DIST STATEMENT

REQUIRED

10. FREQUENCY

11. AS OF DATE

12. DATE OF FIRST SUBMISSION

13. DATE OF SUBSEQUENT

SUBMISSION

14. DISTRIBUTION

a. ADDRESSEE

b. COPIES

Draft Final

Reg Repro

15. TOTAL

16. REMARKS

17. PRICE GROUP

18. ESTIMATED

TOTAL PRICE

G. PREPARED BY H. DATE I. APPROVED BY J. DATE

Page of Pages

TBD A TMS

Single-CMM Dryer / Filter N64267-25-R-XXXX TBD

T001 Commercial Off-The-Shelf (COTS) Manuals and Associated Supplemental Data

Operator/Service Manual

DI-TMSS-80527D (See Block 16) SOW Paragraph: 5.1.1 (See Block 16) NAWCAD BL31400

XX

N/A C (See Block 16)

(See Block 16)

N/A

(See Block 16)

(See Block 16) 1 1

NAWCAD BL31400

1 1 0

NAWCAD AA1420

1 1 0

NAWCAD BL31400

Copies with each uni 0 1 0

3 4 0

Block 4/5: DI-TMSS-80527D and SOW paragraph 5.3.1 is mandatory to this requirement and shall be used as guidance and are provided for reference.

Block 9: DISTRIBUTION Statement "C" will be added in accordance with DoD Directive 5230.24. Distribution Statement C. Distribution authorized to U.S.

Government Agencies and their contractors to protect publications required for official use or for administration or operational purposes only. (31 Oct. 2023).

Other requests for this document shall be referred to NAWCAD Metrology and Calibration Office, ATTN: Calibration Standards Manager, NAWCAD, NAS Patuxent River, MD 20670-1118.

Block 10 Frequency: Contractor shall provide a the commercially available Operators/Service Manual(s) with each system

Block 12/13: Date of Subsequent: Submissions of Operator/Service Manual(s) shall be provided with each new system being delivered.

Block 14: Submission in contractor format is acceptable. Electronic format is desired and acceptable if in MS-Excel or MS Word. Electronic submission of data shall also be on CD-ROM and/or DvD media. Qty. (1) Operator/Service Manual shall be shipped with each Calibration Standard installed. Quantity and copies shall be provided IAW CDRL T001 distribution ( Copies with each unit delivered) Block 14a. Addressee's POC information provided on CDRL supplemental page 2.

Block 14: Submission in contractor format is acceptable. Electronic format is desired and acceptable if in MS-Excel or MS Word. Electronic submission of data shall also be on CD-ROM and/or DvD media. Qty. (1) Operator/Service Manual shall be shipped with each Calibration Standard installed. Quantity and copies shall be provided IAW CDRL T001 distribution (Block 14a). Addressee's POC information provided on CDRL supplemental page 2.

NAWCAD BL31400

JB MDL

Highway 547, Lakehurst, NJ 08733

NAVAIR Metrology and Calibration

NAWCAD BL31400

JB MDL

Highway 547, Lakehurst, NJ 08733

NAVAIR METCAL AA14200

22113 Fortin Circle, Unit 7 Patuxent River, MD 20670