6c -Technical Exhibit 3.xlsx
XLSX spreadsheet 13 KB Posted
- Attached to
- H312--Service Water Based Fire Protection System Federal contract opportunity
- Solicitation number
- 36C25221Q0436
About this file
This technical exhibit provides data on the water-based fire protection system components at various buildings on a university campus. It lists the number of risers, control valves, water pressure gauges, air pressure gauges, dry pipe valves, preaction valves, air compressors, valve tamper switches, waterflow alarms, fire department connections, check valves, hose valves, backflow preventers, and dry barrel fire hydrants for each building. The approximate square footage of coverage is also provided for each building.
The related federal contract opportunity is a solicitation to provide inspection, testing, and maintenance services for water-based fire protection systems, commercial cooking fire protection systems, portable fire extinguishing equipment, and fire alarm and detection systems at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The solicitation is issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25221Q0436 0002.docx | DOCX document | |
| 36C25221Q0436 0001.docx | DOCX document | |
| 6e - Technical Exhibit 5.xlsx | XLSX spreadsheet | |
| 6d - Technical Exhibit 4.xlsx | XLSX spreadsheet | |
| 36C25221Q0436_1.docx | DOCX document | |
| 6b - Technical Exhibit 2.xlsx | XLSX spreadsheet | |
| P07-WD 2015-4899 RV14-7-21-21.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Water-Based Data
| Technical Exhibit 3 | ||||||||||||||||||
| Water-Based Fire Protection System Data | ||||||||||||||||||
| Building Number | ||||||||||||||||||
| Sprinkler system component | 4 | 5 | 6 | 7 | 11 | 43 | 70 | 102 | 109 | 111 | 123 | 144 | 146 | 147 | 148 | 150 | Campus | Totals |
| Riser | 1 | 2 | 5 | 2 | 1 | 1 | 4 | 1 | 1 | 1 | 5 | 1 | 2 | 2 | 2 | 1 | 0 | 32 |
| Control valve | 3 | 6 | 6 | 5 | 2 | 16 | 12 | 5 | 3 | 92 | 15 | 6 | 5 | 5 | 5 | 1 | 0 | 187 |
| Water pressure gauge | 0 | 2 | 5 | 2 | 1 | 13 | 7 | 2 | 1 | 84 | 5 | 4 | 2 | 2 | 2 | 1 | 0 | 133 |
| Air pressure gauge | 0 | 1 | 8 | 1 | 0 | 0 | 4 | 0 | 0 | 6 | 0 | 0 | 2 | 2 | 2 | 0 | 0 | 26 |
| Dry pipe valve | 0 | 1 | 5 | 1 | 0 | 0 | 0 | 0 | 0 | 2 | 0 | 0 | 2 | 2 | 2 | 0 | 0 | 15 |
| Preaction valve | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5 |
| Air compressor | 0 | 2 | 4 | 0 | 0 | 0 | 1 | 0 | 0 | 3 | 0 | 0 | 1 | 1 | 1 | 0 | 0 | 13 |
| Valve tamper switch | 3 | 5 | 6 | 5 | 0 | 16 | 7 | 5 | 3 | 92 | 15 | 6 | 4 | 4 | 4 | 1 | 0 | 176 |
| Waterflow alarm | 1 | 2 | 5 | 2 | 1 | 15 | 9 | 2 | 1 | 81 | 5 | 4 | 2 | 2 | 2 | 1 | 0 | 135 |
| Fire department connection | 0 | 1 | 4 | 1 | 1 | 1 | 2 | 1 | 1 | 5 | 5 | 1 | 1 | 1 | 1 | 1 | 0 | 27 |
| Check valve | 0 | 2 | 8 | 2 | 1 | 1 | 2 | 1 | 2 | 11 | 5 | 1 | 1 | 1 | 1 | 1 | 0 | 40 |
| Hose valve | 0 | 0 | 0 | 0 | 0 | 10 | 0 | 0 | 0 | 64 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 74 |
| Backflow preventer | 1 | 0 | 0 | 0 | 1 | 1 | 4 | 1 | 1 | 1 | 5 | 1 | 1 | 1 | 1 | 1 | 0 | 20 |
| Approximate square footage of coverage | 500 | 29,000 | 130,500 | 31,500 | 6,500 | 71,000 | 23,500 | 28,500 | 4,000 | 824,500 | 90,500 | 68,000 | 8,500 | 8,500 | 8,500 | 12,500 | N/A | 1,346,000 |
| Dry barrel fire hydrant | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 48 | 48 |