6b - Technical Exhibit 2.xlsx

XLSX spreadsheet 15 KB Posted

Attached to
H312--Service Water Based Fire Protection System Federal contract opportunity
Solicitation number
36C25221Q0436
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

This document contains a technical exhibit detailing the fire alarm system components at various buildings on a Department of Veterans Affairs medical center campus, along with the related federal contract opportunity to provide inspection, testing, and maintenance services for water-based fire protection systems, commercial cooking fire protection systems, portable fire extinguishing equipment, and fire alarm and detection systems at the location. Key details include specifications of over 25 buildings requiring 27 fire alarm control panels, 91 notification appliance circuit panels, 15 amplifiers, and over 1,300 smoke detectors, pull stations, strobes, speakers and other fire alarm components. The related solicitation is for ongoing services at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12.

View the file

Other files for this federal contract opportunity

Other files attached to H312--Service Water Based Fire Protection System, newest first.
File Type Posted
36C25221Q0436 0002.docx DOCX document
36C25221Q0436 0001.docx DOCX document
6c -Technical Exhibit 3.xlsx XLSX spreadsheet
P07-WD 2015-4899 RV14-7-21-21.pdf PDF
6e - Technical Exhibit 5.xlsx XLSX spreadsheet
6d - Technical Exhibit 4.xlsx XLSX spreadsheet
36C25221Q0436_1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fire Alarm Data

Technical Exhibit 2
Fire Alarm System Data
Building Number
Fire alarm system component34567*11*1720437097102107108109**113**115**111112123144146147148150151152Totals
Fire alarm control panel11111011111111010411111111127
Notification appliance circuit panel00042000013020000047014322200091
Amplifier000000000201000001000110000015
Pre-action releasing panel0000000001000000040000000005
Power extender0000000000000000000200000002
Fire alarm dialer0000000000000000010000000001
Annunciator00000100000000100302111110012
Duct smoke detector001013000022210100000830716222300182
Heat detector02231031120401000790218444443160
Smoke detector7624305222256918201202624766341634924242445111394
Pull station (pull box)46165019471418583723440167823145551000456
Elevators with recall/shunt trip011210012500000001200300011030
Firefighter telephone equipment00000000000000000118000200001121
Bell0000000200000000000000000002
Speaker3006330001520110440006411070111000289
Strobe3424682411415638144461043411134701221200910
A/V06203031007156052003109730215734353530001590
Door control0080400051500000001650115211700224
Battery testing222106022234282202013223410866222282
Notes:*Building 11 is slaved to Building 7's fire alarm control panel