This document provides details for a federal construction contract opportunity for the renovation of Samuel's Hall at the United States Merchant Marine Academy. The project involves hazardous materials abatement, interior demolition down to wall systems and concrete slabs, new teaching and support spaces including mechanical, electrical and plumbing systems, and select additive elements. The solicitation number is 693JF719B000006 and will be issued on or about August 1, 2019 as a total small business set-aside, with a business size standard of $36.5 million in average annual receipts. Interested offerors should register at FBO.gov. The bid submission date will be on or about November 1, 2019 and bids will be opened on the same date. The period of performance is approximately 365 days from notice to proceed. The contracting office is the Department of Transportation Maritime Administration located in Washington, D.C.
View the file
Other files for this federal contract opportunity
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Samuels Hall Renovation DOOR HARDWARE SETS United States Merchant Marine Academy Kings Point, New York
DCM Architecture & Engineering, LLC 080671 - 1 Project No. 16-609 March 27, 2019
SECTION 08 06 71-DOOR HARDWARE SETS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Sup-plementary Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section references specification sections relating to commercial door hard-ware for the following:
1. Swinging doors.
2. Other doors to the extent indicated.
B. Commercial door hardware includes, but is not necessarily limited to, the following:
1. Mechanical door hardware.
2. Electromechanical and access control door hardware.
3. Electromechanical and access control door hardware power supplies, back-ups and surge protection.
4. Automatic operators.
5. Cylinders specified for doors in other sections.
C. Related Sections:
1. Division 06 Section “Rough Carpentry”.
2. Division 06 Section “Finish Carpentry”.
3. Division 08 Section “Hollow Metal Doors and Frames”.
4. Division 08 Sections “Flush and Clad Wood Doors”.
5. Division 08 Section “Door Hardware”.
6. Division 28 Section “Access Control”.
D. Codes and References: Comply with the version year adopted by the Au-thority Having Jurisdiction.
1. ANSI A117.1 - Accessible and Usable Buildings and Facilities.
2. ICC/IBC - International Building Code.
3. NFPA 70 - National Electrica lCode.
4. NFPA 80 - Fire Doors and Windows.
5. NFPA 101 - Life Safety Code.
6. NFPA 105 - Installation of Smoke Door Assemblies.
7. UL/ULC and CSA C22.2 – Standards for Automatic Door Operators Used on Fire and Smoke Barrier Doors and Systems of Doors.
8. State Building Codes, Local Amendments.
E. Standards: All hardware specified herein shall comply with the following industry standards:
1. ANSI/BHMA Certified Product Standards - A156 Series
DOOR HARDWARE SETS Samuels Hall Renovation
080671 - 2 DCM Architecture & Engineering, LLC
2. UL10C – Positive Pressure Fire Tests of Door Assemblies
1.3 SUBMITTALS
A. Product Data: Manufacturer's product data sheets including installation details, material descriptions, dimensions of individual components and profiles, operational descrip-tions and finishes.
B. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication, and assembly of door hardware, as well as procedures and diagrams.
Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.
1. Format: Comply with scheduling sequence and vertical format in DHI's
"Sequence and Format for the Hardware Schedule."
2. Organization: Organize the Door Hardware Schedule into door hardware sets indicating complete designations of every item required for each door or opening. Organize door hardware sets in same order as in the Door Hard-ware Sets at the end of Part 3. Submittals that do not follow the same format and order as the Door Hardware Sets will be rejected and subject to resubmis-sion.
3. Content: Include the following information:
I. Type, style, function, size, label, hand, and finish of each door hardware item.
II. Manufacturer of each item.
III. Fastenings and other pertinent information.
IV. Location of door hardware set, cross-referenced to Drawings, both onfloor plans and in door and frame schedule.
V. Explanation of abbreviations, symbols, and codes contained in schedule.
VI. Mounting locations for door hardware.
VII. Door and frame sizes and materials.
VIII. Warranty information for each product.
4. Submittal Sequence: Submit the final Door Hardware Schedule at earliest possible date, particularly where approval of the Door Hardware Schedule must precede fabrication of other work that is critical in the Project construc-tion schedule. Include Product Data, Samples, Shop Drawings of other work affected by door hardware, and other information essential to the coordinated review of the Door Hardware Schedule.
C. Shop Drawings: Details of electrified access control hardware indicating the following:
1. Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer-installed and field-installed wiring. Include the following:
a. Elevation diagram of each unique access controlled opening showing location and interconnection of major system components with respect to their placement in the respective door openings.
b. Complete (risers, point-to-point) access control system block wiring diagrams.
c. Wiring instructions for each electronic component scheduled herein.
DCM Architecture & Engineering, LLC 080671 - 3
2. Electrical Coordination: Coordinate with related sections the voltages and wiring details required at electrically controlled and operated hardware openings.
D. Keying Schedule: After a keying meeting with the owner has taken place prepare a separate keying schedule detailing final instructions. Submit the keying schedule in electronic format. Include keying system explanation, door numbers, key set symbols, hardware set numbers and special instructions. Owner must approve submitted keying schedule prior to the ordering of permanent cylinders/cores.
E. Informational Submittals:
1. Product Test Reports: Indicating compliance with cycle testing requirements, based on evaluation of comprehensive tests performed by manufacturer and witnessed by a qualified independent testing agency.
F. Operating and Maintenance Manuals: Provide manufacturers operating and maintenance manuals for each item comprising the complete door hardware installation in quantity as required in Division 01, Closeout Submittals. The manual to include the name, address, and contact information of the manufacturers providing the hardware and their nearest service representatives. The final copies delivered after completion of the installation test to include "as built" modifications made during installation, checkout, and acceptance.
G. Warranties and Maintenance: Special warranties and maintenance agreements specified in the Related Sections.
1.4 QUALITY ASSURANCE
A. Manufacturers Qualifications: Engage qualified manufacturers with a minimum [5] years of documented experience in producing hardware and equipment similar to that indicated for this Project and that have a proven record of successful in-service performance.
B. Installer Qualifications: Installers, trained by the primary product manufacturers, with a minimum [3] years documented experience installing both standard and electrified builders hardware similar in material, design, and extent to that indi-cated for this Project and whose work has resulted in construction with a record of successful in-service performance.
C. Door Hardware Supplier Qualifications: Experienced commercial door hardware dis-tributors with a minimum [5] years documented experience supplying both mechani-cal and electromechanical hardware installations comparable in material, design, and extent to that indicated for this Project. Supplier recognized as a factory direct distrib-utor in good standing by the manufacturers of the primary materials with a warehous-ing facility in Project's vicinity. Sup- plier to have on staff a certified Architectural Hardware Consultant (AHC) available during the course of the Work to consult with Contractor, Architect, and Owner concerning both standard and electromechanical door hardware and keying.
D. Automatic Operator Supplier Qualifications: Power operator products and accessories are required to be supplied and installed through current members of the manufacturer's "Power Operator Preferred Installer" program. Suppliers are to be factory trained, certified, and a direct purchaser of the specified power operators and be responsible for the installation and maintenance of the units and accessories indicated for the Project.
080671 - 4 DCM Architecture & Engineering, LLC
March 27, 2019
E. Source Limitations: Obtain each type and variety of Door Hardware specified in the Related Sections from a single source, qualified supplier unless otherwise indicated.
1. Electrified modifications or enhancements made to a source manufacturer's product line by a secondary or third party source will not be accepted.
2. Provide electromechanical door hardware from the same manufacturer as mechanical door hardware, unless otherwise indicated.
F. Regulatory Requirements: Comply with NFPA 70, NFPA 80, NFPA 101 and ANSI A117.1 requirements and guidelines as directed in the applicable model building code.
G. Each unit to bear third party permanent label demonstrating compliance with the referenced standards.
H. Keying Conference: Conduct conference to comply with requirements in Division 01
Section "Project Meetings." Keying conference to incorporate the following criteria into the final keying schedule document:
1. Function of building, purpose of each area and degree of security required.
2. Plans for existing and future key system expansion.
3. Requirements for key control storage and software.
4. Installation of permanent keys, cylinder cores and software.
5. Address and requirements for delivery of keys.
I. Pre-Submittal Conference: Conduct coordination conference in compliance with requirements in Division 01 Section "Project Meetings" with attendance by representatives of Supplier(s), Installer(s), and Contractor(s) to review proper methods and the procedures for receiving, handling, and installing door hardware.
1. Prior to installation of door hardware, conduct a project specific training meeting to instruct the installing contractors' personnel on the proper installation and adjustment of their respective products. Product training to be attended by installers of door hardware (including electromechanical hardware) for aluminum, hollow metal and wood doors. Training will include the use of installation manuals, hardware schedules, templates and physical product samples as required.
2. Inspect and discuss electrical roughing-in, power supply connections, and other preparatory work performed by other trades.
3. Review sequence of operation narratives for each unique access controlled opening.
4. Review and finalize construction schedule and verify availability of materials.
5. Review the required inspecting, testing, commissioning, and demonstration procedures J. At completion of installation, provide written documentation that components were applied to manufacturer's instructions and recommendations and according to approved schedule.
1.5 DELIVERY, STORAGE, ANDHANDLING
A. Inventory door hardware on receipt and provide secure lock-up and shelving for door hard- ware delivered to Project site. Do not store electronic access control hardware, software or accessories at Project site without prior authorization.
B. Tag each item or package separately with identification related to the final
Door Hard- ware Schedule, and include basic installation instructions with
DCM Architecture & Engineering, LLC 080671 - 5 each item or package.
C. Deliver, as applicable, permanent keys, cylinders, cores, access control creden-tials, soft- ware and related accessories directly to Owner via registered mail or overnight package service. Instructions for delivery to the Owner shall be estab-lished at the "Keying Confer- ence".
1.6 COORDINATION
A. Templates: Obtain and distribute to the parties involved templates for doors, frames, and other work specified to be factory prepared for installing standard and electrified hardware. Check Shop Drawings of other work to confirm that adequate provisions are made for lo- cating and installing hardware to comply with indicated requirements.
B. Door Hardware and Electrical Connections: Coordinate the layout and installation of scheduled electrified door hardware and related access control equipment with required connections to source power junction boxes, low voltage power supplies, detection and monitoring hardware, and fire and detection alarm systems.
C. Door and Frame Preparation: Division 08 Sections (Steel, Aluminum and Wood) doors and corresponding frames are to be prepared, reinforced and pre-wired (if ap-plicable) to receive the installation of the specified electrified, monitoring, signaling and access control system hardware without additional in-fieldmodifications.
1.7 WARRANTY
A. General Warranty: Reference Division 01, General Requirements. Special warran-ties specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Contractor under requirements of the Contract Documents.
B. Warranty Period: Written warranty, executed by manufacturer(s), agreeing to repair or replace components of standard and electrified door hardware that fails in materials or workmanship within specified warranty period after final acceptance by the Owner.
Failures include, but are not limited to, the following:
1. Structural failures including excessive deflection, cracking, or breakage.
2. Faulty operation of the hardware.
3. Deterioration of metals, metal finishes, and other materials beyond normal weathering.
4. Electrical component defects and failures within the systems operation.
C. Standard Warranty Period: One year from date of Substantial Completion, unless otherwise indicated.
D. Special Warranty Periods:
1. Ten years for mortise locks and latches.
2. Five years for exit hardware.
3. Five years for motorized electric latch retraction exit devices.
4. Two years for electromechanical door hardware.
1.8 MAINTENANCE SERVICE
080671 - 6 DCM Architecture & Engineering, LLC
A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjust-ment, maintenance, and removal and replacement of door hardware.
PART 2 - PRODUCTS
2.1 SCHEDULED DOOR HARDWARE
A. General: Provide door hardware for each door to comply with requirements in Door Hardware Sets and each referenced section that products are to be supplied under.
B. Designations: Requirements for quantity, item, size, finish or color, grade, function, and other distinctive qualities of each type of door hardware are indicated in the Door Hardware Sets at the end of Part 3. Products are identified by using door hardware designations, as follows:
1. Named Manufacturer's Products: Product designation and manufacturer are listed for each door hardware type required for the purpose of establishing requirements.
Manufacturers' names are abbreviated in the Door Hardware Schedule.
C. Substitutions: Requests for substitution and product approval for inclusive mechanical and electromechanical door hardware in compliance with the specifications must be submitted in writing and in accordance with the procedures and time frames outlined in Division 01, Substitution Procedures. Approval of requests is at the discretion of the architect, owner, and their designated consultants.
2.2 HANGING DEVICES
A. Hinges: ANSI/BHMA A156.1 certified butt hinges with number of hinge knuckles and other options as specified in the Door Hardware Sets.
1. Quantity: Provide the following hinge quantity:
a. Two Hinges: For doors with heights up to 60 inches.
b. Three Hinges: For doors with heights 61 to 90 inches.
c. Four Hinges: For doors with heights 91 to 120 inches.
d. For doors with heights more than 120 inches, provide 4 hinges, plus 1 hinge for every 30 inches of door height greater than 120 inches.
2. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door thickness and clearances required:
a. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified.
b. Sizes from 3’1” to 4’0”: 5” standard or heavy weight as specified.
3. Hinge Weight and Base Material: Unless otherwise indicated, provide the following:
a. Exterior Doors: Heavy weight, non-ferrous, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate standard weight.
b. Interior Doors: Standard weight, steel, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate heavy weight.
4. Hinge Options: Comply with the following:
a. Non-removable Pins: Provide set screw in hinge barrel that, when tightened into a groove in hinge pin, prevents removal of pin while door is closed; for the all out-swinging lockable doors.
DCM Architecture & Engineering, LLC 080671 - 7
5. Manufacturers:
a. Bommer Industries (BO).
b. Hager Companies (HA).
c. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK).
B. Pivots: ANSI/BHMA A156.4, Grade 1, certified. Space intermediate pivots equally not less than 25 inches on center apart or not more than 35 inches on center for doors over 121 inches high. Pivot hinges to have oil impregnated bronze bearing in the top pivot and a radial roller and thrust bearing in the bottom pivot with the bottom pivot designed to carry the full weight of the door. Pivots to be UL listed for windstorm where applicable.
1. Manufacturers:
a. Architectural Builders Hardware (AH).
b. Rixson Door Controls (RF).
2.3 POWER TRANSFER DEVICES
A. Electrified Quick Connect Transfer Hinges: Provide electrified transfer hinges with Molex™ standardized plug connectors and sufficient number of concealed wires (up to 12) to accommodate the electrified functions specified in the Door Hardware Sets. Connectors plug directly to through-door wiring harnesses for connection to electric locking devices and power supplies. Wire nut connections are not acceptable.
1. Manufacturers:
a. Hager Companies (HA) - ETW-QC (# wires) Option.
b. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK)
- QC (# wires) Option.
B. Electrified Quick Connect Intermediate Transfer Pivots: Provide electrified offset intermediate transfer pivot hinges with Molex™ standardized plug connectors and sufficient number of concealed wires (up to 12) to accommodate the electrified functions specified in the Door Hardware Sets. Connectors plug directly to through-door wiring harnesses for connection to electric locking devices and power supplies. Wire nut connections are not acceptable.
1. Manufacturers:
a. Rixson Door Controls (RF) - E-M19-QC (# wires).
C. Electric Door Wire Harnesses: Provide electric/data transfer wiring harnesses with standardized plug connectors to accommodate up to twelve (12) wires. Connectors plug directly to through-door wiring harnesses for connection to electric locking devices and power supplies. Provide sufficient number and type of concealed wires to accommodate electric function of specified hardware. Provide a connector for through-door electronic locking devices and from hinge to junction box above the opening. Wire nut connections are not acceptable. Determine the length required for each electrified hardware component for the door type, size and construction, minimum of two per electrified opening.
1. Provide one each of the following tools as part of the base bid contract:
a. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK)
- Electrical Connecting Kit: QC-R001.
b. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK)
- Connector Hand Tool: QC-R003.
2. Manufacturers:
a. Hager Companies (HA) - Quick Connect.
b. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK)
– QC-C Series.
080671 - 8 DCM Architecture & Engineering, LLC
March 27, 2019
2.4 DOOR OPERATING TRIM
A. Flush Bolts and Surface Bolts: ANSI/BHMA A156.3 and A156.16, Grade 1, certified.
1. Flush bolts to be furnished with top rod of sufficient length to allow bolt retraction device location approximately six feet from the floor.
2. Furnish dust proof strikes for bottom bolts.
3. Surface bolts to be minimum 8” in length and U.L. listed for labeled fire doors and U.L.
listed for windstorm components where applicable.
4. Provide related accessories (mounting brackets, strikes, coordinators, etc.) as required for appropriate installation and operation.
5. Manufacturers:
a. Burns Manufacturing (BU).
b. Door Controls International (DC).
c. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).
B. Door Push Plates and Pulls: ANSI/BHMA A156.6 certified door pushes and pulls of type and design specified in the Hardware Sets. Coordinate and provide proper width and height as required where conflicting hardware dictates.
1. Push/Pull Plates: Minimum .050 inch thick, size as indicated in hardware sets, with beveled edges, secured with exposed screws unless otherwise indicated.
2. Door Pull and Push Bar Design: Size, shape, and material as indicated in the hardware sets. Minimum clearance of 2 1/2-inches from face of door unless otherwise indicated.
3. Offset Pull Design: Size, shape, and material as indicated in the hardware sets.
Minimum clearance of 2 1/2-inches from face of door and offset of 90 degrees unless otherwise indicated.
4. Fasteners: Provide manufacturer's designated fastener type as indicated in Hardware Sets.
5. Manufacturers:
a. Burns Manufacturing (BU).
b. Hiawatha, Inc. (HI).
c. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).
2.5 CYLINDERS AND KEYING
A. General: Cylinder manufacturer to have minimum (10) years experience designing secured master key systems and have on record a published security keying system policy.
B. Source Limitations: Obtain each type of keyed cylinder and keys from the same source manufacturer as locksets and exit devices, unless otherwise indicated.
1. Manufacturers:
a. Sargent Manufacturing (SA).
b. No Substitution.
C. Cylinders: Original manufacturer cylinders complying with the following:
1. Mortise Type: Threaded cylinders with rings and cams to suit hardware application.
2. Rim Type: Cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised trim ring.
3. Bored-Lock Type: Cylinders with tailpieces to suit locks.
4. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be flush and be free spinning with matching finishes.
5. Keyway: Match Facility Standard.
D. Keying System: Each type of lock and cylinders to be factory keyed.
1. Conduct specified "Keying Conference" to define and document keying system instructions and requirements.
DCM Architecture & Engineering, LLC 080671 - 9
March 27, 2019
2. Furnish factory cut, nickel-silver large bow permanently inscribed with a visual key control number as directed by Owner.
3. Existing System: Key locks to Owner's existing system.
E. Key Quantity: Provide the following minimum number of keys:
1. Change Keys per Cylinder: Two (2)
2. Master Keys (per Master Key Level/Group): Five (5).
3. Construction Keys (where required): Ten (10).
F. Construction Keying: Provide construction master keyed cylinders.
G. Key Registration List (Bitting List):
1. Provide keying transcript list to Owner's representative in the proper format for importing into key control software.
2. Provide transcript list in writing or electronic file as directed by the Owner.
H. Key Control Cabinet: Provide a key control system including envelopes, labels, and tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet. Key control cabinet shall have expansion capacity of 150% of the number of locks required for the project.
1. Manufacturers:
a. Lund Equipment (LU).
b. MMF Industries (MM).
c. Telkee (TK).
I. Key Control Software: Provide one network version of "Key Wizard" branded key management software package that includes one year of technical support and upgrades to software at no charge. Provide factory key system formatted for importing into “Key Wizard” software.
2.6 MECHANICAL LOCKS AND LATCHING DEVICES
A. Mortise Locksets, Grade 1 (Heavy Duty): ANSI/BHMA A156.13, Series 1000, Operational
Grade 1 certified. Locksets are to be manufactured with a corrosion resistant steel case and be field-reversible for handing without disassembly of the lock body.
1. Manufacturers:
a. Corbin Russwin Hardware (RU) – ML2000 Series.
b. Sargent Manufacturing (SA) – 8200 Series.
c. Schlage (SC) – L9000 Series.
2.7 LOCK AND LATCH STRIKES
A. Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated, and as follows:
1. Flat-Lip Strikes: For locks with three-piece antifriction latchbolts, as recommended by manufacturer.
2. Extra-Long-Lip Strikes: For locks used on frames with applied wood casing trim.
3. Aluminum-Frame Strike Box: Provide manufacturer's special strike box fabricated for aluminum framing.
4. Double-lipped strikes: For locks at double acting doors. Furnish with retractable stop for rescue hardware applications.
080671 - 10 DCM Architecture & Engineering, LLC
March 27, 2019
B. Standards: Comply with the following:
1. Strikes for Mortise Locks and Latches: BHMA A156.13.
2. Strikes for Bored Locks and Latches: BHMA A156.2.
3. Strikes for Auxiliary Deadlocks: BHMA A156.36.
4. Dustproof Strikes: BHMA A156.16.
2.8 CONVENTIONAL EXIT DEVICES
A. General Requirements: All exit devices specified herein shall meet or exceed the following criteria:
1. At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed and labeled for "Panic Hardware" according to UL305. Provide proper fasteners as required by manufacturer including sex nuts and bolts at openings specified in the Hardware Sets.
2. Where exit devices are required on fire rated doors, provide devices complying with NFPA 80 and with UL labeling indicating "Fire Exit Hardware". Provide devices with the proper fasteners for installation as tested and listed by UL. Consult manufacturer’s catalog and template book for specific requirements.
3. Except on fire rated doors, provide exit devices with hex key dogging device to hold the pushbar and latch in a retracted position. Provide optional keyed cylinder dogging on devices where specified in Hardware Sets.
4. Devices must fit flat against the door face with no gap that permits unauthorized dogging of the push bar. The addition of filler strips is required in any case where the door light extends behind the device as in a full glass configuration.
5. Electromechanical Options: Subject to same compliance standards and requirements as mechanical exit devices, electrified devices to be of type and design as specified in hardware sets. Include any specific controllers when conventional power supplies are not sufficient to provide the proper inrush current.
6. Motorized Electric Latch Retraction: Devices with an electric latch retraction feature must use motors which have a maximum current draw of 600mA. Solenoid driven latch retraction is not acceptable.
7. Lever Operating Trim: Where exit devices require lever trim, furnish manufacturer's heavy duty escutcheon trim with threaded studs for thru-bolts.
a. Lock Trim Design: As indicated in Hardware Sets, provide finishes and designs to match that of the specified locksets.
b. Where function of exit device requires a cylinder, provide a cylinder (Rim or Mortise) as specified in Hardware Sets.
8. Vertical Rod Exit Devices: Where surface or concealed vertical rod exit devices are used at interior openings, provide as less bottom rod (LBR) unless otherwise indicated. Provide dust proof strikes where thermal pins are required to project into the floor.
9. Narrow Stile Applications: At doors constructed with narrow stiles, or as specified in Hardware Sets, provide devices designed for maximum 2” wide stiles.
10. Dummy Push Bar: Nonfunctioning push bar matching functional push bar.
11. Extended cycle test: Devices to have been cycle tested in ordinance with ANSI/BHMA
156.3 requirements to 9 million cycles.
12. Rail Sizing: Provide exit device rails factory sized for proper door width application.
13. Through Bolt Installation: For exit devices and trim as indicated in Door Hardware Sets.
B. Conventional Push Rail Exit Devices (Heavy Duty): ANSI/BHMA A156.3, Grade 1 certified panic and fire exit hardware devices furnished in the functions specified in the Hardware Sets. Exit device latch to be stainless steel, pullman type, with deadlock feature.
1. Manufacturers:
a. Corbin Russwin Hardware (RU) - ED4000 / ED5000 Series.
b. Sargent Manufacturing (SA) - 80 Series.
DCM Architecture & Engineering, LLC 080671 - 11
March 27, 2019
c. Stanley Precision (PR) - Apex 2000 Series.
2.9 DOOR CLOSERS
A. All door closers specified herein shall meet or exceed the following criteria:
1. General: Door closers to be from one manufacturer, matching in design and style, with the same type door preparations and templates regardless of application or spring size.
Closers to be non-handed with full sized covers including installation and adjusting information on inside of cover.
2. Standards: Closers to comply with UL-10C for Positive Pressure Fire Test and be U.L.
listed for use of fire rated doors.
3. Cycle Testing: Provide closers which have surpassed 15 million cycles in a test witnessed and verified by UL.
4. Size of Units: Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use.
Where closers are indicated for doors required to be accessible to the physically handicapped, provide units complying with ANSI ICC/A117.1.
5. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in Hardware Sets.
6. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics.
7. Closer Accessories: Provide door closer accessories including custom templates, special mounting brackets, spacers and drop plates as required for proper installation. Provide through-bolt and security type fasteners as specified in the hardware sets.
B. Door Closers, Surface Mounted (Heavy Duty): ANSI/BHMA A156.4, Grade 1 surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6;
and fully operational adjustable according to door size, frequency of use, and opening force. Closers to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control. Provide non-handed units standard.
1. Manufacturers:
a. Corbin Russwin Hardware (RU) - DC6000 Series.
b. Sargent Manufacturing (SA) - 351 Series.
c. Norton Door Controls (NO) - 7500 Series.
2.10 SURFACE MOUNTED CLOSER HOLDERS
A. Electromagnetic Door Holders: Certified ANSI A156.15 electromagnetic door holder/releases with a minimum 20 to 40 pounds holding power and single coil construction able to accommodate.12VDC, 24VAC, 24VDC and 120VAC. Coils to be independently wound, employing an integral fuse and armatures to include a positive release button.
1. Manufacturers:
a. Rixson (RF) - 980/990 Series.
b. Sargent Manufacturing (SA) - 1560 Series.
2.11 ARCHITECTURAL TRIM
A. Door Protective Trim
1. General: Door protective trim units to be of type and design as specified below or in the Hardware Sets.
2. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door width (LDW) on stop side of single doors and 1” LDW on stop side of pairs of doors, and not more than 1" less than door width on pull side. Coordinate and provide proper width
080671 - 12 DCM Architecture & Engineering, LLC
March 27, 2019 and height as required where conflicting hardware dictates. Height to be as specified in the Hardware Sets.
3. Where plates are applied to fire rated doors with the top of the plate more than 16” above the bottom of the door, provide plates complying with NFPA 80. Consult manufacturer’s catalog and template book for specific requirements for size and applications.
4. Protection Plates: ANSI/BHMA A156.6 certified protection plates (kick, armor, or mop), fabricated from the following:
a. Stainless Steel: 300 grade, 050-inch thick.
5. Options and fasteners: Provide manufacturer's designated fastener type as specified in the
Hardware Sets. Provide countersunk screw holes.
6. Manufacturers:
a. Burns Manufacturing (BU).
b. Hiawatha, Inc. (HI).
c. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).
2.12 DOOR STOPS AND HOLDERS
A. General: Door stops and holders to be of type and design as specified below or in the
Hardware Sets.
B. Door Stops and Bumpers: ANSI/BHMA A156.16, Grade 1 certified door stops and wall bumpers. Provide wall bumpers, either convex or concave types with anchorage as indicated, unless floor or other types of door stops are specified in Hardware Sets. Do not mount floor stops where they will impede traffic. Where floor or wall bumpers are not appropriate, provide overhead type stops and holders.
1. Manufacturers:
a. Burns Manufacturing (BU).
b. Hiawatha, Inc. (HI).
c. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).
C. Overhead Door Stops and Holders: ANSI/BHMA A156.6, Grade 1 certified overhead stops and holders to be surface or concealed types as indicated in Hardware Sets. Track, slide, arm and jamb bracket to be constructed of extruded bronze and shock absorber spring of heavy tempered steel. Provide non-handed design with mounting brackets as required for proper operation and function.
1. Manufacturers:
a. Rixson Door Controls (RF).
b. Sargent Manufacturing (SA).
2.13 ARCHITECTURAL SEALS
A. General: Thresholds, weatherstripping, and gasket seals to be of type and design as specified below or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated. At exterior applications provide non-corrosive fasteners and elsewhere where indicated.
B. Smoke Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke control ratings indicated, based on testing according to UL 1784.
1. Provide smoke labeled perimeter gasketing at all smoke labeled openings.
C. Fire Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to UL-10C.
1. Provide intumescent seals as indicated to meet UL10C Standard for Positive Pressure Fire Tests of Door Assemblies, and NPFA 252, Standard Methods of Fire Tests of Door Assemblies.
DCM Architecture & Engineering, LLC 080671 - 13
March 27, 2019
D. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting agency, for sound ratings indicated.
E. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are easily replaceable and readily available from stocks maintained by manufacturer.
F. Manufacturers:
1. National Guard Products (NG).
2. Pemko Products; ASSA ABLOY Architectural Door Accessories (PE).
3. Reese Enterprises, Inc. (RE).
2.14 ELECTRONIC ACCESSORIES
A. Key Switches: Key switches furnished standard with stainless steel single gang face plate with a 12/24VDC bi-color LED indicator. Integral backing bracket permits integration with any 1 1/4" or 1 1/2" mortise type cylinder. Key switches available as momentary or maintained action and in narrow face plate options.
1. Manufacturers:
a. Security Door Controls (SD) - 800 Series.
b. Securitron (SU) - MK Series.
B. Door Position Switches: Door position magnetic reed contact switches specifically designed for use in commercial door applications. On recessed models the contact and magnetic housing snap-lock into a 1" diameter hole. Surface mounted models include wide gap distance design complete with armored flex cabling. Provide SPDT, N/O switches with optional Rare Earth Magnet installation on steel doors with flush top channels.
1. Manufacturers:
a. Sargent Manufacturing (SA) – 3280 Series.
b. Securitron (SU) - DPS Series.
C. Power Supplies: Provide Nationally Recognized Testing Laboratory Listed 12VDC or 24VDC (field selectable) filtered and regulated power supplies. Include battery backup option with integral battery charging capability in addition to operating the DC load in event of line voltage failure. Provide the least number of units, at the appropriate amperage level, sufficient to exceed the required total draw for the specified electrified hardware and access control equipment.
1. Manufacturers:
a. Corbin Russwin Hardware (RU) - BPS Series.
b. Sargent Manufacturing (SA) - 3500 Series.
c. Securitron (SU) - BPS Series.
2.15 FABRICATION
A. Fasteners: Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. Provide screws according to manufacturers recognized installation standards for application intended.
2.16 FINISHES
A. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes indicated by certain manufacturers for their products.
B. Provide quality of finish, including thickness of plating or coating (if any), composition, hardness, and other qualities complying with manufacturer's standards, but in no case less than specified by referenced standards for the applicable units of hardware
C. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
080671 - 14 DCM Architecture & Engineering, LLC
PART 3 - EXECUTION
3.1 DOOR HARDWARE SETS
A. The door hardware sets represent the design intent and direction of the owner and architect. They are a guideline only and should not be considered a detailed hard-ware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.
B. The supplier is responsible for handing and sizing all products as listed in the door hardware sets. Quantities listed are for each pair of doors, or for each single door.
C. Products listed in the Door Hardware Sets must meet the requirements described in the specification sections noted.
1. Section 08 71 00 – Door Hardware.
D. Manufacturer’s Abbreviations:
1. MK - McKinney
2. RF - Rixson
3. RO - Rockwood
4. SA - Sargent
5. NO – Norton
6. PE – Pemko
7. OT- Other
8. SU - Securitron
Hardware Schedule
Set: 1.0 Doors: 101, C103, C103.2
Pivot Set 147 626 RF
Electrified Inter Pivot EM19 QC 626 RF
Exit Device (nightlatch) 55 56 AD8410 106 MK US32D SA
Exit Device (exit only) 55 AD8410 US32D SA
Door Pull RM3301-48 US32D RO
Surface Closer (P/PRO)7500 M 689 NO
Door Stop RM861/RM855 US26D RO
Threshold 273x3AFG MSES25SS PE
Gasketing By Door/Frame Supplier OT
Frame Harness QC-C1500P MK
DCM Architecture & Engineering, LLC 080671 - 15
March 27, 2019
Door Harness QC-CX sized for hinge to locking hard-ware
MK
Wiring Diagram By Security Vendor OT
Position Switch DPS-M-BK SU
Card Reader HSPD12 By Security Vendor OT
Power Supply BPS-24 (amps as required) SU
Notes: Doors normally closed and locked, use of valid credential to retract exit device rail to allow pull entry. Free egress always allowed from interior.
Set: 1.1 Doors: 201
Electrified Inter Pivot EM19 QC 626 RF
Exit Device (nightlatch) 55 56 AD8410 106 MK US32D SA
Exit Device (exit only) 55 56 AD8410 US32D SA
Cylinder As Required US32D SA
Door Pull RM3301-48 US32D RO
Door Operator 6010/6020 689 NO
Door Stop RM861/RM855 US26D RO
Threshold 273x3AFG MSES25SS PE
Gasketing By Door/Frame Supplier OT
Frame Harness QC-C1500P MK
Door Harness QC-CX sized for hinge to locking hard-ware
MK
Wiring Diagram By Security Vendor OT
Position Switch DPS-M-BK SU
Keyswitch MKA SU
Door Switch 505 NO
Notes: Doors normally closed and locked, use of valid credential to retract exit device rail to allow pull entry. Free egress always allowed from interior. Exterior operator button normally inoperable, activation of key switch to enable exterior operator button and electronically dog down both exit de-vices for daily push/pull use. Interior operator button always active; use of authorized credential on exterior to active exterior operator button for use.
080671 - 16 DCM Architecture & Engineering, LLC
March 27, 2019
Set: 2.0 Doors: ST-1-100.1, ST-1-200
Hinge (heavy weight) TA386 NRP US32D MK
Exit Device (exit only) (12) 8810 US32D SA
Surface Closer (P/PRO)7500 M 689 NO
Kick Plate K1050 10" CSK BEV US32D RO
Door Stop RM861/RM855 US26D RO
Threshold 273x3AFG MSES25SS PE
Gasketing 303AS TKSP PE
Door Bottom 217AV TKSP PE
Set: 2.1 Doors: ST-1-400
Hinge TA314 NRP US32D MK
Storeroom Lock 8204 LNP MK US26D SA
Surface Closer (P/PRO)7500 M 689 NO
Kick Plate K1050 10" CSK BEV US32D RO
Door Stop RM861/RM855 US26D RO
Threshold 273x3AFG MSES25SS PE
Gasketing 303AS TKSP PE
Door Bottom 217AV TKSP PE
Set: 3.0 Doors: 201.1, C103.1
Intermediate Pivot M19 626 RF
Door Pull RM3301-48 US32D RO
Push Bar RM3301 (width as required) US32D RO
Surface Closer (P/PRO)7500 M 689 NO
Door Stop RM861/RM855 US26D RO
Gasketing By Door/Frame Supplier OT
DCM Architecture & Engineering, LLC 080671 - 17
March 27, 2019
Set: 4.0 Doors: 202, 202.2
6 Hinge (heavy weight) TA786 US26D MK
2 Exit Device (classroom) (12) NB8713 ETP MK US32D SA
2 Surface Closer (P/PRO)7500 M 689 NO
2 Kick Plate K1050 10" CSK BEV US32D RO
2 Door Stop RM861/RM855 US26D RO
1 Gasketing S44BL (rated openings only) PE
1 Astragal 18041CNB (rated openings only) PE
Set: 5.0
Doors: 202.1, 202.5
3 Hinge (heavy weight) TA786 US26D MK
1 Exit Device (classroom) (12) 8813 ETP MK US32D SA
1 Surface Closer (P/PRO)7500 M 689 NO
1 Kick Plate K1050 10" CSK BEV US32D RO
1 Door Stop RM861/RM855 US26D RO
Set: 6.0
Doors: 107, 107.1
Hinge (heavy weight) TA786 US26D MK
Surface Vert Rod Exit (12) NB8710 ETP US32D SA
Surface Closer (P/PRO)7500 M 689 NO
Kick Plate K1050 10" CSK BEV US32D RO
Electromagnetic Holder 980/994M 689 RF
Gasketing S44BL (rated openings only) PE
Astragal 18041CNB (rated openings only) PE
080671 - 18 DCM Architecture & Engineering, LLC
March 27, 2019
Set: 7.0 Doors: ST-1-100, ST-1-300, ST-2-100, ST-2-200, ST-2-300
Hinge (heavy weight) TA786 US26D MK
Exit Device (passage) (12) 8815 ETP US32D SA
Surface Closer (P/PRO)7500 M 689 NO
Kick Plate K1050 10" CSK BEV US32D RO
Door Stop RM861/RM855 US26D RO
Gasketing S44BL (rated openings only) PE
Set: 7.1 Doors: 209, 310, 311
Hinge TA714 US26D MK
Hinge TA714 QC US26D MK
Electrified Mortise Lock NAC-82271 LNP MK US26D SA
Surface Closer (P/PRO)7500 M 689 NO
Kick Plate K1050 10" CSK BEV US32D RO
Door Stop RM861/RM855 US26D RO
Gasketing S44BL (rated openings only) PE
Silencer 608-RKW (non-rated openings) RO
Frame Harness QC-C1500P MK
Door Harness QC-CX sized for hinge to locking hard-ware
MK
Wiring Diagram By Security Vendor OT
Position Switch DPS-M-BK SU
Notes: • Opening(s) normally closed and locked.
• Use of valid credential to unlock lever trim to allow entry.
• Lockset is fail-secure; will remain locked without power.
• Free egress always allowed from interior.
• Coordinate amperage for all openings and consolidate the number power supplies as able.
DCM Architecture & Engineering, LLC 080671 - 19
March 27, 2019
Set: 8.0 Doors: 309, 400, 401
6 Hinge TA714 US26D MK
2 Flush Bolt 555/557 US26D RO
1 Dust Proof Strike 570 US26D RO
1 Storeroom Lock 8204 LNP MK US26D SA
1 Surface Closer (P/PRO)7500 M 689 NO
2 Kick Plate K1050 10" CSK BEV US32D RO
2 Door Stop RM861/RM855 US26D RO
1 Astragal 18041CNB (rated openings only) PE
Set: 9.0
Doors: 207, 208, 218, 219, 308.2, 309, 312.2, 316, 317, 318, 319
3 Hinge TA714 US26D MK
1 Storeroom Lock 8204 LNP MK US26D SA
1 Kick Plate K1050 10" CSK BEV US32D RO
Set: 10.0 Doors: 102, 114
1 Surf Overhead Stop 10-X36 630 RF
Set: 11.0 Doors: 213.1, 214
1 Surf Overhead Stop 10-X36 630 RF
080671 - 20 DCM Architecture & Engineering, LLC
Set: 12.0 Doors: 311, 312, 313, 314, 315
1 Office Lock 8205 LNP MK US26D SA 1 Kick Plate K1050 10" 4BE CSK US32D RO 1 Wall Stop RM861 US26D RO
Set: 13.0 Doors: 210.1
1 Office Lock 8205 LNP MK US26D SA
Set: 14.0
Doors: 310.1308.3, 308.4, 317, 317.1
6 Hinge TA714 US26D MK
2 Flush Bolt 555/557 US26D RO
1 Dust Proof Strike 570 US26D RO
1 Classroom Lock 8237 LNP MK US26D SA
2 Surf Overhead Stop 10-X36 630 RF
2 Kick Plate K1050 10" CSK BEV US32D RO
Set: 15.0 Doors: 103, 111.1, 113, 211, 211.1, 211.2, 311.1, 311.2
1 Classroom Lock 8237 LNP MK US26D SA
DCM Architecture & Engineering, LLC 080671 - 21
March 27, 2019
Set: 16.0 Doors: 115
1 Surf Overhead Stop 10-X36 630 RF
Set: 17.0 Doors: 202.3, 202.4
1 Surface Closer (P/PRO)7500 M 689 NO
1 Kick Plate K1050 10" CSK BEV US32D RO
Set: 18.0
Doors: 104, 105, 106, 108, 111, 112, 116, 117, 204, 210, 212, 213, 215, 217, 301, 302, 303, 305, 314, 315, 308, 308.1, 312, 312.1, C302
1 Classroom Security Intruder Lock 8238 LNP MK US26D SA
1 Surface Closer (P/PRO)7500 M 689 NO
1 Kick Plate K1050 10" CSK BEV US32D RO
080671 - 22 DCM Architecture & Engineering, LLC
March 27, 2019
Set: 19.0 Doors: 109, 110, 205, 206, 306, 307
3 Hinge (heavy weight) TA786 US26D MK
1 Pull RM1210-24 US32D RO
1 Push Plate 82 US32D RO
1 Surface Closer (P/PRO)7500 M 689 NO
END OF SECTION 08 06 71