6_Material_Specifications_mvo.doc

DOC document 52 KB Posted

Attached to
HANNA DRAW FENCE CONVERSION Federal contract opportunity
Solicitation number
140L6221R0047
Issued by
Department of the Interior Bureau of Land Management Wyoming Region

View the file

Other files for this federal contract opportunity

Other files attached to HANNA DRAW FENCE CONVERSION, newest first.
File Type Posted
00_Bid_Schedule.xlsx XLSX spreadsheet
2_01009_general_mvo.docx DOCX document
Sol_140L6221R0047.pdf PDF
11_Seminoe_Overview_Map_10k.pdf PDF
10_Hanna_Draw_Overview_Map_24k.pdf PDF
9_Fence_Conversion_Drawings__Updated.pdf PDF
8__Work_Data_Sheet_2__4_wire_mvo.docx DOCX document
5__02827_fence_removal_mvo.docx DOCX document
3__01505__Mobilization_mvo.doc DOC document
1_SOW_mvo_KJP.docx DOCX document
7__Work_Data_Sheet_1_3_wire_mvo.docx DOCX document
4_02824_Wire_Fence_and_Gates_mvo.docx DOCX document
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Material Specifications

A. Barbed Wire: A strand of two 12‑1/2‑gauge galvanized wires twisted together with 2‑point barbs of 14‑gauge wire spaced 4-inches apart. Wire and barbs shall be zinc‑coated steel, with a zinc coating of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb‑force. The barbed wire shall conform to ASTM A 121.

B.

Barbless Wire: A strand of two 12‑1/2‑gauge galvanized wires twisted together. Wire shall be zinc‑coated steel wire of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb‑force. The barbless wire shall conform to ASTM A 121.

C.

Wood Stays: Straight, sound single-stem members. Shall be 42” long, 2” (milled) in diameter made from Ponderosa pine, or Lodgepole Pine. Peeled and CCA treated.

D.

Steel Fence Posts: ASTM A 702; painted green with white or silver tops "T" bar type, with a welded or riveted anchor plate. Furnish with clip‑type wire fasteners (punched tabs for fastening wires are not acceptable). Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall have a minimum weight of 1.33 lb/ft. The anchor plates shall weigh a minimum of 0.67 pounds +5 percent, be a minimum of 18 square inches in area, and be 18-inches from the bottom of the post. The posts shall be 5.5’ in length.

E.

Wood Posts and Braces:

1.

Acceptable Wood Posts: Sound single-stem members. A slight bend in one plane is acceptable. Posts may be full stem members, sawed members of square cross section, or split members (western red cedar only). Nominal diameter for treated posts shall be 6-inches. The following species will be acceptable: Ponderosa pine, Lodgepole pine, fir, and tamarack. All treated posts shall be free of bark with ends cut square.

2.

Basis for Rejection: Posts are not acceptable when sweep causes a straight line joining the center of the top to the center of the butt to fall outside the body of the post, or at point 2-inches or more from the center of the post. Posts that are charred, twisted, rotted, or excessively bent are not acceptable. Seasoning checks, single or opposite each other with a sum total equal to or more than 1/2 the thickness of the post are not acceptable.

3. Wood Treatment Practices: General: The following treatments may be used. Treatment method shall be in accordance with AWPA C 1.

1. Chromate Copper Arsenic Method: chromate copper arsenate, waterborne preservative (conforming to Type B in AWPA 5) shall be applied. Minimum net retention of solid preservative shall be 0.4 pounds per cubic foot (gauge only) using the full-cell pressure treatment process.

2. Assay Report: The Supplier shall furnish an assay report, for all treated wood products, from an independent testing laboratory to the Contracting Officer. A minimum of five inch boring shall be taken from each bundle of 50 posts as samples for the assay report.

A written submittal for all materials shall be submitted for approval to Megan Vasquez Ogle (mvasquezogle@blm.gov ) Rawlins Wyoming BLM Field Office prior to shipping the products. Contact Megan Vasquez Ogle with any questions 307-320-5713.

Hanna Draw Fence Conversion 2021

Material Specifications

File details come from the government source that posted it. Updated .