591_25087 Detroit Project Advertise.pdf
PDF 142 KB Posted
- Attached to
- 591/25087. MNB; DOSC - Electrical Project State and local contract opportunity
- Solicitation number
- RFQ 171 260000000252 2
- Issued by
- Wayne County, Detroit City, Michigan
About this file
This is a Project Advertisement form issued by the Michigan Department of Technology, Management and Budget, State Facilities Administration, Design & Construction Division for a construction project at the Detroit Operations & Service Center. The project involves removing, replacing, and adding new surge protection devices on electrical equipment throughout the facility, as well as updating and re-certifying the building's lightning protection system to current standards. The project is located at 1060 West Fort Street, Detroit, Michigan 48226. A mandatory pre-bid walk-through inspection and meeting is scheduled for Thursday, May 7, 2026, at 10:00 AM at the project location. Bid responses are due by May 27, 2026, at 2:00 p.m. Eastern time. All contractor and vendor representatives attending the pre-bid meeting must submit a Vendor/Contractor LEIN Request form five business days prior to the meeting. Questions from bidders must be submitted to Keith Martinez, PE, LC, LEED AP BD+C at kmartinez@abonmarche.com no later than 2:00 p.m. Eastern on Wednesday, May 20, 2026. Bid documents may be obtained from the SIGMA VSS portal at https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService.
Bid responses must include proof of State Project Registration from the Department of Labor and Economic Opportunity and must be uploaded to SIGMA VSS with a maximum of two attachments, each less than 25 MB. A 5% bid security is required. Bidders may submit qualified disabled veteran (QDV) information as a second attachment if applicable. The NIGP codes for this project are 91438 for Electrical (renovation) and 90903 for Administration of Contracts. Technical assistance with SIGMA VSS submissions is available through the SIGMA Help Desk at 517.284.0540, toll-free at 888.734.9749, or via email at sigma-procurement-helpdesk@michigan.gov. In cases of submission difficulties, bidders may contact the Design and Construction Contract Specialists Anne Watros or Don Klein for approval of email submissions, which must still be received prior to the 2:00 p.m. deadline to be considered responsive and responsible.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Service Disabled Veteran Owned Business Info Sheet 2025.pdf | ||
| 25087 Detroit Bid Set.pdf | ||
| 25087 Detroit Bid Specifications .pdf | ||
| Addendum # 1 591_25087 Detroit .pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0415 (R 3/25)
PROJECT ADVERTISEMENT
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE FACILITIES ADMINISTRATION
DESIGN & CONSTRUCTION DIVISION
This form is required for the advertisement of all construction projects. (1984 PA 431)
DTMB FILE NO.
591_25087_MNB
DATE
4/13/2026
ADVERTISEMENT DATE
4/13/2026
BID DUE DATE
5/27/2026 @ 2:00 p.m. EASTERN time
PROJECT NAME AND LOCATION (INCLUDE STREET ADDRESS)
Detroit Operations & Service Center Electrical Project ( MDOT) 1060 West Fort Street, Detroit MI 48226
WALK-THROUGH INSPECTION DATE, TIME, AND LOCATION
Thursday 5/7/2026 – Pre Bid Meeting at 10:00 AM
Location:
1060 West Fort Street, Detroit MI 48226
Mandatory Yes No
LEIN CHECK (Dept. of Corrections ONLY) All contractor/vendor representatives attending a Pre-Bid Walk Through Meeting must submit a Vendor/Contractor LEIN Request five business days prior to the meeting date, (See the attached Vendor/Contractor LEIN Request form). Send the LEIN Request form, filled out and signed, by email to Daniel T. Smith & Sharon Frost at email addresses: SmithD76@michigan.gov & FrostS1@michigan.gov .The email “Subject” must include (Facility Name, Project Name, Date & Time of Pre-Bid Walk Through Meeting).
NOTE: An individual is only permitted to represent one bidder at a mandatory walk-through.
DESCRIPTION OF WORK:
The scope of this project is to remove, replace, and add new surge protection devices on electrical equipment throughout the facility. Additionally, the building’s lightning protection system is to be updated, brought up to current standards, and re-certified.
Please NOTE:
• All bid responses require proof of State Project Registration from the Department of Labor and Economic Opportunity.
• Bid responses and bid attachments MUST be uploaded to SIGMA VSS.
• Contractors should only submit a maximum of two (2) attachments (both being less than 25 MB) for bid responses. One attachment is to be bid documents (Bid Summary, Bid Schedule, Bid Bond, Certification forms, Signature Authority, etc.) and if applicable, the other attachment should be Qualified Disabled Veteran (QDV) information (DD214, Proof of 51% Ownership and Proof of Service-Connected Disability) mailto:SmithD76@michigan.gov mailto:FrostS1@michigan.gov
• Do not wait until just before the 2:00 p.m. solicitation deadline to submit your bid response.
SIGMA VSS will not allow a proposal to be submitted after 2:00 p.m., even if a portion of the bid response has been uploaded.
• If you experience issues or have questions regarding your electronic submission, you must contact the SIGMA Help Desk for assistance prior to the 2:00 p.m., solicitation deadline. You may contact the SIGMA Help Desk by telephone at 517.284.0540 or toll-free at 888.734.9749. You may also email the SIGMA Help Desk at sigma-procurement-helpdesk@michigan.gov
• Please email the Design and Construction Contract Specialists if you are having SIGMA VSS issues. Please include your SIGMA ticket number and any supporting documentation (i.e., screenshots) to Anne Watros (WatrosA@michigan.gov) and Don Klein (KleinD4@michigan.gov).
• You may be asked by our contract specialists to email your bid response. Emailed submissions will require DCD approval and will be handled on a case-by-case basis.
• Approved emailed submissions MUST be received prior to 2:00 p.m. deadline to be considered responsive and responsible.
• Bid Responses should not be emailed to the Project Director.
5% BID SECURITY REQUIRED
NIGP CODES: 91438 Electrical (renovation), 90903 Administration of Contracts
ACCEPTING QUESTIONS UNTIL:
Please do not submit online questions via SIGMA VSS. ALL questions should be emailed to Keith Martinez, PE, LC, LEED® AP BD+C kmartinez@abonmarche.com no later than 2:00 p.m., Eastern on Wednesday 5/20/2026 .
Documents may be obtained from:
https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService
PSC
Abonmarche to Keith Martinez, PE
Address: 95 West Main Street Benton Harbor, MI 49022
C 248.318.6087 O 269.381.6170 Ext.684
Approved by:
mailto:sigma-procurement-helpdesk@michigan.gov mailto:WatrosA@michigan.gov mailto:KleinD4@michigan.gov mailto:kmartinez@abonmarche.com https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService
File details come from the government source that posted it. Updated .