T
T
EM
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
97 8654321
Location
Date Checked Drawn
Project Title
Office of Facilities
Management
Project Number
Building Number
Drawing Number
Dwg. of
Drawing Title
Approved: Project Director
ARCHITECT / ENGINEERS:CONSULTANTS:Date:Revisions:
GHN Project Number 21-511.00 564-21-407Pharmacy Chemo Hood Relocation
Veterans Affairs Medical Ctr
Fayetteville, AR300 S. Jefferson Avenue, Suite 301, Springfield, MO 65806
GHN ARCHITECTS ENGINEERS
T. 417-869-0719 F. 417-869-3044 o n e si xt e e n th in c h o n e fo o t
KEY PLAN NTS
Jun 8, 2021
1LDC DMF
CEILING AND FINISHES
REPAIR AND MODIFICATIONS
1-AI 101
Scale: 1/4" = 1'-0"
PARTIAL FLOOR PLAN
1-AI 101
Scale: 1/4" = 1'-0"
PARTIAL REFLECTED CEILING PLAN
1-AI 101
ARCHITECTURAL KEYED NOTES
REMOVE AND PROPERLY DISPOSE OF EXISTING 24”x24” CEILING
ACCESS DOOR. PREP OPENING FOR NEW CEILING ACCESS DOOR.
FURNISH AND INSTALL ONE NEW 304 STAINLESS STEEL
AIRTIGHT/WATERTIGHT CEILING ACCESS DOOR (ACUDOR
MODEL NUMBER ADWT-SS1616). ACCESS DOOR SHALL BE
INSTALLED WITH NORTH AND WEST SIDE OF FRAME MOUNTED
FLUSH WITH FACE OF NORTH AND WEST WALLS; WITH
CONTINUOUS EXPOSED STAINLESS STEEL PIANO HINGE ON
WEST SIDE.
REMOVE AND PROPERLY DISPOSE OF EXISTING 24”x24” CEILING
ACCESS DOOR. PREP OPENING FOR NEW CEILING ACCESS DOOR.
FURNISH AND INSTALL ONE NEW 304 STAINLESS STEEL
AIRTIGHT/WATERTIGHT CEILING ACCESS DOOR (ACUDOR
MODEL NUMBER ADWT-SS2424). ACCESS DOOR SHALL BE
INSTALLED WITH SOUTH SIDE OF FRAME MOUNTED FLUSH
WITH FACE OF SOUTH WALL; WITH CONTINUOUS EXPOSED
STAINLESS STEEL PIANO HINGE ON SOUTH SIDE.
RELOCATE ONE EXISTING (YELLOW) ¾” EMT CONDUIT AND
CONTROL WIRING ABOVE CEILING TO AVOID INTERFERENCE
WITH LOCATION OF NEW STAINLESS STEEL BSC EXHAUST DUCT.
PATCH/REPAIR DAMAGED CEILING TO MATCH ADJACENT
MATERIALS AND FINISHES.
PAINT CEILING COMPLETE (PREP, PRIME ONE COAT AND FINISH
PAINT TWO COATS ENTIRE CEILING). PAINT SHALL BE SHERWIN
WILLIAMS MACROPOXY 646, COLOR TO MATCH EXISTING.
REMOVE AND PROPERLY DISPOSE OF EXISTING 24”x24” CEILING
ACCESS DOOR. PREP OPENING FOR NEW CEILING ACCESS DOOR.
FURNISH AND INSTALL ONE NEW 304 STAINLESS STEEL
AIRTIGHT/WATERTIGHT CEILING ACCESS DOOR (ACUDOR
MODEL NUMBER ADWT-SS2424). ACCESS DOOR SHALL BE
INSTALLED WITH NORTH AND EAST SIDE OF FRAME MOUNTED
FLUSH WITH FACE OF NORTH AND EAST WALLS; WITH
CONTINUOUS EXPOSED STAINLESS STEEL PIANO HINGE ON
NORTH SIDE.
RELOCATE EXISTING PASS-THROUGH WITH VERTICAL
CENTERLINE 28” TO EAST WALL. MAINTAIN EXISTING
HORIZONTAL CENTERLINE 55-1/2” AFF. VERIFY EXACT LOCATION
WITH VHSO ENGINEERING. PATCH WALL TO MATCH EXISTING.
PATCH/REPAIR DAMAGED WALL TO MATCH ADJACENT
MATERIALS AND FINISHES (INCLUDING BUT NOT LIMITED TO
5/8” FIRE CODE DRYWALL, METAL STUDS AND TRACK).
PAINT WALL COMPLETE (PREP, PRIME ONE COAT AND FINISH
PAINT TWO COATS ENTIRE WALL). PAINT SHALL BE SHERWIN
WILLIAMS MACROPOXY 646, COLOR TO MATCH EXISTING.
REMOVE AND PROPERLY DISPOSE OF ONE EXISTING PASS
THROUGH AND STAINLESS-STEEL SIDE AND HEAD FRAME IN
29”x79-1/4” OPENING.
RELOCATE EXISTING EMERGENCY POWER RECEPTACLE AT
HORIZONTAL CENTERLINE 18” AFF, AND MAINTAIN EXISTING
VERTICAL CENTERLINE AT 15-1/2” TO WEST WALL.
FURNISH AND INSTALL ONE NEW CLEAN AIR PRODUCTS
PASS-THROUGH CABINET MODEL CAP18WFB-SST-18Wx18Hx18D
WITH HORIZONTAL CENTERLINE AT 55-1/2” AFF AND VERTICAL
CENTERLINE AT 42” TO WEST WALL.
PATCH AND REPAIR WELDED SEAM FLOORING AND INTEGRAL
COVE BASE. MATCH ADJACENT SURFACES AND FINISHES.
PROVIDE INFECTION CONTROL PRECAUTIONS/
CONTAINMENT SYSTEM AS REQUIRED (BY VHSO)
INFECTION CONTROL REPRESENTATIVE FOR ALL AREAS
OUTSIDE THE LIMIT OF WORK.
MAINTAIN EXIT AT ALL TIMES DURING CONSTRUCTION.
EXISTING DOORS/PARTITIONS TO REMAIN IN PLACE
DURING CONSTRUCTION TO SERVE AS A TEMPORARY
BARRIER.
IC1
IC2
IC3
EXISTING EXITS TO BE MAINTAINED DURING CONSTRUCTION.
PROVIDE TEMPORARY PROTECTION AS REQUIRED TO
MAINTAIN EGRESS AND SAFE PASSAGE FROM THE BUILDING.
PROVIDE HEPA EXHAUST FANS OPERATION TO KEEP SPACE
WITHIN THE PROJECT AREA UNDER NEGATIVE PRESSURE AS
LOCATIONS AND CONDITIONS DICTATE.
PROVIDE TEMPORARY PROTECTION WHILE WORKING IN THE
SPACES, BELOW OR ABOVE THE AREA OF DEMOLITION.
PROVIDE BARRIERS AND TEMPORARY PARTITIONS TO
PROTECT OCCUPANTS FROM PHYSICAL HAZARD AND NOISE
OF ALL DEMOLITION WORK AND FOR INFECTION CONTROL.
GENERAL I.C.R.A. NOTES
I.C.R.A. KEYNOTES
IC2
IC2
IC2
IC3
IC3
IC3
IC1
IC1
1.
2.
3.
4.
8 9
78 9
4 5
4 5
IC1
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text
CLEAN
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 1219-01
AutoCAD SHX Text
INTRAVENOUS
AutoCAD SHX Text
CLEAN ROOM
AutoCAD SHX Text 1224-01
AutoCAD SHX Text
ANTEROOM/
AutoCAD SHX Text
CLEAN STORAGE
AutoCAD SHX Text 1223-01
AutoCAD SHX Text
ONCOLOGY
AutoCAD SHX Text
CLEAN ROOM
AutoCAD SHX Text 1222-01
AutoCAD SHX Text
ANTEROOM/
AutoCAD SHX Text
CLEAN ROOM
AutoCAD SHX Text 1221-01
AutoCAD SHX Text
CHANGING
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 1220-01
AutoCAD SHX Text
CLEAN
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 1219-01
AutoCAD SHX Text
INTRAVENOUS
AutoCAD SHX Text
CLEAN ROOM
AutoCAD SHX Text 1224-01
AutoCAD SHX Text
97 SF
AutoCAD SHX Text
ANTEROOM/
AutoCAD SHX Text
CLEAN STORAGE
AutoCAD SHX Text 1223-01
AutoCAD SHX Text
61 SF
AutoCAD SHX Text
ONCOLOGY
AutoCAD SHX Text
CLEAN ROOM
AutoCAD SHX Text 1222-01
AutoCAD SHX Text
76 SF
AutoCAD SHX Text
ANTEROOM/
AutoCAD SHX Text
CLEAN ROOM
AutoCAD SHX Text 1221-01
AutoCAD SHX Text
61 SF
AutoCAD SHX Text
CHANGING
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 1220-01
AutoCAD SHX Text
51 SF
| Sheets and Views |
| 1-AI 101 |
| VP2 |
| VP3 |
| VP5 |
| VP6 |