Hanley-SSA-Addendum__2_20171030_(1).pdf

PDF 2 MB Posted

Attached to
Hanley SSA Barrier Wall Project Federal contract opportunity
Solicitation number
47PC1117B0004
Issued by
General Services Administration Public Buildings Service Region 2

About this file

Addendum 2

View the file

Other files for this federal contract opportunity

Other files attached to Hanley SSA Barrier Wall Project, newest first.
File Type Posted
SF1442_R1.pdf PDF
SF1442.pdf PDF
SF_24-98.pdf PDF
GSA527-15.pdf PDF
Questions_and_Answers.pdf PDF
C101_Small_Business_Set-Aside_GC_Agreement.docx DOCX document
Doc_Sec_Form.pdf PDF
Wage_Determination.pdf PDF
C301_GC_Reps_&_Certs.docx DOCX document
C201_Small_Business_Set_Aside_GC_Sol.docx DOCX document
Addendum_1_Specs_and_Drawings.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM NO. 2

Project: Social Security Administration Barrier Wall Project James M. Hanley Federal Building and Courthouse 10 South Clinton Street Syracuse, NY 13024

GSA Project: N0826200 [NKB#16320.06]

A/E Contract No.: GS-02P-10-PW-D-0013

Date of Issue: October 30, 2017

TO ALL BIDDERS: The following additions, deletions, and/or changes or clarifications to the drawings, specifications, and bidding documents for this project, shall become and are hereby made part of the Contract Documents.

They change the original documents only in the manner and to the extent stated. Each bidder shall acknowledge receipt of this ADDENDUM in the appropriate location on the bid proposal form.

This ADDENDUM consists of two (2) pages, including this page, plus twenty-five (25) pages of attachments. All requirements of the original Specifications and Drawings and previous Addendum, if applicable, shall remain in force except as noted by this ADDENDUM.

THE PURPOSE OF THIS ADDENDUM IS TO CHANGE THE

FOLLOWING ITEMS:

0.0 GENERAL

0.01 DELETE Addendum No. 1 Notes 2.27.4 and 2.27.5

0.02 REVISE Addendum No. 1 Note 2.27.7 as follows:

“Switch to be located on the pull side of Door #15 as noted on Drawing AE101 and shall control the lights in the interconnect corridor.”

0.02 REVISE Addendum No. 1 notes as follows:

a) Note 2.28.2 Refers to Drawing EY101

b) Note 2.28.3 Refers to Drawing EY101

c) Note 2.28.4 Refers to Drawing EY101

d) Note 2.28.5 Refers to Drawing EP101

1.0 SPECIFICATIONS

1.1 SECTION 00100 – TABLE OF CONTENTS: ADD new Specification Section 082110 –

THERMAL FUSED DOORS in the appropriate order listed.

1.2 SECTION 001100 – SUMMARY: ADD the attached 10-page inventory list to the end of this specification section. This inventory list is to be utilized by the Contractor for coordination with other vendors and for all other contract-required moving purposes.

1.3 SECTION 082110 – THERMAL FUSED DOORS: ADD the attached specification section to the project manual.

1.4 SECTION 238123 - AIR CONDITIONING UNITS: DELETE this specification in its entirety

2.0 DRAWINGS

2.1 Drawing G-003, PHASING PLAN: ADD new note to General Description of Phasing Work as follows:

“10. Temporary Construction Partition shall be similar to Wall Type 1 on Drawing A-002.”

2.1.1 ADD the attached drawing “AD-5 SWING SPACE EQUIPMENT”.

2.2 Drawing AD113, DEMOLITION PLAN – CORE: Note 8, ADD the following:

“Both display cases to be reinstalled as directed in the field by SSA / GSA.”

2.3 Drawing AE402, LARGE SCALE PLAN - CONSTRUCTION CORE: ADD the attached drawing

“AD-3 CORRIDOR SEPARATION WALL”

2.4 Drawing AE502, DETAILS: ADD the attached drawing “AD-4 CORRIDOR WALL DETAILS”

2.5 Drawing AE601, SCHEDULES: REVISE Door #11 to be “NEW” (not EXISTING) with PLAM1/PNT2 finish.

2.5.1 CHANGE Door #11 Finish from “EXISTING” to “PLAM1”

and Remarks from “E18” to “NEW”

2.5.2 CHANGE Door #12 Remarks from “E13” to “E18”

and Hardware Set from “8.0” to “5.0”.

2.5.3 CHANGE Door #20 Hardware Set from “12.0” to “11.0”

2.5.4 Door Schedule Remarks ADD new notes as follows:

“3. Doors #17 and #19 frames to be rated STC 50.

4. Doors #20 and #23 will remain “as is”. Doors and frames to be painted

- see Detail 5 on Drawing AE203.”

2.6 Drawing FD101 FOURTH FLOOR PLAN – FIRE PROTECTION REMOVALS: ADD the attached drawing “AD-F1”

2.7 Drawing FX101 FOURTH FLOOR PLAN – FIRE PROTECTION: ADD the attached drawing

“AD-F2”

2.8 Drawing MD101 FOURTH FLOOR PLAN – HVAC REMOVALS: ADD the attached drawing

“AD-H1”

2.9 Drawing ED101 FOURTH FLOOR PLAN – ELECTRICAL REMOVALS: ADD the attached drawing “AD-E1”

2.10 Drawing EL101 FOURTH FLOOR PLAN – LIGHTING: ADD the attached drawing “AD-E2”

SMITHGROUP DRAWINGS

2.11 Drawing Sheet E1, ELECTRICAL SYMBOLS, DETAILS AND DRAWING NOTES:

2.11.1 IWS/LAN CABLING NOTES – ADD the following notes:

“1. Contractor to provide additional cabling (CAT 6E) from the DCR room to a total of 14

Wireless Access Points (WAP and MON) as follows:

a. Four (4) WAP and one (1) MON on the 4th Floor North – 5 total access points.

b. Three (3) WAP and one (1) MON on the 4th Floor South – 4 total access points.

c. Two (2) WAP and one (1) MON on the 2nd Floor (Swing Space per Phasing Dwg) –

3 total access points.

d. One (1) WAP and one (1) MON on the 5th Floor (Swing Space per Phasing Dwg) –

2 total access points.

END OF ADDENDUM NO. 2

Syracuse SSA Inventory List

MISCELLANEOUS / IMPORTANT

Quantity Item Information Needed for Equipment/Person

ENTIRE OFFICE IS WINDOWED WITHOUT

CURTAINS TO BRIGHT AND GLARE ON ALL

COMPUTER SCREENS

53 Sets of curtains Curtains must be cleaned and reinstalled upon completion of phase These are from the North Tower

25 Sets of curtains Curtains must be cleaned and reinstalled upon completion of phase These are from South Tower

5 Sets of curtains Curtains must be cleaned and reinstalled upon completion of phase These are from the ADM office

6 Sets of curtains Curtains must be cleaned and reinstalled upon completion of phase These are from the Managers office

6 Tables for mail bins 30" l x 18" w x 26" h Will be disburse throughout office by SSA

4 Leather visitor chairs (2 per OS cube) 1 Per supervisor chair Seating chair will show placement

1 DVR equipment Remains in place in South Tower

Currently at guards desk in the South tower is the DVR equipment, it is a main part of Security System and cannot be touched until new security system is in place.

2ND FLOOR SWING SPACE

Quantity Item Information Needed for Equipment/Person

RELOCATED FROM 4TH FLOOR ‐ DM Office‐INTERIOR OFFICE ON

2ND FLOOR

3 2‐Drawer filing cabinets 2 2‐Shelf bookcases 36" l x 12.5" w x 30" h 6 Leather visitor chairs 1 Desk chair 1 Credenza w/ overhead storage 72" l x 30" w x 68.5" h 1 Desk 72" l x 36" w x 29.5" h 1 Office Safe

1 Scanner and camera equipment for HSPD‐12 cards EQUIPMENT SHOULD BE BOXED FOR STORAGE 1 Desktop local printer Relocated by Reliasource Electrical Needed

RELOCATED FROM 4TH FLOOR NORTH TOWER

60 Boxed employee items 3 Boxes per employee 20 Employee Chairs 1 per employee 1 Shredder Electrical Needed 15 Boxes of Paper 3 Secured Shred Bins 1 Coat rack 24" l x 18" w x 77" h 1 Recycle Bin

20 Articulating desk Relocated by Unicor/disposal by Unicor upon completion of project Electrical Needed

Furniture Panels Relocated by Unicor/disposal by Unicor upon completion of project 21 Docking Stations/Key Boards/Mice/Laptops Relocated by Reliasource Running on WIFI/Electrical Needed 3 Lexmark Printers Relocated by Reliasource Data Line Needed 1 Color printer Relocated by Reliasource Data Line Needed 1 Photocopier Stand Alone By SSA Vendor (Konica/Minolta) Electrical Needed

1 Photocopier w/fax & printer By SSA Vendor (Konica/Minolta) Data Line Needed/for fax capabilities must connect to phone board

4TH FLOOR SWING SPACE (EXISTING IVT ROOM)

1 Mail machine Data/Electric Needed 1 Table for mail machine 84" l x 30" w x 32" h 1 Mail Cart 1 Check printer Data/Electric Needed

2‐Drawer filing cabinets at check writing station (one with bar lock for checks and one for supplies)

1 60" Flat screen television attached on cart Move to breakroom

N/A IVT equipment Move to breakroom SSA is checking on wire length both TV and IVT are attached 1 Secure shredder Bin 15 Boxes of paper 1 Recycle Bin 18 Employee Boxes 3 per employee 6 Employee Chairs 1 Per employe 2 Standing mail stations holding employee mailboxes 60"l x 30" w x 78" h 2 Ladders To be moved to break room

1 Video phone and TTY for Hearing Impaired Employee See Seating Chart for Location Existing phone line must be extended to this location

1 Fax Machine (Primary w/ # 315‐479‐0063) PHONE LINE MAY NEED TO BE EXTENDED Existing phone line must be extended to this location 6 DOCKING STATIONS/MONITORS/LAPTOPS/KEYBOARDS/MICE RELOCATED BY RELIASOURCE‐ SSA VENDOR Using WI‐FI 1 LEXMARK PRINTER RELOCATED BY RELIASOURCE‐ SSA VENDOR Data Line Needed

6 ARTICULATING TABLES Relocated by Unicor/disposal by Unicor upon completion of project

FURNITURE PANELS Relocated by Unicor/disposal by Unicor upon completion of project

5TH FLOOR SWING SPACE (EXISTING IVT ROOM)

North Tower (5th Floor Training Room)

1 48" Flat screen television On a desk not to be relocated N/A IVT equipment Not to be relocated will be used during construction

1 Coat rack 48" l x 18" w x 77" h 1 Wall‐mounted mirror Pre‐existing remains in place 15 Boxes of Paper 1 Photocopier/Printer Data Line Needed for printing 1 Secure Shredder Bin 1 Recycle Bin 24 Employee Boxes 3 per employee 8 Employee chairs 1 per employee

8 DOCKING STATIONS/MONITORS/LAPTOPS/KEYBOARDS/MICE RELOCATED BY RELIASOURCE‐ SSA VENDOR Running on WI‐FI

8 ARTICULATING TABLES

Relocated by Unicor/disposal by Unicor upon completion of project

SECURE 5TH FLOOR STORAGE

9 5‐Drawer Administrative Filing Cabinets (including SS‐5 cabinet and cabinet for tape storage) These counts may change based on what office is able to purge prior to relocation and room size

This room must be connected to SSA Mega

Center

3 2‐Drawer Administrative Filing Cabinets (by safe/payroll sheets/by tape storage) Office is going to let us know what cabinets need to be in the front of the room for easy access Room can only be accessed by SSA

5‐Drawer Filing Cabinets ( 9 CDR, 2 EXR/T2 OP, 4 wages/DCNs, 5 for T2, 31 SSI, 4 spare across from BPE, 1 for Carrie) Possibility of additional secure storage room for PII if this room cannot accommodate our needs.

1 4‐Shelf bookcase holding Death Alerts 33"l x 13" w x 67.5" h 3 2‐Drawer Cabinets (for leads, breakfast cubicle supplies, and by CCM desk) 4 2‐Drawer UNION filing cabinets 1 5‐Drawer UNION filing cabinet

SOUTH TO NORTH TOWER

Visitor chairs (55 regular, 2 @ window 1, 2 behind guard and 6 in hall (55 for eventual disposal) These chairs will become disposal once beam seating is installed‐if beam seating isn't installed upon completion of North Tower they will be used temporarily

SOME OF THESE ARE CURRENTLY IN ELEVATOR/HALLWAY AREA AND CAN REMAIN OR BE

REINSTALLED AFTER PAINTING BUT ARE MANDATORY

1 Wall‐mounted security mirror ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER 1 Wall‐mounted SSA sign 93" l x 18.5" w ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER 2 Wall‐mounted pamphlet racks 29" l x 50" w ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER 6 Wall‐mounted display case 24" l x 36" w ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER 5 Wall‐mounted display case 48" l x 36" w ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER 1 Wall‐mounted display case 60" l x 36" w ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER 1 Wall‐mounted 36" round SSA emblem ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER

1 Wall clock ITEM MUST BE UN‐ANCHORED FROM SOUTH TOWER AND RE‐MOUNTED IN NOTH TOWER

LOCATION TO BE DETERMINED BY

MGMT.

6 Secured shred bins 21" l x 15" w x 36" h

LOCATION TO BE DETERMINED BY

MGMT.

1 VIP check‐in cabinet

Photo copiers from employee side of office (FEI copiers will stay in place‐‐2 w/ scanning capabilities and 1 faxing) THESE ARE RELOCATED BY SSA VENODR FROM SOUTH TOWER TO NORTH TOWER

Data Line Needed/for fax capabilities must connect to phone board ‐ this will be needed during North tower renovation also

4 Lexmark Printers and cabinet stands THESE ARE RELOCATED BY SSA VENODR FROM SOUTH TOWER TO NORTH TOWER Data line needed during North tower renoation also

2 SSTVs Disconnected by SSA Vendor/Reinstalled by SSA Vendor /wall mounts needed

Contractor must install the wall mounting brackets‐ SSA supplies mounts 25 Employee chairs for booths 1 per window on employee side 1 Desk 72" l x 36" w x 29.5" h Guard Desk 1 Desk chair Guard Chair 44 FEI Public Seating 2 Per Booth

4 Lexmark printers and cabinet stands 1 Desk printer

BASEMENT STORAGE

Quantity Item/Current Location Information Needed for Equipment/Person

North Tower (Employee side of office)

1 Administrative Form Rack 39.5" l x 11.5" w x 69" h 1 3‐Shelf bookcase holding administrative binders 33" l x 13" w x 46" h 5 Coat racks 48" l x 18" w x 77" h 2 OF THESE COAT RACKS RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 4 Coat rack (1 per OS cubicle) 2 OF THESE COAT RACKS RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 4 Leather visitor chairs (2 per OS cube) 6 Spare leather chairs for the OIG office and Carrie's cubicle 1 Evacuation chair RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 5 Wall clocks These will need to be anchored upon project completion Location will be determined by office management 3 Dry‐erase boards These will go to the training rooms upon project completion 1 Coat rack 1 Flag w/ stand

12 Form/pamphlet racks 40' l x 12" w x 69" h

RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT

AREA ‐ Location will be determined by office management

22 Shelves for supplies (toner/envelopes/tissues/etc…) 36" l x 12" w x 87" h These will go in stock room upon project completion Location will be determined by office management 4 Supply cabinets 36" l x 18" w x 72" h These will go in stock room upon project completion Location will be determined by office management 1 Utility cart 1 Credenza (holding medical supplies currently‐‐to go into DCR?) 60" l x 18" w x 29.5" h RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 1 VIP check‐in cabinet RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT

ADM Office 1 Coat rack RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 1 2‐shelf bookcases 36" l x 12.5" w x 30" h RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 5 Leather visitor chairs RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 1 Desk chair RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 1 Credenza w/ overhead storage 72" l x 30" w x 68.5" h RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT 1 Desk 72" l x 36" w x 29.5" h RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT

2 2‐Drawer filing cabinets UNLESS CONTAINS PII ‐ then must be stored

RETURN TO NORTH TOWER W/RENO COMPLETED IN THAT

AREA

1 Table for fax machine (currently UPS package table) 60" l x 24" w x 29" h 1 Table for sign‐in desk 60" l x 24" w x 29" h 2 Dollies 2 Wall clocks

South Tower (4th Floor Training Room) 4 Folding Tables 72" x 30" 3 Folding Tables 96" x 29.5" 5 Folding Tables 96" x 36"

South Tower (Public side of office‐‐FEI and reception windows)

1 Table next to copier (in PIR currently) 30" l x 18" w x 26" h 3 Folding tables at reception windows 72" l x 18" w 1 Folding table at reception window 60" l x 18" w 1 Wall‐mounted display case 48" l x 36" w 2 Wall clocks

BASEMENT STORAGE

South Tower (Public side of office‐‐PIR)

1 Coat rack 1 Floor display banner Returns to reception upon North tower completion 1 96" Bench seating

South Tower (Public side of office‐‐FEI and reception windows)

4 Secured shred bins 21" l x 15" w x 36" h

1 Filing cabinet 36" l x 18" w x 28.5" h These will be returned to office upon project completion

1 Bookcase (for envelope storage) 33" l x 13" w x 39" h These will be returned to stock rooms upon project completion

2 Form/pamphlet racks 40' l x 12" w x 69" h These will be returned to stock rooms upon project completion

4 Paper storage shelving units 14" l x 18" w x 29.5" h These will be returned to stock rooms upon project completion

3 Recycle and/or trash bins These will be returned to stock rooms upon project completion

South Tower (4th Floor Training Room) 1 Computer desk 42" l x 31"w x 33" h

1 Folding screen This will be returned to training room upon project completion

1 Supply cabinet on wheels 18" l x 19" w x 26" h This will be returned to training room upon project completion

1 Dry erase board on wheels 72" w x 78" h This will be returned to training room upon project completion

1 Flag w/ stand This will be returned to training room upon project completion

1 Table for HSPD‐12 equipment 30" l x 18" w x 26" h This will be returned to training room upon project completion

North Tower (5th Floor Training Room) This will be returned to training room upon project completion 1 Instructor desk 36" l x 32" w x 38" h

104 Training Room Chairs from both 4th and 5th floors This will be returned to training room upon project completion

1 Dry erase board on wheels 48" w x 72" h These are non‐stackable chairs These will be returned to 4th and 5th floor training room upon project completion

1 Podium This will be returned to training room upon project completion

3 Unassembed storage containers still in boxes 45" l x 21" w This will be returned to training room upon project completion

2 Supply cabinets 24" l x 25.5" w x 28" h These will be returned to stock rooms upon project completion

35 Boxes of paper These must be kept in front of room in case of need; all remaining to be brought to stock room upon project

DISPOSAL ITEMS

Quantity Item/Current Location Information Needed for Equipment/Person

1 Cabinet by Carrie's cubicle 2 Table and chairs by Carrie's cubicle 1 Current Desk holding the main office fax machine 1 Bookcase by the SSI fax/copier 1 Bookcase by Hal's old cubicle 1 Table holding the paper cutter 1 2‐Drawer filing cabinet holding the prisoner documentation 2 2 coat racks (by former TAS cubicle and admin pamplet rack) 1 Isabel's special chair 1 Table by FEI copier 3 9.5' x 30" Training room desks/work stations 3 75.5" x 30" Training room desks/work stations 3 5th Floor Training room bookselves 33" l x 13" w (54", 61" and 68" heights) 1 5th Floor Training room work table on wheels 4' x 3'

ADDITIONAL ITEMS FOR DISPOSAL

3 Tables 59.5" l x 29.5" w x 28.5" h 55 RECEPTION CHAIRS Upon beam seating installation 6 Wooden visitor chairs

1 Desk 72" l x 36" w x 29.5" h Remains in place until ADM office is completed

2 Desk matching filing cabinets 17" l x 24.5" w x 27.5" h Remains in place until ADM office is completed

Hanley Federal Bldg. Final Construction Documents SSA Barrier Walls Project 06/27/2017 GSA Project RNY N0826200

THERMAL FUSED FLUSH DOORS 08211-1

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice properly destroy or return documents when no longer needed

SECTION 08211 - THERMAL FUSED FLUSH DOORS

Part 1 - GENERAL

1.1 Related Documents

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

1.2 Summary

A. This Section includes the following:

1. Solid-core doors with Thermally Fused Laminate (herein referred to as “TFL”) faces.

2. Factory fitting flush wood doors to frames and factory machining for hardware.

3. Vision lite kits for flush wood doors.

B. Related Sections include the following:

1. Division 8 Section "Glazing" for glass view panels in flush wood doors.

1.3 Submittals

A. Product Data: For each type of door. Include details of core and edge construction and trim for openings.

B. Shop Drawings: Indicate location, size, and hand of each door; elevation of each kind of door;

construction details not covered in Product Data; and other pertinent data.

1. Indicate dimensions and locations of mortises and holes for hardware.

2. Indicate dimensions and locations of cutouts.

3. Indicate fire ratings for fire doors.

C. Samples for Initial Selection: Color samples consisting of actual faces in small sections for the following:

1. TFL Thermal Fused Door Faces: Show the full range of colors and woodgrains available.

D. Samples for Verification:

1. Hinge corner sections of TFL Thermal Fused doors, approximately 5 by 11 inches (127 by 279

mm) for each color or wood grain specified.

2. Frames for lite openings, 6 inches (150 mm) long, for each material, type, and finish required.

E. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified independent third party testing agency, for doors, showing compliance with specified performance requirements and physical properties.

1.4 Quality Assurance

A. Source Limitations: Obtain TFL Thermal Fused Flush Wood Doors through one source from a single manufacturer.

THERMAL FUSED FLUSH DOORS 08211-2

PROPERTY OF THE UNITED STATES GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice properly destroy or return documents when no longer needed

B. Quality Standard: Comply with WDMA I.S.1-A, 2004 edition "Industry Standard for Architectural Wood Flush Doors" and the following minimum values (for particle core doors):

1. NWWDA TM-7 Cycle Slam Test: 1,000,000 cycles.

2. NWWDA TM-8 Hinge Loading Test: 1,000 lbs.

3. NWWDA TM-10 Edge Screw Holding: Test 850 lbs.

4. NWWDA TM-10 Face Screw Holding: Test 650 lbs.

C. Fire-Rated Wood Doors: Doors complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to [UL 10C] [NFPA 252] [UBC Standard 7-2].

1. Test Pressure: After 5 minutes into the test, the neutral pressure level in furnace shall be established at 40 inches (1000 mm) or less above the sill – positive pressure.

2. Oversize, Fire-Rated Wood Doors: For door assemblies exceeding sizes of tested assemblies, provide manufacturer’s standard Construction Label, acceptable to authorities having jurisdiction, stating that doors comply with requirements of design, materials, and construction.

3. Temperature-Rise Rating: At exit enclosures, provide doors that have a temperature-rise rating of 250 deg F (121 deg C) maximum after 30 minutes of fire exposure. Doors with this temperature-rise rating are limited to 100 sq. inches of clear view area of glazing.

4. Blocking: When through-bolts are not to be used, indicate size and location of blocking in 45, 60 and 90-minute mineral core doors.

D. Security Rating for Particle Core Doors:

1. ASTM F 476, Grade 40.

E. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 1 Section "Project Management and Coordination."

1.5 Delivery, Storage, and Handling

1. Package doors to prevent damage in transit. Place doors on cardboard or wooden skids and wrap entire bundles of doors in plastic sheeting.

2. Mark each door on top rail with opening number used on Shop Drawings.

1.6 Project Conditions

1. Environmental Limitations: Do not deliver or install doors until building is enclosed, wet work is complete, and HVAC system is operating and will maintain temperature and relative humidity at occupancy levels during the remainder of the construction period.

2. Environmental Limitations: Do not deliver or install woodwork until building is enclosed, wet work is complete, and HVAC system is operating and maintaining temperature between 60 and 90 deg F (16 and 32 deg C) and relative humidity is between 25% and 55% during the remainder of the construction period.

1.7 Warranty

1. Special Warranty: Manufacturer's standard form, signed by manufacturer, Installer, and

Contractor, in which manufacturer agrees to repair or replace doors that are defective in materials or workmanship, have warped (bow, cup, or twist) more than 1/4 inch (6.4 mm) in a 48-by-84-inch (1219-by-2134-mm) section, or show telegraphing of core construction in face exceeding 0.01 inch in a 3-inch (0.25 mm in a 75-mm) span.

2. Warranty shall be in effect for the life of the installation.

THERMAL FUSED FLUSH DOORS 08211-3

PROPERTY OF THE UNITED STATES GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice properly destroy or return documents when no longer needed

Part 2 - PRODUCTS

2.1 Manufacturers

A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

B. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

C. TFL Thermal Fused Flush Wood Doors:

1. The Maiman Company; Springfield, MO

2. Acrovyn Vinyl clad flush door

3. Eggers InPro Vinyl clad Flush door

4. Or Approved equal

D. Metal Lite Kits for Doors:

1. All Metal Stamping

2.2 Door Construction, General

A. Adhesives: Do not use adhesives containing urea formaldehyde.

B. TFL Thermal Fused Wood Flush Doors:

1. TFL Thermal Fused Wood Flush Doors:

2. WDMA I.S. 1A Aesthetic Grade: Premium

3. TFL Thermal-Fused Faces: Decorative faces thermally fused to cores under heat and pressure, complying with Laminating Materials Association’s Product Standard and Typical Physical Properties of Decorative Overlays. LMA.2003.

4. Color or Woodgrain Pattern: As selected by Architect from manufacturer's full range of products.

5. Edgebanding: Impact-resistant polymer edging, minimum .040” thick, applied to all four edges after faces on particle core doors, and on 2 vertical edges on mineral core doors. Manufacturer's standard color that most closely matches faces.

6. Provide doors with pilot holes factory-drilled for vertical edge hinges and lock sets.

2.3 Solid-Core Doors

A. Particleboard Cores: Comply with the following requirements:

1. Particleboard: ANSI A208.1, Grade M-2.

2. Wood Stiles and Rails: Not required.

3. Blocking: Not required.

B. Mineral Core Fire-Rated Doors:

1. Construction: Construction and core specified above for type of face indicated or manufacturer's standard mineral-core construction as needed to provide fire rating indicated.

2. Blocking: For mineral-core doors, [use through bolts without composite blocking] [provide composite blocking with improved screw-holding capability approved for use in doors of fire ratings indicated as needed to eliminate through-bolting hardware, as follows:]

• 5-inch (125-mm) top-rail blocking for closer attachment.

• 5-inch (125-mm) bottom-rail blocking, in doors indicated to have protection plates or

THERMAL FUSED FLUSH DOORS 08211-4

PROPERTY OF THE UNITED STATES GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice properly destroy or return documents when no longer needed mortised automatic door bottoms.

• 5-inch (125-mm) midrail blocking, in doors indicated to have armor plates.

• [4-1/2-by-10-inch (114-by-250-mm) lock blocks] [5-inch (125-mm) midrail blocking], in doors indicated to have exit devices.

3. Edge Construction: At hinge stiles, provide manufacturer's standard laminated- edge construction with improved screw-holding capability and split resistance and with outer stile matching polymer edging.

4. Edge Construction: Provide edge construction with intumescent seals concealed by outer stile matching polymer edging, and laminated backing for improved screw-holding capability and split resistance.

5. Pairs: Provide meeting stiles with concealed intumescents, to eliminate the need for metal meeting edges and/or overlapping astragal.

2.4 Louvers and Lite Frames

A. Metal Frames for Lite Openings in Fire Doors: Manufacturer's standard frame formed of 0.0478-inch- (1.2-mm-) thick, cold-rolled steel sheet; factory primed and approved for use in doors of fire rating indicated.

2.5 Fabrication

A. Fabricate doors in sizes indicated for Project-site fitting.

B. Factory fit doors to suit frame-opening sizes indicated, with the following uniform clearances and bevels, unless otherwise indicated:

1. Comply with clearance requirements of referenced quality standard for fitting. Comply with requirements in NFPA 80 for fire-rated doors.

C. Factory machine doors for hardware that is not surface applied. Locate hardware to comply with

DHI-WDHS-3. Comply with final hardware schedules, door frame Shop Drawings, DHI A115-W series standards, and hardware templates.

1. Coordinate measurements of hardware mortises in metal frames to verify dimensions and alignment before factory machining.

D. Openings: Cut and trim openings through doors to comply with applicable requirements of referenced standards for kind(s) of door(s) required.

1. Light Openings: Trim openings with moldings of material and profile indicated.

Part 3 - Execution

3.1 Examination

A. Examine doors and installed door frames before hanging doors.

1. Verify that frames comply with indicated requirements for type, size, location, and swing characteristics and have been installed with level heads and plumb jambs.

2. Reject doors with defects.

THERMAL FUSED FLUSH DOORS 08211-5

PROPERTY OF THE UNITED STATES GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice properly destroy or return documents when no longer needed

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 Installation

A. Hardware: For installation, see Division 8 Section "Door Hardware."

B. Manufacturer's Written Instructions: Install doors, lite kits, and glazing to comply with manufacturer's written instructions, referenced quality standard, and as indicated.

1. Install fire-rated doors in corresponding fire-rated frames according to NFPA 80.

C. Factory-Fitted Doors: Align in frames for uniform clearance at each edge.

3.3 Adjusting

A. Operation: Rehang or replace doors that do not swing or operate freely.

End of Section 08211

EXISTING CEILING

& FIXTURES TO

REMAIN

REMOVE EXISTING

CEILING & FIXTURES

REMOVE EXISTING

DIFFUSER

REMOVE EXISTING

LIGHT FIXTURE

REMOVE EXISTING

LIGHT FIXTURE

EMERGENCY EXIT SIGN

2X2 LIGHT FIXTURE, TYP.

NEW 2X2 ACT CEILING

NEW CORRIDOR SEPARATION WALL

NEW AIR SUPPLY DIFFUSER

EMERGENCY EXIT SIGN

NEW BULK HEAD

NEW AIR SUPPLY DIFFUSER

412 SF

CORRIDOR

E23

4' - 11 7/8"

AD-4

AD-4

Sim

NKB

N. .______________________________________________________

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

1005 W. Fayette Street, Suite 4A Syracuse, NY 13204 Phone 315.428.1177 Fax 315.428.9822 www.nkbpc.com

SHEET OF

DESIGNED:

DRAWN:

CHECKED:

SCALE: 1/16" = 1' 0"

DATE:

DRAWING NO.

PROJECT

NUMBER:

CONSULTANTS:

Ram-Tech Engineers 6100 Fairway Drive Syracuse, NY 13211 Phone 315.463.7716 Fax 315.463.5578 www.ramtechengineers.com

H A

N L

E Y

S S

A B

A R

R I E

R W

A L

L

AD-3

16320.06

C O

R R

ID

O

R S

E P

A R

A T

IO

N

W A

L L

1/8" = 1'-0"AD-3

1 REFLECTED CEILING DEMOLITION PLAN - CORE.

1/8" = 1'-0"AD-3

2 REFLECTED CEILING CONSTRUCTION PLAN - CORE.

1/8" = 1'-0"AD-3

3 CONSTRUCTION PLAN - CORE.

BNV

Text Box

BNV

BNV

Text Box

BNV

BNV

Text Box

DBH

BNV

Text Box 10/30/17

BNV

Text Box

AD-3

BNV

Text Box

FIRESTOP JOINT COATING - SPRAY, TROWEL, OR

BRUSH APPLY THE COATING OVER THE FORMING

MATERIAL TO A NOMINAL 1/8" TO 3/16" THICK WET

COATING. OVERLAP THE COATING ONTO THE WALL

BY A MINIMUM 5/8"

MASONRY SCREWS @ 36" O.C.

EXISTING FLUTED CMU

3 5/8" METAL STUD

(2) 5/8" GWB, TYP

SEALANT BOTH SIDES FOR A SEAMLESS FINISH

CONCRETE FLOOR ASSEMBLY -

LIGHTWEIGHT OR

NORMALWEIGHT CONCRETE

POURED OVER FLUTED DECK

TO A MINIMUM CONCRETE

THICKNESS OF 2 1/2"

FORMING MATERIAL - FIRMLY

PACK MINIMUM 4PCF MINERAL

WOOL OR CERAMIC FIBER INTO

THE OPENING ABOVE THE

WALL TO THE DEPTH OF THE

WALL

GYPSUM WALLBOARD ASSEMBLY

- CONSTRUCTED WITH 5/8" TYPE-

X OR BETTER GYPSUM

WALLBOARD MOUNTED TO STEEL

STUDS WHERE A MAXIMUM JOINT

WIDTH BETWEEN THE TOP OF

WALL AND BOTTOM OF THE

RAISED FLUTE IS 3 5/8"

FIRESTOP JOINT COATING - SPRAY,

TROWEL, OR BRUSH APPLY THE

COATING OVER THE FORMING

MATERIAL TO A NOMINAL 1/8" TO

3/16" THICK WET COATING.

OVERLAP THE COATING ONTO THE

WALL BY A MINIMUM 5/8"

STEEL SLIP TRACKING

675 SF

ELEVATOR

LOBBY

EXISTING SPRINKLER

NEW BULKHEAD

NEW 2X2 CEILING GRID

WALL BEYOND

412 SF

CORRIDOR

EXISTING CEILING

EXISTING METAL

DECKING

AD-4

AD-4

SCHEDULED CEILING

25 GA CORROSION-PROTECTED

STEEL RUNNER, TOP & BOTTOM,

ANCHORED WITH PAF @ 36" O.C.

3 5/8" 16 GAUGE

CORROSIONPROTECTED

STEEL STUDS AT 16" O.C.

WITH HORIZONTAL BRACING AS

REQUIRED

(1) LAYER 5/8" GWB EACH

SIDE

EXISTING METAL DECK

EXISTING CEILING

NKB

N. .______________________________________________________

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

1005 W. Fayette Street, Suite 4A Syracuse, NY 13204 Phone 315.428.1177 Fax 315.428.9822 www.nkbpc.com

SHEET OF

DESIGNED:

DRAWN:

CHECKED:

SCALE: 1/16" = 1' 0"

DATE:

DRAWING NO.

PROJECT

NUMBER:

CONSULTANTS:

Ram-Tech Engineers 6100 Fairway Drive Syracuse, NY 13211 Phone 315.463.7716 Fax 315.463.5578 www.ramtechengineers.com

H A

N L

E Y

S S

A B

A R

R I E

R W

A L

L

AD-4

16320.06

C O

R R

ID

O

R W

A L

L D

E T

A

IL

S

1 1/2" = 1'-0"AD-3 AD-4

1 FLUTED CMU FIRESTOP DETAIL AT METAL STUD WALL

12" = 1'-0"AD-4

2 METAL DECK FIRE STOP DETAIL AT METAL STUD WALL

1/2" = 1'-0"AD-3 AD-4

3 CORRIDOR WALL

1" = 1'-0"AD-4 AD-4

4 BULK HEAD DETAIL

BNV

Text Box

BNV

BNV

Text Box

BNV

BNV

Text Box

DBH

BNV

Text Box 10/30/17

BNV

Text Box

AD-4

BNV

Text Box

REF. REF.

E

M P

L O

Y E

E S

P H

O T

O C

O P

IE

R

E X

IS

T

IN

G

P O

W E

R

D A

T A

E X

IS

T

IN

G

T V

IV

T

E Q

U

IP

M E

N T

D

E S

K S

O F

F

IC

E

L M

P R

IN

T

E R

E X

IS

T

IN

G

P O

W E

R

D A

T A

P R

IN

T

E R

- E X

IS

T

IN

G

P O

W E

R

D A

T A

L M

P R

IN

T

E R

C L R

P R

IN

T

E R

- E X

IS

T

IN

G

P O

W E

R

D A

T A

P C

- E

X

IS

T

IN

G

P O

W E

R

D A

T A

P C

- E

X

IS

T

IN

G

P O

W E

R

D A

T A

L M

P R

IN

T

E R

E X

IS

T

IN

G

P O

W E

R

D A

T A

E

M P

L O

Y E

E S

S S

A M

A

IL

E Q

U

IP

M E

N T

F A

X

L M

P R

IN

T

E R

E X

IS

T

IN

G

D A

T A

, P O

W E

R

E

X T

E N

D E

D

P H

O N

E L

IN

E

R E

L O

C A

T E

D

S S

A

IV

T

E Q

U

IP

M E

N T

V

ID

E O

P H

O N

E

T T

Y

- E

X T

E N

D E

D

P H

O N

E L

IN

E

D A

T A

A N

D

P O

W E

R

N K B

N

A R

C H

IT

E

C T

U R

E

E N

G

IN

E E

R

IN

G P

C

K B H A N D A R I

W

. F a y e tte

S tre e t, S u ite

A

S y ra c u s e , N

Y

P h o n e .4

.1

F a x

.4

.9 w w w .n k b p c .c o m

S H

E E

T O

F

S C

A L E

/1

' 0

D A

T E

D R

A W

IN

G

N O

P R

O J E

C T

N U

M B

E R

R a m

-T e c h

E n g in e e rs

F a irw a y D riv e

S y ra c u s e , N

Y

P h o n e .4

.7

F a x

.4

.5 w w w .ra m te c h e n g in e e rs

.c o m

H A

N L

E Y

S S

A B

A R

R

IE

R W

A L

L

A D

-5

0/30/17

.0

S W

IN

G

S P

A C

E E

Q U

IP

M

E N

T A

D -5

P H

A S

E

- 5

T H

F L

O O

R E

Q U

IP

M

E N

T

P H

A S

E

- 2

N D

F L

O O

R E

Q U

IP

M

E N

T

P H

A S

E

- 4

T H

F L

O O

R E

Q U

IP

M

E N

T

EXISTING CEILING

& FIXTURES TO

REMAIN

REMOVE EXISTING

CEILING &

FIXTURES

1005 W. Fayette Street, Suite 4A

Syracuse, NY 13204

Phone 315.428.1177

Fax 315.428.9822 www.nkbpc.com

REF. DWG. - ED101

SCALE: 1/8" = 1' 0"

DATE:

DRAWING NO.

PROJECT

NUMBER:

Ram-Tech Engineers

6100 Fairway Drive

Syracuse, NY 13211

Phone 315.463.7716

Fax 315.463.5578 www.ramtechengineers.com

NKB

N. .

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

HANLEY SSA BARRIER WALL

AD-E1

10/30/17

16320.06

PARTIAL FOURTH FLOOR PLAN - LIGHTING

REMOVALS

1/8" = 1'-0"

PARTIAL FOURTH FLOOR PLAN - LIGHTING REMOVALS

www. ramtechengineers.com

RAM-TECH

RAM-TECH Engineers

Syracuse, NY Buffalo, NY Philadelphia, PA

E N G I N E E R S phone: 315-463-7716 fax: 315-463-7758 of Syracuse, P.C.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

TELE.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEV. LOBBY

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

STAIR 2

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

MEN

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DBH

Callout Reinstall Exit Sign

7A 8A

EXISTING CEILING

& FIXTURES TO

REMAIN

REMOVE EXISTING

CEILING &

FIXTURES

1005 W. Fayette Street, Suite 4A

Syracuse, NY 13204

Phone 315.428.1177

Fax 315.428.9822 www.nkbpc.com

REF. DWG. - FD101

SCALE: 1/8" = 1' 0"

DATE:

DRAWING NO.

PROJECT

NUMBER:

Ram-Tech Engineers

6100 Fairway Drive

Syracuse, NY 13211

Phone 315.463.7716

Fax 315.463.5578 www.ramtechengineers.com

NKB

N. .

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

HANLEY SSA BARRIER WALL

AD-F1

10/30/17

16320.06

PARTIAL FOURTH FLOOR PLAN -

FIRE PROTECTION REMOVALS

1/8" = 1'-0"

PARTIAL FOURTH FLOOR PLAN - FIRE PROTECTION REMOVALS

www. ramtechengineers.com

RAM-TECH

RAM-TECH Engineers

Syracuse, NY Buffalo, NY Philadelphia, PA

E N G I N E E R S phone: 315-463-7716 fax: 315-463-7758 of Syracuse, P.C.

AutoCAD SHX Text

FREIGHT ELEV.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

TELE.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEV. LOBBY

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

STAIR 2

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

TS

AutoCAD SHX Text REMOVE SPRINLKER HEAD, MAINTAIN EXISTING 1" DROP FOR CONNECTION TO NEW SPRINKER HEAD (TYPICAL FOR 5)

SPRINKLER HEAD ETR (TYPICAL)

7A 8A

LOBBY

WOMENS TOILET

1005 W. Fayette Street, Suite 4A

Syracuse, NY 13204

Phone 315.428.1177

Fax 315.428.9822 www.nkbpc.com

REF. DWG. - FD101

SCALE: 1/8" = 1' 0"

DATE:

DRAWING NO.

PROJECT

NUMBER:

Ram-Tech Engineers

6100 Fairway Drive

Syracuse, NY 13211

Phone 315.463.7716

Fax 315.463.5578 www.ramtechengineers.com

NKB

N . .

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

HANLEY SSA BARRIER WALL

AD-F2

10/30/17

16320.06

PARTIAL FOURTH FLOOR PLAN -

FIRE PROTECTION

1/8" = 1'-0"

PARTIAL FOURTH FLOOR PLAN - FIRE PROTECTION

www. ramtechengineers.com

RAM-TECH

RAM-TECH Engineers

Syracuse, NY Buffalo, NY Philadelphia, PA

E N G I N E E R S phone: 315-463-7716 fax: 315-463-7758 of Syracuse, P.C.

AutoCAD SHX Text

FREIGHT ELEV.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

TELE.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEV. LOBBY

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

STAIR 2

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

VERT. PEN.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

FS

AutoCAD SHX Text

TS

AutoCAD SHX Text 1 "14"

AutoCAD SHX Text 1 "14"

AutoCAD SHX Text 1 "14"

AutoCAD SHX Text 1 "14"

AutoCAD SHX Text

REPLACE SPRINKLER HEAD, EXTEND TO NEW GRID. TYPICAL FOR 5

SPRINKLER HEAD ETR (TYPICAL)

ADDENDUM NO. 2