44 GHz signal analyzer PD.docx
DOCX document 35 KB Posted
- Attached to
- Signal Analyser
- Solicitation number
- W911N223Q0022
About this file
This document outlines specifications for a 44 GHz signal analyzer purchase by the Department of the Army Materiel Command Contracting Command Redstone Arsenal. The signal analyzer must meet detailed technical specifications including operating on 100-120V power, having a 10.6 inch multi-touch display, 160GB solid state storage, dimensions under 7.5x17x15 inches, frequency range from 10Hz to 44GHz, resolution bandwidth from 1Hz to 10MHz, input amplitude range from -30dBm to +30dBm, and conforming to various accuracy and dynamic range specifications. The unit requires an ANSI Z540-1-1994 calibration certificate and at least a one year warranty. It will operate standalone without any network or wireless connectivity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W911N223Q0022 Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SIGNAL ANALYZER
PURCHASE DESCRIPTION
1. GOVERNMENT NEEDS: A signal analyzer as described in this purchase description.
2. SPECIFICATIONS: The following specifications detail the basic characteristics of the signal analyzer:
2.1 GENERAL SPECIFICATONS
2.1.1. Power Requirements: Voltage and frequency 100 to 120 V, 50/60/400 Hz
2.1.2. Display
- Resolution: 1280 x 800 minimum, Capacitive multi-touch screen
- Size: 10.6 inch diagonal nominal
2.1.3. Data Storage: 160 GB nominal (removable solid state drive)
2.1.4. Dimensions (maximum); H: 7.5 inch x W: 17 inch x L: 15 inch
2.2 FREQUENCY AND TIME SPECIFICATIONS
2.2.1. Frequency Range: DC coupled: 10 Hz to 44 GHz; AC coupled: 10 MHz to 44 GHz
2.2.2. Aging Rate: ± 1 x 10–6 / year
2.2.3.: Temperature Stability:
| 20 to 30 °C | ± 2 x 10–6 | |
| Full Temperature Range | ± 2 x 10–6 |
2.2.4. Achievable Initial Calibration Accuracy: ± 1.4 x 10–6
2.2.5 Trigger: Free run, line, video, external 1, external 1, RF burst, periodic timer
2.2.6 Resolution Bandwidth
| Range (–3.01 dB bandwidth) |
| 1 Hz to 10 MHz (10 % steps), 4, 5, 6, 8, 10 MHz |
| Bandwidth Accuracy (power) |
| 1 Hz to 750 kHz |
| ± 1.0 % (± 0.044 dB) nominal |
| 820 kHz to 1.2 MHz (< 3.6 GHz CF) |
| ± 2.0 % (± 0.088 dB) nominal |
| 1.3 to 2.0 MHz (< 3.6 GHz CF) |
| ± 0.07 dB nominal |
| 2.2 to 3 MHz (< 3.6 GHz CF) |
| 0 to -0.2 dB nominal |
| 4 to 10 MHz (< 3.6 GHz CF) |
| 0 to -0.4 dB nominal |
2.2.7. Analysis Bandwidth: Maximum bandwidth – 85 MHz
2.2.8. Video Bandwidth Range - Same as Resolution Bandwidth range plus wide-open VBW (labeled 50 MHz)
2.3 AMPLITUDE ACCURACY AND RANGE SPECIFICATIONS
2.3.1. Amplitude Range – Preamp on/off – Displayed Average Noise Level to +30 dBm
2.3.2. Input Attenuator Range – 0 – 70 dB in 2 dB steps
2.3.3. Maximum Safe Input Level
| Average Total Power |
| +30 dBm (1 W) |
| Peak Pulse Power |
| +50 dBm (100 W) |
2.3.4. DC Volts: AC coupled - ± 100 Vdc; DC coupled - ± .2 Vdc
2.3.5 Frequency Response
Maximum error relative to reference condition (50 MHz)
| 20 to 30 °C |
| Full range |
| 95th percentile (≈ 2s) |
| 20 Hz to 10 MHz |
| ± 0.6 dB |
| ± 0.8 dB |
| ± 0.28 dB |
| 10 MHz to 50 MHz |
| ± 0.45 dB |
| ± 0.57 dB |
| ± 0.21 dB |
| 50MHz to 3.6 GHz |
| ± 0.45 dB |
| ± 0.70 dB |
| ± 0.20 dB |
| 3.6 to 5.2 GHz |
| ± 1.7 dB |
| ± 3.5 dB |
| ± 0.67 dB |
| 5.2 to 8.4 GHz |
| ± 1.5 dB |
| ± 2.7 dB |
| ± 0.47 dB |
| 8.4 to 13.6 GHz |
| ± 2.0 dB |
| ± 2.7 dB |
| ± 0.47 dB |
| 13.6 to 17.1 GHz |
| ± 2.0 dB |
| ± 2.7 dB |
| ± 0.52 dB |
| 17.1 to 22.0 GHz |
| ± 2.0 dB |
| ± 3.5 dB |
| ± 0.66 dB |
| 22.0 to 26.5 GHz |
| ± 2.5 dB |
| ± 3.7 dB |
| ± 0.79 dB |
| 26.5 to 34.5 GHz |
| ± 2.5 dB |
| ± 3.5 dB |
| ± 1.07 dB |
| 34.4 to 44 GHz |
| ± 3.2 dB |
| ± 4.9 dB |
| ± 1.4 dB |
2.4 DYNAMIC RANGE SPECIFICATIONS
2.4.1. Gain Compression
1 dB gain compression (two-tone)
| 20 to 500 MHz |
| +3 dBm (typical) |
| 500 MHz to 3.6 GHz |
| +5 dBm (typical) |
| 3.6 to 26.5 GHz |
| +4 dBm (typical) |
| 26.5 to 44 GHz |
| 0 dBm (nominal) |
2.4.2. Displayed average noise level (DANL) - Input terminated, sample or average detector, averaging type = Log, 0 dB input attenuation, IF Gain = High,
| 20 to 30 °C |
| Full range |
| Typical |
10 Hz
–95 dBm (nominal)
20 Hz
–105 dBm (nominal)
100 Hz
–110 dBm (nominal)
9 kHz to 1 MHz
–120 dBm (nominal)
1 MHz to 1.2 GHz
–135 dBm
| 1.2 to 2.1 GHz |
| –154 dBm |
| –152 dBm |
| –155 dBm |
| 2.1 to 3.6 GHz |
| –152 dBm |
| –151 dBm |
| –154 dBm |
| 3.6 to 4.2 GHz |
| –144 dBm |
| –142 dBm |
| –147 dBm |
| 4.2 to 6.6 GHz |
| –146 dBm |
| –144 dBm |
| –149 dBm |
| 6.6 to 8.4 GHz |
| –148 dBm |
| –146 dBm |
| –150 dBm |
| 8.4 to 13.6 GHz |
| –148 dBm |
| –146 dBm |
| –150 dBm |
| 13.6 to 20 GHz |
| –145 dBm |
| –143 dBm |
| –148 dBm |
| 20 to 26.5 GHz |
| –142 dBm |
| –140 dBm |
| –145 dBm |
| 26.5 to 34 GHz |
| –140 dBm |
| –138 dBm |
| –144 dBm |
| 34 to 40 GHz |
| –136 dBm |
| –133 dBm |
| –140 dBm |
| 40 to 44 GHz |
| –135 dBm |
| –132 dBm |
| –140 dBm |
2.5 INPUTS AND OUTPUTS
2.5.1 Front panel
RF input Connector: 2.4mm, 50 Ω (nominal)
2.5.2 Rear Panel
10 MHz out Connector Output amplitude Frequency
BNC female, 50 Ω (nominal) ≥ 0 dBm (nominal) 10 MHz ± (10 MHz x frequency reference accuracy)
Ext Ref In Connector Input amplitude range Input frequency Frequency lock range
BNC female, 50 Ω (nominal) –5 to 10 dBm (nominal) 1 to 50 MHz (nominal) ± 2 x 10–6 of ideal external reference input frequency
Trigger 1 / 2 inputs
Impedance Trigger level range
BNC female 10 kΩ nominal –5 to +5 V
Trigger 1 / 2 outputs
Impedance Level
BNC female 50 Ω nominal 0 to 5 V (CMOS)
USB ports compatible with USB 3.0
2.6 I/Q ANALYZER
2.6.1. Frequency span – 10 Hz to 85 MHz
2.6.2 Resolution Bandwidth
Range
| Overall |
| 100 mHz to 3 MHz |
| Span = 1 MHz |
| 50 Hz to 1 MHz |
| Span = 10 kHz |
| 1 Hz to 10 kHz |
| Span = 100 Hz |
| 100 mHz to 100 Hz |
2.6.3 Data acquisition (standard 10 MHz IF path)
| Time record length (minimum) |
| 4,000,000 IQ sample pairs |
| Sample rate (minimum) |
| 100 MSa/s |
| ADC resolution (minimum) |
| 12 Bits |
2.7 Preamplifier
2.7.1 Gain
| 100 kHz to 3.6 GHz |
| +20 dB (nominal) |
| 3.6 to 26.5 GHz |
| +35 dB (nominal) |
| 26.5 to 44 GHz |
| +40 dB (nominal) |
2.7.2 Noise Figure
| 100 kHz to 3.6 GHz |
| 11 dB (nominal) |
| 3.6 to 8.4 GHz |
| 9 dB (nominal) |
| 8.4 to 26.5 GHz |
| 10 dB (nominal) |
| 26.5 to 44 GHz |
| DANL + 176.24 dB (nominal) |
3. CALIBRATION - An ANSI Z540-1-1994 calibration/certificate shall be provided with the unit.
4. INFORMATION ASSURANCE REQUIREMENTS: This system will operate in stand-alone mode only (no network connection of any kind). If there becomes such a time where this system requires the use of another PC (laptop, tablet, etc.) or network connection it will conform to all requisite DoD and Army cybersecurity requirements. Additionally, since this system operates in stand-alone mode there will be no ability to connect via either wireless (e.g Bluetooth) or wired (e.g. Ethernet cable), to a network. If these parameters change then the system will be subject to Change Configuration Board (CCB) approval for operation.
5. WARRANTY: A one year minimum warranty shall be furnished with the provided equipment. The warranty shall cover all components. The warranty period begins when the LEAD Contracting Officer provides official confirmation that the equipment has satisfied all operational provisions of the contract.
6. PRESERVATION, PACKAGING AND DELIVERY: The contractor shall utilize standard commercial methods for preservation and packaging appropriate for the provided equipment and acceptable to commercial carriers. As a minimum, all areas susceptible to damage from exposure to the elements shall be preserved and/or packed to prevent damage. The contractor shall be responsible for ensuring the equipment is delivered to LEAD in good condition.
7. INSPECTION AND ACCEPTANCE: The provided equipment shall be examined for design, construction, materials, components, and workmanship to determine compliance with the contract and this specification. Any deviation from these requirements shall be cause for rejection.
File details come from the government source that posted it. Updated .