PR_40225943_Questions_and_Answers.pdf

PDF 43 KB Posted

Attached to
GWMP Building Improvement Federal contract opportunity
Solicitation number
40225943
Issued by
Department of the Interior National Park Service

About this file

Questions and Answers.

View the file

Other files for this federal contract opportunity

Other files attached to GWMP Building Improvement, newest first.
File Type Posted
SpecsSpaceManagment_-_Revised_-_9-10-15.pdf PDF
PR_40225943_Questions_and_Answers_-_Revised.pdf PDF
Drawings_(2).pdf PDF
Space_Improvement_Clauses.docx DOCX document
Bid_Sheet.xlsx XLSX spreadsheet
DB_Wages_Building_Construction_Fairfax_County_8-24-2015.pdf PDF
SpecsSpaceManagment.pdf PDF
SF1442.pdf PDF
Section_L_-_Instructions_to_Offerors _Section_M_-_Evaluation_of_Offers.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PR 40225943 – Space Improvement

Questions and Answers

1. Are we required to pull permits for any scope of the work included in these drawings and specs? - I am guessing this is yes, but unsure what permits are required given that it is federal land.

a. No permits required.

2. Please confirm that everything will be removed from the building.

a. CONFIRMED. Specification is correct.

3. Please advise if workers will continue to use any part of the building during construction.

a. No workers will be present. Specification is correct.

4. Please confirm three coats of paint.

a. CONFIRMED. Specification is correct.

5. Please confirm that title is to be put in the room immediately in the main door. The floor is not level and the life of this tile is not likely to be long if the floor is not leveled out.

a. No change to the specification is anticipated before award.

6. Please confirm re-use of hardware from doors.

a. CONFIRMED. Specification is correct.

7. Please confirm that roof repairs are not included. If the roof has leaks and the ceiling tiles are replaced, they are likely to be water damaged again.

a. Confirmed, roof repairs are not included. Specification is correct.

8. When matching existing windows, if the old windows are wood will they need to be replaced with wood windows?

a. Yes. Section 08550 of specification is correct.

9. The site visit mentioned that it is possible to stage at the end of the building where the smaller concrete pad is.

Can you confirm this does not conflict with Paragraph 1.4 A of the Specifications Section 01010-1?

a. CONFIRMED, NO CONFLICT.