36C77018R9601-005.pdf
PDF 24 MB Posted
- Attached to
- Construction of Mezzanine Federal contract opportunity
- Solicitation number
- 36C77018R9601
About this file
36C77018R9601 P01 - Drawings (2018 8 9) VA Tucson CMOP Storage Mezzanine_drawings (PRC-001).pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C77019C0002-000.docx | DOCX document | |
| 36C77018R9601-0003000.docx | DOCX document | |
| 36C77018R9601-0003010.pdf | ||
| 36C77018R9601-0003009.pdf | ||
| 36C77018R9601-0003006.pdf | ||
| 36C77018R9601-0003002.pdf | ||
| 36C77018R9601-0003004.pdf | ||
| 36C77018R9601-0003007.pdf | ||
| 36C77018R9601-0003008.pdf | ||
| 36C77018R9601-0003001.pdf | ||
| 36C77018R9601-0003005.pdf | ||
| 36C77018R9601-0003003.pdf | ||
| 36C77018R9601-0002002.pdf | ||
| 36C77018R9601-0002001.pdf | ||
| 36C77018R9601-0002000.docx | DOCX document | |
| 36C77018R9601-0001000.docx | DOCX document | |
| 36C77018R9601-004.docx | DOCX document | |
| 36C77018R9601-006.pdf | ||
| 36C77018R9601-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DESCRIPTION
DRAWING INDEX
LOCATION MAP
GENERAL NOTES
· CONSTRUCTION OF A MEZZANINE AT CAGE AREA.
· INSTALLATION OF NEW DUCTWORK AT CAGE AREA.
· INSTALLATION OF NEW HVAC UNIT EXTERIOR OF NORTH WALL.
· MODIFICATIONS TO EXISTING LIGHTING AT CAGE AREA.
· INSTALLATION OF A VERTICAL RECIPROCATING CONVEYOR
(MATERIAL LIFT)
BRITANNIA DR.
ROADVALENCIA
PA
LO
V
ER
D E
HEMISPHERE LOOP
A
LV
ER
N
O N
W A
Y
SITE
PROJECT
GENERAL
GI001 COVER SHEET
ARCHITECTURE
AG001 ARCHITECTURAL ABBREVIATIONS, SYMBOLS, ANNOTATIONS,
AND GENERAL NOTES
AG111 CODE COMPLIANCE - LIFE SAFETY
AL111 FLOOR & MEZZANINE PLANS
AB211 BUILDING ELEVATIONS-INTERIOR
STRUCTURAL
S001 STANDARD STRUCTURAL NOTES
S101 FOUNDATION PLAN - NEW MEZZANINE
S201 FOUNDATION DETAILS
S301 FRAMING PLAN - MEZZANINE
S401 FRAMING DETAILS
MECHANICAL
M001 MECHANICAL SPECIFICATIONS
M002 MECHANICAL SYMBOLS LEGEND
MD111 MECHANICAL DEMOLITION FLOOR PLAN
MH111 MECHANICAL HVAC NEW WORK FLOOR PLAN
MH112 MECHANICAL HVAC NEW WORK MEZZANINE PLAN
MH301 MECHANICAL SECTION VIEW
M501 MECHANICAL SCHEDULES AND SEQUENCE OF OPERATION
M502 MECHANICAL DETAILS
ELECTRICAL
E-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
ED111 FIRST FLOOR ELECTRICAL DEMOLITION PLAN
E-111 FIRST FLOOR ELECTRICAL LIGHTING PLAN
E-121 MEZZANINE ELECTRICAL LIGHTING PLAN
E-701 ELECTRICAL SCHEDULES, CALCULATIONS, AND DETAILS
FIRE PROTECTION
FP111 FIRE PROTECTION EXISTING FLOOR PLAN
FP112 FIRE PROTECTION EXISTING FLOOR PLAN
FP113 FIRE PROTECTION NEW WORK FLOOR PLAN
1. VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE JOB
BEFORE PROCEEDING WITH THE WORK. DISCREPANCIES (IF ANY.) ARE
TO BE REFERRED TO THE COTR FOR SETTLEMENT.
2. IN GENERAL, THE PLAN DIMENSIONS SHOWN ARE:
2.1. TO THE FACE OF STUD AT STUD PARTITIONS AND FURRING
2.2. TO THE FACE OF CONCRETE, AND CONCRETE WALLS.
2.3. TO THE COLUMN GRID LINES.
3. DO NOT SCALE THE DRAWINGS.
4. THE CONTRACTOR SHALL COORDINATE ALL TRADES FOR ALL OPENINGS
THROUGH NEW OR EXISTING CONSTRUCTION FOR DUCTS, PIPES,
CONDUITS, CABINETS, AND EQUIPMENT. VERIFY SIZES, AND LOCATIONS.
5. USE APPROVED FIRE STOP SLEEVES, AND SEALANTS WHERE PIPES,
DUCTS, CONDUITS, OR OTHER SYSTEMS PENETRATE FIRE OR
SMOKE-RESISTIVE WALLS.
6. PACK MINERAL FIBER INSULATION AROUND PIPES, CONDUITS, DUCTS,
OR OTHER EQUIPMENT THAT PENETRATE NON-RATED PARTITIONS
7. VERIFY ALL ROUGH-IN DIMENSIONS, AND SERVICE CONNECTION
REQUIREMENTS FOR OWNER-FURNISHED EQUIPMENT, AND EQUIPMENT
INCLUDED IN THIS CONTRACT.
8. DO NOT COMMENCE WORK UNTIL OWNER HAS REMOVED EXISTING
FURNISHINGS, APPLIANCES, EQUIPMENT, COMPUTERS, MONITORS AND
DEMOUNTABLE OR MOVABLE DEVICES, SHELVES, SUPPLIES, ETC AND
HAS PROVIDED THE CONTRACTOR WITH WRITTEN NOTICE TO PROCEED.
9. PROTECT ALL ADJACENT SURFACES AND OWNER EQUIPMENT INSIDE
AND ADJACENT TO WORK AREA FROM DAMAGE NOT INDICATED AS
BEING REMOVED. DAMAGED SURFACES SHALL BE REPAIRED, AT NO
ADDITIONAL COST, TO THEIR ORIGINAL CONDITION OR PREPPED FOR
NEW FINISH WORK AS DENOTED.
10. CONTRACTOR SHALL ERECT AND MAINTAIN SAFETY: BARRIERS,
WARNING DEVICES, ENTRY PORTALS, ETC., AS NECESSARY TO
PROTECT OWNER EMPLOYEES AND THE PUBLIC DURING ALL
CONSTRUCTION ACTIVITIES.
11. WORK ACTIVITIES SHALL BE CONDUCTED IN SUCH A MANNER AS TO
MAINTAIN OPERATIONAL STATUS OF THE FACILITY, WHICH WILL
CONTINUE TO OPERATE DURING CONSTRUCTION OUTSIDE THE
WORKING HOURS NOTED ABOVE. THE CONTRACTOR SHALL ERECT
NECESSARY ENCLOSURES TO PROTECT OWNER EQUIPMENT AND
MATERIALS FROM DAMAGE DUE TO CONTRACTOR'S WORK ACTIVITIES,
DIRT, DUST, WATER, FIRE, THEFT OR VANDALISM. COORDINATE WITH
OWNER'S ONSITE SAFETY OFFICER FOR ALL REQUIREMENTS.
12. DEMOLITION OR ERECTION ACTIVITIES WHICH ARE DEEMED BY THE
CONTRACTOR TO BE TO HAZARDOUS TO MAINTAIN BUSINESS
OPERATIONS OR ACCESS BY THE PUBLIC OR SHALL INTERRUPT THE
AVAILABILITY OF UTILITY SERVICE SHALL REQUIRE THE CONTRACTOR
TO NOTIFY THE OWNER AND BUSINESSES AFFECTED BY THIS WORK OF
THE NEED FOR TEMPORARY CLOSURE AND SHALL PROVIDE A
SCHEDULE INDICATING THE DATES CLOSURE WILL BE NECESSARY AND
THE TYPE OF ACTIVITY THAT WILL BE OCCURRING DURING THAT
PERIOD.
13. THE ARCHITECT SHALL BE NOTIFIED OF ANY EXISTING BEARING WALL,
FOUNDATION COMPONENT, STRUCTURAL MEMBER, ANCHORING
CONDITION OR REUSED STRUCTURAL CONNECTION WHICH HAS BEEN
COMPROMISED BY FIRE, WATER, MOLD, DEMOLITION ACTIVITIES OR AGE
OR WHICH APPEARS TO BE SUBSTANDARD WITH RESPECT TO THE
STANDARDS DEFINED BY CURRENT CODE PRACTICES OF
CONSTRUCTION, FOR ASSESSMENT, PRIOR TO FURTHER WORK BEING
CONDUCTED IN THE SUSPECT AREA.
14. SURFACES DAMAGED BY DEMOLITION OR OPENINGS RESULTING FROM
REMOVED WALLS, DOORS, FIXTURES EQUIPMENT, CEILINGS, ETC. SHALL
BE REPAIRED SUCH THAT THE INTERIOR AND EXTERIOR SURFACES
MATCH THE SURROUNDING MATERIAL, TEXTURE, FINISH AND COLOR.
THE FINISHED SURFACE SHALL NOT BE DISTINGUISHABLE FROM THE
SURROUNDING SURFACE.
15. FIRE PROTECTED SURFACES DAMAGED BY DEMOLITION OR NEW
CONSTRUCTION ATTACHMENTS SHALL BE REFINISHED WITH LIKE
MATERIALS TO THE DEPTHS AND ASSEMBLIES OF THE SURROUNDING
FIRE PROTECTION SYSTEM.
TUCSON CONSOLIDATED MAIL OUTPATIENT PHARMACY
STORAGE MEZZANINE
3675 EAST BRITANNIA DRIVE
TUCSON, ARIZONA 85706
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GLHN Architects & Engineers, Inc.
2939 E. Broadway Blvd.
Tucson, AZ, 85716
(520) 881-4546 Ted Moeller
Engineering Discipline:
Turner Structural Engineering Company 3026 N. Country Club Tucson, AZ, 85716
(520) 323-3422 Jim Hart
Tucson CMOP Storage Mezzanine
3675 E. Brittania Dr. Tucson, AZ
762-18-01
Project Director
June 14, 2018Revisions: Date: GLHN Project No. 17073.00 MLH PMF
GI001
COVER SHEET
1. THE VA CMOP IS A MAIL OUTPATIENT PHARMACY FACILITY LOCATED AT
(ADDRESS). THEY PROVIDE SERVICES TO THE VA COMMUNITY IN
TUCSON AND THE SOUTHWEST REGION OF THE UNITED STATES
2. THE CURRENT FACILITY WORK HOURS ARE FROM 6 AM TO 12 PM
MONDAY THRU FRIDAY IN TWO SHIFTS. THE CONTRACTOR WILL HAVE
ACCESS TO THE AREA OF WORK IN THE FACILITY 24 HOURS A DAY,
SEVEN DAYS A WEEK AS COORDINATED WITH THE USERS. ALL
SIGNIFICANT VIBRATION INTENSIVE OR NOISY WORK SHALL OCCUR
OFF HOURS.
3. PHASING REQUIREMENTS: CONTRACTOR SHALL BE REQUIRED TO
PROVIDE A PHASING SCHEDULE TO DEPICT WHICH AREAS WORK WILL
BE PERFORMED AND THE DURATION OF EACH PHASE.
4. EXISTING EQUIPMENT: THERE IS AN EXISTING FREEZER IN THE AREA
OF WORK THAT WILL BE NEED CONTINUOUS ACCESS DURING
WORKING HOURS FOR THE DURATION OF THE PROJECT. THE
EXISTING AUTOMATION EQUIPMENT WITHIN THE CAGED AREA WILL BE
SHUT DOWN AND REMAIN IN PLACE DURING THE CONSTRUCTION.
OWNER WILL WRAP AND SEAL THIS EQUIPMENT PRIOR TO
CONTRACTOR COMMENCING WORK. CONTRACTOR SHALL PROTECT
EQUIPMENT FORM DAMAGE FOR THE DURATION OF THE PROJECT.
5. SUMMARY WORK INCLUDED: DEMOLITION AND REMOVAL OF
SELECTED PORTIONS OF BUILDING OR STRUCTURE. DEMOLITION AND
REMOVAL OF SELECTED SITE ELEMENTS. SALVAGE OF EXISTING ITEMS
TO BE REUSED OR RECYCLED.
6. MATERIALS OWNERSHIP: UNLESS OTHERWISE INDICATED, DEMOLITION
WASTE BECOMES PROPERTY OF CONTRACTOR. HISTORIC ITEMS,
RELICS, ANTIQUES, AND SIMILAR OBJECTS INCLUDING, BUT NOT
LIMITED TO, CORNERSTONES AND THEIR CONTENTS,
COMMEMORATIVE PLAQUES AND TABLETS, AND OTHER ITEMS OF
INTEREST OR VALUE TO OWNER THAT MAY BE UNCOVERED DURING
DEMOLITION REMAIN THE PROPERTY OF OWNER. CAREFULLY
SALVAGE IN A MANNER TO PREVENT DAMAGE AND PROMPTLY RETURN
TO OWNER.
7. PREDEMOLITION CONFERENCE: CONDUCT CONFERENCE AT PROJECT
SITE.
8. SUBMITTALS: SUBMIT ENGINEERING SURVEY OF CONDITION OF
BUILDING. PROVIDE PROPOSED PROTECTION MEASURES: SUBMIT
REPORT, INCLUDING DRAWINGS, THAT INDICATES THE MEASURES
PROPOSED FOR PROTECTING INDIVIDUALS AND PROPERTY, FOR DUST
CONTROL AND FOR NOISE CONTROL. INDICATE PROPOSED LOCATIONS
AND CONSTRUCTION OF BARRIERS. SCHEDULE OF SELECTIVE
DEMOLITION ACTIVITIES WITH STARTING AND ENDING DATES FOR
EACH ACTIVITY. PREDEMOLITION PHOTOGRAPHS OR VIDEO.
9. CLOSEOUT SUBMITTALS: INVENTORY OF ITEMS THAT HAVE BEEN
REMOVED AND SALVAGED.
10. FIELD CONDITIONS: OWNER WILL OCCUPY PORTIONS OF BUILDING
IMMEDIATELY ADJACENT TO SELECTIVE DEMOLITION AREA. CONDUCT
SELECTIVE DEMOLITION SO OWNER'S OPERATIONS WILL NOT BE
DISRUPTED. CONDITIONS EXISTING AT TIME OF INSPECTION FOR
BIDDING PURPOSE WILL BE MAINTAINED BY OWNER AS FAR AS
PRACTICAL. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN
EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH
SELECTIVE DEMOLITION. HAZARDOUS MATERIALS: IT IS NOT EXPECTED
THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK.
STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE IS NOT
PERMITTED. IF SUSPECTED HAZARDOUS MATERIALS ARE
ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECT
AND OWNER. HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER
UNDER A SEPARATE CONTRACT. MAINTAIN FIRE-PROTECTION
FACILITIES IN SERVICE DURING SELECTIVE DEMOLITION OPERATIONS.
11. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN
IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE
DEMOLITION OPERATIONS. ARRANGE SELECTIVE DEMOLITION
SCHEDULE SO AS NOT TO INTERFERE WITH OWNER'S OPERATIONS.
12. WARRANTY: EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND
REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING
SELECTIVE DEMOLITION, BY METHODS AND WITH MATERIALS AND
USING APPROVED CONTRACTORS SO AS NOT TO VOID EXISTING
WARRANTIES.
13. PERFORMANCE REQUIREMENTS: REGULATORY REQUIREMENTS:
COMPLY WITH GOVERNING EPA NOTIFICATION REGULATIONS BEFORE
BEGINNING SELECTIVE DEMOLITION. COMPLY WITH HAULING AND
DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
STANDARDS: COMPLY WITH ASSE A10.6 AND NFPA 241.
14. EXAMINATION: VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED
AND CAPPED BEFORE STARTING SELECTIVE DEMOLITION
OPERATIONS.
15. UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS: EXISTING
SERVICES/SYSTEMS TO REMAIN: MAINTAIN SERVICES/SYSTEMS
INDICATED TO REMAIN AND PROTECT THEM AGAINST DAMAGE.
EXISTING SERVICES/SYSTEMS TO BE REMOVED, RELOCATED, OR
ABANDONED: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF
UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS SERVING
AREAS TO BE SELECTIVELY DEMOLISHED. OWNER WILL ARRANGE TO
SHUT OFF INDICATED SERVICES/SYSTEMS WHEN REQUESTED BY
CONTRACTOR. ARRANGE TO SHUT OFF UTILITIES WITH UTILITY
COMPANIES. IF SERVICES/SYSTEMS ARE REQUIRED TO BE REMOVED,
RELOCATED, OR ABANDONED, PROVIDE TEMPORARY
SERVICES/SYSTEMS THAT BYPASS AREA OF SELECTIVE DEMOLITION
AND THAT MAINTAIN CONTINUITY OF SERVICES/SYSTEMS TO OTHER
PARTS OF BUILDING. DISCONNECT, DEMOLISH, AND REMOVE
FIRE-SUPPRESSION SYSTEMS, PLUMBING, AND HVAC SYSTEMS,
EQUIPMENT, AND COMPONENTS INDICATED ON DRAWINGS TO BE
REMOVED. PIPING TO BE REMOVED: REMOVE PORTION OF PIPING
INDICATED TO BE REMOVED AND CAP OR PLUG REMAINING PIPING
WITH SAME OR COMPATIBLE PIPING MATERIAL. PIPING TO BE
ABANDONED IN PLACE: DRAIN PIPING AND CAP OR PLUG PIPING WITH
SAME OR COMPATIBLE PIPING MATERIAL AND LEAVE IN PLACE.
EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP SERVICES AND
REMOVE EQUIPMENT. EQUIPMENT TO BE REMOVED AND
REINSTALLED: DISCONNECT AND CAP SERVICES AND REMOVE, CLEAN,
AND STORE EQUIPMENT; WHEN APPROPRIATE, REINSTALL,
RECONNECT, AND MAKE EQUIPMENT OPERATIONAL. EQUIPMENT TO
BE REMOVED AND SALVAGED: DISCONNECT AND CAP SERVICES AND
REMOVE EQUIPMENT AND DELIVER TO OWNER. DUCTS TO BE
REMOVED: REMOVE PORTION OF DUCTS INDICATED TO BE REMOVED
AND PLUG REMAINING DUCTS WITH SAME OR COMPATIBLE DUCTWORK
MATERIAL. DUCTS TO BE ABANDONED IN PLACE: CAP OR PLUG DUCTS
WITH SAME OR COMPATIBLE DUCTWORK MATERIAL AND LEAVE IN
PLACE.
16. PROTECTION: TEMPORARY PROTECTION: PROVIDE TEMPORARY
BARRICADES AND OTHER PROTECTION REQUIRED TO PREVENT
INJURY TO PEOPLE AND DAMAGE TO ADJACENT BUILDINGS AND
FACILITIES TO REMAIN. TEMPORARY SHORING: DESIGN, PROVIDE, AND
MAINTAIN SHORING, BRACING, AND STRUCTURAL SUPPORTS AS
REQUIRED TO PRESERVE STABILITY AND PREVENT MOVEMENT,
SETTLEMENT, OR COLLAPSE OF CONSTRUCTION AND FINISHES TO
REMAIN, AND TO PREVENT UNEXPECTED OR UNCONTROLLED
MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING DEMOLISHED.
REMOVE TEMPORARY BARRICADES AND PROTECTIONS WHERE
HAZARDS NO LONGER EXIST.
17. SELECTIVE DEMOLITION: GENERAL: DEMOLISH AND REMOVE EXISTING
CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW
CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO
COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING
REGULATIONS AND AS FOLLOWS: SITE ACCESS AND TEMPORARY
CONTROLS: CONDUCT SELECTIVE DEMOLITION AND DEBRIS-REMOVAL
OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS,
STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND
USED FACILITIES. NEATLY CUT OPENINGS AND HOLES PLUMB,
SQUARE, AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING
METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAIN OR
ADJOINING CONSTRUCTION. USE HAND TOOLS OR SMALL POWER
TOOLS DESIGNED FOR SAWING OR GRINDING, NOT HAMMERING AND
CHOPPING. TEMPORARILY COVER OPENINGS TO REMAIN. CUT OR
DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED
SURFACES TO AVOID MARRING EXISTING FINISHED SURFACES. DO
NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF
FLAMMABLE MATERIALS. AT CONCEALED SPACES, SUCH AS DUCT AND
PIPE INTERIORS, VERIFY CONDITION AND CONTENTS OF HIDDEN
SPACE BEFORE STARTING FLAME-CUTTING OPERATIONS. MAINTAIN
PORTABLE FIRE-SUPPRESSION DEVICES DURING FLAME-CUTTING
OPERATIONS. MAINTAIN FIRE WATCH DURING AND FOR AT LEAST TWO
HOURS AFTER FLAME-CUTTING OPERATIONS. LOCATE SELECTIVE
DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS
NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS,
OR FRAMING. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS
PROMPTLY. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED
ITEMS. PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS
OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY
TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA
DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING
TRANSPORT AND STORAGE. REMOVED AND REINSTALLED ITEMS:
EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO
REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE
DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE
REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING
SELECTIVE DEMOLITION AND CLEANED AND REINSTALLED IN THEIR
ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS
ARE COMPLETE. CLEAN AND REPAIR ITEMS TO FUNCTIONAL
CONDITION ADEQUATE FOR INTENDED REUSE. PACK OR CRATE ITEMS
AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF
CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT
AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY
WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND
EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND
MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL
FOR USE INDICATED.
18. CLEANING: REMOVE DEMOLITION WASTE MATERIALS FROM PROJECT
SITE [AND DISPOSE OF THEM IN AN EPA-APPROVED CONSTRUCTION
AND DEMOLITION WASTE LANDFILL ACCEPTABLE TO AUTHORITIES
HAVING JURISDICTION. BURNING: DO NOT BURN DEMOLISHED
MATERIALS. DO NOT ALLOW DEMOLISHED MATERIALS TO
ACCUMULATE ON-SITE. REMOVE AND TRANSPORT DEBRIS IN A
MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT SURFACES AND
AREAS. REMOVE DEBRIS FROM ELEVATED PORTIONS OF BUILDING BY
CHUTE, HOIST, OR OTHER DEVICE THAT WILL CONVEY DEBRIS TO
GRADE LEVEL IN A CONTROLLED DESCENT. CLEAN ADJACENT
STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS
CAUSED BY SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT
AREAS TO CONDITION EXISTING BEFORE SELECTIVE DEMOLITION
OPERATIONS BEGAN.
GENERAL DEMOLITION NOTES
1 REVIEW COMMENTS 2018/08/07
ARCHITECTURAL ABBREVIATIONS
A.B.
A.B.C.
A/C
AC(T)
A.D.
ADJ
AFC
AFF
ALLOW
ALT
ALUM
AMP
A.O.
A.P.
AUTO
L
APPX.
ARCH
BD
B.L.
BLDG.
BM
B.M.
BOT
BRG
BSMT
BTWN
B.U.
B.F.
B.G.
BLK(G)
BRG.
CAB
C.B.
CEM
CEM PLAS
CER
CH
C.F.C.I.
CFM
C.I.
C.I.P.
CIR
C.J.
C.G.
C.L.
CLG
CLR
CMU
C.O.
COL
COMB
CONC
CONST
CONT
CPT
CSK
C.T.
C.W.
CORR.
CORRUG.
DEMO
DTL.
D.F.
DIA.
DIAG
DIM
DISP.
DN
DO
DR
D.S.
DWG
EA
EC
E.F.
E.J.
ELEC.
ELEV.
ENT
EQ
EQUIP
E.W.
EWC
EXH
EXIST OR E
EXP
EXT
F.A.
F.D.
F.C.O.
FDN
F.E.
FEC
FFE
FIN
FIXT.
FLSH
FLR
F.O.
F.S.
FT
FTG.
FURR
FUT
FV
GA
GALV
GL
GLB
GND
GWB
GYP.
H.B.
H.C.
HDW
H.M.
HORIZ
H.P.
HT
H.W.
HWR
I.D.
I.F.
IN.
INFO
INS
INT
J.B.
J.C.
JST
JT
KIT.
K.O.
L
LAB
LAV
LBS
LIN. FT.
MAS
MAT
MAX
M.B.
MC
MCJ
MECH
MEMB
MFG
MH
MIN.
MISC
ML
MO
MTD
MTG
MET
MUL
N/A
NIC
NOM
NO.
NTS
O.A.
O.C.
O.D.
O.F.
O.F.C.I.
O.F.O.I.
OH
OPNG
OPP
P
P.C.
PERIM.
PERP
PL
P.L.
PLAS
PL GL
PL. LAM.
PLYWD
PNL
PR
PROJ
PSI
PSF
PT
PTN
PVC
PTD
POL.
Q.T.
QTY
R
RA
R.C.P.
RECEPT
R.D.
REC
REF.
REFRIG.
REG
REINF
REQD
REV
RFG
R.H.
RM
R.O.
R.O.W.
RWL
S.C.
SCHED
S.D.
SECT.
SQ. FT.
SHT.
SIM.
SLV
SHT MET
SPEC.
SPKR
SQ.
S.S.
S. STL
ST
STD
STOR
STL
STRUCT
SUSP CLG
S.V.
T
T&G
TEL
TEMP
TH
THR
T.O.
T.O.B.
T.O.C.
T.O.F.
T.O.J.
T.O.M.
T.O.P.
T.O.W.
T.T.B
TV
TYP.
UNO
UON
V
VCP
VCT
VERT
VT.
VTR
V.W.C.
FIRE ALARM
FLOOR DRAIN
FLOOR CLEAN OUT
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR ELEVATION
FINISH
FIXTURE
FLASHING
FLOOR
FACE OF
FLOOR SINK
FEET, FOOT
FOOTING
FURRING
FUTURE
FIELD VERIFY
GAUGE
GALVANIZED
GLASS
GLUE LAMINATED BEAM
GROUND
GYPSUM WALL BOARD
GYPSUM
HOSE BIB
HOLLOW CORE
HARDWARE
HOLLOW METAL
HORIZONTAL
HORSEPOWER
HEIGHT
HOT WATER
HOT WATER RETURN
INSIDE DIAMETER
INSIDE FACE
INCH (ES)
INFORMATION
INSULATION
INTERIOR
JUNCTION BOX
JANITOR CLOSET
JOIST
JOINT
KITCHEN
KNOCK OUT
LONG, LENGTH
LABORATORY
LAVATORY
POUNDS
LINEAR FEET
MASONRY
MATERIAL
MAXIMUM
MACHINE BOLT
MECHANICAL CONTRACTOR
MASONRY CONTROL JOINT
MECHANICAL
MEMBRANE
MANUFACTURER
MANHOLE
MINIMUM
MISCELLANEOUS
METAL LATH
MASONRY OPENING
MOUNTED
MOUNTING
METAL
MULLION
NOT APPLICABLE
NOT IN CONTRACT
NOMINAL
NUMBER
NOT TO SCALE
OVERALL
ON CENTER
OUTSIDE DIAMETER
OUTSIDE FACE
OWNER FURNISHED, CONTRACTOR
INSTALLED
OWNER FURNISHED, OWNER INSTALLED
OVERHEAD
OPENING
OPPOSITE
ANCHOR BOLT GA GAUGE
AGGREGATE BASE COURSE
AIR CONDITIONING
ACOUSTICAL CEILING (TILE)
ACCESS DOOR
ADJACENT
ABOVE FINISH CEILING
ABOVE FINISH FLOOR
ALLOWANCE
ALTERNATE
ALUMINUM
AMPERE
ACCESS OPENING
ACCESS PANEL
AT
AUTOMATIC
ANGLE
APPROXIMATE(LY)
ARCHITECT(URAL)
BOARD
BUILDING LINE
BUILDING
BEAM
BENCH MARK
BOTTOM
BEARING
BASEMENT
BETWEEN
BUILT UP
BELOW FLOOR
BELLOW GRADE
BLOCK(ING)
BEARING
CABINET
CATCH BASIN
CEMENT
CEMENT PLASTER
CERAMIC
CHANNEL
CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CUBIC FEET PER MINUTE
CAST IRON
CAST IN PLACE
CIRCUIT
CONTROL JOINT
CORNER GUARD
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
CLEAN OUT
COLUMN
COMBINATION
CONCRETE
CONSTRUCTION
CONTINUOUS
CARPET
COUNTERSINK
CERAMIC TILE
COLD WATER
CORRIDOR
CORRUGATED
DEMOLISH (DEMOLITION)
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DISPENSER
DOWN
DITTO
DOOR
DOWNSPOUT
DRAWING
EACH
ELECTRICAL CONTRACTOR
EACH FACE
EXPANSION JOINT
ELECTRICAL
ELEVATION
ENTRANCE
EQUAL
EQUIPMENT
EACH WAY
ELECTRIC WATER COOLER
EXHAUST
EXISTING
EXPANSION
EXTERIOR
PAVEMENT
PULL CHAIN
PERIMETER
PERPENDICULAR
PLATE
PROPERTY LINE
PLASTER
PLATE GLASS
PLASTIC LAMINATE
PLYWOOD
PANEL
PAIR
PROJECT
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PRESSURE TREATED
PARTITION
POLYVINYL CHLORIDE
PAINTED
POLISHED
QUARRY TILE
QUANTITY
RISER OR RADIUS
RETURN AIR
REFLECTED CEILING PLAN
RECEPTACLE
ROOF DRAIN
RECESSED
REFERENCE
REFRIGERATOR
REGISTER
REINFORCEMENT
REQUIRED
REVISION
ROOFING
RIGHT HAND
ROOM
ROUGH OPENING
RIGHT OF WAY
RAIN WATER LEADER
SOLID CORE
SCHEDULE
STORM DRAIN
SECTION
SQUARE FOOT
SHEET
SIMILAR
SHORT LEG VERTICAL
SHEET METAL
SPECIFICATION(S)
SPEAKER
SQUARE
SERVICE SINK
STAINLESS STEEL
STATION
STANDARD
STORAGE
STEEL
STRUCTURAL
SUSPENDED CEILING
SHEET VINYL
TREAD
TONGUE AND GROOVE
TELEPHONE
TEMPERED
THICK
THRESHOLD
TOP OF
TOP OF BEAM
TOP OF CURB
TOP OF FOOTING
TOP OF JOIST
TOP OF MASONRY
TOP OF PARAPET
TOP OF WALL
TELEPHONE TERMINAL BOARD
TELEVISION
TYPICAL
UNLESS NOTED OTHERWISE
UNLESS OTHERWISE NOTED
VENTILATION
VITRIFIED CLAY PIPE
VINYL COMPOSITION TILE
VERTICAL
VENT
VENT THROUGH ROOF
VINYL WALL COVER
W/
W.C.
WCO
WD
WDW
WHI
WP
W.R.
WRGWB
WSCT
WT
WWM
YD.
WITH
WATER CLOSET
WALL CLEAN OUT
WOOD
WINDOW
WARNOCK HERSEY INTERNATIONAL
WATER PROOF
WATER RESISTANT
WATER RESISTANT GYPSUM WALL
BOARD
WAINSCOT
WEIGHT
WELDED WIRE MESH
YARD
GENERAL NOTES:
1. VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THE WORK.
DISCREPANCIES (IF ANY.) ARE TO BE REFERRED TO THE PROJECT ARCHITECT / ENGINEER FOR SETTLEMENT.
2. IN GENERAL, THE PLAN DIMENSIONS SHOWN ARE:
A. TO THE FACE OF STUD AT STUD PARTITIONS AND FURRING.
B. TO THE FACE OF CONCRETE, AND CONCRETE WALLS.
C. TO THE COLUMN GRID LINES.
D. WHERE NOTED, "F.F" DIMENSION IS TO FACE OF EXISTING FINISH.
E. WHERE NOTED, "ALIGN" LOCATE NEW WORK TO ALIGN FINISHED SURFACES.
3. DO NOT SCALE THE DRAWINGS.
4. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL BE (6) INCHES FROM FACE OF FINISH IN
ADJACENT RIGHT ANGLE WALL TO EDGE OF DOOR OPENING AT HINGE SIDE (OR 18" MIN. TO THE LATCH SIDE), OR
CENTERED BETWEEN ROOM PARTITIONS, AS SHOWN.
5. ALL FIRE RATED WALLS AND SMOKE PARTITIONS ARE TO BE CONTINUOUS FROM FLOOR TO UNDERSIDE OF
STRUCTURE ABOVE UNLESS NOTED OTHERWISE OR WHEN THE CEILING ASSEMBLY IS RATED.
6. WHERE ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, OR OTHER ITEMS ARE RECESSED IN FIRE RATED FIXTURES, WALLS OR PARTITIONS, LINE THE BACK AND SIDES OF THE WALL AND RECESS WITH GYPSUM WALL BOARD TO
MAINTAIN FIRE-RESISTIVE CONSTRUCTION OF THE WALL.
7. THE CONTRACTOR SHALL COORDINATE ALL TRADES FOR ALL OPENINGS THROUGH NEW OR EXISTING
CONSTRUCTION FOR DUCTS, PIPES, CONDUITS, CABINETS, AND EQUIPMENT. VERIFY SIZES, AND LOCATIONS.
8. USE APPROVED FIRE STOP SLEEVES, AND SEALANTS WHERE PIPES, DUCTS, CONDUITS, OR OTHER SYSTEMS
PENETRATE FIRE OR SMOKE-RESISTIVE WALLS.
9. PACK MINERAL FIBER INSULATION AROUND PIPES, CONDUITS, DUCTS, OR OTHER EQUIPMENT THAT PENETRATE NON-
RATED PARTITIONS.
10. VERIFY ALL ROUGH-IN DIMENSIONS, AND SERVICE CONNECTION REQUIREMENTS FOR OWNER-FURNISHED
EQUIPMENT, AND EQUIPMENT INCLUDED IN THIS CONTRACT.
11. ALL TRADES WORKING CONCURRENTLY TOGETHER WHICH ARE INTERDEPENDENT INSTALLATIONS SHALL
COORDINATE AND SEQUENCE THEIR INSTALLATIONS TO FACILITATE THE TIMELY INSTALLATION OF BOTH TRADES.
12. G.C. SHALL COORDINATE ALL TRADES, PRIOR TO THE START OF AND DURING, THE WORK, TO ASSURE PROPER
SEQUENCING OF THE CONSTRUCTION AND COMPLIANCE WITH THE CONSTRUCTION SCHEDULE.
13. G.C. SHALL OVERSEE ALL TRADE WORK WITH EMPHASIS ON WORK WHICH IS TO RECEIVE THAT OF A SUBSEQUENT
TRADE. THE G.C. SHALL REVIEW, WITH THE SUCCEEDING TRADE, THE SUPPORTING WORK AND TAKE CORRECTIVE
ACTION ON DEFECTIVE WORK.
14. ALL TRADES SHALL REPORT DEFECTIVE CONDITIONS OF OTHER WORK INTENDED TO SUPPORT THEIR INSTALLATION 5
WORKING DAYS PRIOR TO THEIR SCHEDULED START DATE.
14. ALL WORK OUTSIDE THE BUILDING ENVELOPE SHALL REQUIRE THE LOCATION OF UNDERGROUND UTILITIES, IN THE SUBJECT
WORK AREA, TO BE IDENTIFIED BY BLUESTAKE AT GRADE. IDENTIFICATION SHALL INDICATED ROUTE AND UTILITY TYPE.
UTILITIES DISCOVERED BUT NOT IDENTIFIED ON THE SURVEY OR CIVIL / ARCHITECTURAL UTILITY / SITE PLANS OR WHOSE
ROUTES DO NOT CONFORM TO THOSE INDICATED ON THE SURVEY OR CIVIL / ARCHITECTURAL UTILITY / SITE PLANS SHALL
BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT / ENGINEER BEFORE BEGINNING WORK IN THAT AREA.
15. NEW MATERIALS, EQUIPMENT, ASSEMBLIES, COMPONENTS, ACCESSORIES, ETC. SHALL MATCH & CONFORM TO THE
SAME PRODUCTS IN THE EXISTING FACILITY AS DEFINED IN THE OWNER'S 'MAINTENANCE & OPERATIONS' STANDARD
TO ASSURE UNIFORMITY, INTERCHANGEABILITY, AND COMPATIBILITY WITH AND BETWEEN EXISTING AND NEW.
16. COORDINATE THE LOCATION OF TEMPORARY CONSTRUCTION FACILITIES WITH THE OWNERS REPRESENTATIVE AND FACILITY
OPERATIONS MANAGER (AS APPLICABLE) TO PROVIDE PARKING AND EXTERIOR LAYDOWN STORAGE SPACE.
17. THE STORAGE OF MATERIALS AND EQUIPMENT SHALL COMPLY WITH CHAPTER 33 OF THE IBC. ALL MATERIALS AND EQUIPMENT
MUST BE STORED AND PLACED SO AS NOT TO ENDANGER THE PUBLIC, THE WORKERS OR ADJOINING PROPERTY FOR THE
DURATION OF CONSTRUCTION
18. G.C. SHALL COORDINATE THE INSTALLATION OF ALL CONCRETE SLAB AND DECK WORK WITH THE ARCHITECTURAL DIMENSION
AND SLAB PLANS FOR THE LIMITS, CONFIGURATION AND SLOPES REQUIRED TO FACILITATE DRAINAGE TOWARD THE INDICATED
FLOOR DRAIN(S) AND SET DRAIN HEIGHTS AS REQUIRED TO INTERFACE WITH THE FINAL FLOOR FINISH. IN ADDITION THE G.C.
SHALL REVIEW WITH THE PLUMBING SUBCONTRACTOR AND IDENTIFY ANY FLOOR DRAIN CONDITIONS WHERE SLAB SLOPES
HAVE NOT BEEN INDICATED AND NOTIFY THE ARCHITECT OF RECORD OF SUCH CONDITIONS 2 WEEKS PRIOR TO THE
INSTALLATION OF CONCRETE.
A. FLOOR SLOPES SHALL BE 1/8" PER FOOT.
B. MAINTAIN MIN. CONC. COVERAGE OF CONCRETE REINF AS INDICATED ON STRUCTURAL DRAWINGS.
i. WHERE CONCRETE SLAB THICKNESS IS REQUIRED TO BE REDUCED REDUCTION CAN NOT EXCEED 1"
ii. RATED FLOOR ASSEMBLIES OF REDUCED THICKNESS SHALL RECEIVE SPRAY APPLIED FIRE PROOFING
TO THE (CONCEALED) BOTTOM SIDE OF SUFFICIENT THICKNESS TO ADD 1 HOUR OF FIRE PROOFING
PROTECTION.
19. STANDARDS - WARNOCK HERSEY INTERNATIONAL (WHI) INTERTEK. AS AN OSHA RECOGNIZED NRTL LAB, PERFORMS
PRODUCT COMPLIANCE TESTING FOR COMPLIANCE WITH: ANSI, UL, ASTM, CCMC, CSA, EPS, ICBO AND ULC
STANDARDS.
DIMENSION LINE
DIM
SCALE:1
View Name
1/8" = 1'-0"
DRAWING BLOCK TITLE
ELEVATION REF.
EXTERIOR
A101
A1
ELEVATION INDICATOR
GROUND FFE = 100'-0"
CENTER LINE INDICATOR
FEATURES ABOVE LINE
CONTRACT LIMIT LINE
DEMOLITION LINE
SSSS
SSSS
SSSS
SSSS
FIRE RESISTIVE RATED
2 HOUR
FIRE RESISTIVE RATED
1 HOUR
FIRE RATED, SMOKE BARRIER
1 HOUR
FIRE RATED, SMOKE BARRIER
2 HOUR
HIDDEN FEATURE LINE
NEW LINE
PROPERTY LINE
BREAK, ROUND
BREAK, STRAIGHT
Room Name
121-100
Room Code Stand.
ROOM TAGRM #
PROGRAM
SQ. FT.
112-100
SEQUENCE NUMBER
KEY PLAN ZONE
KEY PLAN AREA
BUILDING LEVEL
MODIFIER
DRAWING
MARK
SHEET
NUMBER
MODIFIER
DRAWING
MARK
DRAWING
MARK
SHEET
NUMBER
SHEET
NUMBER
MATCHLINE / VIEW
REFERENCE TAG
DETAIL CALLOUT
DETAIL SECTION
ELEVATION REF.
INTERIOR
GRID HEAD
GRID HEAD - EXISTING
LEVEL TAG
GROUND FFE = 100'-0"
A1
A101
SIM
A1
A101
A101
A1
A3
A2A4
100'-0"
LEVEL NAME
SIM
1/A101
ARCHITECTURAL ANNOTATION SYMBOLS
A00
WINDOW / GLAZED
PANEL TAG
MARK
FIRE
RATING
(MINUTES)
100A
90 000
DOOR TAG
FIRE
RATING
(MINUTES)
HARDWARE MARK
MARK
WALL TAG
CONST. NOTE
TAG
DEMOLITION
TAG
SPECIALTY
EQUIPMENT
TAG
REVISION
TAG
A00
0'- 0"
CEILING TAGMARK
HEIGHT
ACTUAL
SQ. FT.
X.000
90 00
FIRE RATING
(MINUTES)
SOUND RATING
(STC)
MARK
DRAWING
MARK
SHEET
NUMBER
MODIFIER
DRAWING
MARK
SHEET
NUMBER BUILDING SECTION
SIM
A1
A101
A1
A101 or or or or
100'-0" .
or
FIRE RESISTIVE RATED
3 HOUR
or
FIRE RESISTIVE RATED
4 HOURor
FIRE RATED, SMOKE BARRIER
3 HOUR
FIRE RATED, SMOKE BARRIER
4 HOUR
or or
FURNISHING
TAG
C-0
X
SCHEDULE REF.
M = MEDICAL EQUIP.
D = DENTAL EQUIP.
O = OPERATIONS EQUIP.
R = RESTROOM EQUIP.
F = FOOD SERVICE
EQUIP.
L = LAB EQUIP.
MARK
C = CHAIR S = SHELF
D = DESK BS = BOX
SHELF
T = TABLE
MARK
MILL /
CASEWORK
TAG
B24
B = BASE CABINET
DB = DRAWER BASE
SB = SINK BASE CABINET
W = WALL CABINET
MARK (WIDTH INCHES)
XX XX
XX
PHASE
(E) EXISTING
GA. (STEEL)
MIL. THICKNESS (STEEL)
AL111
SHEET NUMBERING
SHEET SEQUENCE 1-9
LEVEL
DRAWING TYPE / VIEW
ASSEMBLY / FUNCTION
DISCIPLINE (ARCHITECTURAL)
0 - GENERAL / CODE 5 - DETAILS
1 - PLANS 6 - DIAGRAMS
2 - ELEVATIONS 7 - SCHEDULES
3 - SECTIONS 8 - SPECIFICATIONS
4 - ENLARGED VIEWS 9 - IMAGERY
A - AREA R - ROOF
B - BUILDING S - SITE
C - CEILINGS V - VERTICAL CIRC.
D - DEMOLITION W - WALLS
G - GENERAL X - DETAILS
I - INTERIORS Y - SCHEDULES
L - LEVEL Z - SPECIFICATION
OCC
EWR
EWP
ROOM OCCUPANT LOAD
EXIT WIDTH REQUIRED
EXIT WIDTH PROVIDED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering Discipline: A/E:
C U s e rs
\s k e s s le r\ D o c u m e n ts
\1
.0
V
A T u c s o n
C M
O P
S to ra g e M e z z a n in e
A
R C
H
(R
G L
H N s k e s s le r.
rv t
/1
/2
:2
:2
P
M
AG001
ARCH. ABBREV., SYMBOLS,
ANNOTATIONS AND GEN. NOTES
Turner Structural Engineering
3026 N. Country Club
Tucson, AZ 85716
(520) 323-3422
Jim Hart
Tucson CMOP Storage Mezzanine
3675 E. Brittania Dr., Tucson, AZ
762-18-01
Project Director
June 14, 2018 BH SK/EP
100% CONSTRUCTION
DOCUMENTS
GLHN Architects & Engineers, Inc.
2939 E. Broadway Blvd.
Tucson, AZ 85716
(520) 881-4546
Ted Moeller
GLHN PROJECT # 17073.00
Revisions: Date:
10-0
10-0
10-0
OFFICEOFFICEOFFICEOFFICEOFFICEOFFICE
STORAGE
STORAGE
OFFICE
OFFICE
COMPUTER
TELEPHONE
TRAINING
UPS
HALLWAY
TRAININGOFFICE STORAGE
HALLWAY
HALLWAY
HALLWAY
OFFICEOFFICEOFFICEOFFICEOFFICESTORAGE
JANITOR
OFFICE
CONFERENCE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALLWAY
WOMENS
MENS
RECEPTION
COPY ROOMSTORAGE STORAGE
BREAKROOM
MENS
WOMEN
WOMEN
VESTIBULE
LAUNDRY
WOMEN LKRWOMEN'S TLT
MEN
MENS LKR
MEN'S TLT
BREAKROOM
VESTIBULE
SHIP/RECV-
ELEC
OFFICE
WOMEN
MEN
WOMEN'S SHWR
MEN'S SHWR
126 125 123 122 121 120
162 127
136135
1 2
3 4
5 6 7 8 9 10
A
B
C
D
A
B
C
D
EE
D.9
9 101 8765432
39'-8" 40'-0" 40'-0" 40'-0" 40'-0" 40'-0" 39'-4"
1_
" 5'-0"
358'-8"
A
A
B
CODE SUMMARY
PERMIT EXISTING BUILDING
EXISTING BUILDING PERMITED IN 2004, PERMIT NO. T04CM01811. THE FOLLOWING INFORMATION IS TAKEN FROM
THE ORIGINAL BUILDING CODE DATA PERMITTED UNDER THE IBC 2000.
APPLICABLE CODES:
2012 INTERNATIONAL BUILDING CODE (IBC) AND LOCAL AMENDMENTS
2011 NATIONAL ELECTRIC CODE (NEC) AND LOCAL AMENDMENTS
2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) AND LOCAL AMENDMENTS
2012 INTERNATIONAL EXISTING BUILDING CODE (IEBC) AND LOCAL AMENDMENTS
2012 INTERNATIONAL FUEL GAS CODE (IFGC) AND LOCAL AMENDMENTS
2012 INTERNATIONAL MECHANICAL CODES (IMC) AND LOCAL AMENDMENTS
2012 INTERNATIONAL PLUMBING CODE (IPC) AND LOCAL AMENDMENTS
2012 INTERNATIONAL FIRE CODE (IFC) AND LOCAL AMENDMENTS
CITY OF TUCSON/PIMA COUNTY OUTDOOR LIGHTING CODE
CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION
SECTION 306, FACTORY GROUP F
306.1 MODERATE-HAZARD FACTORY INDUSTRIAL GROUP F-1
F OCCUPANCY INCLUDES... THE USE OF A BUILDING...FOR ASSEMBLING, DISASSEMBLING, FABRICATING, FINISHING, MANUFACTURING, PACKAGING, REPAIR OR PROCESSING OPERATIONS THAT ARE NOT CLASSIFIED AS A GROUP H
HAZARDOUS OR GROUP S STORAGE OCCUPANCY.
F-1 OCCUPANCY INCLUDES;
ENGINES (INCLUDING REBUILDING)
MACHINERY
METALS
CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS
TABLE 503 - ALLOWABLE BUILDING HEIGHTS AND AREAS
CONSTRUCTION TYPE: TYPE II-B
ALLOWABLE ACTUAL % OF TOTAL
BUILDING HEIGHT: 50-FEET 31-FEET
BUILDING AREA: F-1 (INCL A3) 79,299 SQ. FT. 64,023 SQ. FT. = 81%
B 117,669 SQ. FT. 17,175 SQ FT. = 15%
96% < 1, COMPLIES
BUILDING ALLOWABLE AREA (Aa) FOR EACH PORTION OF THE BUILDING PLUS SPRINLER INCREASE 'Is' (3x) PLUS
FRONTRAGE INCREASE (If) (PER 506.1 WIDTH LIMITS, EXCEPTION INCREASE 'W' VALUE LIMIT TO 2) = TOTAL Aa.
F-1 = 15,500 BASIC Aa + 46,500 Is + 17,299 If = 79,299
B = 23,000 BASIC Aa + 69,000 Is + 25,669 If = 117,669
MEZZANINES
505.2 MEZZANINES.
A MEZZANINE OR MEZZANINES IN COMPLIANCE WITH SECTION 505.2 SHALL BE CONSIDERED A PORTION OF THE
STORY BELOW. SUCH MEZZANINES SHALL NOT CONTRIBUTE TO EITHER THE BUILDING AREA OR NUMBER OF STORIES
AS REGULATED BY SECTION 503.1.
505.2.1 AREA LIMITATION.
THE AGGREGATE AREA OF A MEZZANINE OR MEZZANINES WITHIN A ROOM SHALL BE NOT GREATER THAN ONE-
THIRD OF THE FLOOR AREA OF THAT ROOM OR SPACE IN WHICH THEY ARE LOCATED.... IN DETERMINING THE
ALLOWABLE MEZZANINE AREA, THE AREA OF THE MEZZANINE SHALL NOT BE INCLUDED IN THE FLOOR AREA OF THE
ROOM.
505.2.3 OPENNESS.
A MEZZANINE SHALL BE OPEN AND UNOBSTRUCTED TO THE ROOM IN WHICH SUCH MEZZANINE IS LOCATED EXCEPT
FOR WALLS NOT MORE THAN 42 INCHES (1067) IN HEIGH, COLUMNS AND POSTS.
EXCEPTION 5. IN OCCUPANCIES OTHER THAN GROUPS H AND I, THAT ARE NO MORE THAN TWO STORIES
ABOVE GRADE PLANE AND EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN
ACCORDANCE WITH SECTION 903.3.1.1, A MEZZANINE HAVING TWO OR MORE MEANS OF EGRESS SHALL
NOT BE REQUIRED TO BE OPEN TO THE ROOM IN WHICH THE MEZZANINE IS LOCATED.
TABLE 508 REQUIRED SEPARATION OF OCCUPANCIES
IN A FIRE SPRINKLERED BUILDING NO SEPARATION IS REQUIRED BETWEEN F-1 AND B OCCUPANCIES. THE
ACCESSORY A-3 OCCUPANCY IS LESS THAN 10% OF THE PRIMARY F-1 OCCUPANCY AND THERE FORE IS
CONSIDERED PART OF THE F-1 OCCUPANCY PER SECTION 508.2.4
TABLE 601 FIRE RESISTANCE RATING FOR BUILDING ELEMENTS (HOURS) TYPE II-B CONSTRUCTION
PRIMARY STRUCTUAL FRAME = 0
BEARING WALLS EXTERIOR = 0
BEARING WALLS INTERIOR = 0
NONBEARING WALLS AND PARTITIONS EXTERIOR = 0 (GREATER THAN 30 FEET SEPARATION)
NONBEARING WALLS AND PARTITIONS INTERIOR = 0
FLOOR CONSTRUCTION = 0
ROOF CONSTRUCTION = 0
AL119
G6
SIM
AL119
G3
SIM
5 6 74.2 4.5 5.5 6.5 7.5 7.74
B
A.6
A A.1
A.3
PER 505.2.3 MEZZANINE
ENCLOSURE ALLOWED.
STORAGE MEZZANINE
PER 505.2.1 MEZZANINE IS LESS
THAN 1/3 OF THE AREA OF ROOM
WHERE LOCATED
5825 / 54979 = 10.6%, COMPLIES.
OCCUPANT LOAD 5825 / 300 = 20 OCC.
TWO EXITS PROVIDED PER TABLE
1021.2 - TRAVEL DISTANCE EXCEEDS 75 FEET.
59778 SF
F-1
3750 SF
A-3
16619 SF
B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering Discipline: A/E:
C U s e rs
\s k e s s le r\ D o c u m e n ts
\1
.0
V
A T u c s o n
C M
O P
S to ra g e M e z z a n in e
A
R C
H
(R s k e s s le r_ G
L H
N .r v t
/6
/2
:0
:2
P M
AG111
CODE COMPLIANCE - LIFE SAFETY
Turner Structural Engineering
3026 N. Country Club
Tucson, AZ 85716
(520) 323-3422
Jim Hart
Tucson CMOP Storage Mezzanine
3675 E. Brittania Dr., Tucson, AZ
762-18-01
Project Director
August 07, 2018 BH SK
100% CONSTRUCTION
DOCUMENTS
GLHN Architects & Engineers, Inc.
2939 E. Broadway Blvd.
Tucson, AZ 85716
(520) 881-4546
Ted Moeller
GLHN PROJECT # 17073.00
LEGEND - OCCUPANCY ANALYSIS TABLE
L.T. = '<' LESS THAN
MFA = MAX FLOOR AREA (PER OCCUPANT)
N.A. = NOT APPLICABLE
N.P. = NOT PERMITTED
N.R. = NOT REQUIRED
O.C. = OCCUPANCY CLASSIFICATION
O.L. = OCCUPANT LOAD
1. AREAS ARE DERIVED BASED ON THE INTERIOR PERIMETER WALL LIMITS AS DETERMINED BY IBC
SECTION 1002 'DEFINITIONS - FLOOR AREA, GROSS" WHICH ARE BASED ON THE "INSIDE
PERIMETER OF THE EXTERIOR WALLS".
2. ZONE COLUMN DEFINES AREAS SEPARATED BY 1 HR OR GREATER FIRE SEPARATION WALLS
3. ADJUSTED (O.L.) COLUMN ADJUSTS THE OCCUPANT LOAD BASED ON ACTUAL LOAD
CONDITIONS, EITHER AS A KNOWN FIXED OCCUPANCY OR CUMULATIVE LOADING AS
EXPERIENCE BY EXIT CORRIDORS.
4. AREAS EXCLUDED FROM THE OCCUPANCY CALCULATION UNDER THE 'NET' AREA ASSIGNMENT
OF IBC TABLE 1004.1.2 INCLUDE: CORRIDORS, HALLWAYS, RESTROOMS, JANITOR CLOSETS,
STAIRWELLS, MECHANICAL ROOMS, CLOSETS, VERTICAL SHAFTS AND ELEVATORS.
5. AREAS EXCLUDED BASED ON USE RELATIONSHIP BEYOND THIS IMPROVEMENT
> A106 AUTO REPAIR - EXTERIOR BAY NOT ENCLOSED, NOT PART OF THE CHAPEL FUNCTION
> A107, 108 & 109 SERVE THE RETAIL FUNCTION, NOT PART OF THE CHAPEL FUNCTION
6. AREA EXCLUDED FROM THE OCCUPANCY CALCULATION UNDER 1018.6 CORRIDOR CONTINUITY
PROVISION OF THE 2012 IBC. LOBBY IS DEFINED AS A CORRIDOR, NOT AN INTERVENING ROOM
7. AREA CATEGORIZED AS A 'B' OCCUPANCY UNDER 2012 IBC 303.1.2 ITEM 2
CPET = COMMON PATH EGRESS TRAVEL
DISTANCE TO TWO SEPARATE AND
DISTINCT PATHS OF EGRESS
EATD = EXIT ACCESS TRAVEL DISTANCE
DISTANCE TO AN EXIT: EXTERIOR EXIT DOOR
TO PUBLIC WAY, EXIT STAIRS & RAMPS, RATED
EXIT PASSAGEWAYS, HORIZ. EXITS)
ETD = EXIT TRAVEL DISTANCE
F.S. = FIRE SPRINKLED
G.T. = '>' GREATER THAN
OCCUPANCY ANALYSIS NOTES:
ADD ENTIRE SHEET
No. Revisions: Date:
1 REVIEW COMMENTS 2018-07-18
UP
UP
1. WHERE ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, OR OTHER ITEMS ARE RECESSED IN FIRE
RATED FIXTURES, WALLS OR PARTITIONS, LINE THE BACK AND SIDES OF THE WALL AND RECESS WITH
GYPSUM WALL BOARD TO MAINTAIN FIRE-RESISTIVE CONSTRUCTION OF THE WALL.
2. THE CONTRACTOR SHALL COORDINATE ALL TRADES FOR ALL OPENINGS THROUGH NEW OR
EXISTING CONSTRUCTION FOR DUCTS, PIPES, CONDUITS, CABINETS, AND EQUIPMENT. VERIFY
SIZES, AND LOCATIONS.
3. USE APPROVED FIRESTOP SLEEVES, AND SEALANTS WHERE PIPES, DUCTS, CONDUITS, OR OTHER
SYSTEMS PENETRATE FIRE OR SMOKE-RESISTIVE WALLS.
4. PACK MINERAL FIBER INSULATION AROUND PIPES, CONDUITS, DUCTS, OR OTHER EQUIPMENT THAT
PENETRATE NON-RATED PARTITIONS.
5. VERIFY ALL ROUGH-IN DIMENSIONS, AND SERVICE CONNECTION REQUIREMENTS FOR OWNER-
FURNISHED EQUIPMENT, AND EQUIPMENT INCLUDED IN THIS CONTRACT.
6. ALL TRADES WORKING CONCURRENTLY TOGETHER WHICH ARE INTERDEPENDENT INSTALLATIONS
SHALL COORDINATE AND SEQUENCE THEIR INSTALLATIONS TO FACILITATE THE TIMELY
INSTALLATION OF BOTH TRADES.
7. ALL TRADES SHALL REPORT DEFECTIVE CONDITIONS OF OTHER WORK INTENDED TO SUPPORT
THEIR INSTALLATION 5 WORKING DAYS PRIOR TO THEIR SCHEDULED START DATE.
8. NEW MATERIALS, EQUIPMENT, ASSEMBLIES, COMPONENTS, ACCESSORIES, ETC. SHALL MATCH &
CONFORM TO THE SAME PRODUCTS IN THE EXISTING FACILITY AS DEFINED IN THE OWNER'S
'MAINTENANCE & OPERATIONS' STANDARD TO ASSURE UNIFORMITY, INTERCHANGEABILITY, AND
COMPATIBILITY WITH AND BETWEEN EXISTING AND NEW.
9. ALL EXISTING AND NEW PENETRATIONS THROUGH NON-RATED WALL MEMBRANES, ABOVE
CEILINGS, SHALL BE SEALED WITH DRYWALL TAPE AND MUD, AIR TIGHT, BOTH SIDES OF WALL. AT
VISUALLY EXPOSED FACES WHERE NO CEILING IS PRESENT FINISH AND PAINT ADJACENT SURFACE
TO MATCH EXISTING OR AS SCHEDULED FOR NEW WORK.
10. PER IBC 2012, 703.7 FIRE BARRIERS, SMOKE BARRIERS, AND SMOKE PARTITIONS SHALL BE
PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN THE CONCEALED SPACE. SEE GENERAL
NOTES (FIRE ASSEMBLIES) HEREIN FOR ADDITIONAL INFO.
11. VERIFY ALL DIMENSIONS WITH MANUFACTURER.
GENERAL NOTES:
5 6 74.2 4.5 5.5 6.5 7.5 7.74
B
A.6
A
HR
HR
HR
HR
(E) GATE TO BE
RELOCATED -
COORDINATE
WITH COLUMN.
MODIFY GATE AND FENCE AS REQUIRED
TO FIT UNDER MEZZANINE STRUCTURE
PANELS = 10' X 15'
WITH 5'-0" DIVISIONS, TYP.
F1
AB211
20'-0"
2"X2" COLUMNS
@ 10'-0" O.C., TYP.
2"X2" COLUMNS
@ 10'-0" O.C., TYP.
± 2'-0" 7'-0"
4'-0" 2'-5 15/16"
VERIFY EXIST.
6'-2" 10'-0"
A.1
A.3
'-9
3/
6"
'-6
/2
8'
-0
2' -0
(E) (E) (E) (E)
(E)(E)(E)(E)
AL111
B7
AL111
B7
'-0
7'-0" 13'-0" 20'-0" 21'-0" 19'-0" 20'-0" 20'-0" 20'-0" 8'-0"
SAW CUT FLOOR, DEMO,
AND POUR BACK CONC.
FLOOR PER STRUCTURAL
PLANS, TYP. AT ALL NEW
T.S. COLUMNS
T.S. COLUMN, SEE
STRUCTURAL PLANS,
TYP.
EXISTING COLUMN, TYP.
FOR SECURITY GRILL, SEE
GENERAL NOTE A ON DRAWING
MH-111.
AREA FOR FUTURE
EQUIPMENT LIFT
(INFO TO BE
PROVIDED).
FREEZER
BOX TO
REMAIN
COORDINATE SAW CUT OF
FOOTING WITH FREEZER BOX
OVERHEAD DOOR
TO REMAIN
AL111
E7
OPENING IN FENCING FOR
CONVEYOR APPROX.
8" H x 24" FRAMED IN CHANNEL
SIMILAR TO EXISTING. FIELD
VERIFY WITH OWNER PRIOR
TO FABRICATING.
D5
AB211
5 6 74.2 4.5 5.5 6.5 7.5 7.74
B
A.6
A
+12'-0" AFF
1-1/8" T&G HARDWOOD PLYWOOD OVER STRUCT. STL. DECK.
INSTALL PANELS W/ A 4' STAGGERED OFFSET. SCREW TO STL.
DECK AT 6" O.C. AT PANEL EDGES AND 8" O.C. AT PANEL FIELD
WITH BUGLE HEAD SELF TAPPING SCREWS WITH SQUARE
DRIVE HEAD. COUNTERSINK SCREWS FLUSH TO THE 1/16" MAX
SO THAT HEADS ARE JUST BELOW THE FACE OF PLYWOOD.
PLYWOOD SHALL BE FINISHED EPOXY 80 MIL. THICK AS
FOLLOWS. FACE TO BE PLACED DOWN AGAINST DECK AND
UNEXPOSED EDGES SHALL BE COATED PRIOR TO
INSTALLATION. FACE TO BE PLACED UP/EXPOSED OR EDGES
THAT ARE EXPOSED SHALL BE COATED AFTER INSTALLATION.
JOINTS BETWEEN PANELS SHALL BE SEALED WITH A
POLYURETHANE SEALANT SUITABLE FOR PALLET JACK
LOADING TRAFFIC.
UTILITY CHASE TO 7'-0" AFF TYP. FIELD COORDINATE
LOCATION OF CHASES WITH REQUIRED UTILITY
RELOCATION AND NEW WORK
OPNG
3'-3 5/16"
O
PN
G
1' -8
/8
5.300
00 NA
5.300
00 NA
BOX OUT EXISTING
OVERHEAD DOOR
ASSEMBLY TO 7'-0" AFF
5' -0
8'
-0
0"
(N) 6' X 10' OPENING
(N) 42" HIGH OPENING
SAFETY BARRIER: MANUF. -
YELLOW GATE XL. VERIFY
MOUNTING
REQUIREMENTS WITH
MANUFACTURER.
3'-1" 3'-1"
VERIFY EXIST.
10'-0"
ROLLING GATE
BARNDOOR
CENTER GATE
SECTION ON EXISTING
LEVEL 1 ASILE
AREA FOR FUTURE
EQUIPMENT LIFT
(INFO TO BE
PROVIDED).
EXISTING HVAC PIPING TO
REMAIN AT 10' - 0" AFF
PROVIDE 14 G.A. BENT STEEL OPENING
PROTECTION INCLUDING HEAD.
F1
AB211
5.302
00 NA
GATE WITH BARN
DOOR HARDWARE
6'X10' CLEAR OPENING D3
AB211
TYP.
10'-0"
TYP.
10'-0" 6'-5 1/2" 3'-6 1/2" 10'-0" ± 6'-0"
MIN.
1'-0"
3'-0"
BELOW
D5
AB211
SIM.
A.1
A.3
AL111
B7
AL111
B7
(E) (E) (E) (E)
(E)(E)(E)(E)
5.300
00 NA
MEZZANINE CAGE
ENCLOSURE PER THE
IBC SECTION 505.2.3
(EXCEPTION 5), THE
MEZZANINE SHALL NOT
BE REQUIRED TO BE
OPEN TO THE ROOM IN
WHICH IT IS LOCATED
15'-0"
36" X 3" DIA. SCHEDULE 40
STEEL PIPE WELDED TO BEAM
BELOW. COORDINATE W/
STRUCTURAL. PROVIDE WELDED
CAP WITH 3/8" DIA. LOOP/ 1 1/2"
RADIUS WELDED TO TOP OF PIPE15'-5 3/4" +/-
/8
5.300
00 NA
AL111
D7
CHASE FOR EXISTING
FIRE RISER
1'-1 7/8"
/8
HR
HR
20 TREADS AT 11" AND 21 EQUAL
RISERS (APPROX. 6.86" EA.)
NOSING IN CONTRASTING
COLOR
GUARDRAIL
ON STRINGER
REQUIRED AREA OF LANDING
F5
AB211
4'-0" 18'-4" 4'-0"
3' -4
3/
4"
1/ 2"
1/
2" 2'
-6
/2
1/
2"
1/ 2"
3/
4"
MIN.
1'-0"
HANDRAIL EXTENSION, TYP.
WOOD DECKING PER STRUCTURAL
D5
AB211
SIM.
SAFETY BARRIER
TYPICAL, SEE
DETAIL F5/AB211
4.2
A
A.1
A.3
(E)
'-0
8' -0
EQ
EQ
9' -0
LIFT
PLATFORM
SEE SPEC
FOR SIZE
PROVIDE CAGE ENCLOSURE
BY MANUFACTURER
MIN 7'-0" HIGH. EXTEND TO WALL.
EQ
EQ
2'-8" X 2'-8" X 4" H
CONCRETE PAD
FOR LIFT MOTOR.
VERIFY SIZE WITH
MANUFACTURER.
CENTERLINE OF PIT/LIFT.
LIFT SUPPORTS IN PIT
PIT DEPTH 5"
MEZZANINE EXTENSION
ABOVE
1'-6".
1"
6'-6" PIT
SAW CUT FLOOR AS REQUIRED FOR
LIFT PIT. POUR NEW SLAB FOR SUPPORT.
SEE DETAIL 6/S201.
S201
NOTE: VERIFY ALL DIMENSIONS
WITHMANUFACTURER PRIOR TO
DEMO FOR PIT.
4.2
A
A.1
A.3
BOX OUT EXISTING
OVERHEAD DOOR
ASSEMBLY
5' -0
8'
-0
0"
(E)
5.300
00 NALIFT PLATFORM
LIFT SUPPORTS
CENTERLINE
OF LIFT
9' -0
PROVIDE CAGE ENCLOSURE
BY MANUFACTURER
MIN 7'-0" H ABOVE MEZZANINE
OPENING 8'-0" X 10'-0" IN EXISTING
GWB WITH METAL STUD WALL. PROVIDE
NEW HEADER PER STANDARD DETAILS.
CENTER OPENING ON LIFT.
PROVIDE 14 GA BENT STEEL
CORNER GUARD PROTECTION
INCLUDING HEAD OF OPENING
1'-6".
SCALE: 1/8" = 1'-0"F1
LEVEL 1 - FLOOR PLAN
SCALE: 1/8" = 1'-0"C1
MEZZANINE LEVEL PLAN
WALL SCHEDULE
MAR
K
CORE STRUCTURE
ASSEMBLY NOTES SPEC-REF
THERMAL PROPERTIES
ACOUSTIC
PROPERTIES FIRE CONTROL PROPERTIES
NOTESMATERIAL WIDTH SPACING R-VALUE U-VALUE INSULATORS
STC
RATING
TEST
STANDARD
RATING
(MINUTES) ASSEMBLY TEST STD
5.300 MS 3-5/8" 16" O.C. 3/4" PLYWD (ROOM SIDE) TO 8FT. PROVIDE
7GA. TYPE 304 STAINLESS STEEL CORNER
GUARDS TO 48" ABOVE FIN. FLOOR
07.21.16, 09.21.16, 09.22.13
0 0.00 00
5.302 MS 3-5/8" 16" O.C. 5/8" ABUSE RESISTANT GWB BOTH SIDES OF
WALL TO 6" ABV CEILING OR BTM OF
STRUCTURE WHEN EXPOSED. UNLESS NOTED
OTHERWISE.
09.21.16, 09.22.13
0 0.00 39 NRC#66 00
WALL LEGEND
ABV. = ABOVE
BTM = BOTTOM
CMU = CONCRETE MASONRY UNIT
U.N.O. = UNLESS NOTED OTHERWISE
HGT = HEIGHT
W/ = WITH
(E) = EXISTING
WS = WOOD STUD
MS = METAL STUD
GWB = GYPSUM WALL
BOARD
NR = NOT RATED
NA = NOT APPLICABLE
GENERAL NOTES
1. R-VALUE REPRESENTS THE TOTAL COMPOSITE WALL
ASSEMBLY FOR BOTH IMMEDIATELY ADJACENT WALLS.
2. WALL TAGS INDICATING AN STC VALUE WITH 'C' SHALL
COMPLY WITH THE ACOUSTICAL WALL ASSEMBLY NOTES.
3. COORDINATE WITH STRUCTURAL DRAWINGS FOR
EXTERIOR WALL METAL STUD GAUGE.
NOTES - WALL SCHEDULE
1. R-VALUE REPRESENTS THE TOTAL COMPOSITE WALL
ASSEMBLY FOR BOTH IMMEDIATELY ADJACENT WALLS.
2. WALL TAGS INDICATING AN STC VALUE WITH 'C' SHALL
COMPLY WITH THE ACOUSTICAL WALL ASSEMBLY NOTES.
3. COORDINATE WITH STRUCTURAL DRAWINGS FOR
EXTERIOR WALL METAL STUD GAUGE.
SCALE: 1/4" = 1'-0"B7
LEVEL 1 - ENLARGED STAIR PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering Discipline: A/E:
C U s e rs
\s k e s s le r\ D o c u m e n ts
\1
.0
V
A T u c s o n
C M
O P
S to ra g e M e z z a n in e
A
R C
H
(R s k e s s le r_ G
L H
N .r v t
/6
/2
:0
:2
P M
AL111
FLOOR & MEZZANINE PLANS
Turner Structural Engineering
3026 N. Country Club
Tucson, AZ 85716
(520) 323-3422
Jim Hart
Tucson CMOP Storage Mezzanine
3675 E. Brittania Dr., Tucson, AZ
762-18-01
Project Director
August 07, 2018 BH SK/EP
100% CONSTRUCTION
DOCUMENTS
GLHN Architects & Engineers, Inc.
2939 E. Broadway Blvd.
Tucson, AZ 85716
(520) 881-4546
Ted Moeller
GLHN PROJECT # 17073.00
SCALE: 1/4" = 1'-0"E7
LIFT ENLARGED PLAN
SCALE: 1/4" = 1'-0"D7
LIFT ENLARGED PLAN AT MEZZANINE
FUTURE EQUIPMENT LIFT WILL
BE A DEFERRED SUBMITTAL (PER
THE 2012 IBC SECTION 1407.3.4.1),
OR WILL REQUIRE A NEW PERMIT.
FUTURE EQUIPMENT LIFT WILL
BE A DEFERRED SUBMITTAL (PER
THE 2012 IBC SECTION 1407.3.4.1),
OR WILL REQUIRE A NEW PERMIT.
1ST FLOOR
0' - 0"
MEZZANINE LEVEL
12' - 0"
5 6 74.2 4.5 5.5 6.5 7.5 7.74 F1
AB211
/2
/2
M O
D
IF
IE
D
ST
A
N D
A R
D
M O
D
IF
IE
D
/2
ST
A
N D
A R
D
PANEL WIDTH
10'-0" TYP.
PANEL WIDTH
10'-0" TYP.
PANEL WIDTH
10'-0" TYP.
PANEL WIDTH
3'-6 1/2" MODIFIED
PANEL WIDTH
6'-5 1/2" MODIFIED
FIELD COORDINATE ALL
MODIFIED PANELS AS
NECESSARY TO REUSE
EXISTING PANELS
CAGE PANELS, MODIFY
EXISTING AS NECESSARY
2"X2" T.S. VERTICAL POSTS,
TYP., REUSE EXISTING
WHERE POSSIBLE, FIELD
COORDINATE EXTENT
EXISTING TRUSSES
TO REMAIN
NEW STEEL STAIRS NEW MEZZANINE STRUCTURE,
REF. STRUCTURAL PLANS, TYP.
EXISTING CAGE
PANELS, TO BE
MODIFIED AND
REINSTALLED, TYP.
NEW STEEL STAIRS
EXISTING WALL
PER PLAN, TYP.
AB211
C1
AB211
D1
BARN DOOR ROLLING
GATE PER PLAN.
OMIT GUARDRAIL
AT OPENING. SEE THE
FOLLOWING VIEWS:
FALL PROTECTION
OVERHEAD CONNECTION
SEE DETAIL
PROVIDE
7'-0" L X 2" X 2" CHANNEL ON
LATCH SIDE OF GATE. FOR
GATE SUPPORT IN CLOSED.
COORDINATE WITH GATE
FRAME DIMENSIONS.
/D5 AB211
/E7 AB211
/D7 AB211
/B7 AB211
1-1/2" O.D.
GUARDRAIL PIPE,
CENTERED OVER
TOP OF STRINGER
1-1/2" O.D. HANDRAIL
HOLD 2" CLR FROM
FACE OF GUARDRAIL
1-1/2" O.D. GUARDRAIL
PIPE CENTERED OVER
TOP OF STRINGER
HANDRAIL TO
EXTEND TO FLOOR
1/2" O.D. STL BENT
BAR.
STL. STAIR PER
STRUCT. DETAILS
1' - 3"
1' - 0" MIN.
1' - 4"
1' - 4"
(2) 1/2" DIA X 4" LONG
EXPANSION ANCHORS
EQ. OF HILTI -KB3 (TYP
BOTH STRINGERS)
POST TO
STRINGER 1/4
2-1/2"X6"X1/4" STEEL
PLATE WITH 1/2" EPOXY
BOLT EA. SIDE
POST TO
PLATE 1/4
M
IN
SWINGING SAFETY
BARRIER. MANUF. -
"YELLOW GATE."
MOUNT TO
VERTICAL POST PER
MANUFACTURER
REQUIREMENTS OR
APPROVED EQUAL.
MANUFACTURER
CONTACT:
PH: 888.878.1839
YELLOWGATE.COM
3" MIN. IMBED
DEPTH
MEZZANINE LEVEL
12' - 0"
STEEL STAIR PER
STRUCTURAL PLANS
RETURN HANDRAIL TO
WALL (OR POST AT SIM.)
M
IN
WALL BEYOND
1-1/2" O.D. HANDRAIL
HOLD 2" CLR FROM
FACE OF GUARDRAIL
1-1/2" O.D. GUARDRAIL
PIPE CENTERED OVER
TOP OF STRINGER, REF.
DTL. /F5 AB211
3 3/4"8 1/4"
MIN.
1'-0"
1ST FLOOR
0' - 0"
T.O. ROOF
28' - 0"
MEZZANINE LEVEL
12' - 0"
A.6
AB211
F3
OPEN ABOVE 10'-0"
ATTACH TO SIDE OF TRUSS
PER EXISTING DETAILS
RELOCATED POSTS/CAGE AT
MEZZANINE LEVEL, WELD
EXTENTION TO MATCH
EXISTING AS NECESSARY UP
TO TRUSS SPACE
EXISTING CAGE ENCLOSURE,
MODIFY AND REINSTALL
CAGE PANELS TYP. AT
MEZZANINE ENCLOSURE,
MODIFY EXISTING PANELS TO
HEIGHT AS NOTED
CONTINUOUS ENCLOSURE
PANEL, TYP.
/2
/2
2'-6" X 10'-0"
CAGE PANEL
(HALF OF
STANDARD 5' X
10' PANEL)
STANDARD
5' X 10'
PANEL
-1
/2
M O
D
IF
IE
D
ST
A
N D
A R
D
M O
D
IF
IE
D
ST
A
N D
A R
D
AB211
E9
MEZZANINE LEVEL
12' - 0"
A.6
6X6X1/4" STL. ANGLE, WELD TO TOP
OF BEAM PER STRUCTURAL PLANS
WOOD DECKING OVER METAL DECK
PER STRUCTURAL PLANS
CAGE ENCLOSURE PANELS WITH
2"X2" POSTS, MODIFIED TO
SURROUND MEZZANINE PER PLAN
± 1'-8" 2'-5 121/128"
MODIFY AND REINSTALL EXISTING
CAGE ENCLOSURE TO BOTTOM OF
NEW BEAMS
18 GA DIAMOND PLATE MESH TACK
WELD CONT. TO BACK OF ANGLES
POST TO
BEAM1/4
3"+/- AS REQUIRED FOR CAGE
SUPPORT BASE PLATE
GUARDRAIL WELDED TO STEEL
ANGLES
1 1/2" X 1 1/2" X 4" L
WELDED TO BOTTOM
FLANGE
1 1/2" X 1 1/2" CONT. STEEL ANGLES
WELDED TO DECK AND TOP OF BEAM
PROVIDE 2 EA. 3/8" SELF TAPPING
SCREWS THROUGH DECK INTO
PERIMETER ANGLES MIN 1/2"
SEE ALSO PLAN NOTE
ON /F1 AL111
STEEL BEAM.
SEE STRUCT. TYP.
MEZZANINE LEVEL
12' - 0"
5.5
1/4" STL. PLATE SCREWED
TO BOTTOM OF DECK
POST TO
PLATE1/4
SIDE AND TOP OF
COOLER BEYOND
STL. STRUCTURE PER
STRUCTURAL PLANS
10'-0" A.F.F.
VERIFY EXIST.
2"X2" EXIST. STL. POST, MODIFY AS
NEEDED TO ATTACH TO BOTTOM
OF DECK
/8
/8
EXIST. STL. CAGE PANELS, MODIFY
AS NECESSARY TO REDUCE HEIGHT,
SALVAGE UPPER PORTION FOR
REUSE ON NEW MEZZANINE
WOOD DECKING ON METAL
DECK PER STRUCTURAL PLANS
18 GA DIAMOND
PLATE MESH TACK
WELD CONT. TO
TOP, SIDES AND,
BOTTOM
1"X1/2""X1/8" STL. ANGLE, CONTINUOUS
FILLET WELD EA. END TO POSTS
OTHER HALF USE FOR
ADDITIONAL PANELS
MODIFY MID-SPAN RAIL
AS NECESSARY, TYP.
NEW CHANNEL FRAME
TO MATCH EXISTING,
WELD MESH TO
CHANNEL, PAINT TO
MATCH
CUT PANEL IN HALF.
MODIFY TO CREATE
TWO 2'-6" x 10'-0"
PANELS
10'-0"
EXISTING 2X2
COLUMN, TYP.
EXISTING MID-
SPAN RAIL, TYP.
ATTACHMENT
BRACKET WITH 2
BOLTS TO FLOOR
HD CAGE PANEL,
TYP. 5' X 10'
P A
N E L
10'-0" PANEL
TYPICAL 5'X10'
PANEL
EXISTING CAGE PANEL - CLOSE UP
EXISTING CAGE PANEL
TYPICAL 5'X10'
PANEL
5'-0" MAX.
EQ
EQ
M
IN
FINISHED
FLOOR
1 1/2" O.D.
CONTINUOUS
TOP RAIL
1 1/2" O.D.
RAILS
FINISHED FLOOR
1 1/2" CONTINUOUS
RAIL, TYP.
FRAMING, SEE
STRUCTURAL
REVISED
FENCING
LOCATION
EQ
EQ
M
IN
3/8" FASTENER
MUST BE
SECURE
TO STEEL POST
400 LB BOX RAIL
TRACK
400 LB TROLLEY
ASSEMBLY
400 LB SIDE
MOUNT
BRACKET
1/2" PENDANT BOLT;
1" MAX VERTICAL
ADJUSTMENT
STEEL FENCE GATE
FABRICATE FROM
FENCING
RELOCATED
POST
BOLTS - MATCH
EXISTING SIZE
STEEL FENCE GATE
FABRICATE FROM
FENCING
30" O.C.
BRACKET SPACING
PADDED
ADJUSTABLE
END STOP
3/8" FASTENER
MUST BE
SECURE
TO STEEL POST
400 LB BOX RAIL
TRACK
400 LB TROLLEY
ASSEMBLY
400 LB SIDE
MOUNT
BRACKET
1/2" PENDANT BOLT;
1" MAX VERTICAL
ADJUSTMENT
STEEL FENCE GATE
FABRICATE FROM
FENCING
POST BEYOND
BOLTS - MATCH
EXISTING SIZE
2" X 4" TUBE STEEL
HEADER BETWEEN
2" X 2" POSTS, WELD
TO POSTS.
PROVIDE MIN.
2 CLIPS EQ.
BETWEEN
COLUMNS
SCALE: 1/8" = 1'-0"B1
INTERIOR ELEVATION
SCALE: 1" = 1'-0"F5
DETAIL - STAIR BASE LANDING - 02
SCALE: 1" = 1'-0"D5
STAIR TOP LANDING
SCALE: 1/4" = 1'-0"F1
WALL SECTION - EDGE OF MEZZANINE
SCALE: 1" = 1'-0"F3
MEZZANINE EDGE
SCALE: 1" = 1'-0"D3
CAGE EXTENSION - LEVEL 1
SCALE: 1/4" = 1'-0"C1
EXISTING PANEL MODIFIED MEZZANINE
SCALE: 1/4" = 1'-0"D1
EXISTING PANEL TYPICAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering Discipline: A/E:
C U s e rs
\s k e s s le r\ D o c u m e n ts
\1
.0
V
A T u c s o n
C M
O P
S to ra g e M e z z a n in e
A
R C
H
(R s k e s s le r_ G
L H
N .r v t
/6
/2
:0
:2
P M
AB211
BUILDING ELEVATIONS - INTERIOR
Turner Structural Engineering
3026 N. Country Club
Tucson, AZ 85716
(520) 323-3422
Jim Hart
Tucson CMOP Storage Mezzanine
3675 E. Brittania Dr., Tucson, AZ
762-18-01
Project Director
August 07, 2018 BH SK/EP
100% CONSTRUCTION
DOCUMENTS
GLHN Architects & Engineers, Inc.
2939 E. Broadway Blvd.
Tucson, AZ 85716
(520) 881-4546
Ted Moeller
GLHN PROJECT # 17073.00
GUARDRAIL
SEE
GUARDRAIL
SCALE: 1" = 1'-0"F8
TYPICAL GUARDRAIL ELEVATION
SCALE: 1" = 1'-0"E9
TYPICAL GUARDRAIL
SCALE: 3" = 1'-0"D7
BARN DOOR HARDWARE SECTION
SCALE: 3" = 1'-0"E7
BARN DOOR HARDWARE FRONT VIEW
SCALE: 3" = 1'-0"B7
BARN DOOR HARDWARE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GLHN Architects & Engineers, Inc.
2939 E. Broadway Blvd.
Tucson, AZ, 85716
(520) 881-4546 Ted Moeller
Engineering Discipline:
Turner Structural Engineering Company 3026 N. Country Club Tucson, AZ, 85716
(520) 323-3422 Jim Hart
Tucson CMOP Storage Mezzanine
3675 E. Brittania Dr. Tucson, AZ
762-18-01
Project Director
June 14, 2018Revisions: Date: GLHN Project No. 17073.00 MLH PMF M001
SPECIFICATIONS
MECHANICAL
GENERAL CODE AND STANDARDS COMPLIANCE
ALL WORK MUST COMPY WITH THE 2012 INTERNATIONAL BUILDING CODES WITH THE…
This is the start of the file's text. The full file is on GovTribe.