A_E Design Narrative_Final.pdf

PDF 10 MB Posted

Attached to
Z1DA--Paint Buildings, Exterior Construction (SAVAHCS)
Solicitation number
36C26222R0089
Issued by

About this file

This document provides details on a federal contract opportunity for exterior painting services at a Veterans Affairs medical center. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 is soliciting bids under solicitation number 36C26222R0089 to paint buildings at the Savannah VA Coastal Health Care System campus. Interested vendors are advised that the previous solicitation number for this project was changed from RFI 36C26222Q0487 to the listed RFP number, with bids due to open for submission on or around April 15, 2022. The scope of work involves exterior construction and painting services to update the appearance of buildings at the VA medical facility located in Savannah, Georgia.

View the file

Other files

File Type Posted
BLDG 9 DRAWINGS AND PHOTOS.pdf PDF
BLDG 11 DRAWINGS AND PHOTOS.pdf PDF
fw9.pdf PDF
BLDG 90 DRAWINGS AND PHOTOS.pdf PDF
BLDG 8 DRAWINGS AND PHOTOS.pdf PDF
Specifications Final.pdf PDF
VA10091.pdf PDF
36C26222R0089.docx DOCX document
BLDG 7 DRAWINGS AND PHOTOS.pdf PDF
BLDG 94 DRAWINGS AND PHOTOS.pdf PDF
BLDG 2 DRAWINGS AND PHOTOS.pdf PDF
BLDG 57 DRAWINGS AND PHOTOS.pdf PDF
BLDG 12 DRAWINGS AND PHOTOS.pdf PDF
BLDG 13 DRAWINGS AND PHOTOS.pdf PDF
36C26222R0089_2.docx DOCX document
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

o o o o o o o o o o o o o o o o o o o o

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com 337-2468

04/19 (10/18)

SOLVENT TYPE: Waterborne RESIN TYPE: 100% acrylic

FINISH (ASTM D 523): Flat: 1.5–2.5% on a 60º meter; Less than 2.0% on an 85º meter

COLORS: All colors can be special ordered or store mixed.

TINT BASES: L Tintable White, M Medium, U Ultra Deep

VISCOSITY@77ºF/25ºC (ASTM D 562): 100–110 KU

MAXIMUM VOC CONTENT

40 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 20 g/L

SOLIDS BY VOLUME (ASTM D 2697)

39.5% ± 2%

SOLIDS BY WEIGHT

54.0% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 11.20 lbs.

COMPOSITION BY WEIGHT

Pigment–38.2% *Prime pigments ................................14.7 Reinforcing pigments ........................23.5

Vehicle–61.8% Acrylic resins .....................14.0 Water & additives ..............47.8

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 3.9 mils Dry: 1.5 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 350–400 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If necessary to maintain good workability, add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 1–2 hours Recoat: 4–6 hours Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING: One-gallon, five-gallon containers

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2016; MPI Approved Product #10, #16

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800-424-LEAD, or log onto www. epa.gov/lead or/ asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• If efflorescence exists, remove all noticeable deposits and prime the entire surface with SUPER-LOC® Premium (SLPRA00/SLPRB00), EFF-STOP®

Premium (ESPR00) or EFF-STOP® Select (ESSL00).

• Certain woods, such as redwood, cedar, and spruce, contain water-soluble extracts (tannins) that may discolor lighter colors. In these situations, it is recommended to prime the wood with EZ-PRIME® Premium (EZPR00) before applying ACRI-HUES® Flat (ACHS10).

• For best results, use airless spray application.

• When the air temperature is at 35ºF, substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 35ºF and at least 5ºF above the dew point. Avoid using if rain or snow is expected within 2-3 hours, as in colder temperatures, it may require longer time before the paint film cures enough not to be affected by rain or snow. Do not apply at air or surface temperatures below 35ºF or when air or surface temperatures may drop below 35ºF within 48 hours.

• Standard latex primers cannot be used below 50ºF. See the specific primer product information sheet for that product’s application conditions.

PRIMERS

MASONRY

Plaster:

Tilt-up concrete:

Poured-in-place:

Brick:

EFF-STOP® Premium (ESPR00), EFF-STOP® Select (ESSL00) or FLEX-PRIME® Select (FPSL00)

Concrete block: Smooth BLOCFIL Premium (SBPR00), Smooth BLOCFIL Select (SBSL00) or FLEX-PRIME® Select (FPSL00)

WOOD

Trim, sash, fascia:

T1-11 siding: EZ-PRIME® Premium (EZPR00)

Rough-sawn: Must prime to use on wood

SYNTHETIC WOOD

Masonite:

Hardboard:

MDO siding:

ULTRA-GRIP® Premium (UGPR00) or ULTRA-GRIP® Select (UGSL00)

METAL

Ferrous: BLOC-RUST® Premium (BRPR00) or ENDURAPRIME™ Metal Primer (ENPR00)

Non-ferrous: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or BLOC-RUST® Premium (BRPR00)

Galvanized steel: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or *ULTRA-GRIP® Premium (UGPR00)

*for incidental use on galvanized

DESCRIPTION: ACRI-HUES® Flat is a professional exterior, ultra-low VOC, 100% acrylic flat paint. It is ideal for use on a wide range of residential and commercial projects. ACRI-HUES Flat provides very good hide and durability and can be used on properly prepared and primed masonry, concrete block, tilt-up, stucco, and metal. It can be used as a solid color stain on new or previously painted rough-sawn wood. Can be used down to surface and air temperature of 35ºF.

PRODUCT INFORMATION

ACRI-HUES®

Exterior Flat Paint

ACHS10

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

10/19 (02/19)

SOLVENT TYPE: Waterborne RESIN TYPE: Waterborne urethane alkyd

FINISH (ASTM D 523): Semi-Gloss: 65–80% on a 60º meter after 14 days.

COLORS: Stock colors: Black, Swiss Coffee. Other colors, as well as 6 OSHA safety colors, can be special ordered or store mixed.

TINT BASES: L Tintable White, M Medium, U Ultra Deep

VISCOSITY@77ºF/25ºC (ASTM D 562): 95–105 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 50 g/L

SOLIDS BY VOLUME (ASTM D 2697)

37.2% ± 2%

SOLIDS BY WEIGHT

52.0% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 10.85 lbs.

COMPOSITION BY WEIGHT

Pigment–26.7% *Prime pigments ................................26.7 Reinforcing pigments ...........................0.0

Vehicle–73.3% Resins................................23.6 Water & additives ..............49.7

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 4.0 mils Dry: 1.5 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 325–375 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 45-90 minutes Recoat: After 4-6 hours* ickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING:

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2016; CA Section 01350; LEED 2009 IEQ Credit 4.2; LEED v4 EQ Credit 2; MPI Approved Product #169; CRGI

FDA Guidelines for Resinous & Polymeric Coatings SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPAs National Lead Information Hotline at 1-800-424-LEAD, or visit www.

epa.gov/lead or /asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• Do not apply when the air or surface temperature is below 50ºF.

PRIMERS

DRYWALL

Textured:

Untextured:

Skim-coated:

VINYLASTIC® Premium (VNPR00)

MASONRY

Plaster:

Tilt-up concrete:

Poured-in-place:

Brick:

EFF-STOP® Premium (ESPR00)

Concrete block: Medium BLOCFIL™ Premium (MBPR00), Smooth BLOCFIL™ Premium (SBPR00) or Smooth BLOCFIL™ Select (SBSL00)

Smooth trowel: SUPER-LOC® Premium (SLPR00)

WOOD

Doors, trim: INTER-KOTE® Premium (IKPR00), ULTRA-GRIP® Premium (UGPR00) BLOCK-IT® Premium (BIPR00) or EZ-PRIME® Premium (EZPR00) – EXTERIOR ONLY

SYNTHETIC WOOD

Masonite:

Hardboard:

INTER-KOTE® Premium (IKPR00), ULTRA-GRIP® Premium (UGPR00) or BLOCK-IT® Premium (BIPR00)

METAL

Ferrous: BLOC-RUST® Premium (BRPR00) or

ENDURAPRIME™ Metal Primer (ENPR00)

Non-ferrous: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or BLOC-RUST® Premium (BRPR00)

Galvanized steel: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or *ULTRA-GRIP® Premium (UGPR00)

≤ 50 g/L VOC**

DESCRIPTION: ARISTOSHIELD® Semi-Gloss is an ultra-premium interior/exterior ultra-low VOC enamel formulated with advanced water-superior performance and durability are required on doors, trim, cabinets, as well as metal surfaces such as wrought iron, garage doors, hand rails, and metal doors.

PRODUCT INFORMATION

ARISTOSHIELD®

Interior/Exterior Semi-Gloss Paint

ASHL50

*for incidental use on galvanized

1DTM (Direct to Metal): ARISTOSHIELD can be used as a direct to metal coating on properly prepared steel surfaces by applying two (2) coats of ARISTOSHIELD.

Note: for best corrosion protection, one (1) coat of BLOC-RUST Premium primer and two (2) coats of ARISTOSHIELD topcoat are recommended.

an international paint industr redited testing laboratory, to meet performance and environmental standards as shown on www.gr

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

4/18 (7/16)

SOLVENT TYPE: Water RESIN TYPE: Waterborne alkyd

FINISH (ASTM D 523): 10–17% on a 60º meter

COLORS: BLOC-RUST Premium may be tinted with up to 2 fl. oz. of Dunn- Edwards ZTC Zero VOC colorant per gallon.

VISCOSITY@77ºF/25ºC (ASTM D 562): 97–103 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 40 g/L

SOLIDS BY VOLUME (ASTM D 2697)

40.9% ± 2%

SOLIDS BY WEIGHT

53.9% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 10.66 lbs.

COMPOSITION BY WEIGHT

Pigment–25.3% *Prime pigments ................................15.0 Reinforcing pigments ........................10.3

Vehicle–74.7% Alkyd resins .......................26.7 Water & additives ..............48.0

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 4.9 mils Dry: 2.0 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 275–325 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If necessary to maintain good workability, add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 1–2 hours Recoat: After 4 hours Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING: Quart, one-gallon, five-gallon containers

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2013; CHPS Section 01350;

LEED 2009 IEQ Credit 4.2; LEED v4 EQ Credit 2; CRGI Green Wise Certified

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800-424-LEAD, or visit www.

epa.gov/lead or /asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• BLOC-RUST® Premium can be used on bare ferrous metal surfaces (interior and exterior) provided they are free of rust, mill scale, and other contaminants.

Before any surface preparation is attempted, oil and grease must be removed by employing SSPC-SP1 Solvent Cleaning. Use SSPC-SP6 Commercial Blast Cleaning or SSPC-SP11 Power Tool Cleaning to bare metal to remove mill scale, rust, or other contaminants and to leave a roughened surface.

Sandblasted or newly cleaned metal must be prime-coated the same day to prevent re-contamination.

• BLOC-RUST® Premium must be recoated within 7 days to ensure proper adhesion of the finish coat.

• A minimum of 2 mils dry film is required on clean ferrous metal surfaces for adequate corrosion resistance. Additional dry film build may be necessary depending on surface and/or exposure conditions. For severe exposure conditions, apply two coats of BLOC-RUST® Premium for best corrosion protection.

• BLOC-RUST® Premium Red Oxide (BRPR00-2-RO) is the recommended first coat under darker color topcoats.

• Do not apply when the relative humidity is above 80% during the first 24 hours of drying, as this can impact the performance of the primer.

• Do not apply when the air or surface temperature is below 50ºF.

USE AS A PRIMER FOR

METAL

Ferrous: BLOC-RUST® Premium White (BRPR00-WH) or

BLOC-RUST® Premium Red Oxide (BRPR00-RO) Non-ferrous: BLOC-RUST® Premium White (BRPR00-2-WH) or

BLOC-RUST® Premium Red Oxide (BRPR00-RO) Galvanized steel: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or

ULTRA-GRIP® Premium (UGPR00)

DESCRIPTION: BLOC-RUST® Premium White is a Rust Preventative primer that offers excellent corrosion resistance and adhesion on interior and exterior ferrous and non-ferrous metals, except for galvanized steel. It is formulated with advanced waterborne alkyd technology to provide superior application properties and good hide, with the convenience of lower odor, fast drying, and water cleanup. FOR METAL

SUBSTRATES ONLY.

PRODUCT INFORMATION

BLOC-RUST® Premium Interior/Exterior Rust Preventative Metal Primer

BRPR00-2-WH WHITE

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

7/18 (4/18)

SOLVENT TYPE: Waterborne RESIN TYPE: 100% acrylic

FINISH (ASTM D 523): Flat: 4.0–5.0% on a 60º meter; 5.0–10.0% on an 85º meter

COLORS: Available in tint bases: L Tintable White, M Medium, U Ultra Deep

VISCOSITY@77ºF/25ºC (ASTM D 562): 125–140 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 25 g/L

SOLIDS BY VOLUME (ASTM D 2697)

50.1% ± 2%

SOLIDS BY WEIGHT

63.8% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 11.47 lbs.

COMPOSITION BY WEIGHT

Pigment–38.2% *Prime pigments ..................................8.3 Reinforcing pigments ........................29.9

Vehicle–61.8% Acrylic resins .........................24.0 Water & additives ..................37.8

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS (see Special Instructions) Wet: 22-26 mils Dry: 11-13 mils

PERFORMANCE SPECIFICATIONS

Tensile Strength: 215 PSI Elongation: 330%

Wind Driven Rain: PASS Permeability: 13.0

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 25–75 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 60 minutes Recoat: 24 hours Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray (see Special Instructions)

PACKAGING: Five-gallon container

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2013

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800-424-LEAD, or log onto www. epa.gov/lead or/asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• If efflorescence exists, remove all noticeable deposits and prime the entire surface with SUPER-LOC® Premium (SLPR00), EFF-STOP® Select (ESSL00) or FLEX-PRIME® Select (FPSL00).

• For wood application, prime with EZ-PRIME® Premium (EZPR00) and then apply two coats of ENDURALASTIC® Elastomeric Wall Coating (EDLX10-0) at a maximum dry film thickness of 1.5 to 3.0 mils per coat. Add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating. Do not apply at the recommended dry film thickness for masonry of 11-13 mils, as it can create moisture related issues.

• Certain woods, such as redwood, cedar, and spruce, contain water-soluble extracts (tannins) that may discolor lighter colors. In these situations, it is recommended to prime the wood with EZ-PRIME® Premium (EZPR00) before applying ENDURALASTIC® Elastomeric Wall Coating (EDLX10-0).

• Airless spray application of ENDURALASTIC 10 must be “pinhole-free” and have a dry film thickness of 11–13 mils. Surface features mandate the method of application and number of coats needed to achieve this.

• Do not thin or reduce.

• Do not apply when the air or surface temperature is below 50ºF.

WARNING: This product can expose you to benzophenone, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

PRIMERS

MASONRY

Plaster:

Stucco (new):

Stucco (repaint):

Tilt-up concrete:

Poured-in-place:

Brick:

Smooth trowel:

SUPER-LOC® Premium (SLPR00), EFF-STOP® Select (ESSL00)or FLEX-PRIME® Select (FPSL00)

Concrete block: Smooth BLOCFIL Premium (SBPR00) or Smooth BLOCFIL Select (SBSL00)

DESCRIPTION: ENDURALASTIC® 10 is an ultra-premium specialty 100% acrylic elastomeric wall coating designed for use on exterior surfaces. ENDURALASTIC 10 has exceptional flexibility, chalking and dirt pick-up resistance, bridges hairline cracks, and provides outstanding waterproofing protection against wind-driven rain. ENDURALASTIC 10 also provides excellent adhesion and outstanding alkali and efflorescence resistance on properly prepared masonry.

PRODUCT INFORMATION

ENDURALASTIC® 10

Elastomeric Wall Coating

EDLX10-0A

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

6/16 (8/15)

SOLVENT TYPE: Water RESIN TYPE: Acrylic/Epoxy

FINISH (ASTM D 523): 2–8% on a 60º meter

COLORS: White. EFF-STOP Premium may be tinted with up to 2 fl. oz. of Dunn- Edwards ZTC Zero VOC colorant per gallon.

VISCOSITY@77ºF/25ºC (ASTM D 562): 93–101 KU

MAXIMUM VOC CONTENT

20 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 5 g/L

SOLIDS BY VOLUME (ASTM D 2697)

36.0.0% ± 2%

SOLIDS BY WEIGHT

49.0.0% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 10.78 lbs.

COMPOSITION BY WEIGHT

Pigment–33.8% *Prime pigments ................................10.2 Reinforcing pigments ........................23.6

Vehicle–66.2% Acrylic & epoxy resins .......12.7 Water & additives ..............53.5

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 5.5 mils Dry: 2.0 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 225–275 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If necessary to maintain good workability, add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 30–60 minutes Recoat: 2–4 hours Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING: One-gallon, five-gallon containers

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2013; CHPS Section 01350;

LEED 2009 IEQ Credit 4.2; LEED v4 EQ Credit 2; MPI Approved Product #3, #50;

CRGI Green Wise Certified; FDA Guidelines for Resinous & Polymeric Coatings

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800-424-LEAD, or visit www.

epa.gov/lead or /asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• New concrete should be allowed to cure for at least 14 days before applying EFF-STOP® Premium.

• Do not apply when the air or surface temperature is below 50ºF.

USE AS A PRIMER FOR

MASONRY

Plaster:

Brick:

SUPER-LOC® Premium (SLPR00) or EFF-STOP® Premium (ESPR00)

Stucco:

Tilt-up concrete:

Poured-in-place:

EFF-STOP® Premium (ESPR00)

Concrete block: Smooth BLOCFIL Premium (SBPR00) Smooth trowel: SUPER-LOC® Premium (SLPR00)

DESCRIPTION: EFF-STOP® Premium iis an epoxy-fortified acrylic primer/sealer for interior and exterior masonry. EFF-STOP Premium provides excellent adhesion, and efflorescence and alkali resistance on above grade masonry surfaces, tilt-up concrete, stucco and block.

It can be applied to masonry surfaces with a pH level up to 13. Masonry surfaces must cure for a minimum of 7 days. Avoid using alkali sensitive colors.

PRODUCT INFORMATION

EFF-STOP® Premium Interior/Exterior Masonry Primer/Sealer

ESPR00-1

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT® I dunnedwards.com

03/19 (12/18)

SOLVENT TYPE: Waterborne RESIN TYPE: 100% acrylic

FINISH (ASTM D 523): Semi-Gloss: 40–50% on a 60º meter

COLORS: Stock colors: Swiss Coffee, Black and Whisper.

TINT BASES: L Tintable White, M Medium, U Ultra Deep

VISCOSITY@77ºF/25ºC (ASTM D 562): 93–98 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 30 g/L

SOLIDS BY VOLUME (ASTM D 2697)

37.9% ± 2%

SOLIDS BY WEIGHT

48.9% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 10.37 lbs.

COMPOSITION BY WEIGHT

Pigment–24.2% *Prime pigments ................................22.9 Reinforcing pigments ...........................1.3

Vehicle–75.8% Acrylic resins .....................21.1 Water & additives ..............54.7

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 4.0 mils Dry: 1.5 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 350–400 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 1–2 hours Recoat: 6–8 hours

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING:

STORAGE:

above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2016; LEED 2009 IEQ Credit

FDA

Guidelines for Resinous & Polymeric Coatings SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during

Lead Information Hotline at 1-800-424-LEAD, or visit www.epa.gov/lead or /asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• When the air temperature is at 35ºF, substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 35ºF and at least 5ºF above the dew point.

Avoid using if rain or snow is expected within 2-3 hours, as in colder temperatures, it may require air or surface temperatures below 35ºF or when air or surface temperatures may drop below 35ºF within 48 hours.

PRIMERS

DRYWALL

Textured:

Untextured:

Skim-coated:

VINYLASTIC® Premium (VNPR00)

MASONRY

Stucco:

Tilt-up concrete:

Poured-in-place:

Plaster:

Brick:

SUPER-LOC® Premium (SLPR00) or EFF-STOP® Premium (ESPR00)

Concrete block: Smooth BLOCFIL Premium (SBPR00) or Smooth trowel: SUPER-LOC® Premium (SLPR00)

WOOD/SYNTHETIC WOOD-INTERIOR

Trims, doors:

Masonite:

Hardboard:

INTER-KOTE® Premium (IKPR00) or ULTRA-GRIP® Premium (UGPR00)

WOOD-EXTERIOR

Trim, sash, fascia:

Rough-sawn:

T1-11 siding:

EZ-PRIME® Premium (EZPR00)

SYNTHETIC WOOD-EXTERIOR

Masonite:

Hardboard:

MDO siding:

ULTRA-GRIP® Premium (UGPR00)

METAL

Ferrous: BLOC-RUST® Premium (BRPR00) or

ENDURAPRIME™ Metal Primer (ENPR00)

Non-ferrous: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or BLOC-RUST® Premium (BRPR00)

Galvanized steel: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or *ULTRA-GRIP® Premium (UGPR00)

*for incidental use on galvanized to meet performance and environmental standards as shown on

DESCRIPTION: EVERSHIELD® Semi-Gloss is an ultra-premium exterior, ultra-low VOC, 100% acrylic semi-gloss paint that provides superior non-blocking properties, maximum protection against UV color fade, mildew, efflorescence, water intrusion, and film failure (grain-cracking, peeling, blistering). EVERSHIELD Semi-Gloss can be used on properly prepared and primed exterior and interior masonry, concrete, tilt-up, block, stucco, plaster, wood, and metal. Advanced technology and premium ingredients provide unparalleled performance, durability, coverage, and adhesion. Can be used down to surface and air temperature of 35ºF.

PRODUCT INFORMATION

≤ 50 g/L VOC**

EVERSHIELD®

Exterior/Interior Semi-Gloss Paint

EVSH50

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

6/16 (8/15)

SOLVENT TYPE: Waterborne RESIN TYPE: Acrylic

FINISH (ASTM D 523): 7–17% on a 60º meter

COLORS: White. EZ-PRIME Premium may be tinted with up to 2 fl. oz. of Dunn- Edwards ZTC Zero VOC colorant per gallon.

VISCOSITY@77ºF/25ºC (ASTM D 562): 87–97 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 20 g/L

SOLIDS BY VOLUME (ASTM D 2697)

41.0% ± 2%

SOLIDS BY WEIGHT

54.0% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 10.50 lbs.

COMPOSITION BY WEIGHT

Pigment–27.1% *Prime pigments ................................14.4 Reinforcing pigments ........................12.7

Vehicle–72.9% Acrylic resins .....................23.7 Water & additives ..............49.2

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 4.9 mils Dry: 2.0 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 275–325 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If necessary to maintain good workability, add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 30–60 minutes Recoat: 2–4 hours (see Special Instructions) Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING: Quart, one-gallon, five-gallon containers

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2013; MPI Approved Product #6;

CRGI Green Wise Certified

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800-424-LEAD, or visit www.

epa.gov/lead or /asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• Apply two coats of EZ-PRIME® Premium on redwood and cedar in order to stop tannin bleeding. Allow first coat to dry for 24 hours before applying the second coat.

• Do not apply when the air or surface temperature is below 50ºF.

USE AS A PRIMER FOR

WOOD

Trim, sash, fascia:

Rough-sawn:

T1-11 siding:

Plywood:

EZ-PRIME® Premium (EZPR00)

SYNTHETIC WOOD

Masonite:

Hardboard:

MDO siding:

EZ-PRIME® Premium (EZPR00)

DESCRIPTION: EZ-PRIME® Premium is an exterior acrylic primer that provides excellent enamel holdout and tannin stain resistance on woods such as redwood and cedar, which are subject to stain bleeding. EZ-PRIME Premium is also recommended on exterior plywood and T1-11 siding.

PRODUCT INFORMATION

EZ-PRIME® Premium Exterior Wood Primer

EZPR00-1

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

6/16 (8/15)

SOLVENT TYPE: Waterborne RESIN TYPE: Acrylic

FINISH (ASTM D 523): 7–14% on a 60º meter

COLORS: White. ULTRA-GRIP Premium may be tinted with up to 2 fl. oz. of Dunn-Edwards ZTC Zero VOC colorant per gallon.

TINT BASES: White

VISCOSITY@77ºF/25ºC (ASTM D 562): 95–105 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 20 g/L

SOLIDS BY VOLUME (ASTM D 2697)

40.5% ± 2%

SOLIDS BY WEIGHT

53.0% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 10.53 lbs.

COMPOSITION BY WEIGHT

Pigment–27.4% *Prime pigments ................................15.1 Reinforcing pigments ........................12.3

Vehicle–72.6% Acrylic resins .....................23.0 Water & additives ..............49.6

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 4.9 mils Dry: 2.0 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 275–325 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If necessary to maintain good workability, add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 30–60 minutes Recoat: 2–4 hours Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING: Quart, one-gallon, five-gallon containers

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2013; CHPS Section 01350; LEED 2009 IEQ Credit 4.2; LEED v4 EQ Credit 2; MPI Approved Product #17, #134; CRGI Green Wise Certified Gold; FDA Guidelines for Resinous & Polymeric Coatings

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800- 424-LEAD, or visit www.epa.gov/lead or /asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• ULTRA-GRIP Premium seals and blocks out most household stains, such as crayon, pencil, ink, and felt marker. After priming stained areas, test that the stain has been sealed by applying the topcoat to a small area. More than one coat may be necessary on severe stains. ULTRA-GRIP Premium may block minor dried water stains, however, a solvent-based stain blocking primer, such as pigmented shellac, is recommended.

• Galvanized metal must be cleaned with a solvent or a water-soluble degreasing cleaner to remove all oils prior to etching. Change wiping material and cleaning solution frequently so the oils are removed from the surface, not just spread around.

Surface should then be etched with Supreme Chemical Metal Clean & Etch (ME01).

• ULTRA-GRIP Premium can be used on bare ferrous metal surfaces (interior only) provided that they are free of rust, mill scale, and other contaminants. Before any surface preparation is attempted, oil and grease must be removed by employing SSPC-SP11 Power Tool Cleaning to Bare Metal to remove mill scale, rust, or other contaminants and to leave a roughened surface.

• Before applying over previously painted surfaces, ULTRA-GRIP Premium should be tested for adhesion and compatibility.

• On Level 4 and 5 Drywall Finishes, thin ULTRA-GRIP Premium with 10% of clean water (3/4 pint per gallon / 1/2 gallon per 5-gallon) for best penetration.

• Do not apply when the air or surface temperature is below 50ºF.

USE AS A PRIMER FOR

WALLBOARD & MASONRY

Drywall:

Stucco:

Concrete:

Brick:

ULTRA-GRIP® Premium (UGPR00)

WOOD-INTERIOR

Trim, doors: ULTRA-GRIP® Premium (UGPR00) or

INTER-KOTE® Premium (IKPR00)

WOOD-EXTERIOR

Trim, sash:

T1-11 siding:

ULTRA-GRIP® Premium (UGPR00) or EZ-PRIME® Premium (EZPR00)

SYNTHETIC WOOD

Masonite:

Hardboard:

ULTRA-GRIP® Premium (UGPR00)

METAL

Ferrous:

Non-ferrous:

BLOC-RUST® Premium (BRPR00), ULTRASHIELD® Galvanized Metal Primer (ULGM00), or ULTRA-GRIP® Premium (UGPR00) INTERIOR ONLY ULTRA-GRIP® Premium (UGPR00) or ULTRASHIELD® Galvanized Metal Primer (ULGM00)

OTHER SURFACES

Fiberglass:

Plastic:

ULTRA-GRIP® Premium (UGPR00) INTERIOR ONLY

DESCRIPTION: ULTRA-GRIP® Premium is an ultra-low VOC, acrylic multi-surface primer designed for a wide range of interior and exterior applications. It provides excellent adhesion to properly prepared drywall, wood, and masonry, as well as hard-to-stick surfaces, such as aged alkyd, aluminum, galvanized metal, vinyl, fiberglass, and select plastics. ULTRA-GRIP Premium has outstanding stain blocking, strong tannin resistance, great hide, and excellent enamel holdout. It applies smoothly, dries fast, and is compatible with all Dunn-Edwards latex and alkyd finishes.

PRODUCT INFORMATION

ULTRA-GRIP® Premium Interior/Exterior Multi-Surface Primer

UGPR00-1

DUNN-EDWARDS CORPORATION • 4885 East 52ND Place • Los Angeles, California 90058-5507 • (888) DE PAINT I dunnedwards.com

04/19 (10/18)

SOLVENT TYPE: Waterborne RESIN TYPE: Modified acrylic

FINISH (ASTM D 523): Semi-Gloss: 50–60% on a 60º meter;

COLORS: Stock colors: White, Swiss Coffee, Pearl White, and Cottage White.

Other colors can be special ordered or store mixed.

TINT BASES: L Tintable White, M Medium, U Ultra Deep

VISCOSITY@77ºF/25ºC (ASTM D 562): 98–108 KU

MAXIMUM VOC CONTENT

50 g/L (as supplied)

MAXIMUM RAVOC (Reactivity-Adjusted VOC) 20 g/L

SOLIDS BY VOLUME (ASTM D 2697)

34.0% ± 2%

SOLIDS BY WEIGHT

41.8% ± 2%

WEIGHT PER GALLON (ASTM D 1475): 9.70 lbs.

COMPOSITION BY WEIGHT

Pigment–15.8% *Prime pigments ................................15.8

Vehicle–84.2% Vinyl acrylic resins ................. 23.7 Water & additives .................. 60.5

*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.

RECOMMENDED FILM THICKNESS PER COAT

Wet: 4.4 mils Dry: 1.5 mils

PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS

Approximately 300–350 sq. ft. per gallon, depending on surface conditions and application techniques.

THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting under normal environmental and application conditions. If necessary to maintain good workability, add up to 1/4 pint (4 fl. oz.) to 1/2 pint (8 fl. oz.) of clean water per gallon of coating.

AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)

To touch: 1–2 hours Recoat: 6–8 hours Dry times and recoat times are temperature, humidity and film thickness dependent.

APPLICATION EQUIPMENT: Brush, roller, airless spray

PACKAGING: One-gallon, five-gallon containers

STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.

CLEANUP: Warm, soapy water

DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.

CONFORMS TO: ARB 2007 SCM & CALGreen 2016; LEED 2009 IEQ Credit 4.2;

MPI Approved Product #54

SAFETY DATA SHEET: Available at www.dunnedwards.com

SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.

SPECIAL INSTRUCTIONS

• CAUTION: Scraping or sanding surfaces of older buildings (especially pre-

1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Always wear appropriate personal protective equipment during surface preparation, and finish cleanup of any residues by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety” or call EPA’s National Lead Information Hotline at 1-800-424-LEAD, or visit www.

epa.gov/lead or/asbestos, or contact your state or local Health Department.

• This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.

• For sealing pigment-rich skim coats, such as “Prep Coat” and “First Coat,” use SPARTAWALL® (SWLL10).

• When the air temperature is at 35ºF, substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 35ºF and at least 5ºF above the dew point. Avoid using if rain or snow is expected within 2-3 hours, as in colder temperatures, it may require longer time before the paint film cures enough not to be affected by rain or snow. Do not apply at air or surface temperatures below 35ºF or when air or surface temperatures may drop below 35ºF within 48 hours.

• Standard latex primers cannot be used below 50ºF. See the specific primer product information sheet for that product’s application conditions.

PRIMERS

DRYWALL

Textured:

Untextured:

Skim-coated:

Self-priming (first coat)

MASONRY

Plaster:

Tilt-up concrete:

Poured-in-place:

Brick:

EFF-STOP® Premium (ESPR00) or EFF-STOP® Select (ESSL00)

Concrete block: Smooth BLOCFIL Premium (SBPR00), Smooth BLOCFIL Select (SBSL00) or FLEX-PRIME® Select (FPSL00)

WOOD/SYNTHETIC WOOD–INTERIOR

Trim, doors:

Masonite:

Hardboard:

INTER-KOTE® Premium (IKPR00), ULTRA-GRIP® Premium (UGPR00), ULTRA-GRIP® Select (UGSL00)

WOOD–EXTERIOR

Trim, sash, fascia:

Rough-sawn:

T1-11 siding:

EZ-PRIME® Premium (EZPR00)

METAL

Ferrous: BLOC-RUST® Premium (BRPR00) or ENDURAPRIME™ Metal Primer (ENPR00)

Non-ferrous: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or BLOC-RUST® Premium (BRPR00)

Galvanized steel: ULTRASHIELD® Galvanized Metal Primer (ULGM00) or *ULTRA-GRIP® Premium (UGPR00)

*for incidental use on galvanized

DESCRIPTION: VERSAGLO® is a professional interior/exterior, ultra-low VOC, latex semi-gloss paint. It is ideal for use on new residential, commercial, and multi-tenant housing projects. VERSAGLO provides very good hide, block resistance and touch-up, and can be used on properly prepared and primed masonry, wood, and metal. VERSAGLO is self-priming on new drywall. Can be used down to surface and air temperature of 35ºF.

PRODUCT INFORMATION

VERSAGLO®

Interior/Exterior Latex Semi-Gloss Paint W 6160E

3,6

S F

6,3

S F

AP

PR

OX

IM

AT

E

BU

IL

DI

NG

PA

IN

T

SQ

UA

RE

F

OO

TA

GE

,71

5 S F

B3 co nn ec tio n

7,8

S F

Bo th s id es

Bo th s id es

N or th

6, So ut h

- 3 ,6

Ea st

,0

W es t -

1, R oo f -

,0

O th er

2, 1, fo r c ov er ed w al kw ay s

To ta l -

9, 1,4

S F

0 S

F

1,1

S F

5 S

F63 0 S

F

AP

PR

OX

IM

AT

E

BU

IL

DI

NG

P

AI

NT

SQ

UA

RE

F

OO

TA

GE

4,6

S F

N or th

1, So ut h

- 1 ,1

Ea st

W…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .