36C26220Q0242-001.xlsx
XLSX spreadsheet Posted
- Attached to
- Thermo Cryostats Federal contract opportunity
- Solicitation number
- 36C26220Q0242
About this file
This solicitation requests quotes for the procurement of 14 clinical laboratory cryostats, on-site training, and associated maintenance service agreements for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22. Offerors must meet the salient characteristics for the Thermo Scientific brand or equal product as described in Attachment A and provide pricing in the specified format. Quotes are due by January 23, 2020 and the award will be made to the responsible offeror providing the lowest priced technically acceptable solution. Maintenance agreements for up to five years after delivery at multiple VA medical centers are also within scope.
36C26220Q0242 Attachment A_9Jan2020.xlsx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26220Q0242-000.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TAB 1
| ATTACHMENT A | |||
| PRODUCT DESCRIPTION | Brand | Equal* | *If an equal product is offered, please identify where in your offer the salient characteristics are met (i.e document name, page numer, paragraph, etc.) |
| Thermo Scientific - Cryostar NX50 - OPHD Configuration - Product #957110L |
SALIENT CHARACTERISTICS Meets Does Not Meet
Freestanding model with sizes range between 28.7”- 30.7” (Width) and 38.4” – 40.4” (Depth).
Must have a body-contoured design to put the user close to the chamber in both seated or standing positions. Motorized height adjustment (to minimize touching and cross-contamination on the equipment) with a range from 33” to 44” to allow for working in seated or standing positions.
100-120V certified.
Must have touchscreen user interface.
| Knife holder must have a low-profile blade holder, a blade guard to prevent injury, plastic holders to prevent frostbite and cut consistent sections. |
| Object Plate holder must contain at least 12 specimen spot holders. |
| Chamber must accommodate easy access for tools. |
| Must allow for surface disinfection of harmful bacteria, viruses and spores. |
| Must have an automated disinfection method for the cold cutting chamber which may be performed by pre-programming or immediately. |
| Must have a defrost method. |
| Must have a temperature range of at least -10° to -30° Celsius. |
| Must provide on-site training of new equipment. |
| Must include a one-year warranty on new equipment. |
TAB 2
| DELIVERY LOCATIONS | QUANTITY | UNIT PRICE | EXTENDED PRICE |
| VA Long Beach Healthcare System | 2 ea | ||
| 5901 East 7th Street | |||
| Long Beach, CA 90822 | |||
| VA Loma Linda Healthcare System | 2 ea | ||
| 11201 Benton Street | |||
| Loma Linda, CA 92357 | |||
| VA San Diego Healthcare System | 3 ea | ||
| 3350 La Jolla Village Drive | |||
| San Diego, CA 92161 | |||
| VA Southern Arizona Health Care System | 2 ea | ||
| 3601 South 6th Avenue | |||
| Tucson, AZ 85723 | |||
| VA Phoenix Health Care System | 2 ea | ||
| 650 East Indian School Road | |||
| Phoenix, AZ 85012 | |||
| VA New Mexico Health Care System | 2 ea | ||
| 1501 San Pedro SE | |||
| Albuquerque, NM 87108 | |||
| VA Greater Los Angeles Healthcare System | 1 ea | ||
| 11301 Wilshire Boulevard | |||
| Los Angeles, CA 90073 | |||
| Option Year # 1 - | 14 ea | ||
| Maintenance/Service Agreements | |||
| Performance period one year after delivery | |||
| Option Year # 2 - | 14 ea | ||
| Maintenance/Service Agreements | |||
| Performance period two years after delivery | |||
| Option Year # 3 - | 14 ea | ||
| Maintenance/Service Agreements | |||
| Performance period three years after delivery | |||
| Option Year # 4 - | 14 ea | ||
| Maintenance/Service Agreements | |||
| Performance period four years after delivery |