36C26118Q0567-0002001.pdf
PDF 2 MB Posted
- Attached to
- Architectural Materials BPA
- Solicitation number
- 36C26118Q0567
About this file
36C26118Q0567 0002 Attachment 1 - Serenity RC.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26118Q0567-0002000.docx | DOCX document | |
| 36C26118Q0567-00001000.docx | DOCX document | |
| 36C26118Q0567-001.xlsx | XLSX spreadsheet | |
| 36C26118Q0567-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.CWallA.com
WASHINGTON
Spokane 509-535-5637
Seattle 425-488-7577
Tacoma 253-840-4455
Tri-Cities 509-542-1411
Yakima 509-452-6777
CALIFORNIA
Sacramento 916-624-7700
Stockton 209-670-8053
San Francisco 415-852-7974
San Jose 408-660-2093
Fresno 559-256-9911
NEVADA
Reno 916-768-7458
OREGON
Portland 503-282-1750
Salem 503-371-8033
Eugene 541-345-8899
MONTANA
Missoula 406-542-7004
Billings 406-248-2600
IDAHO
Boise 208-323-4901
ALASKA
Anchorage 907-868-1100
ALBERTA
Calgary 403-265-9005
HAWAII
Honolulu 808-202-4241
SCAFCO products are distributed by CWallA and other fine distributors
STOCKING BRANCHES
PERFECT CURVE™ PRODUCTS
SOUND
CHANNELSERENITY-RC
#1 CHOICE FOR
Sound Assemblies www.SCAFCO.com2 ©2017 SCAFCO
Premium Product
• Exceptional control of sound transmission through ceilings and partition wall assemblies
• Lab Certified STC Rating up to 61
Material Composition
• D-25 material
◦ 50 ksi min. yield strength
◦ 65 ksi min. tensile strength
◦ G40 galvanized coating
• ASTM A653/A653M
1/8"
5/16"
½"
½"
1 1/4"
2"
1/8"
5/16"
½"
½"
1 ½"
2 1/4"
RC-1 RC-DELUXE
RCEF-1
1/8"
5/16"
7/8"
½"
1 ¼"
2 ⅜"
1/8" 5/16"
½"
½" 1 ½"
2 1/4"
RC-DELUXE V2
Serenity Profile
TESTING
Riverbank Acoustical Laboratories Sound assemblies are constructed, thoroughly inspected and then certified by Riverbank Acoustical Laboratories. NVLAP accredited for ASTM E90-09 & E413-10, ISO Certified.
Riverbank Acoustical Laboratories is accredited by the US department of commerce, National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 100227-0) to ISO 17025:2005 laboratory quality management and specific acoustical test standards.
SSA Acoustics SSA Acoustics, a leader in engineering acoustics and multi-family residential design for 17 + years, has conducted extensive testing and research on SCAFCO’s Serenity Resilient Channel.
SSA’s team of acoustical consultants and lab technicians tested Serenity-RC for isolation efficiency, and in-field performance. When comparing the results gathered to those of other products within the industry, the team found that Serenity-RC is the superior product for reducing airborne transmission in walls and ceilings, for both wood and steel assemblies.
Serenity-RC consistently measured better than its competitors in isolation and efficiency tests, both critical to obtaining elevated STC (Sound Transmission Class) performance. SSA’s group of highly qualified consultants continue to research, develop and test the product to ensure it meets all required sound specifications.
The all-around performance of Serenity-RC impressed Bill Stewart the managing partner of SSA Acoustics:
SERENITY-RC
Serenity-RC is a premium product and the best cost effective solution for reducing the transmission of airborne sound through walls and ceilings. By separating the drywall from the stud flange, the channel minimizes the direct path by which sound travels through the framing, as detailed on page 3.
SCAFCO’s Serenity-RC was professionally sound tested at Riverbank Acoustical Laboratories, one of the leading and longest-standing acoustical testing facilities in the United States.
Acoustical testing for the STC performance of Serenity-RC proved the product's ability to provide high-end sound performance for both steel and wood framed assemblies, well above other high-end RC products available.
Serenity-RC
"The superior performance of Serenity-RC in lab and field testing is un-matched. Recommended as our basis of design in all resilient channel applications”
Bill Stewart www.ssaacoustics.com (206) 839-0819
3Effective 03/21/17 and supersedes all previous information. www.SCAFCO.com
Serenity-RC
Serenity-RC has been engineered, with help from the acoustical community, to include the following features that reduce sound transmission through the assembly.
Slot and Hole Pattern
• 1¼" x 5/16" Slots
• 3/16" (#8 Screw) Holes
• Slots and holes are aligned to increase the path that sound must travel through the assembly
• 2” Slot spacing along the channel allows for wall and ceiling framing at almost any spacing conditions including the typical 12” o.c, 16” o.c, and 24” o.c
Stiffening Ribs
• 1/16" Raise stiffening ribs
• Creates seperation and air space between sheathing and framing stud
• Only 2 points of contact between sheathing and framing stud, decreases area for sound transmission
Serenity Knurling
• Stiffens attachment flange to create gap between sheathing
• Aids in positive screw attachment through thin acoustical steel profile
Profile Features
Stiffening Ribs
Stiffening Ribs
Sound
Serenity knurling is product identification on the jobsite www.SCAFCO.com4 ©2017 SCAFCO
Serenity RC Assembly
Serenity-RC with Cold-Formed Metal Framing Serenity-RC is formed from D25 galvanized steel, and when used in connection with sound attenuation blankets, it increases the effectiveness of the sound resistant assembly. Serenity-RC is installed horizontally at 24" o.c. and is easily attached with framing screws through its pre-punched holes.
Features and Benefits
• Cost effective sound management on metal framing
• Decoupling across all frequencies
• Easily attached through pre-punched holes
• Tested with single and double layer drywall
• Available in 12' lengths
Serenity RC Ceiling Assembly
52 STC
• 3 ⅝" Metal stud 24" o.c.
• R-13 Insulation
• RC-1 Channel (one side)
• ⅝" Type X GWB (single layer both sides)
58 STC
• 3 ⅝" Metal stud 24" o.c.
• R-13 Insulation
• RC-1 Channel (one side)
• ⅝" Type X GWB (single layer one side, double layer opposite side)
61 STC
• 3 ⅝" Metal stud 24" o.c.
• R-13 Insulation
• RC-1 Channel (one side)
• ⅝" Type X GWB
(double layer both sides)
FRAMING
5Effective 03/21/17 and supersedes all previous information. www.SCAFCO.com
Features and Benefits
• Cost effective sound management on wood framing
• Decoupling across all frequencies
• Tested on 2x4 and 2x6 wood studs
• Tested with single and double layer drywall
• Available in 12' lengths
53 STC (2x4 studs) 53 STC (2x6 studs)
• R-13, R-19 Insulation
• Serenity-RC (one side)
• ⅝" Type X GWB (single layer one side, double layer opposite side)
46 STC (2x4 studs) 48 STC (2x6 studs)
• Framing at 24" o.c.
• R-13, R-19 Insulation
• Serenity-RC (one side)
• ⅝" Type X GWB (single layer both sides)
58 STC (2x4 studs) 58 STC (2x6 studs)
• R-13, R-19 Insulation
• Serenity RC (one side)
• ⅝" Type X GWB
(double layer both sides)
Serenity RC Assembly
Serenity-RC with Wood Framing Serenity-RC effectively isolates drywall from wood studwork and substantially weakens sound waves traveling through them.
Attaching Serenity-RC in wood applications is nearly effortless and will provide superior STC ratings beyond other resilient channel products on the market.
Serenity RC Ceiling Assembly
FRAMING
www.SCAFCO.com6 ©2017 SCAFCO
Serenity-RC Channel must be installed per specifications of the USG Drywaller’s Handbook, ASTM C754 “Installation of Steel Framing Members to Receive Screw Attached Gypsum Panel Products”, and SCAFCO’s Manufacturer Instructions.
A full list of SCAFCO’ s installation instructions for steel and wood assemblies can be found at www.SCAFCO.com, or by contacting Technical@SCAFCO.com.
The following details illustrate important installation considerations:
Installation Instructions
Wall Assemblies:
• Install Serenity RC horizontally and space 24” o.c to match the laboratory test data.
• Install Serenity-RC channel to wood or steel studs 2” from floor and within 6” from top of wall, with steel/wood fasteners providing sufficient anchorage. The attachment flange shall be installed below face of channel for all rows except bottom row which will be inverted.
• Allow 1/4” gap from resilient ceilings, and 1/8” minimum gap for acoustical calk around all other edges. Do not rest gypsum board on floor, intersecting walls, or ceilings.
• Cabinets or other wall hung items mounted on resilient channel walls cannot be attached through to the studs. Utilize toggle bolts if gypsum board is adequate for strength, if not utilize different acoustical assembly.
Serenity-RC
General Requirements:
• For single layer drywall assemblies utilize 1” long framing screws for attachment to resilient channel flange. For attachment through two layers use 1 5/8” long fasteners.
• DO NOT fasten through resilient channel flange and into wall/ceiling studs. Longer fasteners will result in short circuit and reduced performance of the resilient channel. See detail C.
2”
5/8” max
6” max
DETAIL A 1/8” max
DETAIL B
DETAIL C
A
B
C
D
DETAIL D
1/4” max
2”
5/8” max
6” max
DETAIL A 1/8” max
DETAIL B
DETAIL C
A
B
C
D
DETAIL D
1/4” max
Fastener is too long
Backing Creates an Acoustic Short Circuit
ASSEMBLIES
7Effective 03/21/17 and supersedes all previous information. www.SCAFCO.com
Ceiling Assemblies:
• Attach Serenity-RC perpendicular to the ceiling joists
24” o.c. for joists 16” o.c.; 16” o.c. for joists 24” o.c.
For multiple layers of Gypsum Board decrease spacing of resilient channel. Spacing should be decreased in conjunction with the weight of boards/materials added, to provide sufficient anchorage and load distribution.
• Allow 1/8” gap for acoustical calk around all edges. Do not rest edge of boards on adjacent walls or ceilings.
Serenity-RC
Serenity RC Ceiling Assembly
Serenity-RC with Ceiling Assemblies Serenity-RC is ideal for reducing sound passing through ceiling assemblies. Its quick and easy installation immediately diminishes both airborne noise and impact sound to achieve the best STC ratings in the industry.ASSEMBLIES
Joist Serenity-RC Channel
24"o.c.
16"o.c.
24"o.c.
16"o.c.
www.CWallA.com
WASHINGTON
Spokane 509-535-5637
Seattle 425-488-7577
Tacoma 253-840-4455
Tri-Cities 509-542-1411
Yakima 509-452-6777
CALIFORNIA
Sacramento 916-624-7700
Stockton 209-670-8053
San Francisco 415-852-7974
San Jose 408-660-2093
Fresno 559-256-9911
NEVADA
Reno 916-768-7458
OREGON
Portland 503-282-1750
Salem 503-371-8033
Eugene 541-345-8899
MONTANA
Missoula 406-542-7004
Billings 406-248-2600
IDAHO
Boise 208-323-4901
ALASKA
Anchorage 907-868-1100
ALBERTA
Calgary 403-265-9005
HAWAII
Honolulu 808-202-4241
SCAFCO products are distributed by CWallA and other fine distributors
STOCKING BRANCHES
PERFECT CURVE™ PRODUCTS
SOUND
CHANNELSERENITY-RC
Customer Service SCAFCO is a full service steel stud manufacturing company. In addition to our two manufacturing plants in Spokane and Stockton, we also feature press brakes and shears capable of making on demand, custom parts up to 24' in length.
Contact Engineering Services For assistance with ordering or questions on your project, utilize SCAFCO Engineering Services:
Call: 509-789-8669 Email: technical@SCAFCO.com Website: www.SCAFCO.com/steel
SRC----117
File details come from the government source that posted it.