Text version

www.CWallA.com

WASHINGTON

Spokane 509-535-5637

Seattle 425-488-7577

Tacoma 253-840-4455

Tri-Cities 509-542-1411

Yakima 509-452-6777

CALIFORNIA

Sacramento 916-624-7700

Stockton 209-670-8053

San Francisco 415-852-7974

San Jose 408-660-2093

Fresno 559-256-9911

NEVADA

Reno 916-768-7458

OREGON

Portland 503-282-1750

Salem 503-371-8033

Eugene 541-345-8899

MONTANA

Missoula 406-542-7004

Billings 406-248-2600

IDAHO

Boise 208-323-4901

ALASKA

Anchorage 907-868-1100

ALBERTA

Calgary 403-265-9005

HAWAII

Honolulu 808-202-4241

SCAFCO products are distributed by CWallA and other fine distributors

STOCKING BRANCHES

PERFECT CURVE™ PRODUCTS

SOUND

CHANNELSERENITY-RC

#1 CHOICE FOR

Sound Assemblies www.SCAFCO.com2 ©2017 SCAFCO

Premium Product

• Exceptional control of sound transmission through ceilings and partition wall assemblies

• Lab Certified STC Rating up to 61

Material Composition

• D-25 material

◦ 50 ksi min. yield strength

◦ 65 ksi min. tensile strength

◦ G40 galvanized coating

• ASTM A653/A653M

1/8"

5/16"

½"

½"

1 1/4"

2"

1/8"

5/16"

½"

½"

1 ½"

2 1/4"

RC-1 RC-DELUXE

RCEF-1

1/8"

5/16"

7/8"

½"

1 ¼"

2 ⅜"

1/8" 5/16"

½"

½" 1 ½"

2 1/4"

RC-DELUXE V2

Serenity Profile

TESTING

Riverbank Acoustical Laboratories Sound assemblies are constructed, thoroughly inspected and then certified by Riverbank Acoustical Laboratories. NVLAP accredited for ASTM E90-09 & E413-10, ISO Certified.

Riverbank Acoustical Laboratories is accredited by the US department of commerce, National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 100227-0) to ISO 17025:2005 laboratory quality management and specific acoustical test standards.

SSA Acoustics SSA Acoustics, a leader in engineering acoustics and multi-family residential design for 17 + years, has conducted extensive testing and research on SCAFCO’s Serenity Resilient Channel.

SSA’s team of acoustical consultants and lab technicians tested Serenity-RC for isolation efficiency, and in-field performance. When comparing the results gathered to those of other products within the industry, the team found that Serenity-RC is the superior product for reducing airborne transmission in walls and ceilings, for both wood and steel assemblies.

Serenity-RC consistently measured better than its competitors in isolation and efficiency tests, both critical to obtaining elevated STC (Sound Transmission Class) performance. SSA’s group of highly qualified consultants continue to research, develop and test the product to ensure it meets all required sound specifications.

The all-around performance of Serenity-RC impressed Bill Stewart the managing partner of SSA Acoustics:

SERENITY-RC

Serenity-RC is a premium product and the best cost effective solution for reducing the transmission of airborne sound through walls and ceilings. By separating the drywall from the stud flange, the channel minimizes the direct path by which sound travels through the framing, as detailed on page 3.

SCAFCO’s Serenity-RC was professionally sound tested at Riverbank Acoustical Laboratories, one of the leading and longest-standing acoustical testing facilities in the United States.

Acoustical testing for the STC performance of Serenity-RC proved the product's ability to provide high-end sound performance for both steel and wood framed assemblies, well above other high-end RC products available.

Serenity-RC

"The superior performance of Serenity-RC in lab and field testing is un-matched. Recommended as our basis of design in all resilient channel applications”

Bill Stewart www.ssaacoustics.com (206) 839-0819

3Effective 03/21/17 and supersedes all previous information. www.SCAFCO.com

Serenity-RC

Serenity-RC has been engineered, with help from the acoustical community, to include the following features that reduce sound transmission through the assembly.

Slot and Hole Pattern

• 1¼" x 5/16" Slots

• 3/16" (#8 Screw) Holes

• Slots and holes are aligned to increase the path that sound must travel through the assembly

• 2” Slot spacing along the channel allows for wall and ceiling framing at almost any spacing conditions including the typical 12” o.c, 16” o.c, and 24” o.c

Stiffening Ribs

• 1/16" Raise stiffening ribs

• Creates seperation and air space between sheathing and framing stud

• Only 2 points of contact between sheathing and framing stud, decreases area for sound transmission

Serenity Knurling

• Stiffens attachment flange to create gap between sheathing

• Aids in positive screw attachment through thin acoustical steel profile

Profile Features

Stiffening Ribs

Stiffening Ribs

Sound

Serenity knurling is product identification on the jobsite www.SCAFCO.com4 ©2017 SCAFCO

Serenity RC Assembly

Serenity-RC with Cold-Formed Metal Framing Serenity-RC is formed from D25 galvanized steel, and when used in connection with sound attenuation blankets, it increases the effectiveness of the sound resistant assembly. Serenity-RC is installed horizontally at 24" o.c. and is easily attached with framing screws through its pre-punched holes.

Features and Benefits

• Cost effective sound management on metal framing

• Decoupling across all frequencies

• Easily attached through pre-punched holes

• Tested with single and double layer drywall

• Available in 12' lengths

Serenity RC Ceiling Assembly

52 STC

• 3 ⅝" Metal stud 24" o.c.

• R-13 Insulation

• RC-1 Channel (one side)

• ⅝" Type X GWB (single layer both sides)

58 STC

• 3 ⅝" Metal stud 24" o.c.

• R-13 Insulation

• RC-1 Channel (one side)

• ⅝" Type X GWB (single layer one side, double layer opposite side)

61 STC

• 3 ⅝" Metal stud 24" o.c.

• R-13 Insulation

• RC-1 Channel (one side)

• ⅝" Type X GWB

(double layer both sides)

FRAMING

5Effective 03/21/17 and supersedes all previous information. www.SCAFCO.com

Features and Benefits

• Cost effective sound management on wood framing

• Decoupling across all frequencies

• Tested on 2x4 and 2x6 wood studs

• Tested with single and double layer drywall

• Available in 12' lengths

53 STC (2x4 studs) 53 STC (2x6 studs)

• R-13, R-19 Insulation

• Serenity-RC (one side)

• ⅝" Type X GWB (single layer one side, double layer opposite side)

46 STC (2x4 studs) 48 STC (2x6 studs)

• Framing at 24" o.c.

• R-13, R-19 Insulation

• Serenity-RC (one side)

• ⅝" Type X GWB (single layer both sides)

58 STC (2x4 studs) 58 STC (2x6 studs)

• R-13, R-19 Insulation

• Serenity RC (one side)

• ⅝" Type X GWB

(double layer both sides)

Serenity RC Assembly

Serenity-RC with Wood Framing Serenity-RC effectively isolates drywall from wood studwork and substantially weakens sound waves traveling through them.

Attaching Serenity-RC in wood applications is nearly effortless and will provide superior STC ratings beyond other resilient channel products on the market.

Serenity RC Ceiling Assembly

FRAMING

www.SCAFCO.com6 ©2017 SCAFCO

Serenity-RC Channel must be installed per specifications of the USG Drywaller’s Handbook, ASTM C754 “Installation of Steel Framing Members to Receive Screw Attached Gypsum Panel Products”, and SCAFCO’s Manufacturer Instructions.

A full list of SCAFCO’ s installation instructions for steel and wood assemblies can be found at www.SCAFCO.com, or by contacting Technical@SCAFCO.com.

The following details illustrate important installation considerations:

Installation Instructions

Wall Assemblies:

• Install Serenity RC horizontally and space 24” o.c to match the laboratory test data.

• Install Serenity-RC channel to wood or steel studs 2” from floor and within 6” from top of wall, with steel/wood fasteners providing sufficient anchorage. The attachment flange shall be installed below face of channel for all rows except bottom row which will be inverted.

• Allow 1/4” gap from resilient ceilings, and 1/8” minimum gap for acoustical calk around all other edges. Do not rest gypsum board on floor, intersecting walls, or ceilings.

• Cabinets or other wall hung items mounted on resilient channel walls cannot be attached through to the studs. Utilize toggle bolts if gypsum board is adequate for strength, if not utilize different acoustical assembly.

Serenity-RC

General Requirements:

• For single layer drywall assemblies utilize 1” long framing screws for attachment to resilient channel flange. For attachment through two layers use 1 5/8” long fasteners.

• DO NOT fasten through resilient channel flange and into wall/ceiling studs. Longer fasteners will result in short circuit and reduced performance of the resilient channel. See detail C.

2”

5/8” max

6” max

DETAIL A 1/8” max

DETAIL B

DETAIL C

A

B

C

D

DETAIL D

1/4” max

2”

5/8” max

6” max

DETAIL A 1/8” max

DETAIL B

DETAIL C

A

B

C

D

DETAIL D

1/4” max

Fastener is too long

Backing Creates an Acoustic Short Circuit

ASSEMBLIES

7Effective 03/21/17 and supersedes all previous information. www.SCAFCO.com

Ceiling Assemblies:

• Attach Serenity-RC perpendicular to the ceiling joists

24” o.c. for joists 16” o.c.; 16” o.c. for joists 24” o.c.

For multiple layers of Gypsum Board decrease spacing of resilient channel. Spacing should be decreased in conjunction with the weight of boards/materials added, to provide sufficient anchorage and load distribution.

• Allow 1/8” gap for acoustical calk around all edges. Do not rest edge of boards on adjacent walls or ceilings.

Serenity-RC

Serenity RC Ceiling Assembly

Serenity-RC with Ceiling Assemblies Serenity-RC is ideal for reducing sound passing through ceiling assemblies. Its quick and easy installation immediately diminishes both airborne noise and impact sound to achieve the best STC ratings in the industry.ASSEMBLIES

Joist Serenity-RC Channel

24"o.c.

16"o.c.

24"o.c.

16"o.c.

www.CWallA.com

WASHINGTON

Spokane 509-535-5637

Seattle 425-488-7577

Tacoma 253-840-4455

Tri-Cities 509-542-1411

Yakima 509-452-6777

CALIFORNIA

Sacramento 916-624-7700

Stockton 209-670-8053

San Francisco 415-852-7974

San Jose 408-660-2093

Fresno 559-256-9911

NEVADA

Reno 916-768-7458

OREGON

Portland 503-282-1750

Salem 503-371-8033

Eugene 541-345-8899

MONTANA

Missoula 406-542-7004

Billings 406-248-2600

IDAHO

Boise 208-323-4901

ALASKA

Anchorage 907-868-1100

ALBERTA

Calgary 403-265-9005

HAWAII

Honolulu 808-202-4241

SCAFCO products are distributed by CWallA and other fine distributors

STOCKING BRANCHES

PERFECT CURVE™ PRODUCTS

SOUND

CHANNELSERENITY-RC

Customer Service SCAFCO is a full service steel stud manufacturing company. In addition to our two manufacturing plants in Spokane and Stockton, we also feature press brakes and shears capable of making on demand, custom parts up to 24' in length.

Contact Engineering Services For assistance with ordering or questions on your project, utilize SCAFCO Engineering Services:

Call: 509-789-8669 Email: technical@SCAFCO.com Website: www.SCAFCO.com/steel

SRC----117

File details come from the government source that posted it.