36C26118B0293-00002000.docx

DOCX document 26 KB Posted

Attached to
331 MPD Replace Flooring and Finishes Federal contract opportunity
Solicitation number
36C26118B0293
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21

About this file

36C26118B0293 00002 36C26118B0293 00002.docx

View the file

Other files for this federal contract opportunity

Other files attached to 331 MPD Replace Flooring and Finishes, newest first.
File Type Posted
36C26118C0074-001.docx DOCX document
36C26118B0293-00005000.docx DOCX document
36C26118B0293-00004001.docx DOCX document
36C26118B0293-00003004.docx DOCX document
36C26118B0293-00003005.pdf PDF
36C26118B0293-00002001.pdf PDF
36C26118B0293-00001005.pdf PDF
36C26118B0293-00001004.pdf PDF
36C26118B0293-00001003.docx DOCX document
36C26118B0293-033.docx DOCX document
36C26118B0293-029.pdf PDF
36C26118B0293-028.pdf PDF
36C26118B0293-034.pdf PDF
36C26118B0293-026.docx DOCX document
36C26118B0293-025.docx DOCX document
36C26118B0293-031.pdf PDF
36C26118B0293-035.docx DOCX document
36C26118B0293-032.pdf PDF
36C26118B0293-036.docx DOCX document
36C26118B0293-030.pdf PDF
36C26118B0293-027.pdf PDF
36C26118B0293-000.docx DOCX document
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2.

AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE

OF PAGES

10A. MODIFICATION OF

CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV.

11/2016) is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITE M 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES

SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR

43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes r eference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

BY

Contractor

16C. DATE SIGNED

14.

DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME

AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS

OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 00002 04-10-2018 640A0-16-111 Department of Veterans Affairs VA Sierra Pacific Network (VISN 21) VA Sierra Nevada Health Care System 975 Kirman Avenue Reno NV 89502-2597 Department of Veterans Affairs VA Sierra Pacific Network (VISN 21) VA Sierra Nevada Health Care System 975 Kirman Avenue Reno NV 89502-2597 To all Offerors/Bidders

36C26118B0293 04-10-2018

X x x The purpose of this amendment is to answer RFIs #4 through #10 and incorporate revised wage determination CA180029 dated April 6, 2018.

RFI #4: For the finishes floor material in the lavatory it shows RES-1. There is no detail or spec illustrating what RES-1 is. But there is a spec on RES-2 is that what RES-1 is supposed to be or is RES-1 just the epoxy base and RES-2 is with Vinyl Chip Broadcast. If RES-1 is just the epoxy base then would EPX-1 be the same thing?

Answer: All the Lavatories have 1” x 1” ceramic floor tile. The walls have 4’ x 4’ ceramic tile the bottom row of these are sanitary base tiles. These are all to be removed.

The Waterproof, slip-proof, anti-microbial, seamless epoxy floor covering is to be installed over the entire floor and coved up the wall. It will end and be sealed at approximately 4” where the sanitary base tile were removed from and the existing 4” x 4” wall tile that remain.

All lavatories will be the same with the same color (to be selected by the COR).

RFI #5: 01 00 00 para 1.2/A/2 indicates that the contractor is to protect, remove, and store in a secure area all Government fixtures, furniture, and equipment located in the work spaces, and then return to the locations found at the completion of each phase.

1)Will the VA provide a secure storage location within Building 331 for these items?
2)If storage is unavailable within the facility, will the VA provide a secure storage location somewhere on campus for these items?

Answer: In the center of each phase is a 20’ x 20’ store room that is not within this scope of work. It may be used for any storage needs.

RFI #6: Is there going to be a reflected ceiling plan issued to determine the location of the acoustical ceilings versus hard lid?

Answer: The original design for this project had the ceiling grid in the lavatories being replaced. This was changed at the last minute to “Wash Ceiling Grid”. Not all references were corrected at that time.

RFI #7: Will there be an asbestos report issued determining what areas that are to be removed are considered "Hot"?

Answer: Building 331 was built in the late 1970’s after ACM was removed from building products. The building is not considered Hot. Should the contractor find what they think is ACM in the course of the project, bring it to the attention of the COR for direction on how to proceed.

RFI #8: D-wing Accent paint plan and accent flooring plans were provided, will there be plans provided for accents in B wing or are we to mirror D Wing Plans?

Answer: The Accent color scheme is the same for both wings. The accent color for each wing is different.

RFI #9: In the specifications, item#6 “Replace wall and floor finishes at Multi-Patient shower room Wing D” on the room finish schedule it says NA. Please provide the wall tile selection for us to use in our bid?

Answer: The ceramic tile in the shower room is the standard Dal 4”x4” or equivalent. Color and accent color will be selected by the COR.

RFI #10: Is there any elevation sheets for the shower rooms? We will need details for height of ceramic tile walls or are we tiling to the ceiling? Will there be any accent tiles on the walls?

Answer: Ceramic tile elevations in the shower room are: Showers – floor to ceiling, Other walls Approximately 54”.

ATTACHMENT:

See attached document: P07 Revised Wage Determination CA180029 4.6.18.