36C25918Q0479-000.docx
DOCX document 15 KB Posted
- Solicitation number
- 36C25918Q0479
About this file
36C25918Q0479 36C25918Q0479.docx
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Combined Synopsis/Solicitation Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Combined Synopsis/Solicitation Notice Rev. March 2010
BRAND NAME REQUEST MFG.: ABBOTT LABORATORIES
1 EA PRECISION UPG, ENSITE PRECISION CARDIAC MAPPING SYSTEM
UPGRADE
80111 36C25918Q0479 05-09-2018 N 339112 Department of Veterans Affairs Network Contracting Office
NCO 19
6162 South Willow Drive, Suite 300 Greenwood Village CO 80111
GERALD MCCLURE
970-242-0731 x3875
DEPARTMENT OF VETERANS AFFAIRS
VA MEDICAL CENTER
ATTN: WAREHOUSE BLDG.7
500 FOOTHILL BLVD.
SALT LAKE CITY, UT
84148 gerald.mcclure@va.gov gerald.mcclure@va.gov
STATEMENT OF WORK (SOW)
Ensite(Precision) Cardio Mapping Upgrade
The Salt Lake City Veterans Health Care System is in the need to purchase the Ensite(Precision) Cardio Mapping Upgrade. The Cardiology Department currently uses the Ensite Cardio Mapping System and needs to purchase the upgrade to be able to provide better treatment/care for patients. This will be a brand name request.
Description The Ensite Precision System is comprised of three groups of components; the Ensite Amplifier, the display workstation and the Ensite Precision Module. The system includes the Ensite Courier PACS Module V3.0, Ensite Derxi Module V.1.3.1, Ensite Verismo Module V.2.0.1 and Ensite Fusion ModuleV.7.1.
Salient Characteristics Cardiac Cath Upgrade EnSite™ AutoMap o The software module allows user to create high density maps with any catheter. Collect data with no point limit. Automatic deletion of points outside user-specific criteria. Automated point inclusion and exclusion criteria include: score threshold for morphology match, cycle length tolerance, catheter speed limit, distance threshold, signal to noise threshold, force.
EnSite™ AutoMark o The software module allows for automated lesion marker guidance based on user-defined criteria. Size and color lesion markers based on multiple criteria. Assess ablation catheter stability and AutoMark placement with the AutoTrack feature for automatic recording of precise tip location during RF energy application
(1) Anti Fatigue Mat EnSite Connect™ Remote Access for real time technical support through a secure broadband connection.
• A magnetic interface that will work in conjunction with the mapping system- This piece of hardware will provide magnetic scaling for the mapping system and provide a more precise depiction of the anatomy as compared to an MRI or CT scan. It will also provide a second set of “eyes” as a reference for stability. This is made possible by using a sensor enabled circular mapping catheter called the Advisor FL, replacing the Reflexion Spiral.
•AutoMark expansion module- automated lesion marker when the Ampere ablation generator is being used. No longer will the lesions be subjective based on the person running the mapping system. The physician and system operator will discuss the parameters he/she desires to achieve during ablation and once those parameters are met, an automated visual lesion will be earned and marked on the model. Examples of the parameters would include time of ablation, power of ablation, temperature, contact force applied with the catheter, impedance drop, etc.
• Automap expansion module- this module is designed to be used when mapping and re-mapping various arrhythmias. It automates the mapping procedure and allows the operator to go back and re-map at 10 times the speed with recorded data, improving efficiencies and saving procedure time. We maintain the ability to annotate/adjust each point when desired by the physician.
• New Precision Patches- the new patches are smaller and stickier and we feel that they won’t peel away over time or on a sweaty patient, leading to an improvement in the overall stability of the system Compliance
Scope The contractor will have the requested products delivered and installed at VA Medical Center, 500 Foothill Blvd., Salt Lake City UT, 84148.
Items to be purchased.
EnSite Precision Cardiac Mapping System
END OF STATEMENT OF WORK
File details come from the government source that posted it.