36C25726Q0160.docx
DOCX document 20 KB Posted
- Attached to
- 6640--Volcano Intrasight Philips
- Solicitation number
- 36C25726Q0160
About this file
This document is a Sources Sought Notice issued by the Department of Veterans Affairs (VA) Network Contracting Office for the Amarillo VA Medical Center. The VA requires a brand name or equal Philips Intrasight Mobile 5/Volcano system to be integrated with a GE Mac-Lab system in a new Cardiac Catheterization Lab. The specialized medical equipment will enable interventional heart studies for local Veterans, featuring combined diagnostic modalities including Intravascular Ultrasound (IVUS), Instantaneous Wave Free Ratio (iFR), Fractional Flow Reserve (FFR), and angiography co-registration.
The solicitation (36C25726Q0160) seeks responses from potential vendors by 12/12/2025 at 3 PM Central Time. Interested businesses must submit detailed information including business name, contact details, SAM registration, NAICS code, business size, business type, and an authorization letter from Philips Healthcare Solutions. The equipment will be installed at 6010 Amarillo Blvd West, Amarillo, Texas, with all work to be performed during normal business hours and following guidelines from The Joint Commission, NFPA, CDRH, and VAMC. The system specifications include a 9.7" diagonal monitor, a CPU processor with 2/3 GHz, DICOM compatibility, and Windows 10 operating system.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
Volcano Intrasight Philips
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 76504 |
| SOLICITATION NUMBER* |
| 36C25726Q0160 |
| RESPONSE DATE/TIME/ZONE |
| 12-12-2025 3PM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 20 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6640 |
| NAICS CODE* |
| 339113 |
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Central Texas Veterans HCS 1901 Veterans Memorial Dr. Building #171 Temple TX 76504
POINT OF CONTACT*
Contracting Officer Rafael Rodriguez
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| Rafael.Rodriguez2@va.gov |
EMAIL DESCRIPTION
Sources Sought Notice Sources Sought Notice
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
This market research notice is being conducted by Network Contracting Office (NCO) 17- VA Central Texas (VACTHCS) facilities.
The AVAMC (Amarillo VA Medical Center) requires a brand name or equal Philips Intrasight Mobile 5/Volcano. The Philips Volcano will attach to the GE Mac-Lab system in the CathLab which is currently being built. This piece will allow the Physician to be able to see the amount of blockage there is at any point in the artery. This will enable AVAMC to do interventional heart studies for the local Veterans, so they don’t need to travel to another facility to get this care.
1. SERVICES:
This will include all pieces of the system needed to perform a Cardiac Catheterization, Stent Placement, Calculation of Blockage and other Interventional Studies. All installations shall follow the guidelines of The Joint Commission, NFPA, CDRH, VAMC. All work will Take place during normal business hours of 8-5, unless prior arrangements have been agreed upon. There will be no work conducted on any Government Holiday or after hours unless there is mutual Agreement between the COR and the installation team of Philips. All work must be Turn-key from the vendor.
Salient Characteristics:
Combined modalities on a single platform to provide a comprehensive view of the targeted vessel, these include:
Intravascular Ultrasound (IVUS) which provides detailed images of the vessel’s interior to assess size, lesions, or plaques.
Instantaneous Wave Free Ratio (iFR) and Fractional Flow Reserve (FFR) which measure blood flow and pressure within vessels to evaluate significance of a blockage.
Angiography co-registration which integrates iFR and IVUS data with an angiogram, allowing the physician to map real-time pressure profiles and vessel measurements directly onto the x-ray image.
Integration with GE and/or Philips therapy systems to reduce data entry errors 9.7” diagonal monitor 1 CPU processor with 2/3 GHz DICOM compatible Windows 10 operating system
The following is the equipment to be installed:
1) Volcano/Intrasight Mobile 5 With Cart
Performance Monitoring Clinical Engineering will monitor the install to ensure everything is being installed as planned, timely, and that will be done by the Government’s appointee.
Place of Performance.
The Place of performance will be located at 6010 Amarillo Blvd West, Amarillo, Texas 79106, BLDG 1, 4th Floor.
1. Responses shall include:
1. Business Name
1. Business Address
1. Point of Contact
2. Name
2. Phone Number
2. E-mail Address
1. SAM UID Number
1. Currently registered in SAM (Yes or No). If Yes, provide expiration date.
1. NAICS code
1. Business Size: Small or Large
1. Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc.
1. GSA or VA FSS Contract Number, if applicable
Please include Authorization Letter from Philips Healthcare Solutions indicating that Vendor has all certifying personnel and authorization to supply this specific equipment.
All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.
1. Send responses to both the Contract Specialist and the Contracting Officer.
Contract Specialist: Mr. Rafael Rodriguez at
Rafael.Rodriguez2@va.gov
Responses in the email subject line shall state: 36C25726Q0160 , Sources Sought Notice Responses due date: 12/12/2025- 3PM CT DISCLAIMER: This notice is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this notice.
Page 1 of Page 1 of
File details come from the government source that posted it. Updated .