36C25720Q0369-014.docx
DOCX document Posted
- Attached to
- 6515--NTX Z 0NE PRO Ultrasound System
- Solicitation number
- 36C25720Q0369
About this file
36C25720Q0369 36C25720Q0369.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25720Q0369-015.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Special Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
GENERAL INFORMATION
ADDITIONAL INFORMATION
* = Required Field Contract Opportunity Special Notice NTX Z 0NE PRO Ultrasound System 78229 36C25720Q0369 N 334510 Department of Veterans Affairs VISN17 Network Contracting Activity 7400 Merton Minter Blvd. (10N17/90C) San Antonio TX 78229 Susan Flores Susan.flores2@va.gov https://www.va.gov https://www.va.gov Susan.flores2@va.gov Susan.Flores2@va.gov The Department of Veterans Affairs intends to award a firm-fixed-price contract Alliant Healthcare, in accordance with VAAR 819.7007 – Sole Source awards to a verified service-disabled Veteran owned small business (SDVOSB).
The North Texas VA Medical Center requires the following Mindray Zonare equipment:
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2.00 |
| EA |
Z.One Pro Ultrasound System: DICOM, Wireless and Rechargeable Battery included: Cold Boot-up time 30 sec, Dramatically improved processing power, Modes: 2D/B,CD, PDI, M, PW, HPRF, Triplex, frequency compounded, spatial compounded, and Tissue Harmonic Imaging, Auto-Opt with ZST- Instantly equalizes tissue gain and brightness.
LOCAL STOCK NUMBER: Z037-00
| 2.00 |
| EA |
C4-1 Curved Array Transducer (4-1 MHz) Primary Applications
LOCAL STOCK NUMBER: Z119-30
| 2.00 |
| EA |
L10-5 Linear Transducer (10-5 MHz) Primary Applications: Thyroid, Breast, Scrotum, Pediatric Hips, Superficial Parts, Needle Guided Procedures. The transducer offers six frequencies including two for 2D and M-Mode, one for Tissue Harmonics, one for Compound Harmonics, and one each for Color/Power and PW Doppler.
LOCAL STOCK NUMBER: Z102-30
| 2.00 |
| EA |
P4-1c Phased Array Transducer (4-1 MHz) Primary Applications: Cardiac, Abdominal Vascular, Transcranial Imaging. The transducer offers fourteen frequencies within 2D and M-Mode, Tissue Harmonics, Color/Power, PW Doppler, Compound Harmonics, and Compound Imaging. Up to 30 cm penetration.
LOCAL STOCK NUMBER: Z108-30
| 1.00 |
| EA |
z.one ultras Smart-Cart Upgrade Promotional Credit
LOCAL STOCK NUMBER: Z1-ULTRACREDIT
| 2.00 |
| EA |
Ultrasound Care Comprehensive POC 5 years Provides transducer accidental damage (standard transducers only), printer, wireless and battery coverage during the five year warranty. Transducer replacements limited to one transducer damage event per year during the 5-warranty period. Provides one battery replacement per 24-month period, not to exceed 3 battery replacements within during coverage period. “Covers B/W Printer and wireless adaptor when purchased directly from Mindray. Ref Z621-10
LOCAL STOCK NUMBER: 803-070248-00
| 2.00 |
| EA |
Z1Pro 4 Year Parts only warranty.
LOCAL STOCK NUMBER: 803-011626-00
This is not a request for quote. However, all interested SDVOSBs are encouraged to submit their capability statement if the brand name requirement can be met along with an authorized reseller letter from Mindray. This justification will be posted after award in accordance with FAR 6.305.
All responses must be submitted by email to susan.flores@va.gov by April 3, 2020, at 9:00am CST.
See attached document: P03-Redacted JA.