36C25219B0059-003.pdf

PDF 8 MB Posted

Attached to
537-15-102 Security Camera System Replacement Federal contract opportunity
Solicitation number
36C25219B0059
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

36C25219B0059 537-15-102 Drawings.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 537-15-102 Security Camera System Replacement, newest first.
File Type Posted
36C25219C0236-000.docx DOCX document
36C25219B0059-0003001.pdf PDF
36C25219B0059-0003000.docx DOCX document
36C25219B0059-0002001.pdf PDF
36C25219B0059-0002002.pdf PDF
36C25219B0059-0002000.docx DOCX document
36C25219B0059-0001001.pdf PDF
36C25219B0059-0001000.docx DOCX document
36C25219B0059-005.pdf PDF
36C25219B0059-004.pdf PDF
36C25219B0059-002.pdf PDF
36C25219B0059-001.docx DOCX document
36C25219B0059-000.docx DOCX document
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOUTH DAMEN AVENUE

O G

D

EN

AVEN

U

ET

A Y

L O

R S

T R

E E

T

P O

L K

S T

R E

E T

= 2005 =

BUILDING

OFFICE

GARAGE

V.B.A.

BLDG 30

BLDG 11BBLDG 11A

BLDG 1

BLDG 1A

BLDG 1B

BLD

G

BLDG 40

BLDG

TEMP.

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com 41

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

GI-001

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

GENERAL PROJECT INFORMATION

TECHNOLOGY SHEET INDEX

GI-001 GENERAL PROJECT INFORMATION

T-000 TECHNOLOGY COVER SHEET

T-001 SITE PLAN

T-002 WORK AREAS

T-1-1 BUILDING 1 - FIRST FLOOR TECHNOLOGY PLAN

T-1-2 BUILDING 1 - SECOND FLOOR TECHNOLOGY PLAN

T-1-3 BUILDING 1 - THIRD FLOOR TECHNOLOGY PLAN

T-1-4 BUILDING 1 - FOURTH FLOOR TECHNOLOGY PLAN

T-1-5 BUILDING 1 - FIFTH FLOOR TECHNOLOGY PLAN

T-1-6 BUILDING 1 - SIXTH FLOOR TECHNOLOGY PLAN

T-1-7 BUILDING 1 - SEVENTH FLOOR TECHNOLOGY PLAN

T-1-8 BUILDING 1 - EIGHTH FLOOR TECHNOLOGY PLAN

T-1-9 BUILDING 1 - NINTH FLOOR TECHNOLOGY PLAN

T-1-10 BUILDING 1 - TENTH FLOOR TECHNOLOGY PLAN

T-11-30-1 BUILDINGS 11 & 30 - FIRST FLOOR TECHNOLOGY PLAN

T-11-30-2 BUILDINGS 11 & 30 SECOND FLOOR TECHNOLOGY PLAN

T-11-30-3 BUILDINGS 11 & 30 - THIRD FLOOR TECHNOLOGY PLAN

T-11-30-4 BUILDINGS 11 & 30 - FOURTH FLOOR TECHNOLOGY PLAN

T-11-30-5 BUILDINGS 11 & 30 - FIFTH FLOOR TECHNOLOGY PLAN

T-11-30-6 BUILDINGS 11 & 30 - SIXTH FLOOR TECHNOLOGY PLAN

T-11-30-7 BUILDINGS 11 & 30 - SEVENTH FLOOR TECHNOLOGY PLAN

T-40-1 BUILDING 40 - FIRST FLOOR TECHNOLOGY PLAN

T-40-2 BUILDING 40 - SECOND FLOOR TECHNOLOGY PLAN

T-40-3 BUILDING 40 - THIRD FLOOR TECHNOLOGY PLAN

T-40-4 BUILDING 40 - FOURTH FLOOR TECHNOLOGY PLAN

T-40-5 BUILDING 40 - FIFTH FLOOR TECHNOLOGY PLAN

T-40-6 BUILDING 40 - SIXTH FLOOR TECHNOLOGY PLAN

T-40-7 BUILDING 40 - SEVENTH FLOOR TECHNOLOGY PLAN

T-P-1 PARKING GARAGE - FIRST LEVEL TECHNOLOGY PLAN

T-200 ENLARGED PLANS - TECHNOLOGY

T-201 ENLARGED PLANS - TECHNOLOGY

T-202 ENLARGED PLANS - TECHNOLOGY

T-203 ENLARGED PLANS - TECHNOLOGY

T-204 ENLARGED PLANS - TECHNOLOGY

T-300 TECHNOLOGY DETAILS

T-400 TECHNOLOGY RISER DIAGRAM

T-401 TECHNOLOGY RISER DIAGRAM

T-402 TECHNOLOGY RISER DIAGRAM

T-500 TECHNOLOGY SCHEDULES

T-501 TECHNOLOGY SCHEDULES

T-600 TECHNOLOGY EQUIPMENT LIST

LOCATION

NOT TO SCALE

VICINITY

NOT TO SCALE NORTH

SITE SITE

SITE PLAN

NOT TO SCALE NORTH NORTH

PROJECT SUMMARY:

BUILDING DATA:

TYPE OF WORK:

OCCUPANCY TYPE:

CONSTRUCTION TYPE:

TOTAL NUMBER OF FLOORS:

NUMBER OF FLOORS ABOVE GRADE:

FIRE PROTECTION SYSTEM:

REQUIRED BUILDING CODES AND

STANDARDS:

SECURITY CAMERA UPGRADE

I-2-HOSPITAL

1-B, NONCOMBUSTIBLE,PROTECTED (NFPA TYPE II - 222)

FULLY SPRINKLERED

VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING

CODES AND STANDARDS AS A MINIMUM:

INTERNATIONAL BUILDING CODE (IBC)

NFPA 101 LIFE SAFETY CODE

NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000

AND NFPA 900

OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA)

STANDARDS.

VA SEISMIC DESIGN REQUIREMENTS, H-18-8

NATIONAL ELECTRICAL CODE (NEC)

ENERGY POLICY ACT OF 2005 (EPACT)

FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE

BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)

EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL

ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT.

REPLACE THE SECURITY SYSTEM THROUGH THE CAMPUS

E

E

D

S D

TAT

E

U N

T I

T N

R P

E A

M T

E

FO

V

A F

S O

I R

E

M

C A

N

R S

I A

F F

A

S

ET RA

DEPT. OF VETERAN AFFAIRS

VA PROJECT NUMBER:

OCULUS INC. PROJECT NUMBER:

JESSE BROWN VA MEDICAL CENTER

820 S. DAMEN AVENUE, CHICAGO, IL 60612

SECURITY CAMERA CORRECTIONS

537-15-102

25515-IL05.00

TECHNOLOGY SYMBOL LIST

SYMBOL: DESCRIPTION: NOTE:

EQUIPMENT LIST

ABBREVIATION:

TECHNOLOGY ABBREVIATION KEY

ENTRANCE FACILITYEF-#

MAIN CROSS-CONNECTMC-#

TELECOMMUNICATIONS ROOMTR-#

ABOVE FINISHED FLOORAFF

BELOW FINISHED CEILINGBFC

CONDUITC

SIMILARSIM

TYPICALTYP

MOUNTING HEIGHT ABOVE FINISHED FLOOR+#

JUNCTION BOXJ-BOX

ABBR: DESCRIPTION:

UNLESS NOTED OTHERWISEUNO

INFORMATION RESOURCE MANAGEMENTIRM

TECHNOLOGY GENERAL NOTES:

1. SC-CAB-1 INDICATES GENERAL TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS

"EQUIPMENT LIST ABBREVIATION"

2. REFER TO GENERAL TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL

DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.

TECHNOLOGY MOUNTING SUBSCRIPT KEY:

A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH

H MOUNT ORIENTED HORIZONTALLY

L MOUNT IN CASEWORK

M MOUNT IN MODULAR FURNITURE

S MOUNT IN SURFACE RACEWAY

A SLASH IS USED BETWEEN TWO SUBSCRIPTS, e.g., A/H.

BELOW IS THE GENERAL SCOPE OF WORK DEPICTED ON THESE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR ALL WORK INDICATED ON THE DRAWINGS AND IN THE SPECIFICATION REGARDLESS IF IT IS DISCUSSED IN THE

GENERAL SCOPE OF WORK LISTED BELOW.

• PROVIDE NEW VMS SOFTWARE, LICENSING, AND SERVER

• PROVIDE NEW FIBER OPTIC CABLING TO 7TH FLOOR BIOMED DATA CENTER AND PARKING GARAGE OFFICE

• PROVIDE NETWORK ELECTRONICS WHERE INDICATED

• PROVIDE NEW CAT 6 CABLING WHERE INDICATED

• REPLACE EXISTING CAMERAS

THE SCOPE OF WORK WILL BE DIVIDED INTO MULTIPLE PACKAGES BASED ON THE WORK AREAS SHOWN ON SHEET T-002. REFER TO SPECIFICATION SECTION 01 00 00 GENERAL REQUIREMENTS, 1.2 STATEMENT OF BID ITEMS

FOR DESCRIPTION OF BID ITEMS AND DEDUCT ALTERNATES.

TECHNOLOGY SCOPE OF WORK:

TECHNOLOGY RENOVATION NOTES:

THESE NOTES APPLY TO ALL TECHNOLOGY SHEETS AND TRADES.

1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. REVIEW EXISTING CONDITIONS AND REPORT ANY CONFLICTS

BEFORE STARTING WORK.

2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. REVIEW EXISTING CONDITIONS

AND REPORT ANY CONFLICTS WITH NEW WORK BEFORE STARTING WORK.

3. REVIEW THE AVAILABLE CLEARANCES FOR CONDUITS BEFORE FABRICATION. RISES AND DROPS MAY BE

NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS.

4. EACH CONTRACTOR SHALL CUT AND PATCH ROOFS, WALLS, AND FLOORS ASSOCIATED WITH THEIR

WORK.

5. THE CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS, CEILING TILES, AND

CEILING GRIDS ASSOCIATED WITH THEIR AREAS OF WORK.

6. WHERE EXISTING TECHNOLOGY SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR

DUCTWORK.

TECHNOLOGY SEQUENCING NOTES:

THESE NOTES APPLY TO ALL TECHNOLOGY SHEETS AND TRADES.

1. THE TECHNOLOGY DRAWINGS DEPICT THE INTENT OF THE FINAL DESIGN. THE TECHNOLOGY DRAWINGS DO NOT DEPICT THE MEANS AND METHODS TO MEET THE REQUIREMENTS OF THE SEQUENCING CRITERIA.

2. REVIEW PROJECT SEQUENCING TO COORDINATE DEMOLITION WORK, OUTAGES,ETC. WITH AFFECTED

ADJACENT AREAS.

3. SEQUENCE DEMOLITION WORK TO MINIMIZE DOWNTIME.

1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR

ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATIONS DETAIL

ON THIS PAGE FOR ADDITIONAL INFORMATION.

2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.

UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN

MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON

BUILDING STRUCTURE.

3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM

OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE

OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE

ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.

4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO

MAKING THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR

CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.

5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO ELECTRICAL

AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION DEVICES ON

EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN ADVANCE BY

THE OTHER CONTRACTOR.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL

BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF

THROUGH-PENETRATION FIRESTOPS. REFER TO 28 05 03 FOR ADDITIONAL INFORMATION

AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.

8. REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OF

TELECOMMUNICATIONS WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION.

REPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS

CONTRACTOR.

9. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND

EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL

DEVICES IN CEILING TILE PATTERN. SMOKE DETECTORS AND OCCUPANCY/VACANCY

SENSORS SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR

RETURN GRILLE.

10. ALL CONDUCTORS SHALL BE COPPER, EXEPT WHER NOTED.

11. ALL ELECTRICAL ITEMS SHALL BE INSTALLED BY A LICENSED ELECTRICAL CONTRACTOR IN

THE STATE A ILLINOIS. A WORK SHALL BE PREFORMED BY A LICENSED JOURNEYMAN OR

SUPERVISED APPRENTICE.

12. CONTRACTOR SHALL USE GROUND PENETRATING RADAR TO SCAN ALL FLOORS PRIOR TO

CORING HOLES. CORES SHALL BE SPACED AT 12" ON CENTER AND SHALL NOT PENETRATE

THE REBAR EMBEDDED WITHIN THE SLAB.

13. ALL VERTICAL RUNS OF CONDUITS SHALL BE SUPPORTED TO A FREE STANDING STEEL

SUPPORT SYSTEM DESIGNED TO TRANSFER THE WEIGH OF THE CONDUIT AND

CONDUCTORS TO THE FLOOR.

14. WHEN CUTTING AND PATCHING EXISTING WALLS, FLOOR AND CEILINGS THE INSTALLED

CONDITIONS AND FINISHES SHOULD MATCH THE EXISTING CONDITIONS AND FINISHES

PRIOR TO MODIFICATIONS TO THE WALL, FLOORS AND CEILINGS.

15. ALL CONDUITS WITHIN THE CONFINED SPACE BELOW THE FIRST FLOOR SHALL BE RGS

TYPE.

16. ALL WORK IN CONFINED SPACE SHALL BE IN CONFORMANCE WITH VA AND OSHA

REQUIREMENTS.

17. CONDUIT ROUTING WITHIN THE CONFINED SPACE WILL REQUIRE MULTIPLE JOGS AND

ELEVATION CHANGES TO WORK AROUND EXISTING UTILITIES.

18. THE VA HAS DETERMINED THAT THE CRAWL SPACE IS A OSHA PERMIT REQUIRED

CONFINED SPACE.

19. ON SITE STORAGE OF MATERIAL IS NOT PERMITTED.

TECHNOLOGY INSTALLATION NOTES:

1. THE EXISTING CCTV SYSTEM TO REMAIN OPERATIONAL DURING THE INSTALLATION OF THE NEW

SYSTEM. THE SYSTEM SHALL NOT BE DISRUPTED UNLESS COORDINATED IN ADVANCE WITH THE

OWNER AND ENGINEER AND AT THEIR DISCRETION ON DATE AND TIME.

2. REFER TO THE DRAWINGS FOR THE LOCATIONS OF THE NEW HEADEND EQUIPMENT AND THE

EXISTING EQUIPMENT LOCATIONS.

TECHNOLOGY PHASING NOTES

GENERAL NOTES:

1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT. REFER

TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION

AND ITEMS.

2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON THE

SHEET INDEX. REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL INFORMATION.

3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE

KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL

INFORMATION.

TECHNOLOGY SYMBOL NOTES:

1. REFER TO CLOSED CIRCUIT (CCTV) INDIVIDUAL CAMERA REQUIREMENTS SCHEDULE ON T-500

SERIES DRAWINGS AND CAMERA TYPE SCHEDULE ON T-600 FOR ADDITIONAL INFORMATION.

SYMBOL SUBSCRIPT INDICATES FLOOR NUMBER-CAMERA NUMBER. A CAMERA HEIGHT

IDENTIFIES THE HEIGHT FROM THE FLOOR TO THE CENTER OF THE CAMERA LENS. NO HEIGHT

REFERS TO MOUNTING THE CAMERA ON THE CEILING. REFER TO THE INDIVIDUAL CAMERA

SCHEDULE AND THE INDIVIDUAL CAMERA TYPE SCHEDULE FOR ADDITIONAL INFORMATION.

2. EXISTING TO BE REPLACED.

3. NEW CAMERA LOCATION.

4. CAMERA SUBSCRIPTS: A=ANALOG, IP=ETHERNET PROTOCOL

CABLE TRAY, CHANNEL TRAY, BASKET TRAY

LADDER RACK

WIDTH X HEIGHT

WIDTH X HEIGHT

DIAMETERø C CONDUIT

CONDUIT DOWN

CONDUIT UP OR UP/DOWN

CONDUIT SLEEVE

CONTINUATION

1., 3.

1., 2. 4.N/A

N/A

EXISTING CAMERA

NEW CAMERA

N/A

CAMERA TO BE DEMOLISHED

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

VIEW NAME

1/8" = 1'-0"

M101

T101

SIM

DETAIL REFERRED TO BY ELEVATION

SHEET DETAIL IS LOCATED ON

INDICATES SIMILAR DETAIL

REFERENCED IN MULTIPLE LOCATIONS

SIM

INDICATES SIMILAR DETAIL

REFERENCED IN MULTIPLE LOCATIONS

LEVEL NAME

10' - 0" HEIGHT ABOVE

PROJECT 0' - 0"

1 INDICATES NOTE USED TO DESCRIBE

ADDITIONAL INFORMATION ABOUT

WORK REQUIRED, SPECIFIC TO THE

SHEET AND/OR DETAIL

N

O R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE KEY:

NEW WORK BY THIS CONTRACTOR

(DARK SOLID LINE)

NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR

(DARK LONG DASHED LINE)

NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN

(LIGHT SOLID LINE)

EXISTING TO BE REMOVED BY THIS CONTRACTOR

(DARK SHORT DASHED LINE)

TEMPERATURE CONTROLS CONTRACTORT.C.C.

SECURITY CONTRACTORS.C.

ASBESTOS ABATEMENT CONTRACTOR

FIRE PROTECTION CONTRACTORF.P.C.

AUTOMATIC TEMPERATURE CONTROL CONTRACTORA.T.C.

HEATING CONTRACTORH.C.

PLUMBING CONTRACTORP.C.

GENERAL CONTRACTORG.C.

MECHANICAL CONTRACTORM.C.

VENTILATION CONTRACTORV.C.

ELECTRICAL CONTRACTORE.C.

A.C.

CONTRACTOR ABBREVIATION KEY

ABBR: DESCRIPTION:

TECHNOLOGY CONTRACTORT.C.

CONTACT PERSONS:

PROJECT MANAGER

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

TECHNOLOGY ENGINEER

MEDICAL EQUIPMENT ENGINEER

ACOUSTICAL ENGINEER

JEFF BURTON

JEFF BURTON

DESCRIPTION: PERSON:

M A

X

20" MAX.

M A

X

20"-25" MAX.

M A

X

M

IN

. 4

M A

X

M A

X

10" MAX. 10"-24" MAX.

ADA GUIDELINES - FRONT ACCESS

ADA STANDARDS FOR ACCESSIBLE DESIGN

INSTALL ABOVE COUNTER

DEVICE AT 44" ABOVE

FINISHED FLOOR.

INSTALL ABOVE COUNTER

DEVICE AT 40" ABOVE

FINISHED FLOOR.

INSTALL DEVICE AT 18"

ABOVE FINISHED FLOOR.

ADA GUIDELINES - SIDE ACCESS

INSTALL DEVICE OR AT 44"

ABOVE FINISHED FLOOR.

INSTALL DEVICE OR AT 42"

ABOVE FINISHED FLOOR.

TECHNOLOGY DEMOLITION NOTES:

1. THE TECHNOLOGY DRAWINGS INDICATE GENERAL AREAS WHERE EXISTING TECHNOLOGY

ITEMS TO BE REMOVED. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF WORK

REQUIRED AND DO NOT INDICATE EVERY BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED.

THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING

CONDITIONS.

2. ITEMS (i.e. SPEAKERS, SWITCHES, ETC) REMOVED AND NOT RELOCATED REMAIN THE

PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISPOSAL OF

MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN. (i.e., FOR MAINTENANCE

PURPOSES)

3. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF THE

POWER TO EQUIPMENT, SYSTEMS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER.

CONDUIT CONCEALED IN WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT

AFFECTED BY OTHER CONSTRUCTION.

4. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE CONDUIT IS IN

THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG. WHERE CONDUIT IS RUN

EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS, ETC., SHALL ALSO BE REMOVED.

5. THIS CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER CONTRACTORS AT THE

JOB SITE BEFORE REMOVING EXISTING EQUIPMENT AND INSTALLING NEW ITEMS.

6. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATING EXISTING

CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE INSTALLED IN ALL

REUSED CONDUIT TO ASSURE PROPER GROUND PATH.

7. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A

JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT AND

WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.

8. TECHNOLOGY DEVICES TO BE REMOVED SHALL HAVE ALL CONNECTED WIRING REMOVED TO

THE SOURCE.

9. DEVICES NOT TO BE REMOVED SHALL BE PROTECTED FROM THE ENVIRONMENT, AND ALL

ASSOCIATED CABLE/RACEWAYS ARE TO REMAIN AND BE PROTECTED. T.C. SHALL BE

RESPONSIBLE FOR REPAIR OF ANY INTERRUPTIONS TO PROTECTED DEVICES.

10. REFER TO SPECIFICATIONS SECTION 27 05 00 AND 27 05 05 FOR ADDITIONAL INFORMATION.

TELECOM ROOM REFERENCES

TELECOM ROOM

DETAIL / SHEET

REFERENCE

FLOOR PLAN

REFERENCE ARCH ROOM NUMBER

HC-1 3/T-200 T-1-3 34T1

HC-2 1/T-201 T-1-9 94T1

HC-3 3/T-201 T-11-30-1 1360A

HC-4 1/T-202 T-40-1 16T1

HC-5 3/T-202 T-40-3 36T1

HC-6 1/T-203 T-40-7 76T1

HC-7 3/T-203 T-11-30-1 1240

MC-1 1/T-200 T-1-1 1555

MC-2 1/T-204 T-1-7 7432

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com 41

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-000

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

TECHNOLOGY COVER SHEET

SOUTH DAMEN AVENUE

O G

D

EN

AVEN

U

ET

A Y

L O

R S

T R

E E

T

P O

L K

S T

R E

E T

= 2005 =

BUILDING

OFFICE

GARAGE

V.B.A.

BLDG 30

BLDG 11BBLDG 11A

BLDG 1

BLDG 1A

BLDG 1B

BLD

G

6BLDG 40

BLDG

TEMP.

1-11A-36

1-30-4

1-30-6

1-30-17

1-1A-2 1-1A-26

1-1B-10

1-1B-12

1-1B-9

1-40-17

1-40-16

1-40-15 1-40-23

1-40-22

1-1A-27

1-40-21

1-11A-3

1-11A-31

1-11A-27

7-11A-1

7-11A-4 8-1A-3

1 2

MC-1

(FIRST FLOOR)

HC-1 (THIRD FLOOR)

HC-2 (NINTH FLOOR)

MC-2

(SEVENTH FLOOR)

HC-7

(FIRST FLOOR)

HC-3

(FIRST FLOOR)

HC-4 (FIRST FLOOR)

HC-5 (THIRD FLOOR)

HC-6 (SEVENTH FLOOR)

N

O R HT

1" = 50'-0"1

SITE PLAN

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com 41

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-001

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

SITE PLAN

GENERAL TECHNOLOGY NOTES :

1. CAMERA LOCATIONS SHOWN FOR REFERENCE

ONLY. REFER TO INDIVIDUAL FLOOR PLANS FOR

ADDITIONAL INFORMATION.

2. REFER TO T-600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

3. REFER TO T-400 SERIES DRAWINGS FOR CCTV

RISER DIAGRAM.

4. REFER TO T-500 SERIES DRAWINGS FOR

INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE.

5. ALL CAMERAS ARE ON GROUND/FIRST FLOOR

UNLESS NOTED OTHERWISE.

6. ALL CAMERAS AND ASSOCIATED EQUIPMENT TO

REMAIN OPERATIONAL UNTIL REPLACEMENT IN

LOCAL WORK AREA IS COMPLETE. PROVIDE

DRIVERS AND CODECS AS NEEDED.

KEYNOTES :

1. REFER TO SHEET T-11-30-7 FOR EXACT CAMERA

LOCATION.

2. REFER TO SHEET T-1-8 FOR EXACT CAMERA

LOCATION.

7424A

7423A

7437A 74E1

7447A

P-7

P-8

NO

C7403 74E2

7433A

NO 2

74487440

74037401

7400 7402

7412A

7421A

7422A

74307429

TOILET

TOILET

TOILET

ELECTRICAL

FIRE CT

FIRE CLOSET

ELEVATOR

ELEVATOR

OFFICE

SUPPLY SPECIALIST

STAIR

CORRIDOR ELECTRICAL

BIOMED SHOP

MED TEAM

TOILET

OFFICE

SUPPLY

STAIR

REPAIR EQUIPSTORAGE

MENS TOILET

PATIENT EFFECTS UNIFORM EXCHANGESATV

BIOMED

SHOP

HAC

EQUIP STORAGEEQUIP STORAGE

EQUIP STORAGE EQUIP STORAGE

BIOMED

SHOP

TOILET

BIOMED

SHOP BIOMED

SHOP

CART

STORAGE

CABLE RM

REFERENCE BOOK RM

STORAGE

TOILET

BIOMED

CHIEF

ICE M/C

TOILET

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOPSUPV OFFICE

S H

O W

E R

B

IO

-M E

D

WORK AREA 11A

BUILDING 1B

BUILDING 1ABUILDING 30

BUILDING 11B

BUILDING 11A

BUILDING 40

T A

Y L O

R S

T R

E E

T

O G

D

EN

AVEN

U E

P O

L K

S T

R E

E T

SOUTH DAMEN AVENUE

WORK AREA 11B

WORK AREA 30

WORK AREA 40

WORK AREA 1B

WORK AREA 1A

WORK AREA 1

WORK AREA 1

PARKING GARAGE

V.B.A. OFFICE BUILDING

MC-1

(FIRST FLOOR)

MC-2

WORK AREA 1

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com 41

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-002

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

WORK AREAS

N

O R HT

1" = 50'-0"1

WORK AREAS

WORK AREA 1

VMS SOFTWARE, LICENSING, SERVER AND

FIBER OPTIC CONNECTIONS TO 7TH FLOOR

BIOMED DATA CENTER

WORK AREA 1A

69 TOTAL CAMERAS

WORK AREA 1B

51 TOTAL CAMERAS

WORK AREA 11A

82 TOTAL CAMERAS

WORK AREA 11B

36 TOTAL CAMERAS

WORK AREA 30

18 TOTAL CAMERAS

WORK AREA 40

47 TOTAL CAMERAS

N

O R HT

1/16" = 1'-0"2

BUILDING 1A - PARTIAL SEVENTH FLOOR PLAN

1541A

1575B

1545A

C1608

NO S5

NO S6

NO P1

NO P2

C1511

C1404

1491A

C1102

C1101

C1401

C1403

C1402

C1405

C1407

C1406

C1409

C1445

1407 1408 1409

1410A

1459A

NO 2

1451 1452 1453

NO P7

NO P8

14E4

NO 1

NO P3

NO P4

1462 1464

14E6

1475C

1475A 1475

1470G1470F1470E1470D1470C1470B

1470A

C1411

1431A

1431B

1431C

C1408

1443 1440

1470R 1470Q 1470P 1470N 1470M 1470L

1470H

1470J

1470K

1491B

C1501

1507 1505

NO 5

14E7

1499A

1498149614941492

C1507

C1606

C1510

C1505

1639A

P-27 16E1

NO 13

C1607

P-26

16H5

1554B

1540B1540A

1542A

1544A

C1505

C1504

C1103

1541B

C1116

C1509

1561 1563 1565

1558 1560 1562 1564

1581A

15E2

NO 3

C1506

C1508

C1502

C1503

1528B 1528A

1530A 1530B

1533A

15E4

1538A

NO 14

1539A

1538F

1538B

1538E 1538D

1538C

1538G

C1506B

1570A

C1506A

1521A

C1505

1555B

1635A

1602A

1499B

1490A

M1

NO 5A

1436A

NO 2

1410B

C1404

C1404

1570C

14E5

HAC

STORAGE

FIRE CLOSET

PNEUMATIC

TUBE

FAC

FAC

TEL

FIRE

HOSE

CLOSET

CLOSET

FAC

CLOSET

DIGITAL RADIOLOGY

CORRIDOR

TELECOMMUNICATION STAFF OFFICE

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

CORRIDOR

PREP/

RECOVERY

CORRIDOR

TOILET

OUTPATIENT

RADIOLOGY EXAM/

TREATMENT RM

ELECTRICAL

CLEAN SUPPLY

CORRIDOR

ENTRANCE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

WAITING RM

WOMENS TOILET

MENS TOILET

HEALTH VET

CO-ORDR CREDIT UNION

FIRE

CONTROL

PATIENT

ADVOCATE

OFFICE

OPTICAL DISPENSARYTRIAGE

TRIAGE

ELECTRICAL

SWITCH RM

TRIAGE

PHYSICIAN ASSIST

ELECTRICAL

ADDICTION

CONSULT

RM

RECEPTION

CONSULT

RM

ER

OFFICE

ER

OFFICE

ELECTRICAL

VIST

CO-ORDR

CONSULT

RM

HAC

TOILET

TEL

VESTIBULE/STAIR

STAIR

PAC

CO-ORDR

OFFICE

CHIEF

CONSULT

RM

CONSULT

RM

CONSULT

RM

EMS

HOUSE

KEEPING

ELEVATOR

ELEVATOR

TEL

CLOSET

STAIR

ELEVATOR

ELEVATOR

NURSE STATION EMERGENCY RM

EQUIP STORAGE LOUNGE

ELECTRICAL

COMM

OFFICE

SOILED

UTILITY

EXAM RM-7EXAM RM-6EXAM RM-5EXAM RM-4EXAM RM-3EXAM RM-2

ER MGR

ICE MACH

EXAM RM-1

ER HALLWAY

TRAVEL OFFICE

STORAGE

RECEPTION AND

ADMISSIONAMBULATORY

CARE SUPV

OFFICE

CHIEF

AMBULATORY

CORRIDOR

VTS MANAGER

EMS STORAGE

ER STORAGE

TRIAGE

E D ATTENDING

TRIAGE

MEDICAL SUPPORT

TELEPHONE TRIAGE

TOILET

VESTIBULE

AMBULANCE DROP-OFF

EMS

CLEAN SUPPLY CLEAN LINEN

TOILETNEGATIVE PRESSURE RM

EXAM RM-15 EXAM RM-14 EXAM RM-13 EXAM RM-12 EXAM RM-11 EXAM RM-10

MEDS

EXAM RM-8

EXAM RM-9

MENS

TOILET

CONFERENCE RM

WOMENS TOILET

TOILET

ON CALL

ADMIN OFFICE

EXAM RM

ON CALL

STAIR

OFFICE

EXAM RM

EXAM RM

DONATED CLOTHING

STORAGE

EMS LINEN RM

CORRIDOR

PHARMACY IV

STORAGE BIOHAZARD CONTAINER GAS

STORAGE ELEVATOR MECH

ELEVATOR FOYER

MORGUE

ELEVATOR

STAIR

TELECOMMUNICATION RM

ELECTRICAL

TOILET

DOCTOR OFFICEDOCTOR OFFICEDOCTOR OFFICESECRET OFFICE

OFFICE COMP AND

PENS STAFF

WAITING RM

SUPV OFFICE

EXAM RM

EXAM RM

FORENSIC

PSY

FELLOW

MECH RM

VESTIBULE

LOBBY

POLICE

OPERATION

CORRIDOR

CORRIDOR

PREPARATION

SPD CHIEF

CART STAGING

AREA

CHIEF CHAPLAIN

ELEVATOR PIT

STAIR

SECY

VESTIBULE

CHAPEL SACRISTY

CORRIDOR

ELEVATOR

HAC

TOILET

TOILET

ARMORY RM

TOILET

STORAGE

SQUAD RM OFFICE

PHYSICAL

SECURITY

PHYSICAL

SECURITY

EVIDENCE STORAGE

EVIDENCE

OFFICE VIEW

OPERATION CAPTAIN

DEPUTY CHIEF

VESTIBULE

CORRIDOR

CORRIDOR

ATRIUM

CORRIDOR

ELECTRICAL

VESTIBULE

SECY OFFICE

CONFERENCE/

TRAINING RM

CORRIDOR

POLICE CHIEF

POLICE

INVESTIGATION

OFFICE

DOCTOR

OFFICE

RAD

OFFICE RADIOLOGY SCHEDULING

HOLD CELL

HOLD CELL

RADIOLOGY OFFICE

RADIOLOGY

READING RM RADIOLOGY OFFICE

RAD

OFFICE

STAFF RADIOLOGY

SVC ULTRASOUND

TOILET

SPD SUPV

OFFICE

SPD RECEIVING

STORAGE

SECY OFFICE

RADIOLOGY SVC

CONFERENCE RM

FAN RM

STORAGE

COMPUTER CABINET

OPERATION MGR

RADIOLOGY SVC

CHIEF RADIOLOGY

ELECTRICAL

CLOSET

TELEPHONE CLOSET

HAC

STAIR

WAITING RM

CONSULT RM - 1

CONSULT RM - 2

GOWNED WAITING

COPY

RECEPTION

TECH WORK

TOILET

MENS

CHANGING

WOMENS

CHANGING

INPT

HOLDING

CORRIDOR CORRIDOR

CORRIDOR

CLEAN

CLEAN

SUPPLY

CORRIDOR

HAC

FIRE ALARM

CORRIDOR

GAS CYLINDER

STORAGE

EMS STORAGE

CT IMAGING RM - 2

CONTROL RM - 2 TOILET

CONTROL RM - 1 TOILET

CT IMAGING RM - 1

ELECTRICAL RM

RADIOLOGY /

FLUOROSCOPIC RM

TOILET

MECH

ULTRASOUND RADIOLOGY SUPPLY

DIGITAL RADIOLOGY

ELECTRICAL

READING RM

SWITCHGEAR RM

TOILET

STAIR

I R READING

RM

COMMUNICATIONS

ANTE RM

EQUIP RM

CONTROL RM - 3

SPECIAL

PROCEDURES

INTERVENTIONAL

CORRIDOR

STAIRWELL

VESTIBULE

VESTIBULE

CORRIDOR

CLOSET

VESTIBULE

VESTIBULE

ELECTRICAL

CLOSET

OPTICAL

WAITING RM

CORRIDOR

ATS RM

ELECTRIC CLOSET

ETO

SVC

SPD

STAFF

OFFICE

STEAM

STERILIZER

CART

WASH

ELEVATOR

MACH RM

ELECTRICAL

RM

SOILED RECEIVING /

DECONTAM

SALLY

PORT

STAFF

LOUNGE

STAFF

LOCKER

SECURED

ITEMS

FIRE COMMAND

CENTER

ESCORT WAITING

RM

WHEELCHAIR

WASH

CHAPLAIN

OFFICE

ETO

RM

MANUAL EQUIP

WASHSTAFF

LOCKER

BLESSED

SACRAMENT

ROLLING SHUTTERROLLING SHUTTER

OVER HEAD DOOR

FEC

LOUVER

LOUVER

1-1A-2

1-1A-25

1-1A-21

1-1A-3

1-1A-18

1-1A-24

1-1A-26

1-1A-41-1A-20

1-1A-19

1-1A-16

1-1A-17

1-1A-22

1-1A-5 1-1A-6

1-1A-1

1-1A-14

1-1A-15

1-1A-13

1-1B-16

1-1A-11

1-1A-9

1-1A-10

1-1A-23

1-1A-7

1-1B-6

1-1B-17

1-1B-13

1-1B-8

1-1B-9

1-1B-14

1-1B-12

1-1B-10

1-1B-7

1-1B-3

1-1B-2

1-1B-15

1-1B-4

1-1B-5

1-1B-18

MC-1

LOCATION OF EXISTING

NETWORK VIDEO RECORDER

AND MONITOR

IP

IP IP

IP

IP

IP

IP

IP

IP

IP IP

IP

IP

IP

IP

A

A

1-1A-28

1-1A-27

1-1A-8

1-1B-1

A

A

A

A

IP POLE

IP

A

IP

IP

A

A

IP

IP

IP

A

A

IP

A

IP

A

B U

IL

D

IN

G

B U

IL

D

IN

G

BUILDING 40

BUILDING 1

ALL CAMERAS SHALL BE SERVED

FROM MC-1 UNLESS NOTED

OTHERWISE.

ALL CAMERAS SHALL BE SERVED

FROM IRM CLOSET HC-1 UNLESS

NOTED OTHERWISE. REFER TO T-

1-3 FOR HC-1 LOCATION.

T-200

1-1B-19

1-1B-20

LOCATION OF (2) EXISTING VIDEO

RECORDERS AND MONITORS

N

O R HT

1/16" = 1'-0"1

BUILDING 1 - FIRST FLOOR TECHNOLOGY PLAN

DAMEN AVENUE

O G

D

EN

AVEN

U E

T A

Y L O

R S

T R

E E

T

P O

L K

S T

R E

E T

1B

1A30

11A

11B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com

SITE PLAN

NORTH

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-1-1

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

BUILDING 1 - FIRST FLOOR

TECHNOLOGY PLAN

GENERAL TECHNOLOGY NOTES :

1. REFER TO T-600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

2. REFER TO T-400 SERIES DRAWINGS FOR CCTV

RISER DIAGRAM.

3. REFER TO T-500 SERIES DRAWINGS FOR

INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE.

4. ALL EXISTING IP CAMERAS ARE TO BE

REPLACED. RE-USE EXISTING DATA OUTLET AND

CONFIGURE NETWORK AS REQUIRED TO

SUPPORT NEW CAMERA. REFER TO INDIVIDUAL

CAMERA REQUIREMENTS SCHEDULE ON T-500

SERIES DRAWINGS FOR ADDITIONAL

INFORMATION.

5. ALL EXISTING ANALOG CAMERAS ARE TO BE

REPLACED. DEMO EXISTING CABLE

INFRASTRUCTURE BACK TO SOURCE. PROVIDE

NEW CAT 6 CABLE. PROVIDE NEW OR EXTEND

EXISTING CONDUIT AS NECESSARY TO ROUTE

CAT 6 CABLE TO AREA SERVING IRM CLOSET.

REFER TO INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE ON T-500 SERIES DRAWINGS FOR

ADDITIONAL INFORMATION.

6. ALL CAMERAS AND ASSOCIATED EQUIPMENT TO

REMAIN OPERATIONAL UNTIL REPLACEMENT IN

LOCAL WORK AREA IS COMPLETE. PROVIDE

DRIVERS AND CODECS AS NEEDED.

KEYNOTES:

1. EXISTING ANALOG PTZ CAMERA.

2. ABANDONED CAMERA NOT FUNCTIONAL.

PROVIDE NEW CAMERA AND CAT 6 CABLE.

3. EXISTING VISIOWAVE DISCOVERY 2400 UNITS

TO REMAIN OPERATIONAL UNTIL LOCAL WORK

AREA IS COMPLETE. NEW VMS TO VIEW LIVE

VIDEO AND RECORD CAMERAS UTILIZING THE

VISIOWAVE DISCOVERY 2400 ENCODERS.

CONTRACTOR TO PROVIDE DRIVERS TO

INCORPORATE INTO VMS PLATFORM AS

NEEDED. WHEN REMOVED FROM SERVICE, THIS

CONTRACTOR IS RESPONSIBLE TO EXPAND

TOTAL NET STORAGE CAPACITY OF NEW VMS

ARCHIVE SERVERS LOCATED IN BIOMED DATA

CENTER WITH ADDITIONAL ARCHIVE SERVERS

BCD215-GN-120-90TB OR APPROVED EQUAL.

4. REMOVE CAMERA AND CABLE BACK TO

SOURCE. DO NOT REPLACE WITH NEW.

5. INSTALL 6-STRAND MM FIBER IN NEW 2"

CONDUIT FROM MC-1 TO ROOM 1541B. ROUTE

FIBER TO BUILDING 5 IN NEW AND EXISTING

PATHWAYS. REFER TO DRAWING T-P-1 FOR

MORE INFORMATION. COORDINATE WITH

OWNER PRIOR TO INSTALLATION.

6. INSTALL 12-STRAND MM FIBER FROM MC-1 TO

ROOM 1467 IN NEW 2" EMT CONDUIT. ROUTE

FIBER FROM MC-1 TO 7TH FLOOR MC-2 IN

EXISTING TELECOMMUNICATION RISERS.

COORDINATE WITH OWNER PRIOR TO

INSTALLATION.

PARKING

GARAGE

ELECTRICAL CLOSET

ELECTRICAL CLOSET

CLOSET

CLOSET

CLOSET

OCCUPATIONAL THERAPY

ELECTRICAL CLOSET

FAC

TEL

STORAGE FAC

ELECTRICAL CLOSET

COAT CLOSET STORAGE

TOILET

STORAGE

STORAGE

MECH RM

CONNECTING

CORRIDOR

ASSOCIATE DIRECTOR PATIENT CARE

CORRIDOR

ELEVATOR

ELEVATOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

OR-6

ELEVATOR

STAIR

OR-5

ELEVATOR

VESTIBULE

OR SUPPORT

OR-3 (LARGE)

OR SUPPORT

PHYSICAL THERAPY

CLINIC

CORRIDOR

CORRIDOR

OCCUPATIONAL THERAPY

KINESIOTHERAPY CLINIC

STORAGE

MENS

TOILET

LOCKER

MENS TOILET

PATIENT RM

WOMENS LOCKER

HAC

WOMENS TOILET

TOILET

OFFICE STAFF

STAIR

WORK RM

OFFICE

PM AND R

SECY STAFF

PM AND R

CHIEF RESIDENT OFFICE DOCTOR OFFICE CONFERENCE RM

OT

OFFICE

KITCHEN ASSESSMENT OCCUPATIONAL THERAPY

ADL RM

STAIRMULTIPURPOSE THERAPYSTORAGEDOCTOR OFFICEDOCTOR OFFICE

CORRIDOR

STORAGE

STORAGE

IRM STORAGE IRM STORAGE

WAITING RM

CORRIDOR

STORAGE

CANTEEN STORAGE

STORAGE

STORAGE

AUTOPSY AREA

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

SOILED UTILITY

TOILET/

SHOWER

MORGUE

CLEAN UTILITY

REFR

MECH SPACE

VOLUNTARY STORAGE

FLEET OPERATION

OFFICE

SUPV OFFICE

ELEVATOR

ELEVATOR

PATIENT ADVOCATE

OFFICE

CORRIDOR

CONFERENCE RM

DIRECTORS STAFF

OFFICE AREA

TELEPHONE CLOSET

STAIR

CORRIDOR

MENS TOILET

TEL

STAIR

DIRECTOR OFFICE

TOILET

STORAGE

ELECTRICALSECRET AREA

LOUNGE /

KITCHEN

ASSOCIATE DIRECTOR SECRET SECRET PI OFFICE STAFF OFFICE

ASST TO

DIRECTOR

AUDITORIUM

ELECTRICAL

CORRIDOR

FELLOW OFFICE

MGR ANALYST

SECY STAFF

OFFICE

PA OFFICE

AD OFFICE

ACOS CLINIC

AFFAIRS

OFFICE

STORAGE

BREAK RM

WOMENS TOILET

COMPLIANCE OFFICER OFFICE

STORAGE

LOBBY

HUMAN

RESOURCES

OFFICE

ELECTRICAL

RECEPTION

VESTIBULEMENS TOILET

STORAGE

WOMENS TOILET UNISEX TOILET

KITCHEN

CORRIDOR

STAIR

CORRIDOR

MECH SPACE

ELEVATOR

FAMILY VIEWING TOILET

STORAGE

STAIR

ELEVATOR

LAB

INJECTION RM

PROCESSING RM

ELECTRICAL

NUCLEAR MEDICINE

SCANNING AREA

TREATMENT RM

CHIEF OF STAFF

ASST

DIRECTOR

STORAGE

AND EQUIP

DRESSING

RMPIV

PIV

PIV

VISUAL

CO-ORDR

TOILET

LOW AND BLIND

VISION

TREATMENT RMSTRESS LABWAITINGCARDIOLOGY TREATMENTNUCLEAR MED

RECEPTION

HAC

FILE RM

NUCLEAR MED

CHIEF

NUCLEAR MED

READING RM

BONE DENSITY

PROCEDURE RM

NUCLEAR MED

OFFICE

STAFF OFFICE

WALL PARTITION CLOSETWALL PARTITION CLOSET

FIRE

CLOSET

FIRE

CLOSET

CLEAN UTILITY

IRM STORAGE

IRM STORAGE

IRM STORAGE

GENERAL

STORAGE

GENERAL

STORAGE

FUTURE

CORRIDOR

UNASSIGNED

OFFICE ASSOCIATE DIRECTOR

EMERGENCY SUBSTATION RM

VESTIBULE

NORMAL

SUBSTATION

RM

ELECTRICAL

CLOSET

OR-4

(LARGE)

STERILE CORE

ANNEX

ELECTRICAL

RM

STERILE

CORE

25E2

2514A

25E1

2460 2479A

2438C 2438A

2438B

2440A

2447A

2600A

C2307

24142412

C2401

C2409

C2404

C2602

C2601

2606 NO 27

NO 13

26E2

NO 26

C2502

C2503

2580A

2521A

NO 3

2535 2537 2539 2541

2547 2559

NO 4

25442540

C2501

2507 2510

C2408

NO P4

NO P3

NO P2

NO P1

2497A

2477A

2449A

2449B

NO P7

NO P8

C2405

NO 1

C2407

NO 2

2413B

2413A

24052403

2408 2410 2418

2446E

C2406

2440 2442

2446D

2444A 24562454

2446A

2446B

C2402

C2403

2459 2482

2492A

NO 5

24E5

2446C

2462A2464

2474A

249024882486 24842480

M-1

NO 5A

2446H

2446F

2446G

2554B

2554A

2520A

2585A

2585B

2585C

2556B

2556A

24E4

R O

O F

R O

O F

R O

O F

R O

O F

2-1B-1

2-1B-3

2-1B-4

2-1B-2

2-1A-5

2-1A-6

2-1A-3

2-1A-22-1A-1

WALL RACK WITH NETWORK SWITCH

CONNECTED TO SERVER IN RETAIL

AREA

2-1-R-2

2-1-R-1

2-1-R-3

2-1-R-5

2-1-R-4

2-1-R-7

2-1-R-6

IPIP

IP

IP

IP

IP

IP

IP

IP

IP

IP

IP

IP

IP

3 3

B U

IL

D

IN

G

B U

IL

D

IN

G

BUILDING 40

BUILDING 1

ALL CAMERAS SHALL BE SERVED

FROM MC-1 UNLESS NOTED

OTHERWISE. REFER TO T-1-1 FOR

IRM CLOSET, MC-1 LOCATION.

ALL CAMERAS SHALL BE SERVED

FROM IRM CLOSET HC-1 UNLESS

NOTED OTHERWISE. REFER TO T-

1-3 FOR IRM CLOSET, HC-1

LOCATION.

DAMEN AVENUE

O G

D

EN

AVEN

U E

T A

Y L O

R S

T R

E E

T

P O

L K

S T

R E

E T

1B

1A30

11A

11B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com

SITE PLAN

NORTH

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-1-2

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

BUILDING 1 - SECOND FLOOR

TECHNOLOGY PLAN

N

O R HT

1/16" = 1'-0"1

BUILDING 1 - SECOND FLOOR TECHNOLOGY PLAN

GENERAL TECHNOLOGY NOTES :

1. REFER TO T-600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

2. REFER TO T-400 SERIES DRAWINGS FOR CCTV

RISER DIAGRAM.

3. REFER TO T-500 SERIES DRAWINGS FOR

INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE.

4. ALL EXISTING IP CAMERAS ARE TO BE

REPLACED. RE-USE EXISTING DATA OUTLET AND

CONFIGURE NETWORK AS REQUIRED TO

SUPPORT NEW CAMERA. REFER TO INDIVIDUAL

CAMERA REQUIREMENTS SCHEDULE ON T-500

SERIES DRAWINGS FOR ADDITIONAL

INFORMATION.

5. ALL EXISTING ANALOG CAMERAS ARE TO BE

REPLACED. DEMO EXISTING CABLE

INFRASTRUCTURE BACK TO SOURCE. PROVIDE

NEW CAT 6 CABLE. PROVIDE NEW OR EXTEND

EXISTING CONDUIT AS NECESSARY TO ROUTE

CAT 6 CABLE TO AREA SERVING IRM CLOSET.

REFER TO INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE ON T-500 SERIES DRAWINGS FOR

ADDITIONAL INFORMATION.

6. ALL CAMERAS AND ASSOCIATED EQUIPMENT TO

REMAIN OPERATIONAL UNTIL REPLACEMENT IN

LOCAL WORK AREA IS COMPLETE. PROVIDE

DRIVERS AND CODECS AS NEEDED.

KEYNOTES:

1. EXISTING CAMERAS CONNECTED TO STAND

ALONE NETWORK. RE-USE EXISTING CAMERAS.

COORDINATE ALL OUTAGES WITH RETAIL STORE

MANAGER PRIOR TO STARTING WORK.

2. EXISTING RETAIL STORE STAND ALONE

NETWORK EQUIPMENT. PROVIDE CAT 6 CABLE

TO MC-1 FOR MULTICAST. CONNECTION OF

CAMERAS TO BOTH RETAIL AND POLICE

SYSTEMS.

3. EXISTING ANALOG PTZ CAMERA.

EX

EX

EX EX

EX

3426A

3475A

3486347934E4

3472C

3472B

3455A

3495A

3497A

3505 3503

3535A 3535B

34E2 3443A3438

3424A

3428A

3432A

3434A

3429A

3427A

3425A

34E1

3485A

3411 3438A

3447A

C3401C3405

36E9

NO13

36E7

C3502

C3503

C3505

3536 3537

NO

3545 3547 3549 3553 3561 3565 3568

NO

3560A

C3501

C3402 C3404

C3403

C3406

C3504

3535C

3534A

P-4

P-3

P-2

P-1

34963501

3475B

3475C

NO

3483 3489 3491 3492 3494

3494A34933490348834843480

3472A3472

3466A

34603454A

3454B

3454345234503444

P-7

P-8

34T1

NO

34433441 3439A3439

NO

34033401

3408 3410 3412

S-5

S-6

3468A

3560B

3595A

3520C

3520B

3520A

34E3

NEPHROLOGY DIALYSIS

CONFERENCE RM AND

PATIENT EDUCATION

HAC

TOILET

MGR

CLINICAL

NUTRITION

MULTIPURPOSE RM

TOILET SOILED

UTILITY

ELECTRICAL CLOSET

TOILETFACELECTRICAL

BACKUP

GENERATOR RM

STORAGE

STORAGE

ELECTRICAL

ELECTRICAL

LINEN CHUTE LINEN CHUTE

STORAGE

STORAGE

REST RM NIC

ELECTRICAL

TOILETVESTIBULE

SUPPLY CLOSET

TOILET

TOILET

TOILET

STORAGE CLOSET

TOILET

TOILET

MENS

SHOWER

ELECTRICAL CLOSET

TELECOM

STORAGE

FAC TOILET

FAC

FIRE CLOSET CORRIDORCORRIDOR

ELECTRICAL UTILITY MECH

STAIR

CORRIDOR

CORRIDOR

CORRIDOR

PHARMACY

NARCOTIC VAULT NIC

SUPV

CLEAN RM

DRUG AREA

MECH RM

FREEZER

STAGING AREA

REFR-1

REFR-2

STAIR

OFFICE

STORAGE

CAN FOOD STORAGE

FOOD

OPERATIONS

ASST

CHIEF

NUTRITION

AND FOOD

SVC OFFICE

CONFERENCE AND OFFICE

N AND FS CALL CENTER

DIETICIAN STAFF

OFFICE CHIEF

NUTRITION AND

FOOD SVC OFFICE

STAIR

PATIENT DINING RM

N AND FS

SERVING KITCHEN

CORRIDOR

NUTRITION AND FOOD

KITCHEN

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CONFERENCE

ROOM

SUPV OFFICE

SUPV OFFICE

REFR WALK-IN

MENS

TOILET

STORAGE

REFR

REFR

REFR

ELEVATOR LOBBY

ELEVATOR

ELEVATOR

ELEVATOR

FOOD

SVC AND

SUPV

ELEVATOR

ELEVATOR

ELEVATOR

HACHAC

CLEAN

UTILITY

LOCKER

KITCHEN

BREAK

STERILE

SUPPLY

STAIR

FELLOWS

CARDIOLOGY ECHO OFFICE

STERILE

SUPPLY

MGR

CARDIOLOGIST

CARDIOLOGIST

OFFICE

CHIEF CARD

PHYSICIAN

OFFICE

PHYSICIAN

CARDIOLOGY

CARDIOLOGY

ATTENDING

OFFICEPROGRAM CLERK

NURSE

PRACTITIONERS

CARDIOLOGY

HAC

NURSE

CARDIAC

CATH LAB

BED RM

BED RM

BED RM

MECH RM

CATH

PROCEDURE

CATH LAB

MECH RM

CARDIAC

CATH LAB

RECEPTIONCARDIOLOGY

HEART STATION

WAITING

TANK RM

STORAGE

DIALYSIS

STORAGE

CARDIO

STORAGESUPPLYDIALYSIS RM

DIALYSIS EQUIPMENT

FILE

STORAGE

SPD SUPPLY

DIALYSIS

SOLUTIONS-B

DIALYSIS

SOLUTIONS-A

STORAGE

STORAGE

FEMALE

IV WORK AREA

WOMENS

TOILET

MECH RM

ELEVATOR

ELEVATOR

CLINIC NUTRITION

TEL

STAIR

DIALYSIS

WAITING

NURSE

STATION

LOCKERLOUNGE

CRASH CART

STORAGE

ECHO LAB

STAIR

EXAM TREATMENT

HOLTER

SCAN

NURSE

OFFICE

SUPV

ICE

DIALYSIS

RM SOCIAL WORK

NURSE

MGR

DIRTY UTILITY

IV RM

MENS TOILET

TRANSFER CO-ORDR

HEMO DIALYSIS

DIR OFFICE

CONSL MGR

MECH RM

HAC

STORAGE

CORRIDOR

FEC

ELECTRICAL

FEC

VESTIBULE

VESTIBULE

ALCOVE

CLOSET

ELECTRICAL CLOSET

ELECTRICAL

CLOSET

ELECTRICAL

CLOSET

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

ROOF

R O

O F

R O

O F

3-1B-1

3-1B-10

3-1B-12

3-1B-9

3-1B-11

3-1B-7

3-1B-8

3-1B-6

3-1B-2 3-1B-3

3-1B-4

3-1B-5

3-1A-2

A

A

3-1B-13

3-1B-14

IP

A

A

A A

A

A

IP

IP

IP

B U

IL

D

IN

G

B U

IL

D

IN

G

BUILDING 40

BUILDING 1

IP

3-1A-1

IP

HC-1

T-200

DAMEN AVENUE

O G

D

EN

AVEN

U E

T A

Y L O

R S

T R

E E

T

P O

L K

S T

R E

E T

1B

1A30

11A

11B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com

SITE PLAN

NORTH

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-1-3

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

BUILDING 1 - THIRD FLOOR

TECHNOLOGY PLAN

N

O R HT

1/16" = 1'-0"1

BUILDING 1 - THIRD FLOOR TECHNOLOGY PLAN

GENERAL TECHNOLOGY NOTES :

1. ALL CAMERAS SHALL BE SERVED FROM IRM

CLOSET HC-1 UNLESS NOTED OTHERWISE.

2. REFER TO T-600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

3. REFER TO T-400 SERIES DRAWINGS FOR CCTV

RISER DIAGRAM.

4. REFER TO T-500 SERIES DRAWINGS FOR

INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE.

5. ALL EXISTING IP CAMERAS ARE TO BE

REPLACED. RE-USE EXISTING DATA OUTLET AND

CONFIGURE NETWORK AS REQUIRED TO

SUPPORT NEW CAMERA. REFER TO INDIVIDUAL

CAMERA REQUIREMENTS SCHEDULE ON T-500

SERIES DRAWINGS FOR ADDITIONAL

INFORMATION.

6. ALL EXISTING ANALOG CAMERAS ARE TO BE

REPLACED. DEMO EXISTING CABLE

INFRASTRUCTURE BACK TO SOURCE. PROVIDE

NEW CAT 6 CABLE. PROVIDE NEW OR EXTEND

EXISTING CONDUIT AS NECESSARY TO ROUTE

CAT 6 CABLE TO AREA SERVING IRM CLOSET.

REFER TO INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE ON T-500 SERIES DRAWINGS FOR

ADDITIONAL INFORMATION.

7. ALL CAMERAS AND ASSOCIATED EQUIPMENT TO

REMAIN OPERATIONAL UNTIL REPLACEMENT IN

LOCAL WORK AREA IS COMPLETE. PROVIDE

DRIVERS AND CODECS AS NEEDED.

KEYNOTES:

1. EXISTING ANALOG PTZ CAMERA.

FEC

FEC

FEC

4615A

4633A

4417C

44E2

4455A

4453A

45184524

4584A

44E6

4581A

45E1

4516A

44E5

4447A

44E3

4624B 4622B

4620B 4618B

4616B

C4610

C4611

C4612

4614A 4616A

4618A 4620A

4622A

4624A

4617A

NO13

4717B

4611 4639

46E1

4619 4635 46H1

4627A

4626A

4625A

4638A 4636A

4634A 4632A

4630 4630A

C4502

C4503

NO

4549B

4549A

45E2

NO

4527453345364537

C4501

C4408

C4404

C4402

C4401

4515A

4402A

P-7

P-8

4453A

P-1

P-2

P-3

P-4

S-5

S-6

4402C 4402B

4402E 4402D

4404 4405

4417A

4417B

NO

4420A

4422 4426 4428

C4403

4401A4401B

44T1

NO

C4405

C4406

C4407

44454446

NO

44524454

44574459

4458A

44E1

4443A

4629A

4545A

44E3

PANORAMIC RM

ALCOVE

ELECTRICAL

CLOSET

CLOSET

MED

CLOSET

SOILED

SPD

CART

HOLDING

TEL/DATA

SOIL SPD

CART HOLDING

SOILED

SPD

CART

HOLDING

INSTRUMENT

PREP

CONTROL RM

BARIATRIC

TOILET

PAT COUNSEL

MENS

TOILET

WOMENS

TOILET

STORAGE

NITROUS TANK

STORAGE

FAC

DUMBWAITER

ELECTRICAL

LINEN CHUTE

CLOSET

SUPPLY

CLOSET

ELECTRICAL

CLOSET

ELECTRICAL

CLOSET

ELECTRICAL

ELECTRICAL

CLOSET

TREATMENT BAY

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

CORRIDOR

CORRIDOR

CORRIDOR

ALCOVE

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

STAIR

HAC

OFFICE 3

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

CORRIDOR

CORRIDOR

STAIR

MICRO BIOLOGY LAB

MECH

MICRO BIOLOGY LAB

LAB MGR

SUPPLY

BLOOD

DRAW AREA

TEL

ELECTRICAL

STAIR

MENS LOCKER

CONFERENCE RM

LOUNGE

STORAGE

WALK

IN REFR

STORAGE

LEAD PATHOLOGIST

PATH AND LAB

MEDICINE OFFICE

HAC

FROZEN

SECTION

ACCESSIONING LAB

LABLABLAB

GYTOLOGY

WOMENS LOCKER

TOILET

WOMENS LOUNGE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

SUPV

OFFICE

LAB OFFICE

TOILET

PLMS

SECY

OFFICE

PATHOLOGIST

OFFICE

UIC PATHOLOGISTS

AND DIRECTOR OF

OPERATIONS OFFICE

PATHOLOGY

RESIDENTS

CLEAN

SUPPLIES

COMPRESSOR RM

NEUROLOGY

OFFICE

NURSE

OFFICE

STAFF LOUNGE

ELEVATOR

ELEVATOR

VASCULAR

OFFICE

STORAGE

ELEVATOR

LOBBY

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

MED OFFICE

LOCKER RM

JANITOR

CLOSET

TOILET TOILET

TOILET TOILET

PATIENT

TOILET

SURGY

MGR

RECOVERY BAY

STAIR

SURGY

TEAM RM

PATIENT

TOILET

OFFICE

MAXILLOFACIAL

NO 4

MAXILLOFACIAL

NO 3 CONE BEAM

MAXILLOFACIAL

NO 1 MAXILLOFACIAL

NO 2 INSTRUMENT

PREP

ORAL SURGY RM

ORAL SURGY RM

CORRIDOR

OFFICE

ENDOSCOPY NO 2

ENDOSCOPY NO 1

STORAGE

CONSULT RM

PERIODONTAL

NO 1

PERIODONTAL

NO 2

INSTRUMENT

PREP

CLEAN LINEN

MECH RM

RECEPTION / ADMISSION

WAITINGWAITING

TEL

STAIR

CORRIDOR

CORRIDOR

CORRIDOR

TRIAGE

INSTRUMENT

PREP

HYGIENIST

OFFICE PREP

TRIAGE

TREATMENT BAYMECH RM

OFFICE

OFFICE

INSTRUMENT

PREP

TEACHING

UNIT

OFFICE

STAIR

TREATMENT BAY

ALCOVE

TREATMENT BAYHYGIENIST

STORAGE

RESIDENT

TEAM RM

MODEL

MAKING

CERAMICS

LAB

LAB

DENTAL EXAM

WALK

IN REFR

ELECTRICAL

CLOSET

STEP DN ISOLATION

PAT RM

STEP DN ISOLATION

PAT RM

STEP DN ISOLATION

PAT RM

STEP DN ISOLATION

PAT RM

STEP DN ISOLATION

PAT RM

STEP DN ISOLATION

PAT RM

ALCOVE

TELEMETRY

PAT RM

CLEAN

SUPPLY

CLEAN

LINEN

EQUIP

STORAGE

TEAM

RM

STAFF

LOUNGE

STAFF

LOCKER

ELECTRICAL

RM

TELEMETRY

OFFICE 1

CONFERENCE

RM

MEDICATION

RM

TELEMETRY

PAT RM

TELEMETRY

PAT RM

TELEMETRY

PAT RM

TELEMETRY

PAT RM

TELEMETRY

PAT RM

TELEMETRY

PAT RM TELEMETRY

PAT RM

TELEMETRY

PAT RM

FEC

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

R O

O F

DN UP

DNUP

UP DN

4-1B-1

4-1B-2

4-1A-1

4-1A-2

IP

IP

B U

IL

D

IN

G

B U

IL

D

IN

G

BUILDING 40

BUILDING 1

IP

IP

DAMEN AVENUE

O G

D

EN

AVEN

U E

T A

Y L O

R S

T R

E E

T

P O

L K

S T

R E

E T

1B

1A30

11A

11B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com

SITE PLAN

NORTH

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-1-4

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

BUILDING 1 - FOURTH FLOOR

TECHNOLOGY PLAN

GENERAL TECHNOLOGY NOTES :

1. ALL CAMERAS SHALL BE SERVED FROM IRM

CLOSET HC-1 UNLESS NOTED OTHERWISE.

REFER TO T-1-3 FOR HC-1 LOCATION.

2. REFER TO T-600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

3. REFER TO T-400 SERIES DRAWINGS FOR CCTV

RISER DIAGRAM.

4. REFER TO T-500 SERIES DRAWINGS FOR

INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE.

5. ALL EXISTING IP CAMERAS ARE TO BE

REPLACED. RE-USE EXISTING DATA OUTLET AND

CONFIGURE NETWORK AS REQUIRED TO

SUPPORT NEW CAMERA. REFER TO INDIVIDUAL

CAMERA REQUIREMENTS SCHEDULE ON T-500

SERIES DRAWINGS FOR ADDITIONAL

INFORMATION.

6. ALL EXISTING ANALOG CAMERAS ARE TO BE

REPLACED. DEMO EXISTING CABLE

INFRASTRUCTURE BACK TO SOURCE. PROVIDE

NEW CAT 6 CABLE. PROVIDE NEW OR EXTEND

EXISTING CONDUIT AS NECESSARY TO ROUTE

CAT 6 CABLE TO AREA SERVING IRM CLOSET.

REFER TO INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE ON T-500 SERIES DRAWINGS FOR

ADDITIONAL INFORMATION.

7. ALL CAMERAS AND ASSOCIATED EQUIPMENT TO

REMAIN OPERATIONAL UNTIL REPLACEMENT IN

LOCAL WORK AREA IS COMPLETE. PROVIDE

DRIVERS AND CODECS AS NEEDED.

N

O R HT

1/16" = 1'-0"1

BUILDING 1 - FOURTH FLOOR TECHNOLOGY PLAN

5629B

5447A

5496C

5496B

54E1

5434A

5430A

5472 5473

5400B

5400A

5429A

5425A

5423A

5424A

5439A

5433A

5496A

54E2

5489A

C5406

C5401C5402C5403C5404C5405

C5407

C5501

54415439

NO

540354025401

5400 5404

5406A

5435A 5436A

5426 5427

5444 5446

54715458A

5476 5475

5468 5469

5465 5482

5486 5488 5490 5492 5494

NO

54815479546354615460

P-1

P-2

P-3

P-4

S-5

S-6

55005501

NO

P-8

P-7

C5610

C5612

C5611

C5613

5630B

5632B

5634B

5636B

5638B

5619A

56E2

5618B

5620B

5622B

5624B

5626B

5612A 5618A

5620A 5622A

5624A 5626A

5627A

5628A

5629A

5642A 5638A

5636A 5634A

5632A 5630A

NO 13

5417A

54E3

5534 5532 5530 5528 5526

5533 5531 5529 5527 5525

5524A

5524B

5560A

5514 5515

5558 5540

5539 5541 5543 5545

5544B

5544B

5549A

5549C

5546A

5551A

5549B

5549D

5555A

NO 4

ALCOVE

STORAGESUPPLY CLOSET

FIRE CLOSET

TOILET

STORAGE

WOMENS

LOCKER

TOILET

ELECTRICAL

CLOSET

TOILET

TOILET

DRESSING RM

DRESSING

RM

DIRTY LINEN

CLEAN LINEN

TOILET

TOILET

TOILET

SOILED UTILITY

ICE

M/C

CLEAN LINEN

TOILET

TOILET

TOILET

LINEN

CHUTE

ELECTRICAL

PANEL

SUPPLY CLOSET

TELECOM

STORAGE

DUMBWAITER

RM

TELECOM

CLOSET

REGISTRATION DESK

TEL

RECEPTION AREA

CORRIDOR

CORRIDORCORRIDORCORRIDORCORRIDORCORRIDOR

CORRIDOR

CORRIDOR

MENS TOILET

STORAGEPROCEDURE RM

STORAGE

MEDICINE

PREP

STAIR

FILE RM

LOCKER

LOUNGE

TREATMENT BED-5TREATMENT BED-4TREATMENT BED-3

TREATMENT BED-2 TREATMENT BED-1

TOILET

WAITING SUPPLY

RM

EXAM RM

EXAM RM

DAY

SURGY

EXAM RM

PHARMACIST

OFFICE

TOILET TOILET

OFFICE

PSYCHOLOGIST

EXAM RM

EXAM RM

NURSE

STATION

BREAK

RM

EXAM RM

LINEN

HAC

PATIENT

EDUCATION

RM

CLEAN

SUPPLY

TOILET

WAITING AREA OFFICE

DOCTOR

LOUNGE

HAC

CLEAN LINEN

TOILETTOILET

MENS

LOCKER

NURSE

STATION

TOILET RECOVERY AREA

DRESSING TOILET

STORAGE TOILET

PROCEDURE

RM-5

PROCEDURE

RM-4

CLEAN RM CLEAN RM

PROCEDURE

RM-3

PROCEDURE

RM-2

SUPPLY

CLEANING RM

MECH RM

PROCEDURE

RM-1

STAIR

OFFICE

MED

ATTEND

NURSE

MGR

FELLOW

OFFICE

OFFICE ENDO

OFFICE

ENDO

DIRECTOR

STORAGE

ANEST

CHIEF

OFFICE

OFFICE

SURGICAL

OFFICES

ANESTHESIOLOGY

STAFF

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

OFFICEOFFICE

TEL

STAIR

SURGY

ADMIN

OFFICER

ELEVATOR

ELEVATOR

SECY

SURGICAL

CHIEF

SURGICAL

SVC

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

N MGR

ALCOVE

TOILET

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

VESTIBULE

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

LOCKER

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

STAIR

FIRE/ELECTRICAL CLOSET

ELEVATOR LOBBY

ELECTRICAL CLOSET

ELECTRICAL CLOSET

FIRE

CLOSET

STAIR

RECOVERY RECOVERY RECOVERY

TOLET

TOILET UNISEX LOCKERS

DRESS RM

DRESS RM

VIEWING

ALCOVE

LEAD VEST

STORAGE

CONTROL OBSERVATIONCATH EQUIP

TEE

STOR

SOILED

WORK TEE

STERILE STOR

CATH LAB

STAIR

EQUIP

EP

LAB

CORRIDOR

TEE

STORAGE

MEDS/

NOURISH

NURSE STATION

RECOVERY

TIL T

SUPPLY

STERILE

ECHO

PROCEDURE

ECHO READINGHOLTER

READING

ECHO

PROCEDURE

NURSE

OFFICE

OFFICE

FELLOW'S

SOILED

UTILITY

CLEAN

UTILITY

TECH.

OFFICE

JAN. CLOSET

OFFICE OFFICE

PROCEDURE

EKG LAB LAB STRESS

EQUIP.

ROOM

WORK

TOILET

UPS

EMS

JAN.

CLOSET

EKG LAB

STRESS ECHO

LAB

CONSULT ROOM

CHIEF

CARDIOLOGY

ECHO

LAB

EQUIP ROOM

SUB-WAITING

NURSE

MNGR.

PROGRAM CLERK

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

PRIVATE MS AND N

PAT RM

SEMI-PRIVATE MS

AND N PAT RM

NURSE

OFFICE 3

EQUIP

STORAGE

STAFF

LOUNGE

SOCIAL

WORK

OFFICE 1

SOCIAL

WORK

OFFICE 2

ELECTRICAL

RM

STRETCH

PARKCLEAN

LINEN

SEMI-PRIVATE MS

AND N PAT RM

SEMI-PRIVATE MS

AND N PAT RM

SEMI-PRIVATE MS

AND N PAT RM

SEMI-PRIVATE MS

AND N PAT RM

SEMI-PRIVATE MS

AND N PAT RM

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

SICU

LO

C

KER

PAR

K

EQ

U

IP

ROOF

5-1A-1

5-1A-2

IP

IP

B U

IL

D

IN

G

B U

IL

D

IN

G

BUILDING 40

BUILDING 1

DAMEN AVENUE

O G

D

EN

AVEN

U E

T A

Y L O

R S

T R

E E

T

P O

L K

S T

R E

E T

1B

1A30

11A

11B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

1100 Warrenville Rd, Suite 1100 Naperville, IL 60563

630.527.2320 Fax: 630.527.2321

www.kjww.com

1815 S. Meyers Road, Suite 200 Oakbrook Terrace, IL 60181

630.678.0808 Fax: 630.678.0858

www.CCSdifference.com

SITE PLAN

NORTH

FULLY SPRINKLERED

ISSUED FOR

SOLICITATION

02/15/17

EXP. 11/30/17

537-15-102

T-1-5

JABDLL02/15/17

820 S. DAMEN AVENUE

CHICAGO, IL 60612

JESSE BROWN VA MEDICAL CENTER:

VIDEO SECURITY CORRECTIONS

BUILDING 1 - FIFTH FLOOR

TECHNOLOGY PLAN

GENERAL TECHNOLOGY NOTES :

1. ALL CAMERAS SHALL BE SERVED FROM IRM

CLOSET HC-1 UNLESS NOTED OTHERWISE.

REFER TO T-1-3 FOR HC-1 LOCATION.

2. REFER TO T-600 FOR GENERAL TECHNOLOGY

EQUIPMENT SCHEDULE.

3. REFER TO T-400 SERIES DRAWINGS FOR CCTV

RISER DIAGRAM.

4. REFER TO T-500 SERIES DRAWINGS FOR

INDIVIDUAL CAMERA REQUIREMENTS

SCHEDULE.

5. ALL EXISTING IP CAMERAS ARE TO BE

REPLACED. RE-USE EXISTING DATA OUTLET AND

CONF…