This presolicitation notice is for an architectural and engineering (A/E) project to upgrade nursing unit isolation rooms and airflows at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The project requires modifying 31 patient rooms to maintain specific air pressure differentials, with 27 rooms designated as negative pressure and 4 rooms as positive pressure, eliminating the current dual-functionality design. The solicitation (36C25026R0050) is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC) with a response deadline of January 6, 2026, at 10:00 AM Eastern Time.

Key selection criteria include professional qualifications, specialized technical experience, project capacity, past performance, local knowledge, and commitment to using veteran-owned and small businesses as subcontractors. The A/E contractor will be responsible for inspecting room components, identifying deficiencies, designing solutions to meet VA regulations and industry standards, and providing support through bidding and construction phases. Interested firms must submit an electronic SF 330 package to the point of contact, Luke A. Turner, at luke.turner@va.gov, with the NAICS code 541330 and product service code C1DA applied to this procurement.

View the file

Other files

File Type Posted
36C25026R0050_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
AE Upgrade Nursing Unit Isolation Rooms & Airflows - 583-25-202

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
45219
SOLICITATION NUMBER*
36C25026R0050
RESPONSE DATE/TIME/ZONE
01-06-2026 10:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
C1DA
NAICS CODE*
541330
PLACE OF PERFORMANCE
Richard L. Roudebush VA Medical Center

1481 W. 10th Street

Indianapolis, IN 46202-2803

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Network Contracting Office (NCO) 10 260 E. University Avenue Cincinnati OH 45219

POINT OF CONTACT*

Luke A. Turner Contracting Officer luke.turner@va.gov 513-559-3712

DESCRIPTION

Description of Requirement:

The VAMC, Indianapolis has a requirement to maintain air pressure differentials between some designated patient rooms and the adjoining corridors or spaces. This pressure differential can be either positive, that is, the interior of the patient room has greater air pressure than does the adjoining corridor or space, or negative, that is, the interior of the patient room has a lower air pressure than does the adjoining corridor or space. Currently, some patient rooms are designed to be both positive and negative, selectable by a keyed interface. This dual functionality is no longer permitted under VA regulations so in accordance with the following table, each room shall be designated as either negative or positive; the keyed interface shall be disabled and removed, and the room operating sequence shall only function as indicated in the following table. Any equipment no longer required by this change shall be removed and discarded. At the conclusion of the project there shall be 27 negative pressure only rooms and four positive pressure only rooms. The terms “positive” and “negative” pressures shall be defined as follows: A single negative pressure symbol (-) shall mean a minimum negative pressure difference of 0.01” Water Column (WC); a double negative designation (--) shall mean a minimum negative pressure differential of 0.02 “ WC. A single positive pressure symbol (+) shall mean a minimum positive pressure differential of 0.01” WC. A double positive pressure symbol (++) shall mean a minimum positive pressure differential of 0.02” WC.

The A/E shall inspect and review all components of each room that can influence the pressure balance; identify all deficient components; determine how the rooms are operating in their current configuration; determine what changes are required to enable the rooms to operate in conformance with current VA requirements and industry standards under “normal” conditions, under “epidemic” conditions, and in compliance with all fire and smoke regulations and requirements. Compliance with all fire and smoke regulations shall include both “normal” and “epidemic” conditions. The use of the phrase “epidemic mode” is defined to mean an operating condition in which all negative pressure rooms maintain design pressure differences and air changes concurrently; AHUs meet the minimum outdoor air and filtration set points, and sequences accommodate extended door-open events. After the A/E presents a list of deficiencies and solutions to the VA; the A/E shall design, in conjunction with the VA, solutions for the identified components and system deficiencies. The A/E shall prepare plans and specifications to remediate all such deficiencies in components and systems and provide project assistance through the bidding and construction phases.

The hospital has 31 total pressure designated rooms with four rooms being designated as positive and the remaining 27 are designated as negative pressure rooms.

Selection Criteria:

(1) Professional qualifications necessary for satisfactory performance of required services.

(2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials.

(3) Capacity to accomplish the work in the required time.

(4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules.

(5) Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project.

(6) Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services.

(7) The extent to which potential contractors identify and commit to the use of service-disabled veteranowned small businesses, veteran-owned small businesses, and other types of small businesses as subcontractors.

SF 330 Submittal Instructions:

All interested and capable firms are to submit an electronic SF330 package for review. Physical copies will not be accepted. The SF330s can be submitted to the email address below:

luke.turner@va.gov The package must be received and in government control by the closing time/date of this announcement.

***END OF POSTING***

*=Required Field
Presolicitation Notice

Presolicitation Notice

File details come from the government source that posted it. Updated .