36C25023Q0917.docx

DOCX document 18 KB Posted

Attached to
6640--Histocore Biocut Rotary - Manual
Solicitation number
36C25023Q0917
Issued by

About this file

This is a combined synopsis/solicitation notice from the Department of Veterans Affairs seeking a Histocore Biocut Rotary or equivalent manual microtome. The notice requires white glove delivery of the Histocore Biocut Silver service including a one year service agreement, power cord, and disposable gloves to the Roudebush VA Medical Center in Indianapolis by July 21, 2023 at 4:00pm Eastern Time. Offerors must meet specifications for precision, thickness range, accuracy, stability, durability, and cutting blade. The award will be made to the responsible offeror whose offer is most advantageous based on technical quality, price, estimated delivery time, warranty, and past performance.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice

SUBJECT*
Histocore Biocut Rotary - Manual

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
48105
SOLICITATION NUMBER*
36C25023Q0917
RESPONSE DATE/TIME/ZONE
07-21-2023 4:00pm EASTERN TIME, NEW YORK, USA
ARCHIVE
5 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
6640
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Ann Arbor Healthcare System Network Contracting Office 10 2215 Fuller Road Ann Arbor MI 48105

POINT OF CONTACT*

Rachel MacRae 734-222-4326

PLACE OF PERFORMANCE

ADDRESS
Roudebush VA Medical Center

1481 W. 10th St

Indianapolis Indiana

POSTAL CODE
46202
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
Department of VA
AGENCY CONTACT’S EMAIL ADDRESS
rachel.macrae@va.gov
EMAIL DESCRIPTION
Email

DESCRIPTION

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation for quote to be requested with no other form of written solicitation to be issued.

This solicitation RFQ- 36C25023Q0917 is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-95/ 01-13-2017. The North American Industry Classification System (NAICS) number is 339112.

This is a solicitation only pertaining to a Histocore Biocut Rotary or equivalent. Note: this is a “Brand Name or Equal” item (s) solicitation. Vendor to supply necessary materials and/or parts for the requirements listed below. Materials and parts will be delivered to; Roudebush VA Medical Center, 1481 W. 10th St., Indianapolis, IN 46202, FOB destination.

Requirements:

Description
Minimum requirement

HistoCore Biocut Microtome

Biocut Silver service (1 year)

HI1210 000 127V 50 60HZ

Power Cord NEMA5 15

Low profile disposable

White Glove Delivery

Total

Note: Must include White Glove Delivery.

Type: Manual

· Precision, section thickness range should be between 0.25 to 100μm with increments in the range of 0.5μm, 1μm, 5μm

· Accuracy

· Stability

· Durability

· The machine should have a high-quality cutting blade

· An adjustable cutting speed

· A specimen holder that can securely hold the sample in place during cutting

Offerors must comply with all instructions contained in provision 52.212-1, Instructions to Offerors-Commercial, applies to this acquisition. Submit signed and dated offers to the office specified in this solicitation at or before the exact time specified in this solicitation. Offers may be submitted on the SF 1449, letterhead stationery, or as otherwise specified in the solicitation.

Contractor shall provide an authorized distribution letter. The Contractor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor, or authorized Contractor reseller for the proposed equipment/system such that the OEM warranty and service are provided and maintained by the OEM. All warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. The Contractor shall provide new items ONLY; no remanufactured/used or "gray market" items. All items must be covered by the manufacturer's warranty.

The following additional provisions apply:

52.211-6 Brand Name or Equal to item (s) 52.212-2, Evaluation-Commercial Items, the Government will award a contract/purchase order resulting from this solicitation to the responsible offeror whose offer conforms to the solicitation and is determined to be the most advantageous to the government; technical, price, estimated delivery time, warranty, and past performance considered.

52.212-3, Offeror Representations and Certifications-Commercial Items, a completed copy of this provision shall be submitted with the offer unless SAM registered which must be noted in the quote.

52.212-4, Inspection/Acceptance. The Contractor shall only tender for acceptance those items that conform to the requirements of this contract. The Government reserves the right to inspect or test any supplies or services that have been tendered for acceptance. The Government may require repair or replacement of nonconforming supplies or reperformance of nonconforming services at no increase in contract price.

52.212-5, Contract Terms and Conditions-Commercial Items. The following additional clauses apply: Purchase order (SF 1449) will be awarded to the winning bid with submission of Invoice through Tungsten upon delivery of ALL items listed on spreadsheet.

From the VAAR the following apply:

852.232-72 Electronic submission of payment requests. All invoices must be submitted to Tungsten for payment processing. The PO number must appear on all invoices, packing slips, shipping labels, and/or correspondences to the contracting officer.

852.246-71 Inspection of all parts will be held. If goods are rejected, they will be held for 15 days, if not replaced, the rejected merchandise will be returned to the contractor at their risk and expense. Payment of invoice will be delayed.

The PO number must appear on all invoices, packing slips, shipping labels, and/or correspondences to the contracting officer.

Contact: Rachel MacRae, Contracting Specialist, via email at rachel.macrae@va.gov. No telephone inquiries will be accepted. Only written inquires received directly for the offeror are acceptable. All quotes must be received by 7/21/2023 by 4:00pm EST to Rachel MacRae (rachel.macrae@va.gov).

*= Required Field
Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

File details come from the government source that posted it. Updated .