About this file

This document provides details regarding a federal contract opportunity for fall protection work at a Department of Veterans Affairs parking structure. The solicitation seeks a contractor to replace railing on three levels of the West Parking Structure at the VA Medical Center in Ann Arbor, Michigan. The selected contractor will remove existing railing, repair precast concrete, fabricate and install new fall deterrent fencing meeting VA standards and codes. The project includes preparation of phasing and shop drawings for review. The performance period is 150 days. The North American Industry Classification associated with this opportunity is 236220. The contract value is estimated between $1 million and $5 million. The agency intends to award a firm fixed price contract within 120 days of bid receipt.

View the file

Other files for this federal contract opportunity

Other files attached to Y1PZ--PARKING STRUCTURE FALL PROTECTION 506-20-105, newest first.
File Type Posted
Porject 506-20-105 RFI Answers.docx DOCX document
36C25020B0053 0004.docx DOCX document
36C25020B0053 0003.docx DOCX document
36C25020B0053 0002_1.docx DOCX document
36C25020B0053 0001.docx DOCX document
Wage Rates - MI2020100 Updated 7-10-2020.pdf PDF
506-20-105 Specifications - Revised 7-20-2020.pdf PDF
506-20-105 West Parking Structure Fall Protection Drawings - Revised 7-20-2020.pdf PDF
506-20-105 Specifications.pdf PDF
506-20-105 West Parking Structure Fall Protection Drawings.pdf PDF
Contractor EMR Certification Form 2020.docx DOCX document
36C25020B0053_1.docx DOCX document
506-20-105 RFI Form.docx DOCX document
MI20200100 01-24-2020.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

36C25018B0053 – Project 506-20-105 West Parking Structure Fall Protection Fall Protection - Ann Arbor VAMC

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 06-23-2020 506-20-105 Department of Veterans Affairs Network Contracting Office (NCO) 10 6150 Oak Tree Blvd., Suite 300 Independence

OH

44131 Department of Veterans Affairs Network Contracting Office (NCO) 10 6150 Oak Tree Blvd., Suite 300 Independence

OH

44131 To all Offerors/Bidders

36C25020B0053 06-24-2020

X x The purpose of this amendment is:

1. To provide RFI's answers abd BID opening call in conference number

End of amendment 0005

RICHMOND L MCCLOUD

Contracting Officer West Parking Structure Fall Protection Project # 506-20-105 SF-30 Continuation Page

1. The specifications call for 10-gauge plastic coated wire mesh, however this will not meet the fall safety requirements called out for in the plans. The only way to meet this is to increase the gauge of steel, which will mean a switch to galvanized.

Was it your intent to meet the fall safety requirements and have us put together our own specifications on this, or to ignore them and follow the specifications?

Answer: The plans do not specify the fall safety requirement.

Specification Section 05 70 00, Paragraph 2.1- Wire Metal Mesh, Subparagraph A.2. Specify “Material: Metal wire, 0.08” dia. Minimum” The contractor is to comply with the requirements in the specification for the mess.

BID Opening Call in instruction:

This conference is scheduled to begin on August 12 at 01:50 PM EST+ DST (New York).

This conference is scheduled to last for 80 minutes.

To access this conference via telephone, please call the following number: 8007671750, when prompted for your access code, please enter 50369 on your telephone keypad followed by the # key.

Please do not disclose this information to any unauthorized parties, as the privacy of your conference may be compromised.

We hope you enjoy your conference experience.

Page 1 of

Page 1 of

File details come from the government source that posted it. Updated .