Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

36C25019Q1151 0001 VA CARES 5th Fl As-Built Dementia Ward Security Enhancements Drawing.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Locking System, newest first.
File Type Posted
36C25019Q1151-0001002.docx DOCX document
36C25019Q1151-0001003.docx DOCX document
36C25019Q1151-0001005.pdf PDF
36C25019Q1151-0001001.docx DOCX document
36C25019Q1151-0001000.docx DOCX document
36C25019Q1151-000.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OWNER:

NTS

SCALE:

DRAWN BY:

SE-1

#VA250-15-R-0230

06/23/15

CARES TOWER 5th FLOOR

DEMENTIA WARD

SECURITY INTEGRATION

ZENITH SYSTEMS

SECURITY INTEGRATION

5068 Corbin Dr. Bedford Hts. Ohio 44128

Office (216) 395-5967 Fax (216) 518-8910

Contractors - Engineers - Designers Electrical - Data/Voice Networks - Fire Alarm

Temperature Control - Structured Cable - Building Automation - Energy Management Solutions

Audio/Visual - Security - Surveillance Communications

V.E.S 06/23/151 CREATED

L O

U

IS

S T

O K

E S

M E

D

IC

A L

C E

N T

E R

C A

R E

S T

O W

E R

, C L

E V

E L

A N

D , O

H

IO

U.S. VETERANS AFFAIRS

LOUIS STOKES MEDICAL CENTER

10701 EAST BOULEVARD, CLEVELAND,

OHIO 44106

SECURITY ENHANCEMENTS

DATE:

SOLICITATION

DATE:

15.50119

JOB#:

PROJECT NOTES

#1 Upgrade Current Magnetic Lock to a 1,500Lbs Delayed Egress Model with Door Position.

#2 Install/Upgrade Proximity Reader to a FIPS-201 Keypad Model

#3 Install a New 1.3MP Network Camera to view door from the un-secured side of door opening.

#4 Integrate the Lenel OnGuard Security System to the RTLS Patient Elopement System

#5 Remove Decommissioned Wonder Guard Patient Elopement System from Wall.

V.E.S 11/23/15AS-BUILT

#1 #2 #3 #4 #5

#1 #2 #3 #4 #5

#1

#3 #4 #5

#1 #2 #3 #4 #5

#2 #4

#2 #4

#2 #4

H /S

1.3MP

MAG

10.83.26.215

1.3MP

M

AG

M

AGCR

CR

10.83.26.218

ELOP

1.3MP

MAG

10.83.26.216

CRELOP

1.3MP

MAG 10.83.26.217

CR

ELOP

CR

ELOP

CR

ELOP

CR

ELOP

#2

H /S

H/S

Outdoor Axis 1.3MP Camera, 2.5mm to 6mm P‐Iris Lens 4

1.3MP

MAG

H/S

DRAWING LEGEND

System Sensor Emergency Horn/Strobe for (3) Stairwells

Allegion 1,500 Lb Delayed Egress Magnetic Lock

CR FIPS‐201 Multi‐Class Proximity/Keypad Reader 7

ELOP Patient Elopement Receiver/Interface 7

18/4 Stranded No‐Shld Plenum Cable

Category ‐6 Plenum Cable

Access Control Composite Plenum Cable

CABLE LEGEND

H/S

Door

MAG

DC

ELOP

BYPASS

INPUT NO

LNL‐1100

C NO C NO

AUX

OUT 1

AUX

OUT 2

IN

CO

M

INPUT

LNL‐1200

C NO

AUX

OUT 1

ELOP

BYPASS

INPUT NO

Passenger Elevator

Lenel Door Input/Output Schematic (Card Reader Not Shown)

Lenel Elevator Output Schematic (Card Reader Not Shown)

ELO

P

Lenel On-Guard Head-End Location