36C25019Q0913-000.docx
DOCX document 19 KB Posted
- Attached to
- eVideon Capable Televisions Federal contract opportunity
- Solicitation number
- 36C25019Q0913
About this file
36C25019Q0913 36C25019Q0913.docx
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Sources Sought Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Sources Sought Notice Rev. March 2010 eVideon Capable Televisions 48105 36C25019Q0913 06-13-2019 N 334220 Department of Veterans Affairs Ann Arbor Healthcare System Network Contracting Office 10 2215 Fuller Road Ann Arbor MI 48105 Jeremy Boston Jeremy.Boston@va.gov Telephonic Inquiries not accepted.
Ann Arbor VA Medical Center 2215 Fuller Road Ann Arbor, MI 48105 This is a Sources Sought Notice for televisions as identified in the Statement of Work and Equipment Information for the Ann Arbor VA Medical Center and the Green Road outpatient clinic. The contractor shall furnish all necessary labor, supervision, management, management support, transportation, supplies, equipment, and materials necessary to furnish the following services. The equipment to be services is provided and is subject to changes. A draft Statement of Work is attached to this notice and is subject to change should a solicitation be issued as a result of this notice.
PERSONNEL QUALIFICATIONS AND REQUIREMENTS:
Please respond if you have the ability and intent to complete this requirement. Include in your response the following information:
· Capabilities Statement;
· Company Name and Address;
· DUNS Number;
· Socioeconomic Size Status (e.g. Large, Small, WOSB, SDVOSB, etc.)
· Point of Contact information (name, phone, email);
· Whether site visit will be required/requested;
· FSS or GSA Contract Number, if applicable.
This Sources Sought Notice is intended to locate any business capable of performance.
The anticipated NAICS Code for this requirement is 334220.
This is not a Request for Quotation and quotes shall not be reviewed at this time.
The Department of Veterans Affairs shall not be responsible for any costs incurred by the contractor as a result of this Sources Sought Notice.
This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.
All responses shall be submitted via email by Wednesday, July 10, 2019 at 10:00 AM EST. Responses shall be submitted to Jeremy Boston at Jeremy.Boston@va.gov. Phone calls shall not be accepted for this notice.
*Scope/Statement of Work and Equipment Information ae currently drafts and subject to change.
SCOPE OF WORK FOR INTERACTIVE PATIENT TV EXPANSION
Background The top priority of the VA Ann Arbor Medical Center is to ensure quality care and comfort for our patients. An expansion of our current digital signage, TV displays, and patient cable and movie options would allow us to provide a more comfortable experience for our patients. The intent of this scope of work is to improve the TV’s and media options in three patient room locations as well as digital signage and TV’s in various locations throughout the medical center. The intent of this work shall be for the awardee to use the government furnished property, provide additional equipment, complete programming, and integration resulting in a complete upgrade that functions to the VA’s specifications as detailed in the scope. The intent of this scope is to provide a better experience for patients while in patient and waiting rooms, to give our staff the ability to use these new upgrades for patient education, and to provide more digital signage throughout the medical center to aid in wayfinding and public relations.
Scope Contractor shall uninstall and separate parts to be retained/reused (as GFE) from parts handed back for disposal/recycling by the VA. Supply all parts and labor required to install. Commission and test the new TV displays after installation. Provide all final documentation deliverables including original operator manuals, source code and “as-built” CAD drawings for the completed system.
6 South - 2215 Fuller Road, Ann Arbor, MI 48105 In the 30 patient rooms, the contractor shall provide 30 Hospital Grade 43” 4K Smart TV, Web OS 3.5 or 4.0 (43UV770M) or equal based on the salient characteristics below and provide 35 (one for each room plus 5 spares) Pillow Speakers. In the Patient waiting room, provide 1 Commercial Grade 55” 4K Smart TV, Web OS 3.5 or 4.0 (55UU770H) or equal based on the salient characteristics below, with Tilt Mount. The patient rooms currently have mounts installed, so new mounts are not needed. All cabling is currently in place in all these locations but two. Running the coax cable to these two locations will not be the responsibility of the contractor.
Digital Signage throughout Ann Arbor VA Medical Center – 2215 Fuller Road, Ann Arbor, MI 48105 The contractor shall provide the following commercial grade 4K Smart TVs, Web OS 4.0 commercial grade TV’s with tilt mounts as follows. TV’s shall be of the same manufacturer as the 30 Hospital Grade TVs listed above:
| Smart TV |
| QTY |
| Tilt Mount QTY |
| 32" |
| 10 |
| 9 |
| 49" |
| 21 |
| 18 |
| 55" |
| 3 |
| 2 |
| 65" |
| 15 |
| 14 |
| 75” |
| 1 |
| 0 |
| Total |
| 50 |
| 44 |
The contractor shall provide 12 hours of design work shall be supplied by the contractor. Running coax cable to these locations will not be the responsibility of the contractor.
Interventional Radiology - 2215 Fuller Road, Ann Arbor, MI 48105 The contractor shall provide and install 12, 19” Smart Touch Screen IPTV with Ceiling Mounts. Data cabling to nearest telecom closet (approx. 150’) and power over coax will need to be supplied by the contractor. Installation shall occur when the Radiology department is closed (typically evenings and weekends). In the patient waiting room, the contractor shall provide 1 Commercial Grade 55” 4K Smart TV, Web OS 3.5 or 4.0 (55UU770H) or equal based on the salient characteristics below, with Tilt/Swivel Mount. Data cabling to nearest telecom closet (approx. 150’) in this location will be the responsibility of the contractor.
Additional Requirements The contractor shall notify the COR immediately if any government furnished equipment is found to be not functional or incompatible. The government will either provide replacement equipment, negotiate a modification to the contract to require the contractor to provide replacement equipment, or provide direction to resolve the issue.
Following the initial meeting and in accordance with the delivery schedule and normal manufacturer lead times, required parts will be ordered. Unless otherwise stated, parts are shipped to a contractor-owned, climate-controlled commercial property for off-site storage, integration, and staging. Once project is started, VA will provide locked storage in a climate-controlled area, this area will be large enough for anything that the contractor will need to store during this project. The storage area will be located in the same building as the project locations.
Any and all parts/supplies provided by contractor shall be new, sourced from the manufacturer or authorized channel/reseller/distributor, and convey to the government with original manufacturer warranty rights, accessories, and manuals. Contractor will re-use parts as designated/directed by the VA and reinstall and integrate GFP with the newly supplied commercial items to be supplied by Contractor to form a complete, functional system. Contractor will uninstall prior equipment, cabling etc. that will not get reused and remove from premises for recycling/disposal.
Installing company shall be able to respond within one hour and be on site to troubleshoot within four hours during the one-year warranty period. The project will need a project manager identified, a project engineer and a lead installer identified. A proposed installation schedule along with installing company address, and at least two jobs that are similar in size and scope with reference phone numbers shall be submitted with proposals.
EQUIPMENT INFORMATION
| Item Number |
| Description |
| MODEL NUMBER |
| Quantity |
| Unit of Measure |
| SALIENT CHARACTERISTICS |
| 0001 |
| QAM/IP 48 CHANNEL (GREEN RD UPGRADE) |
| APL-UCYPT48PRO |
| 1 |
| EA |
| 0002 |
| EVIDEON PILLOW SPEAKER-LG TV & RAULAND NURSE CALL |
| IPS-EV-RLD |
| 35 |
| EA |
| Brand Name Only |
| 0003 |
| LG 32" SMART TV-COMMERCIAL |
| 32LV760M |
| 10 |
| EA |
| - Smart TV with WebOS 3.5 or higher |
- Compatible with eVideon application/software
- minimum of (2) HDMI inputs, (1) COAX Input, (1) LAN Input
| 0004 |
| LG 43" SMART TV-HOSPITAL GRADE WITH PS PORT |
| 43UV77OM |
| 31 |
| EA |
| - Smart TV with WebOS 3.5 or higher |
- Compatible with eVideon application/software
- minimum of (2) HDMI inputs, (1) COAX Input, (1) LAN Input
- Pillow Speaker Compatibility
| 0005 |
| LG 49" SMART TV COMMERCIAL |
| 49UU770H |
| 21 |
| EA |
| - Smart TV with WebOS 3.5 or higher |
- Compatible with eVideon application/software
- minimum of (2) HDMI inputs, (1) COAX Input, (1) LAN Input
| 0006 |
| LG 55" SMART TV COMMERCIAL |
| 55UU770H |
| 3 |
| EA |
| - Smart TV with WebOS 3.5 or higher |
- Compatible with eVideon application/software
- minimum of (2) HDMI inputs, (1) COAX Input, (1) LAN Input
| 0007 |
| LG 65" SMART TV COMMERCIAL |
| 65UU770H |
| 15 |
| EA |
| - Smart TV with WebOS 3.5 or higher |
- Compatible with eVideon application/software
- minimum of (2) HDMI inputs, (1) COAX Input, (1) LAN Input
| 0008 |
| LG 75" SMART TV COMMERCIAL |
| 75UU770H |
| 1 |
| EA |
| - Smart TV with WebOS 3.5 or higher |
- Compatible with eVideon application/software
- minimum of (2) HDMI inputs, (1) COAX Input, (1) LAN Input
| 0009 |
| TV MOUNT |
| 42 |
| EA |
| See details in SOW. |
| 0010 |
| PDI 19" SWING ARM TOUCH SCREEN TV |
| PDI-P19A-BB2H-C |
| 12 |
| EA |
| 0011 |
| COAX CABLE & POWER OVER COAX HARDWARE |
| 1 |
| EA |
| See details in SOW. |
| 0012 |
| LABOR/INSTALL OF PDI SWING ARM TVS |
| 1 |
| EA |
| See details in SOW. |
File details come from the government source that posted it.