36C25019B0050-028.pdf
PDF 7 MB Posted
- Attached to
- Upgrade Fire Radio System 539-17-201 Federal contract opportunity
- Solicitation number
- 36C25019B0050
About this file
This notice announces an upcoming Invitation for Bid for an Upgrade Fire Radio System project at the Veterans Affairs Cincinnati VAMC. The solicitation will be issued as a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Offerors must be small under NAICS code 236220, with a business size standard of $36.5 million. The project scope involves upgrading the fire radio system across an 11-story building. The contract value is estimated between $500,000 to $1,000,000. The performance period is 185 calendar days from notice to proceed. Bonds will be required in the form of bid, payment, and performance bonds. Interested SDVOSBs should register on SAM.gov and Vendor Information Pages and ensure their registrations are accurate and active through award. Safety and environmental violations as well as experience modification rates must be provided prior to construction award.
36C25019B0050 Attach 3 Drawings 02.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25019B0050-0003000.docx | DOCX document | |
| 36C25019B0050-0003000.docx | DOCX document | |
| 36C25019B0050-0002002.pdf | ||
| 36C25019B0050-0002000.docx | DOCX document | |
| 36C25019B0050-0002001.pdf | ||
| 36C25019B0050-0002002.pdf | ||
| 36C25019B0050-0002001.pdf | ||
| 36C25019B0050-0002000.docx | DOCX document | |
| 36C25019B0050-0001000.docx | DOCX document | |
| 36C25019B0050-0001000.docx | DOCX document | |
| 36C25019B0050-025.docx | DOCX document | |
| 36C25019B0050-028.pdf | ||
| 36C25019B0050-026.docx | DOCX document | |
| 36C25019B0050-027.pdf | ||
| 36C25019B0050-030.docx | DOCX document | |
| 36C25019B0050-029.docx | DOCX document | |
| 36C25019B0050-029.docx | DOCX document | |
| 36C25019B0050-026.docx | DOCX document | |
| 36C25019B0050-025.docx | DOCX document | |
| 36C25019B0050-027.pdf | ||
| 36C25019B0050-030.docx | DOCX document | |
| 36C25019B0050-000.docx | DOCX document | |
| 36C25019B0050-000.docx | DOCX document |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
Department of Veterans Affairs Medical Center
LEVIN PORTER ASSOCIATES
ARCHITECTURE PLANNING INTERIOR DESIGN
3011 NEWMARK DRIVE
MIAMISBURG, OH 45342
937.224.1931 P
937.224.3091 F
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
HEAPY ENGINEERING
MECHANICAL ELECTRICAL COMMISSIONING TECHNOLOGY
1400 WEST DOROTHY LANE
DAYTON, OH 45409
937.224.0861 P
937.224.5777 F
52109.00
3/
/2
2:
:2
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
COVER SHEET
G001
WSVP/BW
539-17-201
Cincinnati, Ohio
UPGRADE FIRE RADIO SYSTEM
3200 VINE STREET CINCINNATI, OHIO
SHEET
NO. SHEET NAME
GENERAL
G001 COVER SHEET
G002 STANDARDS INDEX
G003 CODE REVIEW
ARCHITECTURAL
A101 SIGNALS CLOSET DEMOLITION PLANS
A102 TENTH-ELEVENTH FLOOR PENTHOUSE DEMOLITION PLANS
A103 SIGNALS CLOSET NEW WORK PLANS
A104 TENTH-ELEVENTH FLOOR PENTHOUSE NEW WORK PLANS
TECHNOLOGY
ET-001 LEGENDS, SYMBOLS &INDEX OF DRAWINGS
ET-099 PIPE BASEMENT PLAN
ET-100 BASEMENT PLAN
ET-101 FIRST FLOOR PLAN
ET-102 SECOND FLOOR PLAN
ET-103 THIRD FLOOR PLAN
ET-104 FOURTH FLOOR PLAN
ET-105 FIFTH FLOOR PLAN
ET-106 SIXTH FLOOR PLAN
ET-107 SEVENTH FLOOR PLAN
ET-108 EIGHTH FLOOR PLAN
ET-109 NINTH FLOOR PLAN
ET-110 TENTH - ELEVENTH FLOOR PLAN
ET-501 DETAILS
VICINITY MAP
NORTH
GENERAL PROJECT NOTES
SHEET INDEX
A. COORDINATE FINAL PLACEMENT OF ALL WALL MOUNTED EQUIPMENT WITH SIGNAGE.
B. ALL WORK WILL COMPLY WITH ALL APPLICABLE NATIONAL, STATE OR LOCAL CODES, ORDINANCES AND REGULATIONS INCLUDING THE AMERICAN
DISABILITIES ACT (ADA) AND THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) GUIDELINES.
C. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE COR OF ANY WORK THAT MIGHT REQUIRE INTERRUPTION OF UTILITY SERVICES, CAUSE
NOISE, OR CREATE VIBRATION PRIOR TO COMMENCEMENT OF THIS WORK.
D. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF THE SPECIFICATIONS INCLUDING ALL GENERAL CONDITIONS, SUPPLEMENTARY
GENERAL CONDITIONS, MATERIAL AND CONSTRUCTION PROVISIONS WHICH APPLY TO MATERIALS OR CONSTRUCTION METHODS REQUIRED.
E. DO NOT PAINT ANY SEALANTS OR CAULKING WHICH ARE SUBJECT TO MOVEMENT. CONTROL JOINTS SHALL BE CAULKED AFTER PAINTING AND SPECIAL
COATING APPLICATIONS. PROVIDE CAULKING OR SEALANTS WHICH MATCH ADJACENT FINISHED COLORS UNLESS NOTED OTHERWISE.
F. ALL EXISTING CONSTRUCTION TO REMAIN THAT ARE DAMAGED OR DISTURBED DURING CONSTRUCTION SHALL BE PATCHED OR REPAIRED TO MATCH
EXISTING ADJACENT CONSTRUCTION.
G. ALL INTERIOR WOOD BLOCKING, MISC. FRAMING, PANELS, ETC. THAT ARE TO BE USED SHALL BE FIRE-RETARDANT TREATED. ALL EXTERIOR WOOD
BLOCKING SHALL BE PRESSURE TREATED.
H. ALL SUSPENDED ITEMS SHALL BE ATTACHED DIRECTLY TO STRUCTURE AND NOT ANCHORED TO ANY NON-STRUCTURAL ITEM, COMPONENT OR SYSTEM.
I. ALL NEW PENETRATIONS IN ALL EXISTING, MODIFIED OR NEW CORRIDOR WALLS, SMOKE AND FIRE PARTITIONS, AND FLOOR SLABS SHALL BE SEALED WITH
FIRE RESISTANT CAULKING OR SEALANT THAT PREVENTS THE PASSAGE OF SMOKE AND/OR FIRE ALL COMPLYING TO THE LIFE SAFETY AND FIRE CODE AND
MEETING EXISTING CONDITIONS.
J. NEW CORE DRILLING THROUGH EXISTING STRUCTURAL ELEMENTS REQUIRED BY CONSTRUCTION SHALL BE COORDINATED BY THE CONTRACTOR TO AVOID
DRILLING THROUGH OR INTO ANY STRUCTURAL ELEMENTS.
K. NEW CONSTRUCTION INSTALLED SHALL BE COORDINATED BY THE CONTRACTOR FOR PROPER FIT, DIMENSIONS AND ACCESS TO THE BUILDING PRIOR TO
BEGINNING CONSTRUCTION AND DELIVERY OF COMPONENTS TO THE SITE.
L. INTERIOR DIMENSIONS ARE TO FINISH FACE UNLESS NOTED OTHERWISE
M. INTERIOR CONCRETE SLABS AND PATCHES, USE MIN. 10 MIL REINFORCED POLYETHYLENE VAPOR BARRIER UNDER CONCRETE SLAB. TROWEL SURFACE
SMOOTH AND FINISH FLUSH WITH EXISTING SLAB ELEVATION. SEAL VAPOR BARRIER WATERTIGHT.
N. CONTRACTOR'S BID SHALL INCLUDE THE GREATEST QUANTITY AND QUALITY OF ALL ITEMS AND ASSEMBLIES FOR A COMPLETE AND FULLY OPERATIONAL
PROJECT IN ACCORDANCE WITH THE VETERAN ADMINISTRATION'S REQUIREMENTS
O. UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS, CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION, REMOVAL AND REPLACEMENT
WORK SPECIFIED AND REQUIRED TO ACCOMMODATE THE REQUIRED IMPROVEMENTS, AND SHALL ALSO BE RESPONSIBLE FOR ANY AND ALL NECESSARY REPLACEMENT, REPAIRING, AND PATCHING. WORK TO BE DONE BY WORKMAN SKILLED AND REGULARLY EMPLOYED IN THE TRADES INVOLVED.
P. CONTRACTOR SHALL PROPERLY PLAN AND EXECUTE ALL WORK. NO EXTRA COSTS FOR LACK OF PROPER PLANNING AND EXECUTION SHALL BE
CONSIDERED.
Q. CONTRACTOR SHALL VERIFY AS-BUILT CONDITIONS FOR MATERIAL DIFFERENCES PRIOR TO PERFORMING ANY WORK AND SHALL NOTIFY THE COR OF ANY
DISCREPANCIES.
Revision s
Date
100% BID DOCUMENTS 03/13/2019
KEY PLAN
& AND
∠ ANGLE
@ AT
℄ CENTERLINE
DIAMETER OR ROUND
Ÿ SQUARE
# POUND OR NUMBER
A# AIR WITH NUMBER OF
VALVES INDICATED
A/C AIR CONDITIONING
ABI ADDITIONAL BID ITEM
ACOUS ACOUSTICAL
ACC ACCESSIBLE
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADD'L ADDITIONAL
AED AUTOMATED EXTERNAL
DEFIBRILLATOR
ADJ. ADJUSTABLE or ADJACENT
A.F.F. ABOVE FINISHED FLOOR
AGGR AGGREGATE
AL or ALUM ALUMINUM
ALT ALTERNATE
ANOD ANODIZED
APROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASB ASBESTOS
ASC ACID STORAGE CABINET
ASPH ASPHALT
AUTO AUTOMATIC----------------------------------------
BBD BULLETIN BOARD
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLK'G BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
BRZ BRONZE
BSMT BASEMENT
BSC BIOSAFETY CABINET----------------------------------------
C. COURSES
CAB CABINET
C.B. CATCH BASIN or CHALKBOARD
CEM CEMENT
CER CERAMIC
CG CORNER GUARD
CHAM CHAMFER
CHK. BD. CHALK BOARD
C.I. CAST IRON
C.J. CONTROL JOINT
C.L. CENTER LINE
CLG CEILING
CLKG CAULKING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
COMPT COMPARTMENT
CONC CONCRETE
CONF CONFERENCE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP CLOSURE PANEL OR FINISHED PANEL
CS CUPSINK, SEE SPECIFICATIONS FOR SIZE
CSMT CASEMENT
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSUNK
CW COLD WATER
D DATA
D.A. DOOR ACTUATOR
DBL DOUBLE
DEPT DEPARTMENT
DEPART DEPARTURE
DET DETAIL
DF DRINKING FOUNTAIN
DI DIONIZED WATER
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
DN DOWN
D.O. DOOR OPENING
DR DRYING RACK or DOOR
DS DOWN SPOUT
DSP DRY STANDPIPE
DW DUMBWAITER
DWR DRAWER
DWG DRAWING (S)
E EAST OR ELECTRIC OUTLET, COORDINATE
WITH ELECTRICAL CONTRACTOR
EA EACH
E.C.C. ENVIRONMENTAL CONTROL CHAMBER
EJ EXPANSION JOINT
EL or ELEV ELEVATION or ELEVATOR
ELEC ELECTRICAL
EMER EMERGENCY
ENCL ENCLOSURE
ENLRG'D ENLARGED
EP ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
ES EMERGENCY SHOWER STATION BY PLUMBING CONTRACTOR
EW EMERGENCY EYEWASH BY PLUMBING CONTRACTOR
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EX or EXIST EXISTING
EXPO EXPOSED
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAK FIRST AID KIT
FB FIRE BLANKET or FLAT BAR
FBD FIREBOARD
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FGL FIBERGLASS
FH FUME HOOD
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FHS FIRE HOSE STATION
FIN FINISH
FL or FLR FLOOR
FLASH FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY (CMU)
FOS FACE OF STUDS
FP FIREPOOF
FR(T) FIRE RETARDANT (TREATED)
FS FILLER STRIP or FULL SIZE
FSC FLAMMABLE STORAGE CABINET
FT FOOT OR FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
FV FIELD VERIFY
G# GAS COCK WITH NUMBER OF VALVES INDICATED
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GL GLASS or GRID LINE
GND GROUND
GR GUARD RAIL or GROUND
GT GROUT
GYP GYPSUM
HB HOSE BIBB
HBD HARDBOARD
HC HOLLOW CORE
HD HEAVY DUTY
HDR HEADER
HDWD HARDWOOD
HDWE HARDWARE
HEX HEXAGON
HGT HEIGHT
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR
HTG HEATING
HVAC HEATING / VENTILATION / AIR CONDITIONING
HW HOT WATER
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER (DIM)
INSUL INSULATION
INT INTERIOR
ISO ISOMETRIC
JAN JANITOR
JC JANITOR'S CLOSET
JT JOINT
KIT KITCHEN
KPL KICKPLATE
KS KNEE SPACE
L LEFT
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LH LEFT HAND
LKR LOCKER
LOC LOCATION
LLD LEAD LINED DOOR
LT LIGHT
LTD LIMITED
LTL LINTEL
LVL LEVEL
LVR LOUVER
M METER
MACHINE
MAINT MAINTENANCE
MACH MACHINE
MAS MASONRY
MAX MAXIMUM
MM MILLIMETER
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLD MOLDING
MO MASONRY OPENING
MOD MODIULAR or MODIFY (IED)
MOV MOVABLE
MT MOUNT
MTL or MET METAL
MTD MOUNTED
MUL MULLION
MWK MILLWORK
N NORTH
NAT NATURAL
NI NICKEL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NON COM NON-COMBUSTABLE
NTS NOT TO SCALE
O/ OVER
OA OVERALL
OC ON CENTER
OD OUSIDE DIAMETER (DIA)
OFF OFFICE
OH OVERHEAD
OPH OPPOSITE HAND
OPN'S OPENING
OPP OPOSITE
OPS OPPOSITE SURFACE
PRCST PRE CAST
PB PANIC BAR
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE (D)
PERI PERIMETER
PG PLATE GLASS
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PNL PANEL
PORT PORTABLE
PPG POLISHED PLATE GLASS
PR PAIR
PS PULL SCREEN
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT or PRESSURE TREATED
PTD/PTR PAPER TOWEL
DISPENSER/RECEPTICAL
PTN PARTITION
R RIGHT
RA RETURN AIR
RAD RADIUS
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RECEP RECEPTACLE
RECEPT RECEPTIONIST
REF REFERENCE
REFL REFLECTED
REFR or REFRIG REFRIGERATOR
REV REVISION
REINF REINFORCED
REQ ('D) REQUIRE (MENT) (S) ('D)
RESIL RESILIENT
RFS ROOM FINISH SCHEDULE
RGTR REGISTER
RH RIGHT HAND
RM ROOM
R.O. ROUGH OPENING
RS REAGENT SHELF or ROUGH SAWN
RWC RAIN WATER CONDUCTOR
RWL RAIN WATER LEADER
S SOUTH
SB SMOKE BARRIER or SINK BASE
SC SOLID CORE
SCHED SCHEDULE
SD STORM DRAIN or SOAP DISPENSER
SECT SETION
SFRM SPRAY APPLIED FIRE
REISTIVE MATERIAL
SF GL SAFETY GLASS
SG SHEET GLASS
SH SHELF
SHR SHOWER
SHT SHEET
SIM SIMILAR
SKL SKYLIGHT
SL SLOPE
SND or SNR SANITARY NAPKIN
DISPENSER/RECEPTICAL
SP SOUND PROOF
SPEC SPECIFICATION
SPK SPEAKER
SPL SPECIAL
SQ SQUARE
SS STAINLESS STEEL
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
STRL STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
SYN SYNTHETIC
SYS SYSTEM
TB TACK BOARD
TEL TELEPHONE
T&G TONGUE & GROOVE
THK THICK
TJ TOOLED JOINT
TO TOP OF
TV TELEVISION
TYP TYPICAL
UNF UNFINISHED
UON or UNO UNLESS
OTHERWISE NOTED
UR URNAL
V# VACUUM WITH NUMBER
OF VALVES INDICATED
VAR VARNISH
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VF VINYL FABRIC
VIF VERIFY IN FIELD
VNR VENEER
VT VINYL TILE
VWC VINYL WALL COVERING
W WEST
W/ WITH
WB WOOD BASE
WC WALL CABINET
WD WOOD
WG WIRED GLASS
WM WIRE MESH
W/O WITHOUT
WP WATER PROOF
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
XMFRTRANSFORMER
1.
MACH
(E) EXISTING
(N) NEW
CFMF COLD FORM METAL FRAMING
WRB WEATHER RESISTANT BARRIER
SURFACE MOUNTED
4' LIGHTING FIXTURE
2' x 4' RECESSED
LIGHTING
FIXTURE
RECESSED LIGHTING
FIXTURE (CENTER IN
CEILING
GRID SPACE)
DIR. LIGHTING FIXTURE
(CENTER IN CEILING
GRID
SPACE)
SUPPLY GRILLE
RETURN GRILLE
2' x 4' ACOUSTICAL CEILING
2' x 2' ACOUSTICAL CEILING
GYPSUM BOARD CEILING
EXPOSED STRUCTURE
FULL HEIGHT WALL
STRUCTURAL WOOD
FINISHED WOOD
PLYWOOD
STEEL OR METAL
CERAMIC TILE
CEMENT, STUCCO,
PLASTER, OR
STONE
RIGID INSULATION
BATT, BLANKET, OR
LOOSE
FILL INSULATION
SPRAY-
APPLIED
INSULATION
GRANULAR/GRAVEL FILL
FACE BRICK
ACOUSTICAL TILE
CARPET
METAL (GREATER
THAN
1" = 1'-0" SCALE)
METAL (LESS THAN
1"
= 1'-0" SCALE)
GLASS BLOCK
CONCRETE
MASONRY
UNIT (CMU)
EARTH
CONCRETE (SECTION)
CMU / BRICK
VENEER
STUD
PARTITION
CMU
STUD/ BRICK
VENEER
EXISTING
PARTITION
4"
1'-6"CLEAR
(MINIMUM)
1'-0" CLEAR
WITH
CLOSER AND
LATCH
6" M
A X
E Q
E
Q
D
IM
D
DOOR LOCATION DETAIL
DOOR FRAMING DETAIL
REF. USG GYPSUM
CONSTRUCTION
HANDBOOK
SCALE: N.T.S.
N.T.S.
20 GA. (MIN) DOUBLE
STUDS @ EACH
JAMB
METAL DOOR FRAME
CONTINUOUS BRACING
WHERE STUDS ARE
MORE THAN 12'-0" LONG
RUNNER
BETWEEN
JAMB STUDS
METAL STUDS @
16" O.C. MAX
3/4" HORIZ. BRACING WHEN
OPENING IS MORE THAN
3'-0"-OMIT BRACING WHEN DIM.
"D" IS 2'-0" OR LESS
STRUCTURAL
FLOOR /
ROOFRUNNER
JAMB ANCHOR - MIN. 4
ANCHORS PER JAMB-TYP.
RUNNER
FLOOR SLAB
WOMEN
2' -9
T
O
'-0
1' -5
T
O
'-7
(A D
A
3' -4
M
A X
2'-6"
3' -4
M
A X
8" MIN.
KNEE
CLR.
6" MAX.
TOE
CLR.
1' -5
M
A X
(A
D A
4' -0
M
A X
4' -0
M
A X
T
O D
IS
C
O N
N E
C
S
R
A P
3' -0
M
A X
(A
D A
9" M
IN
2' -3
M
IN
2' -5
M
A X
2' -3
M
IN
8" MIN. 6" MAX.
1'-5" TO 2'-0"
B O
T T
O M
O F
M
IR
R O
R S
U R
F A
C E
9" M
IN
. T
O E
C
LR
2' -1
0" M
A X
A
D A
K N
E E
C
LR
3' -4
M
A X
2' -6
M
A X
2' -8
M
A X
2' -9
T
O
'-0
9" MAX.
4'-6"
3'-6"12" MAX
1' -0
2'-0"
1'-6"
3'-0"
3' -6
M
A X
2'-6" MIN.
CLR. - TYP.
1' -0
T
Y P .
3' -6
T
Y P
2' -0
3' -0
(A
D A
2'-6" MIN.
(N O
N
A D
A
3" 1'-1"
MIN.
4"
6' -0
M
A X
1' -6
3'-4"
1'-7"
5' -0
SEAT
COVER
DISPENSER
S.N.R.
WATER CLOSET
CLEAR FLOOR
LAVATORYURINALS
SPACE - TYP.
MIRROR - SEE PLAN DISPENSER
DISPENSER
OPENING
DISPOSAL
OPENING
TOWEL DISP.
SOAP
DISP.
SAN.
NAP.
DISP.
SAN.
NAP.
REC
FIRE
EXT.
DRINKING FOUNTAINS
TISSUE
DISPENSER
GRAB
BAR
FULL
HEIGHT
MIRROR
DISPENSER
OPENING
SEAT
COVER
DISPENSER
SEAT COVER
DISP.
FIRE
EXTINGUISH
ER
CABINET
FLUSH
CONTROL
TO BE ON OPEN
SIDE - TYP.
ACCESSIBLE / NON-ACCESSIBLE
WALL OR
OBSTRUCTION
VERTICAL
GRAB
BAR
RR R
TYP.
CL
3"
3' -6
M
A X
ELEC.
HAND
DRYER
ELEC. HAND
DRYER
DETAIL NUMBER
DETAIL TITLE
DETAIL SCALE
SECTION I.D. NUMBER
DRAWING TITLE
SHEET WHERE
SECTION IS LOCATED
NOTE (IF
APPLICABLE)
SECTION
DETAIL (ENLARGED)
A101
SIM
AREA TO BE ENLARGED
DETAIL I.D. NUMBER
SHEET WHERE
DETAIL IS LOCATED
ELEVATION ELEVATION I.D.
NUMBER
SHEET WHERE
ELEVATION IS LOCATED
DOOR NUMBER
101 DOOR NUMBER
WINDOW
1t WINDOW
IDENTIFICATIO
N
FINISH
ACM-1 FINISH
IDENTIFICATIO
N
KEYED NOTES
KEYED NOTE
DESIGNATION
REVISIONS
REVISION AREA
REVISION DESIGNATION
ELEVATION HEIGHT
ELEVATION HEIGHT
100'-0"
T.O.S.
ELEVATION REFERENCE
SCALE |1/4" = 1'-0"
floor plan1
NOTE (IF
APPLICABLE)
ROOM
NAME
ROOM ROOM NAME
ROOM NUMBER
A101
SIM
COLUMN LINE
NEW DOOR
EXISTING DOOR
A101
SIM
P1
SET BOTTOM TRACK AND
GYP BD. IN (4) CONT.
BEADS OF ACOUSTICAL
SEALANT
METAL STUD RUNNER
TRACK.
3-5/8" MTL STUDS
SOUND BATT
INSUL.
SOUND BATT INSUL.
SET TOP TRACK AND GYP
BD. IN (4) CONT. BEADS OF
ACOUSTICAL SEALANT
TOP TRACK. FASTEN
GYPSUM BOARD TO
STUDS NOT TO TOP
TRACK
P2 SAME AS P1 BUT WITH 2 LAYERS OF
GYP (FOR RATING)
P3 6" FRAMING W/ 6" BATT INSUL
P4
METAL STUD RUNNER TRACK.
SOUND BATT INSUL.
SOUND BATT INSUL.
TOP TRACK. FASTEN
GYPSUM BOARD TO
STUDS NOT TO TOP
TRACK
METAL STUD
RUNNER TRACK.
STUDS SCREWED AT
BOTTOM
3-5/8" MTL STUDS
W/ 1 LAYER 5/8"
GYP BOARD THIS
SIDE - PAINT TO
MATCH ADJACENT
COLOR
TOP TRACK. FASTEN
GYPSUM BOARD TO
STUDS NOT TO TOP
TRACK
RUBBER BASE
P5
P6
METAL STUD RUNNER
TRACK. STUDS SCREWED
ON EA. SIDE AT TOP &
BOTTOM
METAL STUD
RUNNER TRACK.
STUDS
SCREWED ON
EA. SIDE AT TOP
& BOTTOM
3-5/8" MTL STUDS W/ 1
LAYER 5/8" GYP
BOARD EACH SIDE &
WRAP BOTTOM
3-5/8" MTL STUDS W/
1 LAYER 5/8" GYP
BOARD EACH SIDE
5/8" GYP. BOARD EA.
SIDE -TYPE "X"
3-5/8" MTL STUDS
5/8" GYP. BOARD EA. SIDE -
TYPE "X"
NOTE:
1. NOT ALL PARTITION TYPES USED.
2. ALL PARTITIONS ARE TO BE TYPE 'X' GYPSUM BOARD
TO 8'-0" A.F.F.
3. FIRE RATED CAULKING INSTEAD OF ACOUSTICAL SEALANT IN FIRE/SMOKE BARRIERS.
1" THICK WOOD
CAP - CLEAR
STAINED BIRCH
5' -0
HOLD P4 WALL TIGHT TO EXISTING WALL UNLESS
SHOWN OTHERWISE
P7
8" CMU WALL
CONTINUE GYP
BOARD TO 4" ABOVE
FINISH CEILING
U.N.O.
IF NO CEILING
RUN TO DECK
OR
STRUCTURE
ABOVE
WALL TYPE DESIGNATION
HOUR RATING
* ALL RATED METAL STUD PARTITIONS SHALL BE UL#U141
* ALL RATED CONCRETE BLOCK WALL SHALL BE UL #905
CEILING: SEE PLANS
TOTAL WALL
STC RATING: 52
TOTAL WALL
STC RATING: 52
SET TOP TRACK AND GYP
BD. IN (3) CONT. BEADS OF
ACOUSTICAL SEALANT
SET BOTTOM TRACK AND
GYP BD. IN (3) CONT.
BEADS OF ACOUSTICAL
SEALANT
SET BOTTOM TRACK IN (2)
CONT. BEADS OF
ACOUSTICAL SEALANT
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
52109.00
3/
/2
2:
:2
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
STANDARDS INDEX
G002
WSVP/BW
539-17-201
Cincinnati, Ohio symbols ceiling symbols material indications wall types typical plan and wall details abbreviations mounting heights - adultpartition types
Revision s
Date
UP
UP
UP
UP
UP
UP
DN
DN
Machine Room C121L
Machine Room C121M
Stair #1 C122L
EXIT
S1
SMOKE COMPARTMENT 3,647 SF.
SHAFT OPEN
TO BELOW
SHAFT
NINTH FLOOR ROOF
NINTH FLOOR ROOF
TENTH FLOOR ROOF
AHU
AHU
AHU
AHU
AHU
AHU
Machine & Tank Room
C121O
Hoist Machinery
EXIT S1
EXIT S2
SMOKE COMPARTMENT 1,958 SF.
ELEVENTH FLOOR
ROOF
ELEVENTH FLOOR ROOF
OPEN TO
BELOW
2 HOUR FIRE/SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER
FIRE WALLS LEGEND
LIMITS OF SMOKE COMPARTMENT
EXISTING EQUIPMENT VERIFY
LOCATION IN FIELD
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
52109.00
3/
/2
2:
:3
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
CODE REVIEW
G003
WSVP/BW
539-17-201
Cincinnati, Ohio
Use and Occupancy Group Occupancy Group Health Care (NO CHANGE)
6.1.14.1.3 Where incidental to another occupancy areas used shall be permitted to be considered part of the predominant occupancy: (1) Mercantile, business, industrial or storage use.(NO CHANGE)
Construction Type II 222 (NO CHANGE) Total Building Height 112'-6", 11 Stories (NO CHANGE) Total Building Area NO CHANGE
Area Calculations Based on HC Use Allowable Building Area – Section 7.4.1Sprinklered Unlimited (NO CHANGE) Allowable Building Height 180 feet,12 stories (NO CHANGE)
TOTAL Allowable Building Height 112'-6" feet, 11 stories (NO CHANGE)
Accessible Means of Egress (Section 7.12.2) (NO CHANGE) Stories use exclusively for mechanical equipment, furnaces, or boilers shall be permitted to have a single means of egress.
Fire Resistance Rating Requirements (Table 7.2.2) –Type II222 Construction (NO CHANGE) Primary Structural Frame 2 Hours Bearing Walls Exterior 2 Hours Bearing Walls Interior 2 Hours Nonbearing Walls and Partitions Interior 0 Hours(Smoke Rated) Floor Construction 2 Hours Roof Construction and Secondary Members 1 Hours
Occupant Load (Table 7.4.1.2) (NO CHANGE) Floor SF OCC/SF OCC.
Tenth Floor Penthouse 3,642 100 36 Eleventh Floor Penthouse 1,958 100 20
Smoke Barriers (NO CHANGE)
8.5.1 Where required smoke barriers shall be provided to sub-divide the building spaces for the purpose of restricting the movement of smoke.
8.5.2.1 Smoke barriers shall be continuous from a floor to a floor.
8.5.3 A fire barrier shall be used as a smoke barrier.
Vertical Openings (NO CHANGE)
8.6.1 Every floor that separates stories in a building shall meet the following criteria:
(1) It shall be constructed as a smoke barrier in accordance with Section 8.5.
Automatic Sprinkler System (Section 9.7, and Section 18.3.5.4) (NO CHANGE) Required and provided
Fire Alarm System (Section 9.6 and Section 18.3.4.1 (NO CHANGE) Fire Alarm System required and provided
Health Care (Chapter 18) (NO CHANGE)
18.3.1 Any vertical opening shall be enclosed or protected in accordance with Section 8.6.
18.3.7 Buildings containing health care facilities shall be subdivided by smoke barriers, unless otherwise permitted.
18.3.7.3 The size of each smoke compartment will be limited to an area not exceeding 22,500 sf.
2009 NFPA 101 LIFE SAFETY CODE (WITH UPDATES)
SCALE | 1/8" = 1'-0"
TENTH FLOOR MECH. PENTHOUSE CODE PLAN1SCALE | 1/8" = 1'-0"
ELEVENTH FLOOR MECH. PENTHOUSE CODE PLAN2
Revision s
Date
100% BID DOCUMENTS 03/13/2019
N O
R T
H
N O
R
H
UP Corridor C-B-1
Corridor C-B-3
Canteen Stor.
A034
Non-Res.
Lounge A026
Stair 1 A024
Sig.
A025
Corridor C-B-1
Walk-In Freezer A0021a
Corridor A0010
Tele. Equip.
Rm.
A035
Dry Goods/Paper
Stor.
A0006
Supervisor A0012
Office A0013
3'
19' - 0" 8' - 5"
7'
Corridor C-1-1
Operator's Suite A175
Tlt.
A175A
Sig.
A141A
Stair 1 A141
Elec.
A143
Closet A141B
10 1
8' -4
V
IF
4'-9" VIF
2 HOUR FIRE/SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER
LEGEND
AREA NOT IN CONTRACT
EXISTING EQUIPMENT VERIFY
LOCATION IN FIELD
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
52109.00
3/
/2
2:
:0
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
SIGNALS CLOSET DEMOLITION
PLANS
A101
WSVP/BW
539-17-201
Cincinnati, Ohio
SCALE | 1/8" = 1'-0"
BASEMENT PARTIAL DEMOLITION PLAN1SCALE | 1/8" = 1'-0"
TYPICAL SIGNALS CLOSET DEMOLITION2
General Demolition Notes
A. MAINTAIN ANY IN-PLACE FIREPROOFING.
B. REFER TO CODE SHEETS FOR FIRE-RATED ASSEMBLY TYPES AND
LOCATIONS.
C. PATCH/REPAIR SURFACES AS REQUIRED FOR ANY NEW FINISHES.
INCLUDING AREAS THAT WILL BE EXPOSED AS A RESULT OF THIS
PROJECT. MATCH ADJACENT FINISHES.
D. IN ANY AREAS OF PATCH/REPAIR, CONTRACTOR SHALL ASSUME
PAINT/FINISH WILL BE REQUIRED CORNER TO CORNER ONLY IN PUBLIC
SPACES SUCH AS CORRIDORS AND LOBBIES.
E. GENERAL CONTRACTOR SHALL COORDINATE ALL DEMOLITION EFFORTS
BY ALL TRADES.
F. DEMO WORK FOR PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS
SHALL OCCUR BEYOND EXTENT OF WORK AS REQUIRED FOR
COMPLETION OF WORK. CONTRACTOR TO PREPARE ANY EXISTING AREA
BEYOND EXTENT OF WORK FOR INSTALLATION OF NEW SYSTEMS . SEE
PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS.
G. ALL DEMO TO BE BY ALL TRADES. SEE PME DRAWINGS FOR MORE
INFORMATION.
H. SEE FLOOR PLANS FOR NEW WORK TO BE DONE.
I. REMOVE ALL EXISTING WALLS AND FURRING TO EXPOSE AREAS TO
RECEIVE WORK, UNLESS NOTED OTHERWISE.
J. THERE ARE NO KNOWN ACM (ASBESTOS CONTAINING MATERIALS) IN THE
AREA OF WORK. IF ANY SUSPICIOUS OR POSITIVE ACM ARE
ENCOUNTERED NOTIFY THE COR IMMEDIATELY.
K. REMOVE ALL WALL HUNG ACCESSORIES AND OBJECTS PROTRUDING
FROM WALLS IN THE AREA OF REQUIRED DEMOLITION WORK. TURN ALL
EQUIPMENT OVER TO THE OWNER.
L. PROTECT ALL EXISTING DOORS, DOORFRAMES, WINDOWS, STAIRS,
CEILINGS, ETC. IN THE AREA OF WORK NOT SCHEDULED TO BE
DEMOLISHED. DOCUMENT EXISTING CONDITIONS WITH THE COR PRIOR TO
BEGINNING WORK.
M. CONTRACTOR IS RESPONSIBLE FOR CREATING A LEVEL FLOOR
FOLLOWING REMOVAL OF EXISTING CONSTRUCTION. CONTRACTOR TO
ASSUME NO SURFACE INSIDE SIGNALS CLOSETS OR TELEPHONE
EQUIPMENT ROOM WILL REQUIRE PATCHING AND LEVELING. ONLY
SURFACE WORK IN CORRIDORS OR LOBBIES WILL REQUIRE PATCHING
WITH FLOWABLE HIGH STRENGTH CEMENTITIOUS FILL UPON
COMPLETION OF WORK AS REQUIRED. FEATHER ALL EDGES TO MATCH
ALL EXISTING SLAB CONDITIONS AND ELEVATIONS REQUIRED TO INSTALL
NEW OR REPAIR EXISTING FLOOR FINISHES.
N. WORK IN ELEVATOR LOBBIES INCLUDING, BUT NOT LIMITED TO
OPERATING ROOM SUITES AND MAIN FIRST FLOOR CORRIDOR WILL BE
DONE BETWEEN THE HOURS OF 1800 AND 0600. COORDINATE TIMES OF
ACCESS WITH THE COR. THE AREA OF WORK WILL BE RETURNED TO A
CLEAN AND ORDERLY CONDITION MEETING ALL REQUIREMENTS AS SET
FORTH BY THE GENERAL CONDITIONS AND OPERATING RULES OF THE
VAMC, AT THE END OF EACH WORK DAY.
O. FLOOR SLABS ARE CONSIDERED TO BE CONCRETE WITH STEEL
REINFORCEMENT. ALL WALLS ARE CONSIDERED TO BE OF MASONRY
CONSTRUCTION EXCEPT THOSE INDICATED OTHERWISE.
P. SEE TECHNOLOGY DRAWINGS FOR EXTENT AND SCOPE OF CEILING TILE
REMOVAL, REPLACEMENT AND REINSTALLATION INCLUDING, BUT NOT
LIMITED TO CORRIDORS, EXAM ROOMS AND SUITES.
N O
R T
H
N O
R T
H
DEMOLITION PLAN NOTES
SCALE | 1" = 50'-0"
KEY PLAN4
SCALE | 1" = 50'-0"
KEY PLAN BASEMENT3
N O
R T
H
N O
R T
H
1. CONTRACTOR TO PREP ALL EXPOSED/PUBLIC AREAS OF CEILING, WALLS AND FLOOR FOR RE-PAINTING, RE-
FINISHING AS REQUIRED TO MATCH EXISTING CONDITIONS.
2. CORE DRILL SUSPENDED SLAB NO LESS THAN SIX INCHES FROM EDGE OF BEAM FOR NEW WIRING CONDUIT.
DO NOT DRILL THRU BEAM OR BEAM FLANGE. SEE TECHNOLOGY DRAWINGS FOR CONDUIT SIZE.
3. REMOVE AND DISPOSE OF ANY DISPLAY SURFACES PER THE DIRECTION OF THE COR.
4. CORE DRILL APPROXIMATELY 1'-0" THICK EXTERIOR MASONRY WALL WITH FILLED CORES BELOW
STRUCTURAL PERIMETER BEAM FOR NEW ANTENNA FEED. SEE TECHNOLOGY DRAWINGS FOR LOCATION OF
NEW ANTENNA MOUNT
5. AREAS OF THE FLOOR THAT ARE TO BE EXPOSED, SEALED CONCRETE THE CONTRACTOR SHALL PREP/OVERLAY AS REQUIRED WITH FLOWABLE HIGH STRENGTH CEMENTITIOUS FILL TO CREATE SMOOTH, EVEN SURFACE AS REQUIRED. MATCH EXISTING FINISHES.
6. REMOVE PORTION OF CEILING TILE AS REQUIRED TO INSTALL NEW BDA, ANTENNA AND CABLING. SEE
TECHNOLOGY DRAWINGS.
7. ON BASEMENT FLOOR CORE DRILL THROUGH WALL ABOVE CORRIDOR CEILING AND DOOR HEADER TO PROVIDE CONDUIT ACCESS TO TELEPHONE EQUIPMENT ROOM. SEE TECHNOLOGY DRAWINGS FOR CONDUIT
SIZE.
8. PROTECT EXISTING AIR HANDLING UNITS AND DUCTWORK IN AREA OF WORK.
9. REMOVE OR RELOCATE ALL EXISTING WALL HUNG EQUIPMENT, CONDUIT AND ACCESSORIES AS REQUIRED
TO CREATE AN UN-OBSTRUCTED PATH FOR NEW WIRING CONDUIT. SEE TECHNOLOGY DRAWINGS FOR EXACT
PATH.
10. COORDINATE EXACT LIMITS OF CONSTRUCTION IN THE FIELD WITH THE COR.
11. PROVIDE GROUNDING FOR LIGHTENING PROTECTION. SEE TECHNOLOGY DRAWINGS.
12. EXISTING PULLBOX.
13. CORE DRILL THROUGH WALL ABOVE CORRIDOR CEILING AND DOOR HEADER TO PROVIDE CONDUIT ACCESS
TO CORRIDOR. SEE TECHNOLOGY DRAWINGS FOR CONDUIT SIZE.
14. LINE OF SLAB EDGE/EXTERIOR WALL ABOVE.
Revision s
UP
U
PU
P
UP
DN
UP
DN
AHU
AHU
AHU
AHU
AHU
AHU
Machine Room C121L
NINTH FLOOR ROOF
NINTH FLOOR ROOF
TENTH FLOOR ROOF
Machine Room C121M
13' - 4" VIF 2' - 0"
4'
Machine & Tank Room
C121O 10
HOIST
MACHINERY
TENTH FLOOR ROOF
TENTH FLOOR
ROOF
V
IF
13'-4" VIF
OPEN TO
BELOW
2 HOUR FIRE/SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER
LEGEND
AREA NOT IN CONTRACT
EXISTING EQUIPMENT VERIFY
LOCATION IN FIELD
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
52109.00
3/
/2
2:
:0
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
TENTH-ELEVENTH FLOOR
PENTHOUSE DEMOLITION PLANS
A102
WSVP/BW
539-17-201
Cincinnati, Ohio
SCALE | 1/8" = 1'-0"
DEMOLITION TENTH FLOOR PENTHOUSE1SCALE | 1/8" = 1'-0"
DEMOLITION ELEVENTH FLOOR PENTHOUSE2 N
O
R T
H
N O
R T
H
General Demolition NotesDEMOLITION PLAN NOTES
1. CONTRACTOR TO PREP ALL EXPOSED/PUBLIC AREAS OF CEILING, WALLS AND FLOOR FOR RE-
PAINTING, RE-FINISHING AS REQUIRED TO MATCH EXISTING CONDITIONS.
2. CORE DRILL SUSPENDED SLAB NO LESS THAN SIX INCHES FROM EDGE OF BEAM FOR NEW WIRING
CONDUIT. DO NOT DRILL THRU BEAM OR BEAM FLANGE. SEE TECHNOLOGY DRAWINGS FOR CONDUIT
SIZE.
3. REMOVE AND DISPOSE OF ANY DISPLAY SURFACES PER THE DIRECTION OF THE COR.
4. CORE DRILL APPROXIMATELY 1'-0" THICK FILLED CORES EXTERIOR MASONRY WALL BELOW
STRUCTURAL PERIMETER BEAM FOR NEW ANTENNA FEED. SEE TECHNOLOGY DRAWINGS FOR
LOCATION OF NEW ANTENNA MOUNT
5. AREAS OF THE FLOOR THAT ARE TO BE EXPOSED, SEALED CONCRETE THE CONTRACTOR SHALL
PREP/OVERLAY AS REQUIRED WITH FLOWABLE HIGH STRENGTH CEMENTITIOUS FILL TO CREATE
SMOOTH, EVEN SURFACE AS REQUIRED. MATCH EXISTING FINISHES.
6. REMOVE PORTION OF CEILING TILE AS REQUIRED TO INSTALL NEW BDA, ANTENNA AND CABLING. SEE
TECHNOLOGY DRAWINGS.
7. ON BASEMENT FLOOR CORE DRILL THROUGH WALL ABOVE CORRIDOR CEILING AND DOOR HEADER
TO PROVIDE CONDUIT ACCESS TO TELEPHONE EQUIPMENT ROOM. SEE TECHNOLOGY DRAWINGS
FOR CONDUIT SIZE.
8. PROTECT EXISTING AIR HANDLING UNITS AND DUCTWORK IN AREA OF WORK.
9. REMOVE OR RELOCATE ALL EXISTING WALL HUNG EQUIPMENT, CONDUIT AND ACCESSORIES AS
REQUIRED TO CREATE AN UN-OBSTRUCTED PATH FOR NEW WIRING CONDUIT. SEE TECHNOLOGY
DRAWINGS FOR EXACT PATH.
10. COORDINATE EXACT LIMITS OF CONSTRUCTION IN THE FIELD WITH THE COR.
11. PROVIDE GROUNDING FOR LIGHTENING PROTECTION. SEE TECHNOLOGY DRAWINGS.
12. EXISTING PULLBOX.
13. CORE DRILL THROUGH WALL ABOVE CORRIDOR CEILING AND DOOR HEADER TO PROVIDE CONDUIT
ACCESS TO CORRIDOR. SEE TECHNOLOGY DRAWINGS FOR CONDUIT SIZE.
14. LINE OF SLAB EDGE/EXTERIOR WALL ABOVE.
A. MAINTAIN ANY IN-PLACE FIREPROOFING.
B. REFER TO CODE SHEETS FOR FIRE-RATED ASSEMBLY TYPES AND
LOCATIONS.
C. PATCH/REPAIR SURFACES AS REQUIRED FOR ANY NEW FINISHES.
INCLUDING AREAS THAT WILL BE EXPOSED AS A RESULT OF THIS
PROJECT. MATCH ADJACENT FINISHES.
D. IN ANY AREAS OF PATCH/REPAIR, CONTRACTOR SHALL ASSUME
PAINT/FINISH WILL BE REQUIRED CORNER TO CORNER ONLY IN PUBLIC
SPACES SUCH AS CORRIDORS AND LOBBIES.
E. GENERAL CONTRACTOR SHALL COORDINATE ALL DEMOLITION EFFORTS
BY ALL TRADES.
F. DEMO WORK FOR PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS
SHALL OCCUR BEYOND EXTENT OF WORK AS REQUIRED FOR
COMPLETION OF WORK. CONTRACTOR TO PREPARE ANY EXISTING AREA
BEYOND EXTENT OF WORK FOR INSTALLATION OF NEW SYSTEMS . SEE
PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS.
G. ALL DEMO TO BE BY ALL TRADES. SEE PME DRAWINGS FOR MORE
INFORMATION.
H. SEE FLOOR PLANS FOR NEW WORK TO BE DONE.
I. REMOVE ALL EXISTING WALLS AND FURRING TO EXPOSE AREAS TO
RECEIVE WORK, UNLESS NOTED OTHERWISE.
J. THERE ARE NO KNOWN ACM (ASBESTOS CONTAINING MATERIALS) IN THE
AREA OF WORK. IF ANY SUSPICIOUS OR POSITIVE ACM ARE
ENCOUNTERED NOTIFY THE COR IMMEDIATELY.
K. REMOVE ALL WALL HUNG ACCESSORIES AND OBJECTS PROTRUDING
FROM WALLS IN THE AREA OF REQUIRED DEMOLITION WORK. TURN ALL
EQUIPMENT OVER TO THE OWNER.
L. PROTECT ALL EXISTING DOORS, DOORFRAMES, WINDOWS, STAIRS,
CEILINGS, ETC. IN THE AREA OF WORK NOT SCHEDULED TO BE
DEMOLISHED. DOCUMENT EXISTING CONDITIONS WITH THE COR PRIOR TO
BEGINNING WORK.
M. CONTRACTOR IS RESPONSIBLE FOR CREATING A LEVEL FLOOR
FOLLOWING REMOVAL OF EXISTING CONSTRUCTION. CONTRACTOR TO
ASSUME NO SURFACE INSIDE SIGNALS CLOSETS OR TELEPHONE
EQUIPMENT ROOM WILL REQUIRE PATCHING AND LEVELING. ONLY
SURFACE WORK IN CORRIDORS OR LOBBIES WILL REQUIRE PATCHING
WITH FLOWABLE HIGH STRENGTH CEMENTITIOUS FILL UPON
COMPLETION OF WORK AS REQUIRED. FEATHER ALL EDGES TO MATCH
ALL EXISTING SLAB CONDITIONS AND ELEVATIONS REQUIRED TO INSTALL
NEW OR REPAIR EXISTING FLOOR FINISHES.
N. WORK IN ELEVATOR LOBBIES INCLUDING, BUT NOT LIMITED TO
OPERATING ROOM SUITES AND MAIN FIRST FLOOR CORRIDOR WILL BE
DONE BETWEEN THE HOURS OF 1800 AND 0600. COORDINATE TIMES OF
ACCESS WITH THE COR. THE AREA OF WORK WILL BE RETURNED TO A
CLEAN AND ORDERLY CONDITION MEETING ALL REQUIREMENTS AS SET
FORTH BY THE GENERAL CONDITIONS AND OPERATING RULES OF THE
VAMC, AT THE END OF EACH WORK DAY.
O. FLOOR SLABS ARE CONSIDERED TO BE CONCRETE WITH STEEL
REINFORCEMENT. ALL WALLS ARE CONSIDERED TO BE OF MASONRY
CONSTRUCTION EXCEPT THOSE INDICATED OTHERWISE.
P. SEE TECHNOLOGY DRAWINGS FOR EXTENT AND SCOPE OF CEILING TILE
REMOVAL, REPLACEMENT AND REINSTALLATION INCLUDING, BUT NOT
LIMITED TO CORRIDORS, EXAM ROOMS AND SUITES.
Revision s
UP
DN
Corridor C-B-1
Corridor C-B-3
Canteen Stor.
A034
Non-Res.
Lounge A026
Stair 1 A024
Sig.
A025
Corridor C-B-1
Walk-In Freezer A0021a
Corridor A0010
Tele. Equip.
Rm.
A035
Dry Goods/Paper
Stor.
A0006
Supervisor A0012
Office A0013
19' - 0" 8' - 5"
3'
7'
Tele.
A025A
Corridor C-1-1
Operator's Suite A175
Tlt.
A175A
Sig.
A141A
Stair 1 A141
Elec.
A143
Closet A141B
8' -4
V
IF
4'-9" VIF 9' - 11 3/8"
2 HOUR FIRE/SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER
LEGEND
AREA NOT IN CONTRACT
EXISTING EQUIPMENT VERIFY
LOCATION IN FIELD
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
52109.00
3/
/2
2:
:2
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
SIGNALS CLOSET NEW WORK
PLANS
A103
WSVP/BW
539-17-201
Cincinnati, Ohio
SCALE | 1/8" = 1'-0"
BASEMENT NEW WORK1 N
O R
T H
SCALE | 1/8" = 1'-0"
TYPICAL SIGNALS CLOSET NEW WORK2 N
O R
T H
Floor Plan Notes General Notes A. PLUMBING, MECHANICAL, ELECTRICAL AND TECHNOLOGY SYSTEMS WORK SHALL OCCUR BEYOND THE
EXTENT OF WORK LINE AS REQUIRED. CONTRACTOR SHALL PATCH & REPAIR ANY EXISTING AREAS BEYOND EXTENT OF WORKLINE DAMAGED BY SUCH WORK. SEE MECHANICAL, ELECTRICAL, PLUMBING
AND TECHNOLOGY DRAWINGS.
B. PRIOR TO GYPSUM BOARD INSTALLATION AND ELECTRICAL ROUGH-IN INSPECTION, GENERAL
CONTRACTORS, ELECTRICAL/DATA CONTRACTORS, COR, AND CONSTRUCTION MANAGER SHALL
REVIEW IN-PLACE LOCATIONS OF ALL SWITCH BOXES, RECEPTACLE BOXES, FIRE ALARM BOXES, ETC.
FINAL LOCATIONS MAY BE ADJUSTED AT THIS TIME TO ALIGN OR COORDINATE WITH DESIGN INTENT.
C. ALL TWO-SIDED NEW INTERIOR PARTITIONS ARE P-1 UNLESS NOTED OTHERWISE.
D. ALL ONE-SIDED INTERIOR PARTITIONS ARE P-4 UNLESS NOTED OTHERWISE.
E. ALL WALLS ARE FULL HEIGHT TO DECK ABOVE, UNLESS NOTED OTHERWISE.
F. ALIGN ALL NEW WORK WITH EXISTING AS SHOWN, INDICATED OR ABUTTING
G. RUN ALL UTILITIES AS TIGHT TO STRUCTURE AS POSSIBLE. GENERAL CONTRACTOR TO COORDINATE
ALL TRADES AS REQUIRED TO AVOID CONFLICTS.
H. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING EXISTING CEILING TILE AND GRID UP TO THE
NEAREST TILE AS REQUIRED IN ORDER TO INSTALL NEW CABLE, HANGERS, JUNCTION BOXES,
ANTENNA, OUTLETS, ETC. CEILING TILE WILL BE CAREFULLY REMOVED AND STORED ON SITE OUT OF
THE IMMEDIATE CONSTRUCTION AREA. STORAGE AREA TO BE COORDINATED WITH THE COR. AT
THE END OF THE WORK DAY ALL TILE TEMPORARILY REMOVED TO COMATE WORK WILL BE RE-
INSTALLED UNLESS APPROVED OTHERWISE BY THE COR. AT THE BEGINNING OF WORK IN EACH
CORRIDOR THE CONTRACTOR WILL DOCUMENT ALONG WITH THE COR THE CONDITION OF THE
EXISTING CEILING TILE AND GRID, NOTING THOSE AREAS THAT BEGIN THE PROJECT AS DAMAGED, STAINED, MISSING, ETC. ANY TILE THAT APPEAR DAMAGED, LOST OR ALTERED BY THE CONTRACTOR AT THE CONCLUSION OF CONSTRUCTION WILL BE REPLACED ALONG WITH ANY AFFECTED GRID BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.
1. PROTECT EXISTING AIR HANDLERS, DUCTS AND EQUIPMENTS DURING CONSTRUCTION.
2. PROTECT EXISTING DOOR AND FRAME DURING CONSTRUCTION.
3. REPAIR PLYWOOD WALL SHEATHING IS IMMEDIATE AREA OF CONSTRUCTION INSIDE
SIGNALS/ELECTRIC CLOSETS AS REQUIRED IN ORDER TO RETURN SURFACES TO PER-CONSTRUCTION
LIKE CONDITION.
4. LINE OF ELEVENTH FLOOR SLAB EDGE/EXTERIOR WALL ABOVE
5. SEAL ALL FLOOR TO CEILING PENETRATIONS WITH TWO HOUR RATED FIRE CAULK/SEALANT.
6. TOUCH-UP WALLS AND REPAIR FLOOR IS IMMEDIATE AREA OF CONSTRUCTION AS REQUIRED IN ORDER
TO RETURN SURFACES TO PER-CONSTRUCTION LIKE CONDITION. CONFIRM WITH COR PRIOR TO
PERFORMING WORK THAT ANY VISIBLE SURFACE IN NON-PUBLIC SPACES REQUIRES A NEW FINISH.
7. SEAL ALL EXTERIOR WALL PENETRATION WITH WATERPROOF EXPANDABLE SEALANT TO MATCH THE
EXISTING MASONRY COLOR.
8. SEAL ALL VERTICAL INTERIOR PENETRATIONS FLUSH WITH THE EXISTING SURFACE. TOUCH-UP WALL
TO MATCH ALL EXISTING CONDITIONS.
9. SEAL ALL PENETRATION IN EXISTING VERTICAL PULLBOX/CLOSETS WITH TWO HOUR FIRE RESISTIVE
SEALANT.
10. SEE TECHNOLOGY PLANS FOR ANTENNA MOUNTING LOCATION AND DETAILS.
11. SEAL PENETRATIONS IN NON-RATED WALLS WITH APPROVED SEALANT TO RESIST THE PASSAGE OF
SMOKE.
12. COORDINATE EXACT LIMITS OF CONSTRUCTION IN THE FIELD WITH THE COR.
13. PROVIDE CLEAR UNOBSTRUCTED ROUTE FOR MOUNTING ANTENNA CONDUIT. SEE TECHNOLOGY
PLANS.
14. GROUT MASONRY CELLS FULL IF NOT ALREADY, DIRECTLY ADJACENT TO AND ABOVE AND BELOW
EXTERIOR WALL PENETRATION PROVIDING ACCESS FOR RADIO ANTENNA CABLING CONDUIT. SEE
TECHNOLOGY DRAWINGS.
SCALE | 1" = 50'-0"
KEY PLAN BASEMENT3SCALE | 1" = 50'-0"
KEY PLAN4 N
O
R T
H
N O
R T
H
Revision s
UP
UP
DN
UP
DN
AHU
AHU
AHU
AHU
AHU
AHU
Machine Room C121L
NINTH FLOOR ROOF
NINTH FLOOR ROOF
TENTH FLOOR ROOF
Machine Room C121M
13' - 4" VIF 2' - 0"
4'
Machine & Tank Room
C121O
HOIST
MACHINERY
TENTH FLOOR ROOF
TENTH FLOOR
ROOF
OPEN TO
BELOW
V
IF
13'-4" VIF
2 HOUR FIRE/SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER
LEGEND
AREA NOT IN CONTRACT
EXISTING EQUIPMENT VERIFY
LOCATION IN FIELD
S
T A T E
OF OH
IO
R E G
IST ERED A RC
HI
T
E C T
JAMES
W.
WILLIAMS
James W. Williams, License #9266 Expiration Date 12/31/2019
Drawing Title
Approved: Project Director
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
HEAPY PROJECT No.: 2015-04002 FIRM LICENSE No.: 01528
52109.00
3/
/2
2:
:2
P
M
UPGRADE FIRE RADIO
SYSTEM
03/13/19
TENTH-ELEVENTH FLOOR
PENTHOUSE NEW WORK PLANS
A104
WSVP/BW
539-17-201
Cincinnati, Ohio
SCALE | 1/8" = 1'-0"
TENTH FLOOR PENTHOUSE NEW WORK1SCALE | 1/8" = 1'-0"
ELEVENTH FLOOR PENTHOUSE NEW WORK2
General NotesFloor Plan Notes
N O
R T
H
N O
R T
H
1. PROTECT EXISTING AIR HANDLERS, DUCTS AND EQUIPMENTS DURING CONSTRUCTION.
2. PROTECT EXISTING DOOR AND FRAME DURING CONSTRUCTION.
3. REPAIR PLYWOOD WALL SHEATHING IS IMMEDIATE AREA OF CONSTRUCTION INSIDE
SIGNALS/ELECTRIC CLOSETS AS REQUIRED IN ORDER TO RETURN SURFACES TO PER-CONSTRUCTION
LIKE CONDITION.
4. LINE OF ELEVENTH FLOOR SLAB EDGE/EXTERIOR WALL ABOVE
5. SEAL ALL FLOOR TO CEILING PENETRATIONS WITH TWO HOUR RATED FIRE CAULK/SEALANT.
6. TOUCH-UP WALLS AND REPAIR FLOOR IS IMMEDIATE AREA OF CONSTRUCTION AS REQUIRED IN ORDER
TO RETURN SURFACES TO PER-CONSTRUCTION LIKE CONDITION. CONFIRM WITH COR PRIOR TO
PERFORMING WORK THAT ANY VISIBLE SURFACE IN NON-PUBLIC SPACES REQUIRES A NEW FINISH.
7. SEAL ALL EXTERIOR WALL PENETRATION WITH WATERPROOF EXPANDABLE SEALANT TO MATCH THE
EXISTING MASONRY COLOR.
8. SEAL ALL VERTICAL INTERIOR PENETRATIONS FLUSH WITH THE EXISTING SURFACE. TOUCH-UP WALL
TO MATCH ALL EXISTING CONDITIONS.
9. SEAL ALL PENETRATION IN EXISTING VERTICAL PULLBOX/CLOSETS WITH TWO HOUR FIRE RESISTIVE
SEALANT.
10. SEE TECHNOLOGY PLANS FOR ANTENNA MOUNTING LOCATION AND DETAILS.
11. SEAL PENETRATIONS IN NON-RATED WALLS WITH APPROVED SEALANT TO RESIST THE PASSAGE OF
SMOKE.
12. COORDINATE EXACT LIMITS OF CONSTRUCTION IN THE FIELD WITH THE COR.
13. PROVIDE CLEAR UNOBSTRUCTED ROUTE FOR MOUNTING ANTENNA CONDUIT. SEE TECHNOLOGY
PLANS.
14. GROUT MASONRY CELLS FULL IF NOT ALREADY, DIRECTLY ADJACENT TO AND ABOVE AND BELOW
EXTERIOR WALL PENETRATION PROVIDING ACCESS FOR RADIO ANTENNA CABLING CONDUIT. SEE
TECHNOLOGY DRAWINGS.
A. PLUMBING, MECHANICAL, ELECTRICAL AND TECHNOLOGY SYSTEMS WORK SHALL OCCUR BEYOND THE EXTENT OF WORK LINE AS REQUIRED. CONTRACTOR SHALL PATCH & REPAIR ANY EXISTING AREAS BEYOND EXTENT OF WORKLINE DAMAGED BY SUCH WORK. SEE MECHANICAL, ELECTRICAL, PLUMBING
AND TECHNOLOGY DRAWINGS.
B. PRIOR TO GYPSUM BOARD INSTALLATION AND ELECTRICAL ROUGH-IN INSPECTION, GENERAL
CONTRACTORS, ELECTRICAL/DATA CONTRACTORS, COR, AND CONSTRUCTION MANAGER SHALL
REVIEW IN-PLACE LOCATIONS OF ALL SWITCH BOXES, RECEPTACLE BOXES, FIRE ALARM BOXES, ETC.
FINAL LOCATIONS MAY BE ADJUSTED AT THIS TIME TO ALIGN OR COORDINATE WITH DESIGN INTENT.
C. ALL TWO-SIDED NEW INTERIOR PARTITIONS ARE P-1 UNLESS NOTED OTHERWISE.
D. ALL ONE-SIDED INTERIOR PARTITIONS ARE P-4 UNLESS NOTED OTHERWISE.
E. ALL WALLS ARE FULL HEIGHT TO DECK ABOVE, UNLESS NOTED OTHERWISE.
F. ALIGN ALL NEW WORK WITH EXISTING AS SHOWN, INDICATED OR ABUTTING
G. RUN ALL UTILITIES AS TIGHT TO STRUCTURE AS POSSIBLE. GENERAL CONTRACTOR TO COORDINATE
ALL TRADES AS REQUIRED TO AVOID CONFLICTS.
H. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING EXISTING CEILING TILE AND GRID UP TO THE
NEAREST TILE AS REQUIRED IN ORDER TO INSTALL NEW CABLE, HANGERS, JUNCTION BOXES,
ANTENNA, OUTLETS, ETC. CEILING TILE WILL BE CAREFULLY REMOVED AND STORED ON SITE OUT OF THEIMMEDIATE CONSTRUCTION AREA. STORAGE AREA TO BE COORDINATED WITH THE COR. AT THE END OF THE WORK DAY ALL TILE TEMPORARILY REMOVED TO COMATE WORK WILL BE RE-INSTALLED UNLESS APPROVED OTHERWISE BY THE COR. AT THE BEGINNING OF WORK IN EACH CORRIDOR THE CONTRACTOR WILL DOCUMENT ALONG WITH THE COR THE CONDITION OF THE EXISTING CEILING TILE AND GRID, NOTING THOSE AREAS THAT BEGIN THE PROJECT AS DAMAGED, STAINED, MISSING, ETC.
ANY TILE THAT APPEAR DAMAGED, LOST OR ALTERED BY THE CONTRACTOR AT THE CONCLUSION OF CONSTRUCTION WILL BE REPLACED ALONG WITH ANY AFFECTED GRID BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE GOVERNMENT.
Revision s
A. ALL ELECTRICAL SPLICES FOR W IRE SIZES 6 AW G AND LARGER SHALL BE HYDRAULIC CRIM P TYPE.
B. THESE NOTES APPLY EQUALLY TO THE FULL SET OF DOCUM ENTS.
C. SITE VISIT(S) SHALL BE AS OUTLINED IN PROJECT SPECIFICATIONS.
D. ANY ASBESTOS W ORK PERFORMED AS PART OF THIS PROJECT SHALL BE COM PLETED PRIOR TO STARTING ANY
OTHER PROJECT SITE W ORK.
E. THE NOTES AND SYM BOLS SET DOW N ON THESE DRAW INGS ARE FOR THE GUIDANCE OF ALL TRADES INVOLVED
IN THE PROJECT AND M UST BE FOLLOW ED TO EXECUTE THE W ORK AS INTENDED.
F. THE CONTRACTORS SHALL REFER TO ALL SPECIFICATION SECTIONS, AND ELECTRICAL DRAW INGS FOR DETAILS
OF BUILDING CONSTRUCTION TO ENSURE SPACE AND SATISFACTORY ARRANGEM ENT FOR THEIR W ORK. THE VARIOUS DRAW INGS COMPRISING THE SET ARE INTERDEPENDENT AND M UST BE USED JOINTLY AT ALL TIMES.
EACH CONTRACTOR SHOULD REFER TO THE GENERAL REQUIREMENTS OF THE CONTRACT. THESE NOTES AND SYM BOLS SET DOW N ON THE DRAW INGS ARE FOR THE GUIDANCE OF ALL TRADES INVOLVED IN THE PROJECT AND MUST BE FOLLOW ED TO EXECUTE THE W ORK AS INTENDED. IF DISCREPANCIES OCCUR, CONTACT THE COR THRU
THE CONTRACTING OFFICER FOR CLARIFICATION BEFORE PROCEEDING.
G . IN ACCORDANCE W ITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR W ILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORM ANCE OF THE W ORK. THIS W ILL APPLY CONTINUOUSLY AND NOT BE LIM ITED TO NORM AL W ORKING HOURS. SEE SPECIFICATIONS FOR MORE SPECIFIC DETAILS ON RESPONSIBILITIES.
H. ALL W ORK M UST BE COORDINATED W ITH THE COR TO M AINTAIN OPERATION OF THE EXISTING FACILITY.
I. FIELD VERIFY DIM ENSIONAL INFORMATION PRIOR TO ORDERING EQUIPMENT. DO NOT SCALE DRAW INGS.
J. DIM ENSIONS ARE TYPICALLY INDICATED TO THE FINISHED FACE OF W ALLS OR PARTITIONS AND CENTER LINES OF
COLUM NS UNLESS OTHERW ISE INDICATED.
K. TITLES, CAPTIONS, HEADINGS, ETC. ARE INTENDED FOR GENERAL REFERENCE AND ARE NOT INTENDED TO LIMIT
THE W ORK REQUIRED IN ANY W AY.
L. EACH CONTRACTOR SHALL COORDINATE HIS W ORK W ITH THE W ORK OF OTHERS. HE SHALL KEEP HIM SELF
INFORMED OF THE PROGRESS AND DETAIL DEVELOPMENT OF THE W ORK OF OTHERS AND SHALL BE RESPONSIBLE FOR COORDINATING AND EXPEDITING HIS W ORK W ITH OTHERS SO THAT THE PROGRESS OF THE
TOTAL W ORK SHALL BE KEPT ON SCHEDULE.
M . ALL W ORK SHALL BE PERFORM ED IN COMPLETE COM PLIANCE W ITH ALL GOVERNING CODES AND STANDARDS.
N. EXISTING CONDITIONS SHOW N HAVE BEEN BASED UPON AVAILABLE DRAW ING INFORM ATION, LIM ITED SITE
INVESTIGATIONS AND MAY BE AT VARIANCE W ITH ACTUAL W ORK IN PLACE. THE CONTRACTOR SHALL TAKE ALL NECESSARY FIELD MEASUREMENTS AND FIELD VERIFY ALL CONDITIONS AFFECTING THE EXECUTION OF THE W ORK. ANY DISCREPANCIES BETW EEN EXISTING CONDITIONS AND THE W ORK SHOW N ON THE CONTRACT DOCUM ENTS W HICH M AY IMPACT THE PROGRESS OF THE W ORK SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER IN W RITING FOR RESOLUTION BEFORE PROCEEDING W ITH THE W ORK.
O . EACH CONTRACTOR AND/OR TRADE FITTING OR PLACING HIS W ORK INTO OR ON THE W ORK OF OTHERS DOES SO W ITH THE UNDERSTANDING THAT THE INSTALLATION OF HIS W ORK CONSTITUTES HIS ACCEPTANCE OF THE SUITABILITY OF THE W ORK IN PLACE. IF THE W ORK OF OTHERS IS NOT ACCEPTABLE, HE SHALL NOTIFY THE COR AND SUCH W ORK SHALL BE CORRECTED. ANY NEW W ORK INSTALLED IN UNSUITABLE EXISTING W ORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE INSTALLING THE NEW W ORK. NO CLAIMS FOR ADDITIONAL COMPENSATION FOR CORRECTING W ORK INSTALLED IN UNSUITABLE EXISTING CONDITIONS W ILL BE
CONSIDERED.
P. ANY STRUCTURAL, M ECHANICAL, ELECTRICAL, FIRE PROTECTION, OR PLUM BING INFORM ATION INDICATED ON THE ARCHITECTURAL DRAW INGS IS FOR REFERENCE PURPOSES ONLY UNLESS OTHERW ISE INDICATED.
Q . IF, IN THE PERFORM ANCE OF THE ELECTRICAL W ORK, MATERIALS ARE OBSERVED W HICH ARE SUSPECTED TO CONTAIN ASBESTOS, THE ELECTRICAL CONTRACTOR SHALL IM MEDIATELY INFORM THE COR. W ORK THAT W OULD EXPOSE W ORKERS TO THE INHALATION OF ASBESTOS PARTICLES SHALL BE TERM INATED. W ORK MAY BE RESUM ED ONLY AFTER A DETERMINATION HAS BEEN M ADE AND UNSAFE MATERIALS HAVE BEEN REM OVED OR
ENCAPSULATED AND THE AREA DECLARED SAFE.
R. PROPER PERSONNEL PROTECTION EQUIPMENT SHALL BE W ORN PER OSHA AND VA REQUIREM ENTS W ITH VAMC
COR AND SAFETY OFFICER.
S. FIRESTOPPING ASSEM BLIES SHALL BE PROVIDED AT PENETRATIONS OF CONDUITS AND OTHER ELECTRICAL ITEMS THRU FIRE RATED FLOORS, FIRE RATED W ALLS AND PARTITIONS AND FIRE RATED SHAFT W ALLS AND PARTITIONS.
ALL PENETRATIONS THROUGH 0-HOUR RATED W ALLS SHALL BE CAULKED SM OKE-TIGHT. REFER TO
SPECIFICATION SECTION 07 84 00.
T. REMOVE EXISTING ELECTRICAL SYSTEM S W HICH ARE M ADE SUPERFLUOUS W HEN NEW SYSTEM S ARE INSTALLED INCLUDING ALL ASSOCIATED W IRING AND DEVICES. PROVIDE BLANK STAINLESS STEEL COVERPLATES PROPERLY SIZED FOR EXISTING BACKBOX AND W ALL OPENING FOR ALL RECESSED W ALL MOUNTED DEVICES REM OVED. ALL
ABANDON RACEW AY, CONDUIT AND BOXES SHALL BE REM OVED.
U. REFER TO SPECIFICATION SECTION 01 00 00 GENERAL REQUIREM ENTS FOR STATEM ENT OF BID ITEM (S) AND
DEDUCTIVE ALTERNATES.
V. CONTRACTOR IS REQUIRED TO PROVIDE FLOOR AND W ALL PROTECTION (AS NEEDED) AND REPLACE ANY DAMAGED CEILING TILES W ITH NEW . RETURN AREA BACK TO ORIGINAL CONDITIONS UPON COM PLETION OF
W ORK.
W . THE CONTRACTOR IS RESPONSIBLE FOR REM OVING EXISTING CEILING TILE AND GRID UP TO THE NEAREST TILE AS REQUIRED IN ORDER TO INSTALL NEW CABLE, CABLE M ANAGEMENT, JUNCTION BOXES, ANTENNA, OUTLETS, ETC.
CEILING TILE W ILL BE CAREFULLY REMOVED AND STORED ON SITE OUT OF THE IM M EDIATE CONSTRUCTION AREA.
STORAGE AREA TO BE COORDINATED W ITH THE COR. AT THE END OF THE W ORK DAY ALL TILE TEMPORARILY REMOVED TO ACCOMODATE W ORK W ILL BE RE-INSTALLED UNLESS APPROVED OTHERW ISE BY THE COR. AT THE BEGINNING OF W ORK IN EACH CORRIDOR THE CONTRACTOR W ILL DOCUYM ENT ALONG W ITH THE COR THE CONDITION OF THE EXISTING CEILING TILE AND GRID, NOTING THOSE AREAS THAT BEGIN THE PROJECT AS DAMAGED, STAINED, M NISSING, ETC. ANY ADDITIONAL TILE NOT IDENTIFIED INITIALLY THAT ARE SUBSEQUENTLY DAMAGED, LOST, OR ALTERED BY THE CONTRACTOR W ILL BE REPLACED ALONG W ITH ANY AFFECTED GRID BY
THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNM ENT.
X. REFER TO PLANS FOR AREAS W HICH REQUIRE ADDITIONAL RESTRICTIONS ON LABOR HOURS AND PROCEEDURES
(3RD SHIFT, STERILE CORRIDOR, ETC.).
GENERAL NOTES
NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT
TO MODIFICATIONS ON OTHER DRAW INGS.
ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT
NECESSARILY BE USED ON THIS PROJECT.
ABBREVIATIONS
AAP - AREA ALARM PANEL - M EDICAL GAS
CC - ACCESS
ADJ - ADJUSTABLE
AF - ARC FAULT CIRCUIT INTERUPTER
AFCI - ARC FAULT CIRCUIT INTERUPTER
AFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEM
AFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEM
ALT - ALTERNATE
AP - ACCESS PANEL
APPROX - APPROXIM ATE
ARCH - ARCHITECT OR ARCHITECTURAL
ASSY - ASSEM BLY
ATS - AUTOM ATIC TRANSFER SW ITCH
BLDG - BUILDING
BOE - BOTTOM OF EQUIPM ENT
BOT - BOTTOM
BTW N - BETW EEN
CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CKT - CIRCUIT
CLG - CEILING
CMU - CONCRETE M ASONRY UNIT
CONN - CONNECT OR CONNECTION
CONTR - CONTRACTOR
CORR - CORRIDOR
CTR - CENTER
D - DEPTH
DET - DETAIL
DIA - DIAMETER
DIM - DIM ENSION
DIV - DIVISION
DN - DOW N
DW G - DRAW ING
EA - EACH
EC - ELECTRICAL CONTRACTOR (DIVISION 26)
EJ - EXPANSION JOINT
ELEC - ELECTRICAL
ELEV - ELEVATION OR ELEVATOR
EM - EMERGENCY
EQ - EQUAL
EQS - EQUIPMENT SUPPLIER
EQUIP - EQUIPM ENT
EX/R - EXISTING DEVICE TO BE REM OVED, CLEANED,
STORED, AND RELOCATED UNDER NEW W ORK PHASE.
ETR - EXISTING TO REMAIN
EW C - ELECTRIC W ATER COOLER
EX - EXISTING
EXP - EXPANSION
EXT - EXTERIOR
FCE - FIRE CONTROL EQUIPMENT
FF - FINISHED FLOOR ELEVATION
FLR - FLOOR
FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)
FT - FEET
FTG - FOOTING
GC - GENERAL CONTRACTOR
GF - GROUND FAULT CIRCUIT INTERRUPTER
GFCI - GROUND FAULT CIRCUIT INTERRUPTER OR
GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GFFT - GROUND FAULT FEED THRU
HC - HVAC CONTRACTOR (DIVISION 23)
HP - HORSE POW ER OR HIGH POINT
HVAC - HEATING, VENTILATING, AND AIR CONDITIONING
ID - INSIDE DIAMETER
IN - INCHES
KEC - KITCHEN EQUIPM ENT CONTRACTOR
L - LENGTH
LBS - POUNDS
M AP - MASTER ALARM PANEL (M EDICAL GAS)
M AX - MAXIMUM
M EZZ - M EZZANINE
M FR - MANUFACTURER
M H - M ANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEM
M IN - M INIMUM OR M INUTE
M ISC - M ISCELLANEOUS
M TD - MOUNTED
M TG - MOUNTING
NIC - NOT IN CONTRACT
NOM - NOM INAL
NTS - NOT TO SCALE
OD - OUTSIDE DIAM ETER
OFCI - OW NER FURNISHED CONTRACTOR INSTALLED
OFOI - OW NER FURNISHED OW NER INSTALLED
PC - PLUMBING CONTRACTOR (DIVISION 22)
PLBG - PLUMBING
RAD - RADIUS
REC - RECESSED
REQD - REQUIRED
RI - ROUGH-IN
S - SURFACE MOUNTED
SC - SECURITY CONTRACTOR
SCH - SCHEDULE
SHT - SHEET
SMS - SECURITY M ANAGEMENT SYSTEM
SPEC - SPECIFICATIONS
SQ - SQUARE
SS - STAINLESS STEEL
STD - STANDARD
STRUC - STRUCTURAL OR STRUCTURE
SUC - SITE UTILITY CONTRACTOR
TC - TECHNOLOGY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .