Supply: Variable Frequency Drives Federal contract opportunity
Solicitation number
36C24818Q0566
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24818Q0566 Attachment Two SON Purchase and replace VFD.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Supply: Variable Frequency Drives, newest first.
File Type Posted
36C24818Q0566-00002002.pdf PDF
36C24818Q0566-00002001.pdf PDF
36C24818Q0566-00002000.docx DOCX document
36C24818Q0566-00001000.docx DOCX document
36C24818Q0566-001.pdf PDF
36C24818Q0566-003.pdf PDF
36C24818Q0566-000.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Need: Variable Frequency Drive’s (VFD) Solicitation 36C24818Q0566

Our James A. Haley Veteran Hospital located at 13000 Bruce B Downs Blvd Tampa FL 33612 has a need for equipment and installation of VFD’s (47 VFD’s in total) throughout the facility per the list below. The hospital currently uses Johnson controls BACnet to control VFD’s. The entire system is built around the Yaskawa VFD.

Salient characteristics (Brand or equal):

• Must be compatible with existing Johnson controls BACnet system

• The foot print (size and shape) of the VFD needs to be consistent, reliable and easy to work with at the hospital due to space limitations.

• Drives must have room to work inside with less space on the outside.

• Drives use contactors which are easy to replace if they go bad.

• All the interior parts are off the shelf except for the inverter which will have to be purchased from the manufacturer.

• Most of the internal components are plug and play.

• VFD come with an already built-in Johnson Controls BACnet, Metasys (N2) program that makes the VFD simply plug and play into the system.

• All VFD’s must be new in box and without defect. Any defective equipment will be returned to the vendor for replacement at vendor’s expense.

• Contractor must provide manufacturer(s) warranty on all provided equipment.

ITEMS NEEDED:

Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 1Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 2Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 3Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 5Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 7.5Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 10Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 15Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 20Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 25Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 30Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 40Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 50Hp Drive AC, P1000 Series, Bypass, 480V, NEMA 1, 60Hp

SERVICES TO BE PROVIDED: INSTALLATION: All work will be performed during the normal VA business hours (8:00 a.m. - 5:00 p.m.) Monday through Friday, except Federal holidays, unless otherwise specified. Contractor may work outside normal business hours by arrangement with the COR: Hector Morales Hector.Morales@va.gov (813) 972-2000 x4958 if such services are provided without additional charge to the Government.

TEN (10) HOLIDAYS OBSERVED BY THE FEDERAL GOVERNMENT ARE AS FOLLOWS:

New Year’s Day January 1 Martin Luther King Day 3rd Monday in January President’s Day 3rd Monday in February Memorial Day Last Monday in May Independence Day July 4th Labor Day 1st Monday in September Columbus Day 2nd Monday in October Veterans Day November 11 Thanksgiving Last Thursday in November Christmas December 25