09.22C09.22C
RE: R.C.P.
09.29A
M
IN
09 51 00.A6
GYP. SOFFIT
RE: RCP
ACT
RE: RCP
09.22G
09.29A
/2
RCP
PER PER RCP PER RCP PER RCP PER RCP
V A
R
IE
S
MECH DUCT RE:
MECH
P 1000 AND 1001 SERIES
EXPOSED HANGER.
COORDINATE LOCATION
WITH EQUIP. MFGR.
SUPPORT RAILS BY EQUIP. MFGR.
(N.I.C.). COORDINATE
LOCATION OF SUPPORT FRAMING
WITH EQUIP. MFGR.
PROVIDE A UNISTRUT SYSTEM
CAPABLE OF CARRYING A
MOVING LOAD PER VENDORS
DRAWINGS
P 5000 SERIES UNISTRUT SYSTEM
@ 26" OC
RE: STRUCTURE
RCP
REF REF RCP REF RCP
V A
R
IE
S
RE: STRUCTURE
CEILING AS
SCHEDULED
P 1000 AND 1001 SERIES
EXPOSED HANGER.
COORDINATE LOCATION WITH
EQUIP. MFGR.
SUPPORT RAILS BY EQUIP. MFGR.
(N.I.C.). COORDINATE
LOCATION OF SUPPORT FRAMING
WITH EQUIP. MFGR.PROVIDE A UNISTRUT SYSTEM
CAPABLE OF CARRYING A MOVING
LOAD PER VENDORS DRAWINGS
P 5000 SERIES
UNISTRUT SYSTEM @
26" OC
09 51 00.A6
06.10C 10.21B
06.10C
09.29A
SUPENDED GYP CEILING
10.21B
GYP.
RE: RCP
ACT
RE: RCP
RE: RCP
09.51A
09.29A
09.22C09.22C
09.29A
09.29A
09.22C
05.12C
09.22C
10.22C
05.12B
09.29A
07.21C EXTEND GYP. BOARD AND
INSULATION TO DECK.
MAINTAIN STC RATING.
RE: STRUCTURE
ACT
RE: RCP
ACT
RE: RCP
09 51 00.A6
RADIUS GYP SOFFIT
GYP SOFFIT
10'-6" AFF
SUSPENDED GYP
11'-6" AFF (11'-0" AT SIM)
CONTROL JOINT
S
IM
09.29C
ACT
10'-0" AFF 09 51
00.A6 09.54C
SUSPENDED GYP CEILING
10'-6" AFF
09.22C
09.22G
09.22C 09.29A 09.22C09.22C 09.29A 09.22C
RE: R.C.P.
R .C
.P
P E
R
09.22C 09.29A
09.51A
M
IN
R .C
.P
P E
R
09.29A
GYP. CEILING
RE: RCP
GYP. SOFFIT
RE: RCP
ACT
RE: RCP
GYP. @ SIM
09.29A
GYP
RE: RCP
ACT
RE: RCP
09.22C
09.29A
09 51 00.A6
09.54C
RE: R.C.P.
09.22G
M
IN
09.29A09.29A GYP
RE: RCP
FRAME PER GLAZING
SYSTEM TYPE
TYP
6" INSIDE FACE OF
STUD WALL
LINE OF GYP BEYOND
12.24
09 51 00.A6
06.16C
09.22B
M
IN6
IF ALTERNATE IS
ACCEPTED, INSTALL
GYPSUM BOARD
SOFFIT
09.22C
1' - 0"
ACT
RE: RCP
09.29A
ACT
RE: RCP 09 51
00.A6 09.54C
09.22C
09.22G
GYP
RE: RCP
M
IN6
09.29A
09.29A
09 51 00.A6 09.22C
09.29A 09.22C09.22C 09.29A 09.22C
09.51A
M
IN
R .C
.P
P E
R
ACT
RE: RCP
GYP. SOFFIT
RE: RCP
ACT
RE: RCP
GYP. @ SIM
M
IN
R .C
.P
P E
R
09.51A 09.29A
RE: RCP
GENERAL NOTES:
A. REFER TO FINISH LEGEND AND FINISH
SCHEDULE FOR ROOM CEILING FINISHES
B. ACOUSTICAL CEILING TILES, GRID, &
LIGHTS TO BE CENTERED IN ROOM, U.N.O.
C. ALL CEILINGS TO BE 9'-0" AFF, U.N.O.
D. REFER TO DETAILS FOR ADDITIONAL
CONDITIONS AND CEILING HEIGHT
INFORMATION.
E. REFER TO ELECTRICAL SHEETS FOR
DETAILED INFORMATION ON LIGHT
FIXTURES.
F. REFER TO MECHANICAL SHEETS FOR
DETAILED INFORMATION ON DIFFUSERS.
G. COORDINATE ALL FLOURESENT PENDENT
MOUNTED LIGHT FIXTURES IN AREAS
WTH EXPOSED STRUCTURE WITH
EQUIPMENT
H. COORDINATE ALL CEILING MOUNTED
EQUIPMENT WITH CASEWORK BELOW.
PROFESSIONAL SEAL
C O
P Y
R
IG
H T
C
B
Y H
O E
F E
R W
Y S
O C
K I
A R
C H
IT
E
C T
S L
L C
Drawn:Checked:
Location:
Date:
Project Title:
Dwg. of
Drawing Number:
Project Number:
Building Number:
Approved: Project Director
Drawing Title:
ARCHITECT/ENGINEERS:CONSULTANTS:
A
B
C
D
E
F
986543 7 o n e an d o n e h al f in ch es o n e fo o t th re e in ch es o n e fo o t
A
B o n e in ch o n e fo o t
C o n e h al f in ch o n e fo o t
E
D th re e q u ar te rs i n ch o n e fo o t o n e q u ar te r in ch o n e fo o t
F
VA FORM 08-6231
o n e ei g h th i n ch o n e fo o t th re e ei g h th s in ch o n e fo o t
Department of Veterans Affairs
Office of Construction and Facilities Management
Project Status:8 /1
/2
:3
:4
A
M
CEILING DETAILS MONTGOMERY HEALTH CARE CENTER
08/16/2013
24321
CHANTILLY PARKWAY
MONTGOMERY, AL 36117
DD2 SUBMITTAL
A6.31
MATERIAL KEYNOTES
05.12B STEEL BEAM
05.12C STEEL CHANNEL
06.10C FIRE-RETARDANT-TREATED WOOD
BLOCKING CONTINUOUS
06.16C 3/4-INCH
FIRE-RETARDANT-TREATED
PLYWOOD SHEATHING
07.21C 3 1/2-INCH BATT INSULATION
09 51 00.A6
09.22B 2 1/2-INCH METAL STUDS @
16-INCHES O.C.
09.22C 3 5/8-INCH METAL STUDS @
16-INCHES O.C.
09.22G METAL STUD BRACING @
32-INCHES O.C.
09.29A 5/8-INCH TYPE X GYPSUM BOARD
09.29C 1/2-INCH CEILING TYPE GYPSUM
BOARD
09.51A ACOUSTICAL PANEL CEILING W/
EXPOSED GRID
09.54C METAL EDGE TRIM
10.21B CUBICLE CURTAIN AND TRACK
10.22C OPERABLE PARTITION
12.24 ROLLER WINDOW SHADE
NO. Description Date
3/4" = 1'-0"C9 WALL @ GYP SOFFIT - LAY-IN CLG
1/2" = 1'-0"C3 UNISTRUT @ MECH DUCT
1/2" = 1'-0"C6 UNISTRUT
3/4" = 1'-0"E1 TYP RCP DETAIL @ CURTAIN TRACK
3/4" = 1'-0"E4 OPERABLE PARTITION HEAD
3/4" = 1'-0"E7 GYP BULKHEAD DETAIL
3/4" = 1'-0"E9 GYP BULKHEAD DETAIL
3/4" = 1'-0"F1 GYP - GYP SOFFIT - ACT
3/4" = 1'-0"F3 GYP - GYP BULKHEAD - ACT
3/4" = 1'-0"F5 ClNG DTL @ WINDOW HEAD - CONFERENCE
ROOM ALTERNATE
3/4" = 1'-0"F7 ACT - HEADER - ACT
3/4" = 1'-0"F9 ACT - GYP SOFFIT - ACT