36C24719Q0871-0003013.pdf

PDF 168 KB Posted

Attached to
Patient Ceiling Lifts Federal contract opportunity
Solicitation number
36C24719Q0871
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7

About this file

36C24719Q0871 0003 129-h20 (13).pdf

View the file

Other files for this federal contract opportunity

Other files attached to Patient Ceiling Lifts, newest first.
File Type Posted
36C24719Q0871-0005000.docx DOCX document
36C24719Q0871-0003014.pdf PDF
36C24719Q0871-0003008.pdf PDF
36C24719Q0871-0003006.pdf PDF
36C24719Q0871-0003005.pdf PDF
36C24719Q0871-0003012.pdf PDF
36C24719Q0871-0003009.pdf PDF
36C24719Q0871-0003010.pdf PDF
36C24719Q0871-0003004.pdf PDF
36C24719Q0871-0003000.docx DOCX document
36C24719Q0871-0003007.pdf PDF
36C24719Q0871-0003015.pdf PDF
36C24719Q0871-0003003.pdf PDF
36C24719Q0871-0003001.pdf PDF
36C24719Q0871-0003002.pdf PDF
36C24719Q0871-0003011.pdf PDF
36C24719Q0871-0004007.pdf PDF
36C24719Q0871-0004004.pdf PDF
36C24719Q0871-0004000.docx DOCX document
36C24719Q0871-0004001.pdf PDF
36C24719Q0871-0004005.pdf PDF
36C24719Q0871-0004008.pdf PDF
36C24719Q0871-0004006.pdf PDF
36C24719Q0871-0004002.pdf PDF
36C24719Q0871-0004003.pdf PDF
36C24719Q0871-0004009.pdf PDF
36C24719Q0871-0002007.pdf PDF
36C24719Q0871-0002002.pdf PDF
36C24719Q0871-0002000.docx DOCX document
36C24719Q0871-0002001.pdf PDF
36C24719Q0871-0002003.pdf PDF
36C24719Q0871-0002004.pdf PDF
36C24719Q0871-0002006.pdf PDF
36C24719Q0871-0002005.pdf PDF
36C24719Q0871-0001000.docx DOCX document
36C24719Q0871-001.docx DOCX document
36C24719Q0871-000.docx DOCX document
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TO E.F.-1B

FROM GROUND FL.

6x24 EXH.

FROM FIRST FL.

TO E.F.-3B

14x12 EXH.

14x12

E.F.-3BE.F.-1B

EXHAUST FANS

IN PLENUM ABOVE

V.F.-2

12x24

12x24

FLOOR

FROM FIRST

12x18 EXH.

FLOOR

FROM GROUND

14" Ø EXH.

x2

12x22 RET.

FROM FIRST FL.

FROM FIRST FL.

20x12 RET.

14x16

14x1614x16

14x12 EXH.

TO E.F.-3A

FROM FIRST FL.

6x24 EXH.

FROM GROUND FL.

TO E.F.-1A

EXHAUST FANS

E.F.-3A 16x24

V.F.-1

E.F.-1A

IN PLENUM ABOVE

TO E.F.-1C

TO E.F.-3C

IN PLENUM ABOVE EXHAUST FANS

E.F.-1C

V.F.-3

14x12 E.F.-3C

14x12

14x12

FROM FIRST FL.

14x12 EXH. FROM GROUND FL.

6x24 EXH. 46x16 RETURN

FROM FIRST FL.

26x26

24x34 x6

26x66

TO MECH RM.

26x66 DN.UP FROM

18x12 EXH.

18x12 EXH.

UP FROM GROUND

ONE BELOW

ONE ABOVE AND

(2) 12x18 EXH. DUCT

12x18

V.F.-4

680.090

129-H20

VA MEDICAL CENTER TUSKEGEE, ALABAMA

RKSCBS129

HOME CARE UNIT

120 BED NURSINGATTIC PLAN

TUSKEGEE, ALABAMA

MEDICAL CENTER

VETERANS ADMINISTRATION

Architects and Engineers

Montgomery, Alabama 36111 P.O. Drawer 11006 3047 Carter Hill Road

Sherlock, Smith & Adams, Inc.

th re e in ch es o ne f oo t on e an d on e-ha lf in ch es o ne f oo t on e in ch o ne f oo t th re e-qu ar te rs i nc h o ne f oo t on e-ha lf in ch o ne f oo t th re e-ei gh ts i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t on e ei gt h in ch o ne f oo t

Revisions Date

Drawing Title Project Title

Approved Project Director Building Number

Location

VA FORM 08-6231A, MAR 1984 U.S.GOVERNMENT PRINTING OFFICE:1984-440-467

F E

D

4 5 6 7 8 9

987654321

C B

A A B

C D

E F

Of fic e of Fa cil itie s

Checked Drawn

Dwg. Of

DRAWING NO.

Project No.

Date

28 SEPT. 1994

NO. 16179

PROFESSIONAL

RE

G I S T E RE D

E

N G I N E E

RROBERT L . YO

UN

G

A L

A BA MA

24X12 RETURN

FROM FIRST FL.

24x6

PROVIDE F.D. @

ATTIC PENETRATION PROVIDE F.D. @

ATTIC PENETRATION

D 129-H20 129-H27

16X14 TO

FIRST FL.

FLOOR

D 129-H20 129-H27

9-

H2

9-

H2 0 D

9-

H2

9-

H2 0D

PROVIDE F.D. @

ATTIC PENETRATIONPROVIDE F.D. @

ATTIC PENETRATION

ATTIC PENETRATION

PROVIDE F.D. @

PROVIDE F.D. @

ATTIC PENETRATION

PROVIDE F.D. @

ATTIC PENETRATION

PROVIDE F.D. @

ATTIC PENETRATION

PROVIDE F.D. @

ATTIC PENETRATION

PROVIDE F.D. @

ATTIC PENETRATION

PROVIDE F.D. @

ATTIC PENETRATION

PROVIDE F.D. @

ATTIC PENETRATION

2 EACH 32x10

FROM BELOW

VF-7

NOTES:

SEE SPECIFICATIONS FOR

INSULATION THICKNESS.

STRUCTURAL DRAWINGS.

STEEL FOR HANGER SUPPORT WHERE NECESSARY. SEE

SUPPORT MECHANICAL EQUIPMENT! PROVIDE SUPPLEMENTAL

TRUSSES ONLY. HAT CHANNELS BETWEEN TRUSSES WILL NOT

NOTE TO CONTRACTOR: FASTEN HANGER SUPPORTS TO ATTIC

12x18

E.F.-2E.F.-2

MATCHLINEMATCHLINE

MATCHLINE

VA

LLE

YVALLEY

HIP

GIRDER TRUSS

HIP

GIR

DE

R

TR

US

S

RIDGE

GIRDER TRUSS

HIP

GIR

DE

R

TR

US

S

HIP

HIP

VALLEY

STUD WALL

TR

US

S

ST

UD

WA

LL

TR

US

S

ST

UD

WA

LL

STUDWALL

GIR

DE

R

TR

US

S

HIP

GIR

DE

R

TR

US

S

VA

LLE

Y

RI

DG

E

HIP

VALLEY

RI

DG

E

HIP

GIRDER TRUSS

GIRDER TRUSS

TR

US

S

TR

US

S

ST

UD

WA

LL

HIP

GIRDER TRUSS

VALLEY

GIRDER TRUSS

VA

LLE

Y

HIP

GIR

DE

R

TR

US

S

HIP

GIR

DE

R

TR

US

S

RIDGE

TR

US

S GI

RD

ER

T

RU

SS

HIP

G

IRD

ER

RIDGE

HIP

GIR

DE

R

TR

US

S

HIP

VA

LLE

Y

TYP.

STUDWALL

GIR

DE

R

TR

US

S

HIP

VALLEY

HIP

GIRDER TRUSS

GIRDER TRUSS

RIDGE

RI

DG

E

HIP

GIRDER TRUSS

HIP

GIR

DE

R

TR

US

S

RIDGE

GIRDER TRUSS

HIP

GIR

DE

R

TR

US

S

HIP

VA

LLE

Y

VALLEY

KEY PLAN

PLAN SCALE: 1/8" = 1'-0"

A

B

32x10

VF-6

18x18 EXHAUST DUCTS CONN.

TO 4'-8 x 3'-6 x 8"-0"

DEEP PLENUM. BLANK

UNUSED PORTION.

C C A D

5.

2\ 9-

H

.D W G a t

:1 9:

b y

JO

N A

TH

O N J O

IN

ER

Information contained on record drawings is per as -built information provided to the A\E on drawings provided by the Contractor. The A\E has performed no independent review to confirm the accuracy or completeness of the information provided by the Contractor.