36C24719Q0871-0003015.pdf
PDF 296 KB Posted
- Attached to
- Patient Ceiling Lifts Federal contract opportunity
- Solicitation number
- 36C24719Q0871
About this file
36C24719Q0871 0003 129-h22 (15).pdf
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
th re e in ch es o ne f oo t on e an d on e-ha lf in ch es o ne f oo t on e in ch o ne f oo t th re e-qu ar te rs i nc h o ne f oo t on e-ha lf in ch o ne f oo t th re e-ei gh ts i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t on e ei gt h in ch o ne f oo t
Revisions Date
Drawing Title Project Title
Approved Project Director Building Number
Location
VA FORM 08-6231A, MAR 1984 U.S.GOVERNMENT PRINTING OFFICE:1984-440-467
F E
D
4 5 6 7 8 9
987654321
C B
A A B
C D
E F
Off ice o f F ac ilit ies
Checked Drawn
Dwg. Of
DRAWING NO.
Project No.
Date
28 SEPT. 1994
NO. 16179
PROFESSIONAL
RE
G I S T E RE D
E
N G I N E E
RROBERT L . YO
UN
G
A L
A BA MA
680.090
129-H22
VA MEDICAL CENTER TUSKEGEE, ALABAMA
RKSCBS129
HOME CARE UNIT
120 BED NURSING
PIPING PLAN - BLK. "B"
HVAC GROUND FLOOR
TUSKEGEE, ALABAMA
MEDICAL CENTER
VETERANS ADMINISTRATION
Architects and Engineers
Montgomery, Alabama 36111 P.O. Drawer 11006 3047 Carter Hill Road
Sherlock, Smith & Adams, Inc.
1P1M
1Q 1S
1R 1T
1A
1C
HWH HWH HWH
HW
H
HW
HR
HW
H
HW
HR
HWH
HWHHWHR HWH HWH
HW
HHW
HR
HW
H
HW
HR
HW
H
HW
HR
HW
HR
HW
HR
HW
H
HW
HR
3" HWH &
HWHR UP
C
A
B
KEY PLAN
PLAN SCALE: 1/8" = 1'-0"
C-1
C-3
1D
T
TT
T T
T T
T
T
T
T
T
T
T
T T
T
T
T
T
T
T
T
1B
FC-3
1N
T
T
H J
K D.W.
L M
N P
3 54 76 98 1110
H K
(ALTERNATE "L")
GARDEN PAVILION
CHR
1" CH
1-1/2"
1"1-1/4"
1"3/4"1-1/2"1"
1-1/2"
1-1/4"
1"
3/4"
3/4" (TYP.) 1-1/2"
2" 1-1/2"
2"
1-1/2"
1"
1-1/4"
1-1/4"
1-1/2"
1"
2 1/2"
2" 1 1/2"
3/4"
3"
2 1/2"
3/4"
3/4"
4"
T/S
W/C
W/C
W/C
ROOM
TWO-BED
TWO-BED
W/C
T/S
T/S
TWO-BED
TWO-BED
TWO-BED
TOIL.
EQUIPMENT
LAUNDRY
SUPPLY
PATIENT
ROOM
TWO-BED
ROOM
ROOM
TWO-BED
STAIR
STORAGE
LARGE
TWO-BED
ROOM
LARGE
TWO-BED
ROOM
W/C T/S
TWO-BED
ROOM
TWO-BED
ROOM
W/C T/S
W/C T/S
TWO-BED
ROOM
CORRIDOR W/C T/S
ROOM
TWO-BED
ONE-BED
ROOM
W/C T/S
BATH
STOR.
CONG.
ONE-BED
ROOM
UTILITY
CLEAN
W/C T/S
ROOM
TWO-BED ROOM
ELEC.
STAFF
CONSULT.
QUIET
WARD
ONE-BED
ROOM
ROOM
ROOM
ROOM
TWO-BED
TWO-BED
ELEV.
EQUIPMENT
OFFICE
NURSE
W/C T/S
ROOM
ONE-BED
W/C
KITCHEN
NOURISH.
TOILETS
LOCKERS/
MENS
SOILED
UTILITY
CORR. LOUNGE
LLT
STAFF
MED.
TOILETS
WOMENS
LOCKERS/
W/C T/S
ONE-BED
ROOM
COMM.HOUSEKEEPING
NURSES'
STATION
AIDS CLOSET
EXAM
ALCOVE
STORAGE
HEAD
W/C T/S
TWO-BED
ROOM
TWO-BED
ROOM
ROOM
W/C T/S
CORRIDOR
WORKER
ROOM
TWO-BED
SOCIAL
OFFICE ROOM
TWO-BED
ROOM
ROOM
TWO-BED
W/C T/S
W/C T/S
ROOM
TWO-BED
T/S
ROOM
T/S W/C
CORRIDOR
ROOM
TWO-BED
TWO-BED
ROOM
ONE-BED
W/C
TWO-BED
ROOM
TWO-BED
ROOM
T/S W/C
GARDEN
PAVILION
TWO-BED
ROOM
HWHR
HWHR
HWHR
HWHR
HWHR
HWHR
HWHR HWHR HWHR
HWHR
NO.4
141A
143A
139A
GB-140
16CG- 137A
145A
136A
CG-9
148A
100A
100B
102 103A
10CG-
CG-12
CG-13
104A
105 106
105A
CG-
113 112
111A
107A
NO.2
109A
14CG-
129A
119A
121A
127A
125A
123A
NO.3
GB-
GB-
GB-
GB-
GB- GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB- GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-GB-GB-GB-
GB-
GB-
GB- GB-
GB- GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB-
GB- GB-
GB-GB-
GB- GB-
GB- GB-
GB-
HWHR
HWH
M D
1E1G
1H
1J
1K1L
1V
1X1Y
1Z
1BB
1F
1W
1AA
1U
T
Ô"
MATCH LINE
MATCH LINE
C C A D
5.
2\ 9-
H
.D W G a t :2 8:
b y
JO
N A
TH
O N J O
IN
ER
Information contained on record drawings is per as -built information provided to the A\E on drawings provided by the Contractor. The A\E has performed no independent review to confirm the accuracy or completeness of the information provided by the Contractor.
SHERLOCK, SMITH, & ADAMS, INC.
RECORD DRAWINGS
By: 3/21/00Date:
Model
File details come from the government source that posted it.