CHECKLIST FOR INSPECTION OF ELECTRIC ELEVATORS
GENERAL NOTES:
(a) See ASME A17.2-2004 for detailed inspection information on each item number.
(bl OK = meets requirements; NG = insert number to identify comment on back of this
Checklist; NA = not applicable.
Address: O Routine inspection and test O Periodic inspection and test
-·-·---- O Acceptance inspection and test
!D No: Code Edition:
Inspected by:
O Passenger Rated load: Signature: Date:
D Freight class Speed: OEI No: Certifying organization:
OK NG NA OK NG NA
ELEVATOR - INSIDE OF CAR 2.21 Belt- or chain-drive machine D D D
1.1 Door reopening device D D D 2.22 Motor generator 0 0 0
1.2 Stop switches 0 D D 2.23 Absorption of regenerated power D D D
1.3 Operating control devices D 0 D 2.24 AC drives from a DC source D D D
1.4 Sills and car floor 0 0 0 2.25 Traction sheaves D D D
1.5 Car lighting and receptacles D D D 2.26 Secondary and deflector sheaves 0 0 0
1.6 Car emergency signal 0 0 D 2.27 Rope fastenings D D D
1.7 Car door or gate 0 D 0 2.28 Terminal stopping devices D D 0
1.8 Door closing force 0 0 0 2.29 Car and counterweight safeties 0 0 :J
1.9 Power closing of doors or gates 0 0 D 2.39 Low oil protection 0 D 0
1.10 Power opening of doors or gates [] D D 2.40 Inspection control D D D
1. 11 Car vision panels and glass car doors D D D 2.41 Maintenance records D D D
1.12 Car enclosure [] 0 0 2.42 Static control 0 0 0
1.13 Emergency exit 0 D 0
1.14 Ventilation D 0 D 3 ELEVATOR - TOP OF CAR
1.15 Signs and operating device symbols D 0 D 3.1 Top-of·car stop switch D D D
Rated load, platform area, and data plate D D
3.2 Car top light and outlet D D D 1.16 D 3.3 Top-of-car operating device D D D
1.17 Standby power operation D D D 3.4 Top-of-car clearance, refuge space, and D 0 D
1.18 Restricted opening of car or hoistway D CJ D standard railing doors 3.5 Normal terminal stopping devices 0 D 0
1.19 Car ride 0 0 D
3.6 Final and emergency terminal stopping D D
LJ
2 ELEVATOR - MACHINE ROOM devices
2. 1 Access to machine space D 0 D 3.7 Car leveling and anticreep devices D D D
2.2 Headroom 0 0 0 3.8 Top emergency exit D [] D
2.3 Lighting and receptacles D 0 0 3.9 Floor and emergency identification 0 D 0
2.4 Machine space 0 D 0 numbering
2.5 Housekeeping 0 0 0 3.10 Hoistway construction D D n
2.6 Ventilation D D D 3.11 Hoistway smoke control D D D
2.7 Fire extinguisher D 0 0 3.12 Pipes, wiring, and ducts D 0 D
2.8 Pipes, wiring, and ducts 0 0 0 3.13 Windows, projections, recesses, and 0 0 0
2.9 Guarding of exposed auxiliary equipment 0 0 D setbacks
2.10 Numbering of elevators, machines, and LJ 0 D 3.14 Hoistway clearances 0 0 : ... J disconnect switches 3.15 Multiple hoistways D [J D
2.11 Disconnecting means and control 0 D D 3.16 Traveling cables and junction boxes D D D
2.12 Controller wiring, fuses, grounding, etc. D 0 0 3.17 Door and gate equipment D D D
2.13 Governor, overspeed switch, and seal D CJ D 3.18 Car frame and stiles D D D
2.14 Code data plate [J 0 [] 3.19 Guide rails fastening and equipment D D 0
2.15 Static control 0 tJ 0 3.20 Governor rope D D L
2.16 Overhead beam and 'fastenings 0 0 D 3.21 Governor releasing carrier D
D c_.;
2.17 Drive machine brake D 0 D 3.22 Wire rope fastening and hitch plate D D D
2.18 Traction drive machines 0 0 0 3.23 Suspension rope 0 0 D
2.19 Gears, bearings, and flexible couplings [] tJ n 3.24 Top counterweight clearance 0 0 0
2.20 Winding drum machine and slack cable 0 0 [] 3.25 Car, overhead, and deflector sheaves [] r·""!
LJ D
device
I
CHECKLIST FOR INS~ECTION OF ELECTRIC ELEVATORS (Back)
OK NG NA OK NG NA
3.26 Broken rope, chain, or tape switch 0 0 [] 5.2 Bottom clearance, runby, and minimum 0 0 0
3.27 Crosshead data plate and rope data tags 0 0 0 refuge space
3.28 Counterweight and counterweight buffer 0 0 0 5.3 Final and emergency terminal stopping 0 0 0
3.29 Counterweight safeties 0 0 0 devices
3.33 Compensating ropes and chains 0 0 0
5.4 Normal terminal stopping devices 0 D 0
4 ELEVATOR- OUTSIDE HOISTWAY 5.5 Traveling cables D 0 0
4.1 Car platform guard [J 0 0 5.6 Governor-rope tension devices 0 0 D
4.2 Hoistway doors 0 0 0 5.7 Car Frame and platform D D 0
4.3 Vision panels [] 0 0 5.8 Car safeties and guiding members - 0 0 0 4.4 Hoistway door locking devices 0 0 0
4.5 Access to hoistway 0 0 0 including roped-hydraulic elevators installed under A 17.1b-1989 and later
4.6 Power closing of hoistway doors [] 0 0 editions
4.7 Sequence operation 0 0 0 5.9 Buffers and emergency terminal speed 0 0 0
4.8 Hoistway enclosure 0 0 [J limiting devices
4.9 Elevator Parking devices 0 0 0 5.10 Compensating chains, ropes, and sheaves 0 D D
4.10 Emergency doors in blind hoistways 0 [] 0
6 ELEVATOR - FIREFIGHTERS' SERVICE
4.11 Separate counf.erweight hoistway 0 D 0 6.1 D A17.1b-1973 through A17.1b-1980 [] 0 0 4.12 Standby power selection switch 0 0 0 6.2 O A17.1-1981 through A17.1b-1983 0 [] 0 4.13 Inspection control 0 0 0 6.3 O A17.1-1984 through A17.1a-1988 and 0 [] 0
A17.3
5 ELEVATOR- PIT
6.4 [] A17.1b-1989 through A17.1d-2000 0 0 0 5.1 Pit access, lighting, stop switch, and 0 0 0 condition
Comments: