CHECKLIST FOR INSPECTION OF HYDRAULIC ELEVATORS
GENERAL NOTES:
(a) See ASME A 17.2-2004 for detailed inspection information on each item number.
(b) OK == meets requirements; NG == insert number to identify comment on back of this
Checklist; NA "" not applicable.
Address: O Routine inspection and test O Periodic inspection and test O Acceptance inspection and test
ID No: Code Edition:
Inspected by:
Pr mt
[J Passenger Rated load: Signature: Date:
O Freight class Speed: OEI No: Certifying organization:
OK NG NA OK NG NA
1 ELEVATOR- INSIDE OF CAR 2.36 Hydraulic cylinders 0 0 0
1.1 Door reopening device D 0 D 2.37 Pressure switch D 0 0
1.2 Stop switches 0 0 D 2.38 Roped water hydraulic elevators 0 0 0
1.3 Operating control devices 0 0 0 2.39 Low oil protection 0 D D
1.4 Sills and car floor 0 0 D 2.40 Inspection control 0 0 0
1.5 Car lighting and receptacles 0 0 D 2.41 Maintenance records 0 0 0
1.6 Car emergency signal 0 0 0 2.42 Static control 0 0 0
1.7 Car door or gate 0 0 0
1.8 Door closing force 0 0 0 3 ELEVATOR - TOP OF CAR
1.9 Power closing of doors or gates 0 0 0 3.1 Top-of-car stop switch 0 0 0
1.10 Power opening of doors or gates D D D 3.2 Car top light and outlet 0 0 0
1.11 Car vision panels and glass car doors D
3.3 Top-of-car operating device D 0 D
D D 3.4 Top-of-car clearance, refuge space, and D D D
1.12 Car enclosure D D D standard railing
1.13 Emergency exit 0 [] 0 3.5 Normal terminal stopping devices D D D
1.14 Ventilation D D 0
1.15 Signs and operating device symbols D 0 0 3.6 Final and emergency terminal stopping D 0 D devices 'i.16 Rated load, platform area, and data plate 0 [J D 3.7 Car leveling and anticreep devices D D [..I
1.17 Standby power operation D D D 3.8 Top emergency exit 0 0 0
1.18 Restricted opening of car or hoistway 0 D D 3.9 Floor and emergency identification 0 0 0 doors numbering
1.19 Car ride 0 D 0 3.10 Hoistway construction D D 0
2 ELEVATOR - MACHINE ROOM 3.11 Hoistway smoke control 0 D D
2.1 Access to machine space D 0 D 3.12 Pipes, wiring, and ducts D D 0
2.2 Headroom D D 0 3.13 Windows, projections, recesses, and 0 0 0
2.3 Lighting and receptacles 0 D D setbacks
2.4 Machine space 0 D 0 3.14 Hoistway clearances D 0 c
2.5 Housekeeping [] D 0 3.15 Multiple hoistways D D D
2.6 Ventilation D D D 3.16 Traveling cables and junction boxes D 0 D
2.7 Fire extinguisher D D 0 3.17 Door and gate equipment D 0 0
2.8 Pipes, wiring, and ducts D 0 0 3.18 Car frame and stiles D 0 , ' ,__;
2.9 Guarding of exposed auxiliary equipment 0 0 D 3.19 Guide rails fastenings and equipment 0 D D
2.10 Numbering of elevators, machines, and D 0 D 3.20 Governor rope D 0 0 disconnect switches
3.21 Governor releasing carrier D D D
2.11 Disconnecting means and control D 0 D 3.22 Wire rope fastening and hitch plate 0 0 c
2.12 Controller wiring, fuses, grounding, etc. D [.l D 3.23 Suspension rope D 0 D
2.13 Governor, overspeed switch, and seal D D D 3.27 Crosshead data plate and rope data tags D D [J
2.14 Code data plate 0 D u 3.28 Counterweight and counterweight buffer D LJ D
2.30 Hydraulic power unit 0 [J D 3.29 Counterweight safeties D 0 D
2.31 Relief valves D 0 D 3.30 Speed test D D D
2.32 Control valve D 0 D 3.31 Slack rope device - roped-hydraulic D 0 0
2.33 Tanks D 0 0 elevators installed under A17.1b-1989
2.34 Flexible hydraulic hose and fitting 0 0 D and later editions assemblies 3.32 Traveling sheave - roped-hydraulic D 0 D
2.35 Supply line and shutoff valve D 0 D elevators installed under A17.1b-1989 and later editions
CHECKUST FOR INSPECTION OF HYDRAULIC ELEVATORS (Back)
OK NG NA OK NG NA
4 ELEVATOR - OUTSIDE HOISTWAY 5.5 Traveling cables CJ D D
4.1 Car platform guard D [J D 5.6 Governor-rope tension device 0 0 0
4.2 Hoistway doors 0 [] 0 5.7 Car frame and platform 0 0 0
4.3 Vision panels [] [] D 5.8 Car safeties and guiding members - 0 [] 0
4.4 Hoistway door locking devices [] [.J 0 including roped-hydraulic elevators
4.5 ,.:..ccess to hoistway D D 0 installed under A17.1b-1989 and later
4.6 Power closing of hoistway doors CJ [J []
editions
4.7 Sequence operation D D [] 5.11 Plunger and cylinder D D D
4.8 Hoistway enclosure D D D 5.12 Car buffer D 0 D
4.9 Elevator parking device [J n [J 5.13 Guiding members D D 0 L..>
4.10 Emergency doors in blind holstways LJ Ci [] 5.14 Supply piping 0 D n
4.12 Standby power selection switch 0 LI D 6 ELEVATOR- FIREFIGHTERS' SERVICE
4.13 Inspection control 0 [] 0 6.1 LJ A17.1b-1973through A17.1b-1980 D 0 0
ELEVATOR - P!l' S.2 O A17.1-1981 through A17.1b-1983 0 D 0 5
6.3 O A17.1-1984 through A17.1a-1988 and D D D 6.1 Pit access, lighting, stop switch, and u [J, [] A17.3 condition
6.4 O A17.1b-1989through A17.1d-2000 0 D D ,. ,., Bottom clearance, rnnby, and minimum r1 D 0 ,).£.
refuge space
5.4 Normal terminal stopping devices D D []