36C24618R0176-00001004.pdf

PDF 2 MB Posted

Attached to
Project 590-14-112, SCI Crawlspace Emergent Structural Repairs Federal contract opportunity
Solicitation number
36C24618R0176
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

36C24618R0176 00001 Amendment 00001 - Attachment C - Asbestos Sampling Report.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Project 590-14-112, SCI Crawlspace Emergent Structural Repairs, newest first.
File Type Posted
36C24618C0056-000.docx DOCX document
36C24618R0176-00003000.docx DOCX document
36C24618R0176-00003001.pdf PDF
36C24618R0176-00002001.pdf PDF
36C24618R0176-00002000.docx DOCX document
36C24618R0176-00001005.pdf PDF
36C24618R0176-00001003.pdf PDF
36C24618R0176-00001001.pdf PDF
36C24618R0176-00001002.pdf PDF
36C24618R0176-00001000.docx DOCX document
36C24618R0176-002.docx DOCX document
36C24618R0176-006.docx DOCX document
36C24618R0176-003.pdf PDF
36C24618R0176-001.docx DOCX document
36C24618R0176-005.pdf PDF
36C24618R0176-004.pdf PDF
36C24618R0176-007.docx DOCX document
36C24618R0176-000.docx DOCX document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Terracon Consultants, Inc. 2401 Brentwood Road, Suite 107 Rale igh, North Carol ina 27604

P [919] 873 2211 F [919] 873 9555 terracon.com

June 24, 2016

RDC/John Poe Architects 116 East Third Street Dayton, Ohio 45402

Attn: Mr. Tom Hesse, AIA

Re: Limited Asbestos Sampling Report Hampton Veteran’s Affairs Medical Center

100 Emancipation Drive Hampton, Virginia

Terracon Project No.: 70167296

Dear Mr. Hesse:

The purpose of this report is to present the results of the limited asbestos survey performed on

June 15, 2016 for RDC/John Poe Architects (Client) at the above referenced area located on the campus of Hampton Veteran’s Affairs Medical Center in Hampton, Virginia. This survey was conducted in general accordance with Terracon Proposal No. P70167296 dated June 7, 2016.

We understand that these services were requested due to the planned suspect wall material disturbance and proposed work in the crawl space where it has been brought into question about potential asbestos presence/contamination. Our survey activities were limited to the specific areas as detailed to Terracon by site representatives.

Asbestos was identified during the course of our limited survey. Please refer to the attached report for details.

Terracon appreciates the opportunity to provide this service to RDC/John Poe Architects. If you have any questions regarding this report, please contact the undersigned at 919.873.2211.

Sincerely, Terracon Consultants Inc.

For:

Michael Penny, EI Scott D. Rohlf, CIH

Project Environmental Engineer Authorized Project Reviewer

LIMITED ASBESTOS SAMPLING REPORT

Hampton Veteran’s Affairs Medical Center

100 Emancipation Drive

Hampton, Virginia

June 24, 2016

Terracon Project 70167296

Prepared For:

RDC/John Poe Architects

Dayton, Ohio

Prepared By:

Terracon Consultants, Inc.

Raleigh, North Carolina

Responsive ■ Resourceful ■ Reliable i

TABLE OF CONTENTS

Page No.

1.0 INTRODUCTION

1.1 PROJECT OBJECTIVE

2.0 BUILDING DESCRIPTION

3.0 FIELD ACTIVITIES

3.1 VISUAL ASSESSMENT

3.2 PHYSICAL ASSESSMENT

3.3 SAMPLE COLLECTION

3.4 SAMPLE ANALYSIS

4.0 REGULATORY OVERVIEW

5.0 FINDINGS AND RECOMMENDATIONS

6.0 GENERAL COMMENTS

Appendix A Asbestos Survey Sample Summary

Appendix B Identified Asbestos-Containing Materials

Appendix C Asbestos Analytical Laboratory Data

Appendix D General Crawl Space Sample Location Diagram

Responsive ■ Resourceful ■ Reliable 1

LIMITED ASBESTOS SAMPLING REPORT

HAMPTON VETERAN’S AFFAIRS MEDICAL CENTER

100 EMANCIPATION DRIVE

HAMPTON, VIRGINIA

TERRACON PROJECT NO. 70167296

1.0 INTRODUCTION

Terracon conducted asbestos sampling of client-selected areas of the crawl space and patient rooms located on the campus of Hampton Veteran’s Affairs Medical Center in Hampton, Virginia. This limited survey was conducted on June 15, 2016 by a Commonwealth of Virginia

Accredited Asbestos Building Inspectors in general accordance with Terracon Proposal No.

P70167296 dated June 7, 2016.

The select areas were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be located in voids or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in EPA regulation 40 CFR 763

(Asbestos Hazard Emergency Response Act, AHERA). Samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy.

1.1 Project Objective

We understand this limited asbestos sampling was requested due to the planned suspect wall material disturbance and proposed work in the crawl space. We understand the purpose of these services is to identify and quantify ACM present prior to renovation activities and work in the crawl space. EPA regulation 40 CFR 61, Subpart M, National Emission Standards for

Hazardous Air Pollutants (NESHAP), prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated asbestos-containing building materials be identified, classified and quantified prior to planned disturbances, renovation or demolition activities.

2.0 BUILDING DESCRIPTION

Building 137 – Eastern Unoccupied Patient Rooms

The site structure is a partially occupied medical building. However, the client provided scope of work was limited to walls located on two unoccupied wings on the east side of the building.

The walls were finished with plaster over foam insulation board. Terracon did not assess other portions of the building.

Limited Asbestos Sampling Report

Hampton Veteran’s Affairs Bldg. 137 ■ Hampton, Virginia

June 24, 2016 ■ Terracon Project No. 70167296

Responsive ■ Resourceful ■ Reliable 2

Building 137 – Crawl Space

Terracon assessed the crawl space areas below the two eastern wings of the building. This totaled approximately 4,000 square feet of dirt floor crawl space. The crawl space walls consisted of concrete. Construction debris (floor tiles, insulation, concrete, wood) was observed throughout the crawl space areas.

3.0 FIELD ACTIVITIES

The limited survey was conducted by Commonwealth of Virginia Accredited Asbestos Building

Inspectors Mr. Michael Penny and Ms. Alicia Coley (VA Accredited Asbestos Inspector

Numbers 3303004009 and 3303003481, respectively). The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, the Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.

3.1 Visual Assessment

Our survey activities began with a visual observation of the work areas to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color, texture and date of application. At the request of the Client, only select suspect wall materials were sampled, and only a select portion of the crawl space was assessed. Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect. The survey was limited to readily and safely accessible areas of the proposed renovation area.

3.2 Physical Assessment

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material, which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.3 Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. The inspectors collected bulk samples using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Building 137 – Eastern Unoccupied Patient Rooms

Eight (8) bulk samples were collected from one homogeneous area of suspect ACM from the vacant patient room walls.

Responsive ■ Resourceful ■ Reliable 3

Building 137 – Crawl Space

Terracon separated the two subject crawl space area into two 16-section grids and collected one surface soil sample from each area within those grids. Terracon collected a total of 32 samples of soil and debris from the crawl space.

A summary of suspect ACM samples collected during the survey is included as Appendix A.

3.4 Sample Analysis

Bulk samples were submitted under chain of custody to EMSL Analytical, Inc. (EMSL) of

Morrisville, North Carolina for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA methodology (40 CFR 763, Subpart F). The percentage of asbestos, where applicable, was determined by microscopic visual estimation. EMSL is accredited under the National Voluntary Laboratory Accreditation Program NVLAP

(Accreditation Number 200671-0).

4.0 REGULATORY OVERVIEW

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activity. Under NESHAP, asbestos-containing building materials are classified as either friable, Category I non-friable or Category II non-friable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Category I non-friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than

1% asbestos. Category II non-friable ACM are any materials other than Category I materials that contain more than 1% asbestos.

In the state of Virginia, the Virginia Department of Labor and Industry (DOLI) regulates asbestos abatement and removal through Virginia Occupational Safety and Health (VOSH) regulations, Environmental Protection Agency’s National Emission Standards for Hazardous

Air Pollutants (NESHAP), and enforcement of the Asbestos Notification regulations found in the Labor Laws of Virginia (§40.1-51.20). The DOLI requires that any asbestos-related activity conducted in a public building be performed by personnel accredited by the Commonwealth of Virginia Department of Professional and Occupational Regulation (DPOR).

Written notification to DOLI of renovation or demolition activities is required only if asbestos is present and the amount to be disturbed is greater than 10 linear feet or 10 square feet. If non-friable asbestos-containing material, roofing, flooring and siding materials are in good condition and when installed, encapsulated or removed do not become friable, a notification is not required. If the ACM is not in good condition or ACM removal will be conducted using mechanical means, notification is required. The asbestos abatement contractor or facility

Responsive ■ Resourceful ■ Reliable 4 owner must submit an Asbestos Notification of Demolition and Renovation form to the DOLI along with the appropriate fees within at least 20 calendar days prior to the scheduled asbestos removal activity or demolition start date by certified mail or hand delivery.

The EPA requires that no person remove more than 35 cubic feet (1 cubic meter), 160 square feet (15 square meters), or 260 linear feet (80 linear meters) of regulated asbestos-containing material without a permit issued by the EPA. Applications must be postmarked or received by the EPA at least 10 working days prior to the scheduled removal start date. The application, must be mailed to the following address:

• Asbestos Coordinator

USEPA

Region III

Mail Code 3LC62

1650 Arch St.

Philadelphia, PA 19103-2029

Virginia Occupational Safety and Health (VOSH) regulations govern workplace exposure to asbestos. The VOSH Asbestos standard requires employee exposure to airborne asbestos fibers be maintained at or below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc). The

VOSH Asbestos standard classifies construction and maintenance activities, which could disturb ACM and specifies work practices and precautions, which employers must follow when engaging in each class of regulated work. This standard also sets forth communication of hazard requirements for building owners, including requirements for posting areas of known or presumed ACM (PACM). The standard requires building owners and lessees who control the management and recordkeeping functions of a building to maintain information regarding the presence, location and quantity of ACM and PACM for the duration of ownership or lease.

The information must be transferred to successive building owners and to employers whose employees may be exposed to asbestos, including tenants who will occupy areas containing

ACM or PACM.

5.0 FINDINGS AND RECOMMENDATIONS

Based on the results of laboratory analysis, asbestos was identified in 3 of the 32 samples of the following material:

Soil (crawl space)

Appendix D includes a general location diagram of areas identified to contain asbestos.

Employees working in these areas and surrounding areas should be at least OSHA Class III workers and should wear proper respiratory and clothing protection.

Responsive ■ Resourceful ■ Reliable 5

Laboratory analytical reports are included in Appendix C. It is possible that additional suspect material be located in concealed areas such as wall cavities or in depths of soil beyond this scope. If additional suspect materials is found during renovation activities, they should be assumed to contain asbestos until laboratory analysis can confirm or deny their asbestos content.

6.0 GENERAL COMMENTS

This limited asbestos sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building.

The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by RDC/John Poe Architects for specific application to their project as discussed. This report is not a bidding document.

Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information, which may have been used in the preparation of this report. No warranty, expressed or implied is made.

APPENDIX A

ASBESTOS SURVEY SAMPLE SUMMARY

HA Sample No. Description Sample Location Lab Results 1 HVA-1 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-2 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-3 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-4 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-5 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-6 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-7 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

1 HVA-8 Plaster with black felt paper and gray mastic on blue foam Wall adjacent to new building on CMU None Detected

2 A1 Soil and debris North-East Wing Crawl Space None Detected

3 A2 Soil and debris North-East Wing Crawl Space None Detected

4 A3 Soil and debris North-East Wing Crawl Space None Detected

5 A4 Soil and debris North-East Wing Crawl Space None Detected

6 B1 Soil and debris North-East Wing Crawl Space None Detected

7 B2 Soil and debris North-East Wing Crawl Space None Detected

8 B3 Soil and debris North-East Wing Crawl Space None Detected

9 B4 Soil and debris North-East Wing Crawl Space None Detected

10 C1 Soil and debris North-East Wing Crawl Space None Detected

11 C2 Soil and debris North-East Wing Crawl Space None Detected

12 C3 Soil and debris North-East Wing Crawl Space None Detected

13 C4 Soil and debris North-East Wing Crawl Space Chrysotile

14 D1 Soil and debris North-East Wing Crawl Space None Detected

15 D2 Soil and debris North-East Wing Crawl Space None Detected

16 D3 Soil and debris North-East Wing Crawl Space Chrysotile

17 D4 Soil and debris North-East Wing Crawl Space None Detected

18 E1 Soil and debris South-East Wing Crawl Space None Detected

19 E2 Soil and debris South-East Wing Crawl Space Chrysotile

20 E3 Soil and debris South-East Wing Crawl Space None Detected

21 E4 Soil and debris South-East Wing Crawl Space None Detected

22 F1 Soil and debris South-East Wing Crawl Space None Detected

23 F2 Soil and debris South-East Wing Crawl Space None Detected

24 F3 Soil and debris South-East Wing Crawl Space None Detected

25 F4 Soil and debris South-East Wing Crawl Space None Detected

26 G1 Soil and debris South-East Wing Crawl Space None Detected

27 G2 Soil and debris South-East Wing Crawl Space None Detected

28 G3 Soil and debris South-East Wing Crawl Space None Detected

29 G4 Soil and debris South-East Wing Crawl Space None Detected

30 H1 Soil and debris South-East Wing Crawl Space None Detected

31 H2 Soil and debris South-East Wing Crawl Space None Detected

32 H3 Soil and debris South-East Wing Crawl Space None Detected

33 H4 Soil and debris South-East Wing Crawl Space None Detected

Results in bold indicate asbestos-containing materials.

*Analyzed by a qualitative PLM analysis; asbestos quantities are not provided

100 Emancipation Drive

Hampton, Virginia

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

Hampton Veteran Affair's Building 137

A-1

APPENDIX B

IDENTIFIED ASBESTOS-CONTAINING MATERIALS

HA

Sample

No.

Description Material Location

NESHAP

Classification

Type

Asbestos Condition

Estimated

Quantity*

13 C4 Soil and Debris North-East Wing

Crawl Space N/A Chrysotile Damaged

Approximately

100 square feet

16 D3 Soil and Debris North-East Wing

Crawl Space N/A Chrysotile Damaged

Approximately

100 square feet

19 E2 Soil and Debris South-East Wing

Crawl Space N/A Chrysotile Damaged

Approximately

100 square feet

Note: All quantities should be verified by the asbestos abatement contractor.

Appendix B

IDENTIFIED ASBESTOS-CONTAINING MATERIALS

Hampton Veteran Affair's Building 137 100 Emancipation Drive

Hampton, Virginia

B-2

APPENDIX C

ASBESTOS LABORATORY ANALYTICAL REPORT

Sample Description Appearance Result Notes

Test Report: Qualitative asbestos analysis of soils using the EPA 600/R-93/116 method

Attn: Michael Penny Terracon Consultants, Inc.

2401 Brentwood Road Suite 107 Raleigh, NC 27604

Received: 06/16/16 1:00 PM

70167296

Fax: (919) 873-9555 Phone: (919) 873-2211

Project:

6/20/2016Analysis Date:

6/15/2016Collected:

EMSL Analytical, Inc.

2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560 Phone/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com raleighlab@emsl.com

291603935 CustomerID: TITA51 CustomerPO:

ProjectID:

EMSL Order:

A1 291603935-0009

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

A2 291603935-0010

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

A3 291603935-0011

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

A4 291603935-0012

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

B1 291603935-0013

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

B2 291603935-0014

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

B3 291603935-0015

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

B4 291603935-0016

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

C1 291603935-0017

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

Billy Barnes, Asbestos Lab Manager or other approved signatory

1Test Report PLMQualw/Types-7.21.0 Printed: 6/20/2016 3:59:12 PM

Analyst(s)

Soil is a problem matrix due to its inherent heterogeneity and there is a likelihood for false negatives with this analysis. EMSL recommends more specialized methodologies such as the EPA 600/R-93/116 with milling preparation. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Morrisville, NC

Billy Barnes (5) Joshua Moorman (8)

Roxsee Stover (19)

Initial report from 06/20/2016 14:16:43 http://www.EMSL.com mailto:raleighlab@emsl.com

Attn: Michael Penny Terracon Consultants, Inc.

2401 Brentwood Road Suite 107 Raleigh, NC 27604

Received: 06/16/16 1:00 PM

70167296

Fax: (919) 873-9555 Phone: (919) 873-2211

Project:

6/20/2016Analysis Date:

6/15/2016Collected:

EMSL Analytical, Inc.

2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560 Phone/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com raleighlab@emsl.com

291603935 CustomerID: TITA51 CustomerPO:

ProjectID:

EMSL Order:

C2 291603935-0018

North Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

C3 291603935-0019

North Crawl Space, Soil/Debris

Brown/Gray None Detected Fibrous Homogeneous

C4 291603935-0020

North Crawl Space, Soil/Debris

Gray/White Non-Fibrous Homogeneous

Chrysotile

D1 291603935-0021

North Crawl Space, Soil/Debris

Brown/Black None Detected Fibrous Homogeneous

D2 291603935-0022

North Crawl Space, Soil/Debris

Various None Detected Fibrous Homogeneous

D3 291603935-0023

North Crawl Space, Soil/Debris

Various Fibrous Homogeneous

Chrysotile

D4 291603935-0024

North Crawl Space, Soil/Debris

Brown/Tan/Black None Detected Fibrous Homogeneous

E1 291603935-0025

South Crawl Space, Soil/Debris

Various None Detected Fibrous Homogeneous

E2 291603935-0026

South Crawl Space, Soil/Debris

Brown Fibrous Homogeneous

Chrysotile

Billy Barnes, Asbestos Lab Manager or other approved signatory

2Test Report PLMQualw/Types-7.21.0 Printed: 6/20/2016 3:59:12 PM

Analyst(s)

Soil is a problem matrix due to its inherent heterogeneity and there is a likelihood for false negatives with this analysis. EMSL recommends more specialized methodologies such as the EPA 600/R-93/116 with milling preparation. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Morrisville, NC

Billy Barnes (5) Joshua Moorman (8)

Roxsee Stover (19)

Initial report from 06/20/2016 14:16:43

Attn: Michael Penny Terracon Consultants, Inc.

2401 Brentwood Road Suite 107 Raleigh, NC 27604

Received: 06/16/16 1:00 PM

70167296

Fax: (919) 873-9555 Phone: (919) 873-2211

Project:

6/20/2016Analysis Date:

6/15/2016Collected:

EMSL Analytical, Inc.

2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560 Phone/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com raleighlab@emsl.com

291603935 CustomerID: TITA51 CustomerPO:

ProjectID:

EMSL Order:

E3 291603935-0027

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

E4 291603935-0028

South Crawl Space, Soil/Debris

Brown/Tan/Black None Detected Fibrous Homogeneous

F1 291603935-0029

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

F2 291603935-0030

South Crawl Space, Soil/Debris

Brown/Tan None Detected Fibrous Homogeneous

F3 291603935-0031

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

F4 291603935-0032

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

G1 291603935-0033

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

G2 291603935-0034

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

G3 291603935-0035

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

Billy Barnes, Asbestos Lab Manager or other approved signatory

3Test Report PLMQualw/Types-7.21.0 Printed: 6/20/2016 3:59:12 PM

Analyst(s)

Soil is a problem matrix due to its inherent heterogeneity and there is a likelihood for false negatives with this analysis. EMSL recommends more specialized methodologies such as the EPA 600/R-93/116 with milling preparation. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Morrisville, NC

Billy Barnes (5) Joshua Moorman (8)

Roxsee Stover (19)

Initial report from 06/20/2016 14:16:43

Attn: Michael Penny Terracon Consultants, Inc.

2401 Brentwood Road Suite 107 Raleigh, NC 27604

Received: 06/16/16 1:00 PM

70167296

Fax: (919) 873-9555 Phone: (919) 873-2211

Project:

6/20/2016Analysis Date:

6/15/2016Collected:

EMSL Analytical, Inc.

2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560 Phone/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com raleighlab@emsl.com

291603935 CustomerID: TITA51 CustomerPO:

ProjectID:

EMSL Order:

G4 291603935-0036

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

H1 291603935-0037

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

H2 291603935-0038

South Crawl Space, Soil/Debris

Brown/Tan None Detected Fibrous Homogeneous

H3 291603935-0039

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

H4 291603935-0040

South Crawl Space, Soil/Debris

Brown None Detected Fibrous Homogeneous

Vermiculite and Soil are known problem matrices and negative results cannot be guaranteed. Additional analysis such as CARB 435 milling prep or ASTM Draft Soil Sieving is recommended for proper quantification of asbestos in vermiculite and soil.

Billy Barnes, Asbestos Lab Manager or other approved signatory

4Test Report PLMQualw/Types-7.21.0 Printed: 6/20/2016 3:59:12 PM

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

Soil is a problem matrix due to its inherent heterogeneity and there is a likelihood for false negatives with this analysis. EMSL recommends more specialized methodologies such as the EPA 600/R-93/116 with milling preparation. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted.

Samples analyzed by EMSL Analytical, Inc. Morrisville, NC

Billy Barnes (5) Joshua Moorman (8)

Roxsee Stover (19)

Initial report from 06/20/2016 14:16:43

EMSL Analytical, Inc.

2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560

Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com

291603935EMSL Order:

Customer ID: TITA51

Customer PO:

Project ID:

Attention: Phone:Michael Penny (919) 873-2211

Fax:Terracon Consultants, Inc. (919) 873-9555

Received Date:2401 Brentwood Road 06/16/2016 1:00 PM

Analysis Date:Suite 107 06/17/2016

Collected Date:Raleigh, NC 27604 06/15/2016

Project: 70167296

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light

Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

HVA-1-Skim Coat

291603935-0001

None DetectedNon-fibrous (Other)98%Cellulose2%White

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-1-Base Coat

291603935-0001A

None DetectedNon-fibrous (Other)98%Cellulose

Glass

2%

<1%

Gray

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-1-Felt Paper

291603935-0001B

None DetectedNon-fibrous (Other)76%Cellulose

Synthetic

12%

12%

Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-1-Mastic

291603935-0001C

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

Inseparable foam.

HVA-2-Skim Coat

291603935-0002

None DetectedNon-fibrous (Other)98%Cellulose2%White

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-2-Base Coat

291603935-0002A

None DetectedNon-fibrous (Other)100%Cellulose

Glass

<1%

<1%

Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-2-Felt Paper

291603935-0002B

None DetectedNon-fibrous (Other)78%Cellulose

Synthetic

10%

12%

Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-2-Mastic

291603935-0002C

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

Inseparable foam.

HVA-3-Skim Coat

291603935-0003

None DetectedNon-fibrous (Other)100%Cellulose<1%White

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

Initial report from: 06/20/2016 14:16:43

Page 1 of 4PLM - 1.69 Printed: 6/20/2016 3:59 PM

Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com

291603935EMSL Order:

Customer ID: TITA51

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light

Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

HVA-3-Base Coat

291603935-0003A

None DetectedNon-fibrous (Other)100%Cellulose<1%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-3-Felt Paper

291603935-0003B

None DetectedNon-fibrous (Other)76%Cellulose

Synthetic

12%

12%

Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-3-Mastic

291603935-0003C

None DetectedNon-fibrous (Other)100%Cellulose<1%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

Inseparable foam.

HVA-4-Skim Coat

291603935-0004

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-4-Base Coat

291603935-0004A

None DetectedNon-fibrous (Other)100%Glass<1%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-4-Felt Paper

291603935-0004B

None DetectedNon-fibrous (Other)80%Cellulose

Synthetic

10%

10%

Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-4-Mastic

291603935-0004C

None DetectedNon-fibrous (Other)100%Cellulose<1%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-5-Skim Coat

291603935-0005

None DetectedNon-fibrous (Other)98%Cellulose2%White

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-5-Base Coat

291603935-0005A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-5-Felt Paper

291603935-0005B

None DetectedNon-fibrous (Other)76%Cellulose

Synthetic

12%

12%

Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-5-Mastic

291603935-0005C

None DetectedNon-fibrous (Other)100%Cellulose<1%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

Page 2 of 4PLM - 1.69 Printed: 6/20/2016 3:59 PM

Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com

291603935EMSL Order:

Customer ID: TITA51

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light

Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

HVA-6-Skim Coat

291603935-0006

None DetectedNon-fibrous (Other)98%Cellulose2%White

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-6-Base Coat

291603935-0006A

None DetectedNon-fibrous (Other)96%Cellulose

Glass

2%

2%

Gray

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-6-Felt Paper

291603935-0006B

None DetectedNon-fibrous (Other)40%Cellulose60%Brown/Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-6-Mastic

291603935-0006C

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-7-Skim Coat

291603935-0007

None DetectedNon-fibrous (Other)95%Cellulose5%White

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-7-Base Coat

291603935-0007A

None DetectedNon-fibrous (Other)98%Cellulose2%Gray

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-7-Felt Paper

291603935-0007B

None DetectedNon-fibrous (Other)40%Cellulose60%Brown/Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-7-Mastic

291603935-0007C

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-8-Skim Coat

291603935-0008

None DetectedNon-fibrous (Other)98%Cellulose2%White

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-8-Base Coat

291603935-0008A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-8-Felt Paper

291603935-0008B

None DetectedNon-fibrous (Other)40%Cellulose60%Brown/Black

Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

HVA-8-Mastic

291603935-0008C

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Wall Adjacent to New

Bldg on CMU -

Plaster w/ Black Felt

Paper & Gray Mastic on Blue Foam

Page 3 of 4PLM - 1.69 Printed: 6/20/2016 3:59 PM

Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com

291603935EMSL Order:

Customer ID: TITA51

Customer PO:

Project ID:

Analyst(s)

Olivia Bradley (20)

Roxsee Stover (12)

Billy Barnes, Asbestos Lab Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296

Page 4 of 4PLM - 1.69 Printed: 6/20/2016 3:59 PM

OrderID: 291603935

APPENDIX D

GENERAL CRAWL SPACE SAMPLE LOCAITON DIAGRAM

UP

UP

GENERAL NOTE

A. REFER TO SHEET 137-P001 FOR DRAWING INDEX, LEGEND AND NOTES.

P418

P418

P413

FD1

FD2

P107

FD2

P418

P413

FD1

P107

CO

-2

VR

P418

CO

P413

FD1

P418

FD2

P107

2-

P413

FD1

FD2

P107

P418

P418

P413

FD1

FD2

P107

VR

VR

P413

P107

P418

FD1

VR

FD2

CO CO COCO

P107

FD2

P418

P413FD1

VR

P418

CO

FD1

VR

P413

CO

VR

P418

P413

P418

FD1

FD2

P506

P418

P413

P418

P413

P418

VR

FD1

FD1

FD2

P418

P506

P506 FD2

-2

P418

FD2

P506

P413

VR

FD1

FD1

FD2

P418

P506

P506

2-

FD2

EXISTING SCI PHASE1

ELECTRICAL MANHOLE

EXISTING SCI PHASE1

ELECTRICAL HANDHOLE

EXISTING SCI PHASE1

ELECTRICAL MANHOLE

CO

P413

P418

EXISTING

DUCTBANK

EXISTING

DUCTBANK

P413

CO

0.75"

2"

3"

0.75"

2"

3"

0.75"

2"

3"

CO

CO

1.25" 2"

0.75"

1.5" 2"

CO

CO

10.75"

-2" DCW

1 -0.5" DHWR

1.5" DHW

2"

11"

1"

10.75"

2"

1 -0.5" DHWR

1.5" DHW

1 -2" DCW

1.25"

2"

FD1

CO

P418

P418

P418

P413 P505

P413

FD1

P418

FD2

P107

P418

CO

P418

P529

P531

P529

P107

FD2

P418

P413

FD1

VR

P413

P418

P506

FD2

FD1

P418

FD2

P506

P413

P418

CO

2-

P418

FD1

P413

FD2

P107

CO

P418

4" DS BOOT

BY P.C.

4" DS BOOT

BY P.C.

4" DS BOOT

BY P.C.

ST

S T

S T

S T

4"

4"

4"

4"

4"

4"

ST

15"

ST

ST

S T

S T

AD1

AD1

AD1

AD1

AD1

4" 4"

4"

4"

4"

4"

4"

4"

COTRAP

1 1

P524

CO

M V

M A

O

M V

M A

O

M V

M A

O

0.75"

0.75" DHW &

1.5" DCW TO

1ST FLOOR

ABOVE

1.5"

CO

CO

TO EXISTING

WATER HEATERS

0.75"8

0.75"

CO

CO

CO

CO

VR

0.75"

1.25" 2"

0.75"

P418

2"

0.75"

0.75"

FD4

FD4

0.75"

2" 0.75"

1.5"

0.75"

1.5"

1.5" 0.75" 0.5"EXISTING 1.5" DCW

& 0.75" DHW RISERS

1 1.5" 0.75"

EXISTING 0.75"

DCW & DHW

RISERS

0.5"

P418

P505

VR

-2

14 14

14 14

14 14

14 14

13 13

1 15

1 15

CO

12 12

VR

VR

VR

VR

SS VR

VR

FD1

P103 P418

FD1

VR

VR

-2 2-

VR

VR

SS

MA

MV

O2

MA

MV

O2

M V

M A

O

6" DS

ST

S T

S T

S T

1 -6" DS

1 -6" DS

4" DS

STCO

ST

6" DS

CONNECT WHERE

EXISTING PIPING

DROPS THRU GRADE

CONNECT WHERE

EXISTING PIPING

DROPS THRU GRADE

S T

ST

TEST-Y

& CO

PIPING DROPS

THRU GRADE

A A

Drawing Title

Approved: Project Director Location

Building Number

Project Title

Checked Drawn Drawing Number on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

F E

D C

B A

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

A R C H I T E C T SJ O H N P O E

937 461 3290 PHONE

937 461 0260 FAX

jpa@johnpoe.com

ARCHITECT/ENGINEERS:CONSULTANTS:

RDC /

524 FERNWOOD DRIVE

ALTAMONTE SPRINGS, FLORIDA

32701

Heapy Project No.: 2011-04008

Date

Project No.

Dwg. of

RDC/JPA Project No.

Hampton VA, VAMC Renovate / Expand SCI, Phase II, 590-911

PARTIAL PIPE BASEMENT PLAN -

AREA A - NEW WORK

137-P101

DPBRLT

Hampton, Va.

09/14/2012

11004.00

590-911

NOTES:

N Scale: 1/8" = 1'-0"1

PARTIAL PIPE BASEMENT - AREA A - NEW

WORK

N.T.S.Scale:

KEYPLAN

1 EXISTING TO REMAIN.

2 EXTEND 2" DCW, 1" DHW & 0.75" DHWR SUPPLY RISERS UP TO ABOVE

FIRST FLOOR CEILING TO SERVE NEW ADDITION AND RENOVATED AREA AS

INDICATED ON SHEET 137-P103.

3 EXTEND 2" DCW, 1.25" DHW & 0.75" DHWR SUPPLY RISERS UP TO ABOVE

FIRST FLOOR CEILING TO SERVE NEW ADDITION AND RENOVATED AREA AS

INDICATED ON SHEET 137-P103.

4 EXTEND 2" DCW & 1 DHW SUPPLY RISERS UP TO ABOVE FIRST FLOOR CEILING

TO SERVE NEW ADDITION AND RENOVATED AREA AS INDICATED ON SHEET 137-P103.

5 EXTEND 0.75" DHWR PIPING UP TO ABOVE FIRST FLOOR CEILING TO SERVE

RENOVATED AREA AS INDICATED ON SHEET 137-P103.

6 EXTEND 2" DCW, 1.25" DHW & 0.75" DHWR SUPPLY RISERS UP TO ABOVE

FIRST FLOOR CEILING TO SERVE NEW ADDITION AND RENOVATED AREA AS

INDICATED ON SHEET 137-P103.

7 PROVIDE 0.5 GPM FLOW CONTROLLER ON DHWR WITH ISOLATION VALVES.

8 PROVIDE 0.25 GPM FLOW CONTROLLER ON DHWR WITH ISOLATION VALVES.

9 EXTEND 0.5" DCW & 0.5" DHW SUPPLY RISERS UP TO FIRST FLOOR TO SERVE P418

FIXTURE AS INDICATED ON SHEET 137-P103.

10 EXTEND 1.5" DCW & 0.75" DHW SUPPLY RISERS UP TO FIRST FLOOR TO SERVE P505

FIXTURE AS INDICATED ON SHEET 137-P103.

11 UNDER DEDUCT ALTERNATE 5 DELETE ALL WORK ASSOCIATED WITH RESIDENT/WARMING

KITCHEN.

12 UNDER DEDUCT ALTERNATE 4 ALL STORM SYSTEM WORK IN COURTYARD(S) SHALL REMAIN.

13 UNDER DEDUCT ALTERNATE 6 DELETE ALL WORK SHOWN IN THIS AREA. REFER TO DEDUCT

ALTERNATE PLAN(S) ON SHEET 137-P801.

14 UNDER DEDUCT ALTERNATE 6 & 7 REVISE PLUMBING FIXTURE LAYOUT AS REQUIRED TO

MATCH ARCHITECTURAL PLANS. REFER TO DEDUCT ALTERNATE PLAN(S) ON SHEET 137-P801.

15 EXISTING 0.75" DCW EXTENDING UP TO FIRST FLOOR ABOVE TO SERVE EXISTING EXTERIOR

WALL HYDRANT TO REMAIN.

16 EXISTING 0.75" MA & 0.75" O2 MEDICAL GAS RISERS EXTENDING UP TO SERVE FIRST

FLOOR TO REMAIN. EXTEND NEW 1.5" MV PIPING UP TO ABOVE FIRST FLOOR CEILING TO

SERVE FIRST FLOOR AS INDICATED ON SHEET 137-P105.

Revisions Date mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Callout D3 mdpenny Callout C4 mdpenny Text Box General sample location diagram

Highlighted area indicates area that reported asbestos in soil sample.

Samples were analyzed utilizing qualitative PLM analysis.

GENERAL NOTE

A. REFER TO SHEET 137-P001 FOR DRAWING INDEX, LEGEND AND NOTES.

P413

FD1

FD2

P107

FD2

P418

P413

FD1

P107

CO

-2

VR

CO

CO

FD1

FD1

VR

P413

P413

FD2

P107

FD2

P107

P4182-

P418

CO

P413

CO

P413

VR

CO

FD1

P418

FD2

P107

P418

CO

P418

P107

FD2

P418

FD1

VR

P413

P107

FD2

P418

P418

CO

VR

FD1

P413

P418

P107

P413

FD1

FD2

VR

P418

P418

CO

FD1

P418

FD2

P506

P418

P413CO

CO

VR

P418

P413

P418

FD1

FD2P506

VR

P413

EXISTING SCI PHASE1

ELECTRICAL MANHOLE

EXISTING

DUCTBANK

P418

FD2 P506

P413

P418

P413

P418

P413

P418

P413

P418

FD1

FD1

FD2

FD2

P418

P506

P506

-2

VR

FD1

FD1

FD2

FD2

P418

P506

P506

-2

VR

P413

P418

0.75"

2"

3"

CO

FD2

P506

P418

CO

P413

P418

P418

P413P107

P413

FD2

FD2

VR

P418 P107

FD2

P418

FD1

P413

VR

CO

10.75" -

CO

CO

CO

P418

CO

10.75" -

FD1

- 1.5" DCW

1" DHW

0.5" DHWR

1"

1.5"

2"

1 - 2" DCW

1.25" DHW

0.75"

2"

1.25"

0.75"

2" 1.25"

0.75"

2" 1.25"

1.25"

2.5"

1 - 1"

CO

1.5"

CO

1.5" 1"

0.75"

2"1.25"

0.75"

1.5"1"

CO

FD1

VR

FD1

P418

P418

P418

P418

P529

P808

P529

ST ST ST ST

ST

ST

S T

S T

4"

4"

4"

4"

4"

CO

4" DS BOOT

BY P.C.

4" DS BOOT

BY P.C.

M V

O

M V

O

M V

O

M A

M A

M A

AD1

CO

AD1

AD1

TRAP

4"

4"

4"

4"

4"

AD1

CO

AD1

4"

4"

TRAP

ST

8"8"6"6" 6"

6"

INV. @

722'-7"

EXISTING

DUCTBANK

EXISTING

DUCTBANK

VR

P418

P413

P107

FD2

CO

P413

P529

P531

4"

FD4

FD4

0.75"

0.5"

REC.

PUMP-

0.75"

0.75"

O2

MV

MA

P418

12 12

VR

VR

VR

VR

VR

VR

CO

P530

VR

VR

VR

MV

MA

O2

P808

S T

S T

STST ST

CO

B B

Drawing Title

Approved: Project Director Location

Building Number

Project Title

Checked Drawn Drawing Number on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

F E

D C

B A

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

A R C H I T E C T SJ O H N P O E

937 461 3290 PHONE

937 461 0260 FAX

jpa@johnpoe.com

ARCHITECT/ENGINEERS:CONSULTANTS:

RDC /

524 FERNWOOD DRIVE

ALTAMONTE SPRINGS, FLORIDA

32701

Heapy Project No.: 2011-04008

Date

Project No.

Dwg. of

RDC/JPA Project No.

Hampton VA, VAMC Renovate / Expand SCI, Phase II, 590-911

PARTIAL PIPE BASEMENT PLAN -

AREA B - NEW WORK

137-P102

DPBRLT

Hampton, Va.

09/14/2012

11004.00

590-911

NOTES:

N Scale: 1/8" = 1'-0"1

PARTIAL PIPE BASEMENT PLAN - AREA B

- NEW WORK

N.T.S.Scale:

KEYPLAN

1 EXISTING TO REMAIN.

2 EXTEND 2" DCW, 1.25" DHW & 0.75" DHWR SUPPLY RISERS UP TO

ABOVE FIRST FLOOR CEILING TO SERVE RENOVATED AREA AND NEW

ADDITION AS INDICATED ON SHEET 137-P104.

3 NEW 0.75" DHWR FROM FIRST FLOOR ABOVE. PIPING CONTINUED

ON SHEET 137-P104

4 EXTEND NEW 1.5" DCW, 1" DHW & 0.75" DHWR SUPPLY RISERS UP TO

ABOVE FIRST FLOOR CEILING TO SERVE RENOVATED AREA AS

INDICATED ON SHEET 137-P104.

5 P.C. SHALL EXTEND 8" STORM PIPING 5'-0" FROM BUILDING EXTERIOR

WALL AND STUB FOR EXTENSION BY S.U.C.

6 RE-INSTALL EXISTING RE-CIRCULATION PUMP IN NEW 0.75" RECIRCULATION

LINE.

7 PROVIDE 0.5 GPM FLOW CONTROLLER ON DHWR WITH ISOLATION VALVES.

8 PROVIDE 0.25 GPM FLOW CONTROLLER ON DHWR WITH ISOLATION VALVES.

9 PROVIDE COMBINATION BALANCING/SHUT-OFF VALVE. SET UNIT TO

MAINTAIN FLOW OF 0.5 GPM.

10 EXISTING 0.75" DCW EXTENDING UP TO FIRST FLOOR ABOVE TO SERVE

EXISTING EXTERIOR WALL HYDRANT TO REMAIN.

11 UNDER DEDUCT ALTERNATE 4 ALL STORM SYSTEM WORK IN COURTYARD(S)

SHALL REMAIN.

12 UNDER DEDUCT ALTERNATE 6 & 7 DELETE ALL WORK IN THIS AREA. REFER

TO DEDUCT ALTERNATE PLAN(S) ON SHEET 137-P801.

13 EXISTING 0.75" MA & 0.75" O2 MEDICAL GAS RISERS EXTENDING UP TO SERVE

SERVE FLOOR TO REMAIN. EXTEND NEW 1.5" MV PIPING UP TO ABOVE FIRST

FLOOR CEILING TO SERVE FIRST FLOOR AS INDICATED ON SHEET 137-P106.

Revisions Date mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Rectangle mdpenny Callout E2 mdpenny Text Box General sample location diagram

Highlighted area indicates area that reported asbestos in soil sample.

Samples were analyzed utilizing qualitative PLM analysis.

291603935_007.pdf
291603935_008.pdf
291603935_coc.pdf
2016-06-24T14:06:57-0400
Weaver, Dwight D.
2016-06-24T14:11:32-0400
Rohlf, Scott D.

File details come from the government source that posted it.