36C24424Q0643.docx

DOCX document 16 KB Posted

Attached to
6515--AngioDynamics Pro Laser This is Not a Request for Quote
Solicitation number
36C24424Q0643
Issued by

About this file

This document is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office 4 for the VA Philadelphia Healthcare System. The notice seeks information from vendors capable of providing an endovenous laser treatment system and infiltration pump for the Interventional Radiology department at the Corporal Michael J. Crescenz VA Medical Center.

The key requirements include a 1470nm wavelength laser with targeted energy of 30-50 joules/cm and maximum power of 15 watts, as well as an infiltration pump capable of up to 1,100 ml per minute. The system must have features such as easy-to-use controls, ability to track pullback, internal sensors, and real-time display of settings. Vendors must provide all equipment, accessories, installation, and project management. Optional features include a loaner program and multi-media card. The infiltration pump must be compatible with the laser treatment unit. Responses are due by May 3, 2024 at 12PM Eastern Time.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
AngioDynamics Pro Laser This is Not a Request for Quote

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
19104
SOLICITATION NUMBER*
36C24424Q0643
RESPONSE DATE/TIME/ZONE
05-03-2024 12PM EASTERN TIME, NEW YORK, USA
ARCHIVE
3 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 4 VA Philadelphia Healthcare System 3900 Woodland Avenue Philadelphia, PA 19104-4551

POINT OF CONTACT*

Contact Specialist Sherrie Thompson sherrie.thompson2@va.gov

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

VA Philadelphia Healthcare System

3900 Woodland Avenue

Philadelphia PA

POSTAL CODE
19104-4551

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

STATEMENT OF NEED

ANGIODYNAMICS PRO LASER

Description of Use:

The Corporal Michael J. Crescenz VA Medical Center is in need of (1) endovenous laser treatment system and (1) infiltration pump, which is critical for use in the Interventional Radiology section.

Objective The Corporal Michael Crescenz VA Medical Center (CMCVAMC) intends to procure an endovenous laser treatment system and (1) infiltration pump for the facility’s Interventional Radiology department. This document highlights the technical specifications and services being requested by the facility for consideration towards purchase of an endovenous laser. Vendors under this proposal shall provide all equipment and accessories, installation services, and project management support.

Minimum Technical Specifications:

The endovenous laser treatment and infiltration pump system shall meet the following minimum specifications:

· Achieves optimal vein ablation

· 1470nm wavelength laser

· Water-specific, diode laser

· Targeted energy of 30-50 joules/cm

· Maximum power of 15 watts

· Easy-to-use controls

· Ability to track pull-back through audible alarms/sounds

· Ability to program the laser for specific fiber types

· Internal sensors to monitor settings (eg. wattage, energy output)

· Aiming beam has multiple modes

· Real-time on-screen display of settings

· Foot pedal

· Pump that provides high-speed infiltration into vessels

· Infiltrates up to 1,100 ml per minute, or better

· Vibration free unit

· Tubing can be easily mounted.

· Emergency shut off.

· 110v

· Class 4 laser

· Safety glasses

· Keys

· Warning signs

· Spare fuse(s)

· Test fiber(s)

· Remote interlock connectors

· Power cord

· 3 year warranty

Optional/Value Added Features:

· Loaner program

· Multi-media card

Required Interfaces:

The infiltration pump must be compatible with the endovenous laser treatment unit.