J059--Electrical Life Study at Butler VAMC Federal contract opportunity
Solicitation number
36C24420Q0992
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

View the file

Other files for this federal contract opportunity

Other files attached to J059--Electrical Life Study at Butler VAMC, newest first.
File Type Posted
36C24420Q0992 0002_1.docx DOCX document
Attachment 1--Vendor Questions.pdf PDF
36C24420Q0992 0001_1.docx DOCX document
Final Submission Arc Flash Drawings.pdf PDF
ArcFlash-Final.pdf PDF
Attachment 02.pdf PDF
36C24420Q0992_1.docx DOCX document
Attachment 01.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Maintenance Inventory 2020

Building # Room/Location Name of Device Space Type of Device Size Setting Existing Recommended 1 CA45 AHU‐1 Disconnect MCCB 500A 1 CA45 Clinical MDP MCCB 1200A 2 B19 ATS‐EDL ATS w/Bypass 800 2 B19 ATS‐EDL Normal MCCB 800 2 B19 ATS‐ELEV ATS w/Bypass 300

2 B19 ATS‐ELEV EMERG MCCB 300

2 B19 ATS‐ELEV Normal MCCB 300 2 B19 ATS‐LS ATS w/Bypass 150

2 B19 ATS‐LS EMERG MCCB 100

2 B19 ATS‐LS Normal MCCB 100 2 B19 ATS‐MDP ATS w/Bypass 300

2 B19 ATS‐MDP EMERG MCCB 300

2 B19 ATS‐MDP Normal MCCB 300 2 B19 TX Humidifer Dry Transformer 75 Kva 2 Outside Transformer #12 Pad Mounted Transformer 4 Mech ATS‐LS ATS w/Bypass 4 Mech ATS‐M ATS w/Bypass 4 Outside Bldg 4 Load interrupet sw MV Load interrupet sw 600A 4 Outside Transformer #T3 Pad Mounted Transformer 5 MDP 5 Main Distribution Panel 800A 5 MDP 5 Main MCCB 800A 5 Outside Transformer #T4 Pad Mounted Transformer 6 Outside Dissconnect #T5 Wall Mounted Disconnect 600A 6 Outside Transformer #T5 Pad Mounted Transformer 7 106 ATS‐2 feed MCCB 500A 7 106 PP‐7 Load interrupet sw MV Load interrupet sw 600A 7 106 PP‐7 Main Breaker MCCB 600A 7 106 PP‐7 Spare MCCB 350A 7 106 PP‐7 Transformer Dry Transformer 500Kva

7 107 ATS‐2 ECB MCCB 800A

7 107 ATS‐2 Normal power Dry Transformer 300Kva 7 107 ATS‐LS Dry Transformer 30Kva

7 107 ATS‐LS ECB MCCB 100A

7 108 MV room 52‐1 Main Breaker 1A MV Vacuum Breaker 51P Delay,50TP Pickup, 50TN Pickup 2.5, 65, 25 1, 25, 20 7 108 MV room 52‐2 Main Breaker 2A MV Vacuum Breaker 51P Delay,50TP Pickup, 50TN Pickup, 51N Delay 5, 2.5, 65, 3 2.5, 1.7, 30, 2.4 7 108 MV room AT 10.1 Charger Cir 11 Battery Bank Charger 7 108 MV room BEI‐851 3A breaker control 7 108 MV room BEI‐851 3B breaker control 7 108 MV room BEI‐851 4A breaker control 7 108 MV room BEI‐851 5A breaker control 7 108 MV room BEI‐851 5B breaker control 7 108 MV room BEI‐951 1A breaker control 7 108 MV room BEI‐951 2A breaker control 7 108 MV room Feeder #1 3A MV Vacuum Breaker 7 108 MV room Feeder #2 4A MV Vacuum Breaker 7 108 MV room Feeder #3 5A MV Vacuum Breaker 7 108 MV room Feeder Bldg #18 3B MV Vacuum Breaker 7 108 MV room Feeder Bldg 30 5B MV Vacuum Breaker 7 108 MV room MV switch gear cabinet Switchgear cabinet 7 108 MV room Voltmeter 1B voltmeter 7 108 MV room Voltmeter 2B voltmeter 7 B02 ATS‐1 ATS w/Bypass 400A

Page 1 https://vaww.aams.ecms.va.gov/AAMS_Production/DAV/6‐syyyykydn‐0‐yy/Maintenance Inventory 2020

7 B02 ATS‐2 ATS w/Bypass 800A 7 B02 ATS‐2 ECB Emergency feed MCCB 800A 7 B02 ATS‐LS ATS w/Bypass 150A 7 B02 ATS‐LS Dry Transformer 30Kva

7 B02 PNL X MAIN MCCB 800A

7 B02 PNL XS'S ATS‐2 FEED MCCB

7 B02 PNL‐X's PnL A FEED MCCB 7 Outside Temp Boiler Disconect Wall Mounted Disconnect 400A 20 120 ATS‐2CC ATS w/Bypass 20 120 ATS‐2LS ATS w/Bypass 20 120 Feed to PB‐2M MCCB 1200A 20 120 MDP‐2 IQ Analyzer IQ Analyzer 20 120 MDP‐2 Main MCCB 1600A 20 120 PB‐2M Disc MCCB 1200A 20 121 Feed to PB‐1M MCCB 800A 20 121 MDP‐1 IQ Analyzer IQ Analyzer 20 121 MDP‐1 Main MCCB 1600A 20 121 PB‐1M Disc MCCB 800A 20 123 Bldg 2 Emergency Disc MCCB 800 20 123B ATS‐1CC ATS w/Bypass 400 20 123B ATS‐1LS ATS w/Bypass 225 20 Outside Transformer #14 Pad Mounted Transformer 21 Outside Transformer #T6 Pad Mounted Transformer 21 ATS‐CC ATS w/Bypass

21 ATS‐FP MCCB 400A

21 ATS‐LS ATS w/Bypass 21 Bldg 21 Main MCCB 1600A 21 Fire Pump Transfer Sw ATS w/Bypass 30 101 Bldg 30 Main Masterpact LV Power CB 4000A 30 101 CH‐1 Spare Masterpact LV Power CB 800A 30 101 CH‐2 Masterpact LV Power CB 800A 30 101 CH‐3 Masterpact LV Power CB 800A 30 101 HDP1 Masterpact LV Power CB 800A 30 101 LV Switch Gear Switchgear cabinet 30 101 MCC1 Masterpact LV Power CB 800A 30 101 MCC2 Masterpact LV Power CB 800A 30 101 Spare Future CH‐4 Masterpact LV Power CB 800A 30 101 TREQ2 Dry Transformer 30 101 TX LDP1 Dry Transformer 112.5 30 102 Disconnect ATS LS ECB 70A 30 102 Disconnect ATS‐EQ ECB 200A 30 102 EQL2 Dry Transformer 30 102 TREQ1 Dry Transformer 30 102 TRLS1 Dry Transformer 30 Gen Rm ATS‐EQ ATS w/Bypass 30 Gen Rm ATS‐LS ATS w/Bypass 30 Outside Bldg 30 Transformer #T7 Pad Mounted Transformer 31 Outside SWBD‐1 MAIN Power CB 3200A 31 Outside SWBD‐1 MDP1 MCCB 1600A 31 Outside SWBD‐1 MDP2 MCCB 1600A

31 SWBD‐1 B2‐KITCHEN MCCB

34 Generator Breaker Powerpact PJ 1200 1200a 35 Outside Bldg 35 Normal Feed Pad Mounted Disconnect

Page 2 https://vaww.aams.ecms.va.gov/AAMS_Production/DAV/6‐syyyykydn‐0‐yy/Maintenance Inventory 2020

35 Outside Fire Pump Normal Feed (150) Pad Mounted Disconnect 35 Outside Transformer #T13 Pad Mounted Transformer 35 ATS 35 ATS w/Bypass 47 Gen Room Bldg 47 Main Wall Mounted Disconnect 47 Outside Transformer #T8 Pad Mounted Transformer

99 100 ATS‐1 MCCB 800A

99 100 ATS‐2 MCCB 800A

99 100 ATS‐Clinical MCCB 800A

99 100 ATS‐EQ MCCB 800A

99 100 ATS‐LS MCCB 800A

99 100 Emergency SWBRD Main MCCB 2000A 99 100 TX Eyewash Dry Transformer 99 101A Load interrupet sw #1 MV Load interrupet sw 99 101A Load interrupet sw #2 MV Load interrupet sw 99 101A Load interrupet sw #3 MV Load interrupet sw 99 101A 52‐1 Main Breaker Magnus DS Power CB 3200A LTD, STPU, GFPU, GFD 2, 2, 0.35, 0.25 4.5, 6, 0.5, 0.5 99 101A 52‐1 Tie Breaker Magnus DS Power CB 3200A 99 101A 52‐2 Main Breaker Magnus DS Power CB 3200A LTD, STPU, INST 2, 3, 0.25 3, 4, 0.5 99 101A Feeder 2A MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 2A MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 2B MDP1 Magnus DS Power CB 800A 99 101A Feeder 2B MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, 12 99 101A Feeder 2C MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 2C MDP2 Magnus DS Power CB 800A 99 101A Feeder 2D MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 10, 8, 8 99 101A Feeder 2D MDP2 Magnus DS Power CB 800A 99 101A Feeder 3A MDP1 Magnus DS Power CB 800A 99 101A Feeder 3A MDP2 Magnus DS Power CB 800A 99 101A Feeder 3B MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, 12 99 101A Feeder 3B MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 10, 9 99 101A feeder 3C MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 8, 8 99 101A feeder 3C MDP2 Magnus DS Power CB 800A 99 101A Feeder 3D MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 10, 8, 6 99 101A Feeder 3D MDP2 Magnus DS Power CB 800A LTD, STPU, INST 12, 6, 6 24, 8, 6.5 99 101A Feeder 4A MDP1 Magnus DS Power CB 800A LTPU, LTD, STPU, INST 06, 2, 2, 2 1, 24, 7, 7 99 101A Feeder 4A MDP2 Magnus DS Power CB 800A 99 101A Feeder 4B MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 4B MDP2 Magnus DS Power CB 800A 99 101A Feeder 4C MDP1 Magnus DS Power CB 800A 99 101A Feeder 4C MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 10, 10 99 101A Feeder 4D MDP1 Magnus DS Power CB 800A 99 101A Feeder 4D MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, 10 99 101A Feeder 5A MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 5A MDP2 Magnus DS Power CB 800A 99 101A Feeder 5B MDP1 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 5B MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 8, 8, 7 99 101A Feeder 5C MDP1 Magnus DS Power CB 800A LTPU, LTD, STPU, INST 0.9, 2, 2, 2 1, 24, 14, M1(14) 99 101A Feeder 5C MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 5D MDP1 Magnus DS Power CB 800A LTPU, LTD, STPU, INST 0.9, 2, 2, 2 1, 24, 14, M1(14) 99 101A Feeder 5D MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 6A MDP1 Magnus DS Power CB 800A 99 101A Feeder 6A MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 8, 8 99 101A Feeder 6B MDP1 Magnus DS Power CB 800A

Page 3 https://vaww.aams.ecms.va.gov/AAMS_Production/DAV/6‐syyyykydn‐0‐yy/Maintenance Inventory 2020

99 101A Feeder 6B MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 18, 8, 7 99 101A Feeder 6C MDP1 Magnus DS Power CB 800A STPU, INST, GFD 14, M1(14), 0.5 8, 7, 0.4 99 101A Feeder 6C MDP2 Magnus DS Power CB 800A LTPU, LTD, STPU, INST 2, 4, 0.2, OFF, 6 8, 5, 0.3, ON. 8 99 101A Feeder 6D MDP1 Magnus DS Power CB 800A LTD, STPU, INST, GFD 2, 2, 2, 0.1 12.5, 6, 5.5, 0.2 99 101A Feeder 6D MDP2 Magnus DS Power CB 800A LTD, STPU, INST 2, 2, 2 24, 14, M1(14) 99 101A Feeder 7D MDP1 Magnus DS Power CB 800A LTD, STPU, INST, GFPU, GFD 2, 2, 2, 1, 0.1 12, 8, 8, 0.75, 0.2 99 101A MDP‐1 Switchgear cabinet 99 101A MDP‐1 Incoming Volt Relay BE1‐47N 99 101A MDP‐1 IQ Analyzer IQ Analyzer 99 101A MDP‐2 Switchgear cabinet 99 101A MDP‐2 Incoming Volt Relay BE1‐47N 99 101A MDP‐2 IQ Analyzer IQ Analyzer 99 101A Voltmeter PoweLogic voltmeter 99 101A Voltmeter PoweLogic voltmeter 99 101B ATS‐Clinical ATS w/Bypass 99 101B ATS‐EQ ATS w/Bypass 99 101B ATS‐LS ATS w/Bypass 99 101B MDP‐EQ Main MDPEQ99 MCCB 99 Gen Rm ATS‐1 ATS w/Bypass 99 Gen Rm ATS‐2 ATS w/Bypass 99 Gen Rm Emergency Switchboard Switchgear cabinet 99 Outside Transformer #10 Pad Mounted Transformer 99 Outside Transformer #11 Pad Mounted Transformer 99 Outside Transformer #9 Pad Mounted Transformer 150 Fire Pump Transfer Sw ATS w/Bypass 998 998 main MCCB