36C24419B0046-0003006.pdf

PDF 33 KB Posted

Attached to
EMPI Funded-Emergency Generator 2B Federal contract opportunity
Solicitation number
36C24419B0046
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

36C24419B0046 0003 S06 Spec Section 05 12 00 Structural Steel Framing 7-24-19.pdf

View the file

Other files for this federal contract opportunity

Other files attached to EMPI Funded-Emergency Generator 2B, newest first.
File Type Posted
36C24419C0192-001.docx DOCX document
36C24419B0046-0003008.pdf PDF
36C24419B0046-0003002.pdf PDF
36C24419B0046-0003003.pdf PDF
36C24419B0046-0003005.pdf PDF
36C24419B0046-0003007.doc DOC document
36C24419B0046-0003000.docx DOCX document
36C24419B0046-0003009.pdf PDF
36C24419B0046-0003004.pdf PDF
36C24419B0046-0003001.docx DOCX document
36C24419B0046-0002000.docx DOCX document
36C24419B0046-0002001.docx DOCX document
36C24419B0046-0002002.docx DOCX document
36C24419B0046-0001003.zip ZIP file
36C24419B0046-0001000.docx DOCX document
36C24419B0046-0001001.docx DOCX document
36C24419B0046-0001005.zip ZIP file
36C24419B0046-0001002.zip ZIP file
36C24419B0046-0001004.zip ZIP file
S02_Drawings_-_Electrical.zip ZIP file
S02_Drawings_-_Mechanical.zip ZIP file
S02_Drawings_-_Structural.zip ZIP file
S02_Specification_for_Emergency_Power_Phase_2B.zip ZIP file
S02_GI001_Cover_Sheet.pdf PDF
S02_Wage_Determination_06-14-2019.pdf PDF
36C24419B0046-003.docx DOCX document
36C24419B0046-000.docx DOCX document
36C24419B0046-000.docx DOCX document
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Erie VA Medical Center VA Project #562-17-309 Replace Legacy EPSS Bid Document Submission Erie, PA July 24, 2019

05 12 00 - 1

SECTION 05 12 00

STRUCTURAL STEEL FRAMING

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Structural steel shapes, plates, and bars.

2. Bolts, nuts, and washers.

1.2 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. American Institute of Steel Construction (AISC):

1. AISC Manual - Steel Construction Manual, 14th Ed.

2. 303-10 - Code of Structural Steel Buildings and Bri dges.

3. 360-10: Specification for Structural Steel Building s.

C. The American Society of Mechanical Engineers (ASME) :

1. B18.22.1-09 - Washers: Helical Spring-Lock, Tooth L ock, and Plain

Washers.

D. American Welding Society (AWS):

1. D1.1/D1.1M-15 - Structural Welding Code - Steel.

E. ASTM International (ASTM):

1. A6/A6M-14 - General Requirements for Rolled Structu ral Steel Bars, Plates, Shapes, and Sheet Piling.

2. A36/A36M-14 - Carbon Structural Steel.

3. A53/A53M-12 - Pipe, Steel, Black and Hot-Dip, Zinc- Coated, Welded and Seamless.

4. A123/A123M-15 - Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel

Products.

5. A242/A242M-13 - High-Strength Low-Alloy Structural Steel.

6. A283/A283M-13 - Low and Intermediate Tensile Streng th Carbon Steel

Plates.

7. A307-14 - Carbon Steel Bolts, Studs, and Threaded R od 60,000 PSI

Tensile Strength.

8. A500/A500M-13 - Cold-Formed Welded and Seamless Car bon Steel

Structural Tubing and Rounds and Shapes.

9. A501/A501M-14 - Hot-Formed Welded and Seamless Carb on Steel

Structural Tubing and Rounds and Shapes.

05 12 00 - 2

10. A572/A572M-15 - High-Strength Low-Alloy Columbium-V anadium

Structural Steel.

11. A992/A992M-15 - Structural Shapes.

12. F2329/F2329M-15 - Zinc Coating, Hot-Dip, Requiremen ts for

Application to Carbon and Alloy steel Bolts, Screws , washers, Nuts, and Special Threaded Fasteners.

13. F3125/F3125M-15 - Standard Specification for High S trength

Structural Bolts, Steel and Alloy Steel, Heat Treat ed, 120 ksi (830

MPa) and 150 ksi (1040 MPa) Minimum Tensile Strengt h, Inch and

Metric Dimensions

F. Master Painters Institute (MPI):

1. No. 18 - Primer, Zinc Rich, Organic.

G. Military Specifications (Mil. Spec.):

1. MIL-P-21035 - Paint, High Zinc Dust Content, Galvan izing, Repair.

H. Occupational Safety and Health Administration (OSHA ):

1. 29 CFR 1926.752(e) - Guidelines For Establishing Th e Components Of A

Site-Specific Erection Plan.

2. 29 CFR 1926-2001 - Safety Standards for Steel Erect ion.

I. Research Council on Structural Connections (RCSC) o f The Engineering

Foundation:

1. Specification for Structural Joints Using ASTM F312 5 Bolts.

1.3 SUBMITTALS

A. Submittal Procedures: Section 01 33 23, SHOP DRAWIN GS, PRODUCT DATA, AND SAMPLES.

B. Submittal Drawings:

1. Show size, configuration, and fabrication and insta llation details.

C. Test Reports: Certify products comply with specific ations.

1. Welders' qualifying tests.

D. Certificates: Certify each product complies with sp ecifications.

1. Structural steel.

2. Steel connections.

3. Welding materials.

4. Shop coat primer paint.

E. Qualifications: Substantiate qualifications comply with specifications.

1. Fabricator with project experience list.

2. Installer with project experience list.

05 12 00 - 3

3. Welders and welding procedures.

F. Record Surveys.

1.4 QUALITY ASSURANCE

A. Fabricator Qualifications:

1. Regularly fabricates specified products.

2. Fabricated specified products with satisfactory ser vice on five similar installations for minimum five years.

a. Project Experience List: Provide contact names and addresses for completed projects.

B. Installer Qualifications:

1. Regularly installs specified products.

2. Installed specified products with satisfactory serv ice on five similar installations for minimum five years.

a. Project Experience List: Provide contact names and addresses for completed projects.

C. Before commencement of Work, ensure steel erector p rovides written notification required by OSHA 29 CFR 1926.752(e). S ubmit a copy of the notification to Contracting Officer's Representativ e.

D. Welders and Welding Procedures Qualifications: AWS D1.1/D1.1M.

1.5 WARRANTY

Construction Warranty: FAR clause 52.246-21, "Warra nty of

Construction."

PART 2 - PRODUCTS

2.1 SYSTEM PERFORMANCE

A. Design structural steel framing connections complyi ng with specified performance:

1. Configuration: Design and detail all connections fo r each member size, steel grade and connection type to resist the loads and reactions indicated on the drawings or specified he rein. Use details consistent with details shown on drawings, suppleme nting where necessary. The details shown on drawings are concep tual and do not indicate the required weld sizes or number of bolts unless specifically noted. Use rational engineering design and standard practice in detailing, accounting for all loads and eccentricities in both the connection and the members. Promptly no tify the COR of

05 12 00 - 4 any location where the connection design criteria i s not clearly indicated. The design of all connections is subject to the review and acceptance of the COR.

2.2 MATERIALS

A. W-Shapes:

1. ASTM A992/A992M.

B. Channel and Angles:

1. ASTM A36/A36M.

C. Plates and Bars:

1. ASTM A36/A36M.

D. Bolts, Nuts and Washers: Galvanized for galvanized framing and plain finish for other framing.

1. High-strength bolts, including nuts and washers: A STM F3125.

2. Bolts and nuts, other than high-strength: ASTM A307 , Grade A.

3. Plain washers, other than those in contact with hig h-strength bolt heads and nuts: ASME B18.22.1.

E. Welding Materials: AWS D1.1, type to suit applicati on.

2.3 FABRICATION

A. Fabricate structural steel according to Chapter M, AISC 360.

B. Shop and Field Connections:

1. Weld connections according to AWS D1.1/D1.1M. Welds shall be made only by welders and welding operators who have been previously qualified by tests as prescribed in AWS D1.1 to per form type of work required.

2. High-Strength Bolts: High-strength bolts tightened to a bolt tension minimum 70 percent of their minimum tensile strengt h. Tightening done with properly calibrated wrenches, by turn-of- nut method or by use of direct tension indicators (bolts or washers) . Tighten bolts in connections identified as slip-critical using Di rect Tension

Indicators. Twist-off torque bolts are not an accep table alternate fastener for slip critical connections.

2.4 FINISHES

A. Shop Priming:

1. Prime paint structural steel according to AISC 303, Section 6.

B. Do not paint:

1. Surfaces within 50 mm (2 inches) of field welded jo ints.

05 12 00 - 5

2. Surfaces indicated to be encased in concrete.

3. Surfaces receiving sprayed on fireproofing.

4. Beam top flanges receiving shear connector studs ap plied.

C. Structural Steel Galvanizing: ASTM A123/A123M, hot dipped, after fabrication. Touch-up after erection: Clean and wir e brush any abraded and other spots worn through zinc coating, includin g threaded portions of bolts and welds and touch-up with galvanizing re pair paint.

1. Galvanize structural steel framing installed at ext erior locations.

D. Bolts, Nuts, and Washers Galvanizing: ASTM F2329, h ot-dipped.

2.5 ACCESSORIES

A. General: Shop paint steel according to AISC 303, Se ction 6.

B. Galvanizing Repair Paint: MPI No. 18.

PART 3 - EXECUTION

3.1 ERECTION

A. Erect structural steel according to AISC 303 and AI SC 360.

B. Set structural steel accurately at locations and el evations indicated on drawings.

C. Maintain erection tolerances of structural steel wi thin AISC 303 requirements.

1. Pour Stop Elevation Tolerance: 6 mm (1/4 inch), max imum, before concrete placement.

D. Weld and bolt connections as specified for shop con nections.

3.2 FIELD PAINTING

A. After welding, clean and prime weld areas to match adjacent finish.

B. Touch-up primer damaged by construction operations.

C. Apply galvanizing repair paint to galvanized coatin gs damaged by construction operations.

3.3 FIELD QUALITY CONTROL

A. Record Survey:

1. Measure and record structural steel framing plumbne ss, level, and alignment after completing bolting and welding and before installation of work supported by structural steel.

2. Identify deviations from allowable tolerances speci fied in

AISC Manual.

File details come from the government source that posted it.