36C24418B0529-108.pdf
PDF 12 MB Posted
- Attached to
- Wayfinding Project Federal contract opportunity
- Solicitation number
- 36C24418B0529
About this file
36C24418B0529 S02 DRAWINGS 1-10.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24418B0529-0001025.docx | DOCX document | |
| 36C24418B0529-106.docx | DOCX document | |
| 36C24418B0529-116.pdf | ||
| 36C24418B0529-117.pdf | ||
| 36C24418B0529-115.pdf | ||
| 36C24418B0529-114.pdf | ||
| 36C24418B0529-119.pdf | ||
| 36C24418B0529-109.pdf | ||
| 36C24418B0529-120.pdf | ||
| 36C24418B0529-113.pdf | ||
| 36C24418B0529-122.pdf | ||
| 36C24418B0529-118.pdf | ||
| 36C24418B0529-124.pdf | ||
| 36C24418B0529-121.pdf | ||
| 36C24418B0529-107.pdf | ||
| 36C24418B0529-111.pdf | ||
| 36C24418B0529-110.pdf | ||
| 36C24418B0529-123.pdf | ||
| 36C24418B0529-112.pdf | ||
| 36C24418B0529-037.docx | DOCX document |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C8X11.5
3'-4" X 0'-8" X 34"
THICK STEEL
PLATE
0'-8"
1/4
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
0'-93 4"
0'-8" 1'-0" 1'-0" 0'-8"
(3) 5 8•• •• •• • ••• •• •• • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
8•• •• • • • •• • • • • •• • • •• • • •• • • • •
BOLTS (EMBED. 6" MIN.)
0'-47 8"
3'-4"
TYP.
2'-103
4"
0'-93 4"
4'-0"
2'-0"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
5'-4"
3'-4"
2'-103 4"
3'-6"
4'-0"
2'-101 2"
3'-6"
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
C8X11.5
2'-8"
FIN. GRADE
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
BRICK
(BY OTHERS)
#4 TIES @
12" O.C.
(3) #5 BARS EQ.
SPACED T&B
#5 VERT. BARS @
12" O.C. W/ 12" LEG
#4 HORIZ. BARS
@ 12" O.C.
2'-0"
2'-101 2"
0'-91 4"
0'-8"
5'-4"
3'-6"
C8X11.5
2'-8"
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
(3) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 12" LEG
5'-7"
13'-3"
6'-0"
3'-6" 2'-101 2"
5'-71 2"
C12x20.7
5'-01 4"
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
FIN. GRADE
1'-0"
13'-3"
3'-6" 2'-101 2"
4'-0"
1'-11 4"
C12X20.7
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
(5) #5 BARS EQ.
SPACED T&B
5'-01 4"
6'-0"
3'-6"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
1'-13 4"
C12X20.7
5'-7" X 1'-0" X 1"
THICK STEEL
PLATE
1'-0"
5'-7"
1/4 TYP.
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
(8) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • • •
BOLTS (EMBED. 6" MIN.)
1'-13 4"
2" MIN.
0'-6" 1'-4" 1'-4" 1'-4" 0'-6"
0'-41 2"
6'-0"
3'-6" 2'-101 2"
11'-9"
5'-7"
5'-71 2"
5'-01 4"
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 24" LEG
FIN. GRADE
C12x20.7
3'-6" 2'-101 2"
3'-6"
1'-11 4"
11'-9"
1'-0"
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 18" LEG
(5) #5 BARS EQ.
SPACED T&B
C12X20.7
5'-01 4"
6'-0"
3'-6"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
1'-13 4" C12X20.7
5'-7" X 1'-0" X 1"
THICK STEEL
PLATE
1'-0"
5'-7"
1/4 TYP.
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
(8) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • •
BOLTS (EMBED. 6" MIN.)
2" MIN.
0'-6" 1'-4" 1'-4" 1'-4" 0'-6"
0'-41 2"
1'-13 4"
BASE PLATE DETAIL
TOP PLAN
FACE A ELEVATION SIDE ELEVATION
SCALE 1/4" = 1'-0"
FACE A ELEVATION SCALE 1/4" = 1'-0"
SIDE ELEVATION
SCALE 1/4" = 1'-0"
TOP PLAN
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
SIDE ELEVATION
SCALE 1/4" = 1'-0"
TOP PLAN
SCALE 1" = 1'-0"
BASE PLATE DETAIL
REINFORCING STEEL
1. REINFORCING STEEL SHALL BE DETAILED, INCLUDING HOOKS AND BENDS, AND PLACED IN ACCORDANCE WITH ACI
315 AND ACI 318.
2. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 OR A-706, GRADE 60.
3. ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
4. REINFORCING SPLICES SHALL BE MADE IN ACCORDANCE WITH CRSI LATEST EDITION (TENSION SPLICE CLASS "B").
5. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE
VERTICAL REINFORCING, RESPECTIVELY, UON.
6. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED
AND REVIEWED BY THE STRUCTURAL ENGINEER.
7. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED.
DESIGN LOADING
1. ALL FOUNDATIONS WERE DESIGNED IN ACCORDANCE TO 2009 INTERNATIONAL BUILDING CODE (2012 IBC) AND
ACI318-'05 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY".
2. THE FOUNDATIONS WERE DESIGNED BY USING THE APPROPRIATE LOAD COMBINATIONS TO GENERATE THE MAXIMUM LOAD EFFECTS, CONSIDERING BOTH THE STRENGTH AND STABILITY OF THE FOUNDATIONS . DEAD, LIVE, SNOW, WIND, SEISMIC, AND OTHER APPLICABLE LOADS WERE COMBINED USING THE FOLLOWING LOAD CASES, AS
REQUIRED BY ASCE 7-05, AND IBC 2012:
STRENGTH DESIGN: STABILITY DESIGN:
A: 1.4 DL A: 1.0 DL
B: 1.2 DL + 1.6 LL + 0.5 SL B: 1.0 DL + 1.0 L
C: 1.2 DL + 1.6 LL + 0.8 WL C: 1.0 DL + 1.0 SL
D: 1.2 DL + 1.6 WL + 1.0 LL + 0.5 SL D: 1.0 DL + 0.75 LL + 0.75 WL
E: 1.2 DL + 1.0 EL + 1.0 LL + 0.2 SL E: 1.0 DL + 1.0 WL
F: 0.9 DL + 1.6 WL F: 1.0 DL + 0.75 LL + 0.75 WL + 0.75 SL
G: 0.9 DL + 1.0 EL G: 0.6 DL + 1.0 WL
H: 0.6 DL + 0.7 EL
3. ALL FOUNDATIONS WERE DESIGNED FOR A MAXIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF.
CONCRETE
1. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE 'BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE' ACI 318 AND ACI 301, WITH MODIFICATIONS AS NOTED IN THE CONTRACT DOCUMENTS.
2. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 TYPE 1 OR TYPE II.
3. COARSE AND FINE AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33.
4. WATER SHALL BE CLEAR AND SHALL CONFORM TO ASTM C-94.
5. CONCRETE MIXING OPERATION SHALL CONFORM TO ASTM C-94.
6. ALL CONCRETE EXPOSED TO WEATHER SHALL BE ADMIXED WITH MICROAIR OR MBVR AIR ENTRAINING AGENT BY MASTERBUILDERS TO ATTAIN 5 PERCENT +/- 1 PERCENT ENTRAINED AIR, BY VOLUME, CONFORMING TO ASTM C-260.
ALL REFERENCE DATA USED FOR PAST PERFORMANCE DESIGN SHALL HAVE CONTAINED THE SAME ADMIXTURE
BRAND AS THAT USED IN THE MIX SUBMITTED.
7. ALL CONCRETE SHALL BE REQUIRED TO OBTAIN A MIMIMUM COMPRESSIVE STRENGTH OF 4,000 PSI. CONCRETE
STRENGTHS SHALL BE VERIFIED BY 28-DAY CYLINDER TESTS, UNLESS OTHERWISE APPROVED.
8. CONTRACTOR MAY USE AN ADMIXTURE SYSTEM TO PRODUCE FLOWABLE CONCRETE. MAXIMUM SLUMP SHALL NOT EXCEED 10 INCHES MEASURED AT THE PUMP. THE WATER/CEMENTIOUS MATERIAL RATIO OF THE APPROVED MIXES SHALL BE MAINTAINED OR LOWERED WHEN FLOWABLE CONCRETE IS USED. A REPRESENTATIVE OF THE ADMIXTURE SYSTEM SHALL ASSIST IN DETERMINING PROPORTIONS FOR FLOWABLE CONCRETE AND SHALL BE REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER AND ARCHITECT PRIOR TO EMPLOYING THIS
PROCEDURE.
9. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT PLACED IN CAST-IN-PLACE
CONCRETE:
CONCRETE
COVER
(MINIMUM)
A. CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 THROUGH #18 BARS 2"
#5 BAR, W31 OR D31 WIRE, AND SMALLER 1 1/2"
10. PROJECTING CORNERS OF BEAMS, WALLS, COLUMNS, ETC., SHALL BE FORMED WITH A 3/4 INCH CHAMFER, UNLESS
OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS.
11. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION
PRIOR TO PLACING CONCRETE.
12. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. REINFORCING
SHALL NOT BE CUT. CORING OF CONCRETE IS NOT PERMITTED EXCEPT AS INDICATED.
13. CURING COMPOUNDS USED ON CONCRETE TO RECEIVE A FINISH SHALL BE APPROVED BY THE FINISH APPLICATOR
BEFORE USE.
13. ALL JOINTS BETWEEN SEPARATE POURS SHALL BE KEYED TOGETHER. MIMIMUM KEY SIZE SHALL BE 2"DP X 4"W.
UNLESS OTHERWISE NOTED.
GENERAL NOTES:
1. THIS SECTION PROVIDES GUIDELINES FOR THE CONSTRUCTION OF REINFORCED CONCRETE FOUNDATIONS.
PROPER CONCRETE PRE-PLACEMENT AND PLACEMENT PROCEDURES ARE ESSENTIAL TO THE SUCCESSFUL
INSTALLATION OF SIGNAGE FOUNDATIONS.
2. CONSTRUCTION OF THE FOUNDATION SHALL BE PERFORMED IN A SAFE MANNER AND SHALL BE SUBJECT TO ALL
OSHA SAFETY REQUIREMENTS.
3. EXCAVATIONS FOR THE FOUNDATION SHALL BE MADE SAFE TO PREVENT ANY DANGER TO PERSONNEL OR
EXISTING STRUCTURES.
4. THE OWNER SHALL BE ADVISED IF CONSTRUCTION OF THE FOUNDATION WILL BLOCK AN EXISTING MEANS OF
EMERGENCY EGRESS FOR PERSONNEL AND/OR SAFETY EQUIPMENT.
SOIL CONDITIONS:
1. FOUNDATIONS WERE DESIGNED ASSUMING A MAXIMUM SOIL BEARING PRESSURE OF 2000 PSF.
2. FOUNDATIONS DESIGNED TO BE DIRECTLY SUPPORTED ON SOIL SHALL BE CONSTRUCTED ON UNDISTURBED SOIL OR FILL MATERIAL PROPERLY COMPACTED IN ACCORDANCE WITH SOUND ENGINEERING PRACTICES AND THE
PROJECT SPECIFICATIONS.
3. UNLESS OTHERWISE SPECIFIED, THE CONTRACTOR SHALL REQUIRE A QUALIFIED SOIL SPECIALIST TO INSPECT THE SOIL SUPPORTING THE FOUNDATION AND DETERMINE ITS ADEQUACY TO PROVIDE THE REQUIRED BEARING
CAPACITY.
4. UNLESS OTHERWISE SPECIFIED, PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT FOR ACCEPTANCE AND REVIEW THE QUALIFICATIONS OF THE PERSON RESPONSIBLE FOR PERFORMING THE SOIL
INSPECTION SPECIFIED IN 3.3.2.
FORMWORK:
1. ALL FORMWORK AND FORM ACCESSORIES SHALL BE IN ACCORDANCE WITH ACI 301.
2. UNLESS OTHERWISE INDICATED ON THE CONTRACT DRAWINGS, PROVIDE MINIMUM (3
4-INCH) CHAMFER STRIPS AT
ALL CORNERS ON PERMANENTLY EXPOSED SURFACES OR ON EDGES OF FORMED JOINTS.
3. UNLESS OTHERWISE SPECIFIED BY THE USER, REMOVAL OF FORMWORK SHALL BE IN ACCORDANCE WITH ACI 301.
REINFORCING STEEL:
1. REINFORCING STEEL MATERIALS, FABRICATION, AND PLACEMENT SHALL BE IN ACCORDANCE WITH ACI 301.
2. UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWING, ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615, "STANDARD SPECIFICATION FOR DEFORMED AND PLAIN BILLET-STEEL BARS FOR CONCRETE REINFORCEMENT," GRADE 60, WITH A MINIMUM YIELD STRENGTH OF 60 KIPS PER SQUARE INCH.
ANCHOR BOLTS AND SLEEVES:
1. ANCHOR BOLTS AND SLEEVES SHALL BE LOCATED TO THE SPECIFIED TOLERANCES IN ALL THREE PLANES AND
SECURELY SUPPORTED TO PREVENT MISALIGNMENT DURING THE CONCRETE PLACEMENT OPERATION. THE ANCHOR BOLTS SHALL NOT BE REDUCED IN DIAMETER NOR OFFSET TO FACILITATE ALIGNMENT WITH THE MOUNTING PLATE. MODIFICATION OF THE MOUNTING PLATE TO FACILITATE ALIGNMENT IS NOT PERMITTED UNLESS
AUTHORIZED BY THE DESIGNATED VA REPRESENTATIVE.
NOTE: THE USE OF A TEMPLATE AID IN THE PLACEMENT OF ANCHOR BOLTS IS RECOMMENDED. THE
TEMPLATE WILL ASSIST IN ACCURATELY PLACING THE ANCHOR BOLTS.
FIELD VERIFICATION PRIOR TO CONCRETE PLACEMENT:
1. IMMEDIATELY PRIOR TO CONCRETE PLACEMENT, THE ANCHOR BOLT LOCATIONS, PROJECTIONS, AND DIAMETERS
SHALL BE FIELD VERIFIED TO MATCH THE ANCHOR BOLT HOLE LOCATION IN THE MOUNTING PLATE. IN THE EVENT THAT THE BASEPLATE IS NOT AT THE SITE, THE ANCHOR BOLTS' LOCATION SHALL BE VERIFIED AGAINST THE STRUCTURAL FOUNDATION DRAWINGS AND THE MANUFACTURER'S DRAWINGS. THE ANCHOR BOLTS SHALL ALSO BE EXAMINED TO VERIFY THAT THEY HAVE BEEN INSTALLED PLUMB, HAVE THE CORRECT LENGTH AND PROJECTION, ARE ADEQUATELY SECURED TO PREVENT DISPLACEMENT DURING THE CONCRETE PLACEMENT, AND THE THREADS ARE NOT STRIPPED OR DAMAGED. ALL NECESSARY PROCEDURES SHALL BE TAKEN TO CORRECT ANY DISCREPANCIES OR DEFICIENCIES BEFORE CONCRETE OPERATIONS SHALL BE PERMITTED TO BEGIN.
2. ALL ANCHOR BOLT SLEEVES SHALL BE COVERED OR FILLED WITH A NONBONDING MOLDABLE MATERIAL TO
PREVENT ENTRY OF CONCRETE.
3. PRIOR TO CONCRETE PLACEMENT, THE PROPOSED ELEVATION OF THE TOP OF THE FOUNDATION CONCRETE SHALL BE VERIFIED WITH THE ELEVATION SPECIFIED ON THE FOUNDATION DRAWING, AND THE NECESSARY PROCEDURES
SHALL BE TAKEN TO CORRECT ANY DISCREPANCIES.
GENERAL FOUNDATION NOTES
CONCRETE MIXING AND PLACEMENT PROCEDURES:
1. CONCRETE MATERIALS, FORMWORK, HANDLING, MIXING, AND PLACEMENT SHALL CONFORM TO ACI 301.
2. MATERIALS, MIXING, HANDLING, AND PLACEMENT OF MASS CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301.
ADEQUATE CONTROL OF THE CONCRETE TEMPERATURE SHALL BE MAINTAINED AT THE POUR POINT.
3. UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS, AT THE POINT OF DELIVERY, CONCRETE SHALL HAVE MAXIMUM SLUMP OF 4 INCHES WHEN ACHIEVED BY WATER ALONE. IF A SLUMP GREATER THAN 4 INCHES IS REQUIRED FOR PROPER PLACEMENT OF CONCRETE, IT MAY BE INCREASED UP TO 8 INCHES USING AN APPROVED HIGH-RANGE
WATER-REDUCING AGENT.
4. THE FIELD ADDITION OF WATER TO INCREASE THE SLUMP SHALL NOT BE PERMITTED WITHOUT APPROVAL OF THE
USER.
5. FOUNDATIONS SHALL BE MADE IN ONE CONTINUOUS POUR UNLESS OTHERWISE APPROVED BY THE USER OR
SHOWN ON THE DRAWINGS.
6. IMMEDIATELY AFTER PLACEMENT, CONCRETE SHALL BE PROTECTED FROM COLD OR HOT WEATHER EXTREMES, MECHANICAL INJURY, AND PREMATURE DRYING AND SHALL BE CURED AS SPECIFIED IN ACI 301.
7. UNLESS OTHERWISE APPROVED BY THE USER, THE FOUNDATION PREPARATION PROCEDURES FOR GROUTING SPECIFIED IN THE GROUTING SECTION OF THIS SPECIFICATION OR THE SETTING OF ANY EQUIPMENT ON THE FOUNDATION SHALL NOT BE PERMITTED TO BEGIN UNTIL CONCRETE CURING IN ACCORDANCE WITH ACI 301 HAS BEEN COMPLETED, AND THE CONCRETE HAS ATTAINED THE SPECIFIED 28-DAY COMPRESSIVE STRENGTH AS
DEFINED IN ACI 301.
8. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 POUNDS PER SQUARE INCH AT 28 DAYS, UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS.
9. HIGH EARLY STRENGTH CONCRETE SHALL BE USED ONLY WITH THE APPROVAL OF THE EQUIPMENT USER AND
ENGINEER.
CONCRETE QUALITY CONTROL:
1. THE OWNER RESERVES THE RIGHT TO SUBJECT THE CONCRETE FOUNDATION CONSTRUCTION TO INSPECTION BY
AN ACI-CERTIFIED INSPECTOR OR ANY OWNER-DESIGNATED TESTING AGENCY. TESTS OF CONCRETE COMPRESSIVE STRENGTH, AIR CONTENT, AND SLUMP SHALL BE AS DESIGNATED BY THE OWNER OR IN
ACCORDANCE WITH ACI 301.
SIGN TYPE UX-i31
SS101 SCALE: AS NOTED
SCALE 1/2" = 1'-0"
SCALE 1/2" = 1'-0" SCALE 1/2" = 1'-0"
SCALE 1-1/2" = 1'-0"
SIGN TYPE UX-iW12
SS101 SCALE: AS NOTED
SIGN TYPE UX-iW23
SS101 SCALE: AS NOTED FINAL CONSTRUCTION DOCUMENTS
3919 Saw Mill Run Boulevard, Pittsburgh, PA 15227 | wfpros.com
The Gateway Engineers, Inc.
Pittsburgh, PA
Earl Swensson Associates, Inc.
Nashville, TN
Stewart C. Cluck, Architect, LLC York, PA
STRUCTURAL PLANS,
DETAILS & NOTES
VAPHS HEINZ, PITTSBURGH, PA
646-13-105
SITE
SS101
4 643-29-2018 BDS
MASTER WAYFINDING FOR VAPHS
STRUCTURAL STEEL NOTES
1. STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (FOURTEENTH EDITION) AND THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS
AND BRIDGES".
2. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:
A.CHANNELS, ANGLES, PLATES AND MISCELLANEOUS CONNECTION MATERIAL- ASTM A36 WITH A MINIMUM
YIELD STRENGTH OF 36 KSI, U.N.O.
B.STEEL TUBE- ASTM A500, GRADE B, WITH A MINIMUM YIELD STENGTH OF 46 KSI.
3. BOLTS SHALL BE 3/4" DIAMETER ASTM A325 H.S. U.N.O. CONNECTIONS SHALL BE TYPE N FOR FRAMED
CONNECTIONS AND TYPE SC CLASS A FOR WIND MOMENT.
4. WELDING SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL WELDING CODE ANSI/AWS D1.1", AMERICAL
WELDING SOCIETY, LATEST EDITION. USE E70XX ELECTRODES.
5. FIELD WELDED SURFACES SHALL BE CLEANED, GROUND SMOOTH, AND COATED WITH APPROPRIATE
PRIMER/PAINT AS SPECIFIED.
6. STEEL IN EXTERIOR ELEMENTS OR EMBEDDED IN EXTERIOR WALL OR CAVITY SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM A-123. WHEN GALVANIZED STEEL IS FIELD WELDED, PROVIDE APPROPRIATE VENTILATION MEASURES. WELDED SURFACES SHALL BE GROUND SMOOTH AND COATED WITH
GALVANIZING REPAIR PAINT.
7. STRUCTURAL STEEL FABRICATOR SHALL PROVIDE FOR VERTICAL AND HORIZONTAL FIELD ADJUSTMENTS OF
SUPPORT ASSEMBLIES.
8. CUTS, HOLES, COPING, ETC. REQUIRED FOR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND
MADE IN THE SHOP. CUTS OR BURNING HOLES IN THE FIELD WILL NOT BE PERMITTED.
5'-01 4"
6'-0"
2'-101 2"3'-6"
14'-9"
5'-71 2"
INFILL BETWEEN POSTS W/
COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
EACH FACE
FIN. GRADE
HSS 4X4X3/8
6'-0"
6'-0"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
5'-7"
5'-7"
0'-25
8" TYP.
0'-8"
TYP.
(3) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • • • • • • •
BOLTS (EMBED. 6" MIN.)
(TYP. 4 PL.)
1/4 TYP.
HSS 4X4X3
(TYP. OF 4)
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
1'-45 8" X 0'-85
8" X 1"
THICK L-SHAPED
STEEL PLATE (TYP.
@ EACH CORNER) 0'-6"
TYP.
SIGN FACE
INFILL BETWEEN
STEEL POSTS
(BY OTHERS)
0'-85 8"
0'-85 8"
1'-45 8"
1'-45 8"
5'-01 4"
6'-0"
2'-101 2"3'-6"
7'-4"
5'-71 2"
INFILL BETWEEN POSTS W/
COLD-FORMED STEEL (BY
OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 24" LEG
EACH FACE
FIN. GRADE
C4X5.4
CONCRETE
STEM WALL
C4X5.4
(TYP. OF 6)
BRICK (BY
OTHERS)
SIGN FACE
INFILL BETWEEN
STEEL POSTS
(BY OTHERS)
(3) 5 8•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
8•• •• • • • •• • • • • •• • • •• • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • •
BOLTS (EMBED. 6" MIN.)
(TYP. 3 PL.)
STEEL PLATE (TYP.
@ EACH CORNER)
1'-9"
1'-9"
0'-85 8"
1/4 TYP.
0'-6"6'-0"
5'-01 4"
BRICK
(BY OTHERS)
CONCRETE
STEM WALL
CONCRETE
FOOTING
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
TOP PLAN
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
TOP PLAN
SCALE 1-1/2" = 1'-0"
BASE PLATE DETAIL
SIGN TYPE UX-W1.31
SS102 SCALE: AS NOTED
SIGN TYPE UX-iW32
SS102 SCALE: AS NOTED
FINAL CONSTRUCTION DOCUMENTS
3919 Saw Mill Run Boulevard, Pittsburgh, PA 15227 | wfpros.com
The Gateway Engineers, Inc.
Pittsburgh, PA
Earl Swensson Associates, Inc.
Nashville, TN
Stewart C. Cluck, Architect, LLC York, PA
STRUCTURAL PLANS,
DETAILS & NOTES
VAPHS HEINZ, PITTSBURGH, PA
646-13-105
SITE
SS102
5 643-29-2018 BDS
MASTER WAYFINDING FOR VAPHS
TYPICAL SIGN TYPE i10 & i11
TYPICAL SIGN TRACK
VERIFY LOCATION
ON SIGN STRUCTURE
LIMESTONE FACED BEAM/PILLAR
POST DRILL & EPOXY 12•• •• • • • •• • • • • • • • • • • • • • • •
OR SIZE PER SIGN MANUF.
EMBEDMENT PER EPOXY MANUF.
ANCHOR SPACING PER SIGN TRACK MANUF.
BUT NOT TO EXCEED 3'-0" O.C. MAX NEW HSS 2x2x 3
16 TUBE STEEL
LOCATE AT BRACKET LOCATIONS
NEW L2x2x1
4 ANGLE BRACKET
TO MOUNT TO SIGN TRACK.
MOUNTING BRACKET SPACING
PER SIGN MANUF BUT NOT
TO EXCEED 3'-0" O.C. MAX
TYPICAL SIGN TYPE i13
ALL TUBE STEEL MUST EXTEND
BEYOND FACADE PILASTERS
EXTERIOR BUILDING FACADE
PRECAST ELEMENTS
2•• •• • • • • • •• • •• • • • • • • • • • • • • • • • • • • • • •
3/16"
NEW L2x2x1
4 ANGLE TO MOUNT TO FACADE.
LOCATE AT BRACKET LOCATIONS
TYPICAL SIGN TRACK
CONTRACTOR TO VERIFY
LOCATION ON SIGN STRUCTURE
2•• •• • • • •• • • • •• • • • • • • • • • • • • • • • •
SIZE PER SIGN MANUF.
EX. MOUNTING TUBE STL
TO REMAIN (TYP.)
MOUNT TRACK TO NEW 14" x 4" WIDE PLATE
WELD TO EX. ANGLE & TUBE STL.
FINAL LENGTH TO BE DETERMINED BY
CONTRACTOR BASED ON SIGN TRACK SIZE.
MOUNTING PLATE SPACING PER SIGN MANUF
BUT NOT TO EXCEED 3'-0" O.C. MAX
2•• •• • • • •• • • • ••• • • ••• • • • • • • • • • • • • • • • • • • • • • •
SIZE PER SIGN MANUF.
TYPICAL SIGN TYPE i13
TYPICAL SIGN TRACK
CONTRACTOR TO VERIFY
LOCATION ON SIGN STRUCTURE
TYPICAL SIGN TYPE i14
ALL TUBE STEEL MUST EXTEND
BEYOND FACADE PILASTERS
EXTERIOR BUILDING FACADE
PRECAST ELEMENTS
CONTRACTOR TO VERIFY
EX. ANGLE TO REMAIN (TYP.)
RE-USE EXISTING BRACKETS (6 TOTAL)
RE-LOCATE END BRACKETS AS REQ'D
SO THAT END BRACKETS ARE INSTALLED
BEHIND SIGN AS SHOWN ON PLAN VIEW
INSTALL RE-LOCATED BRACKETS
WITH NEW 12•• •• • • • • • •• • •• • • • • • • • • • • • • • • • • • • • • • • • •
EX. END BRACKETS
TO BE RE-LOCATED
AS DIRECTED
NEW SIGN TYPE i13
& TRACK STRUCTURE
REMOVE END OF EX.
ANGLE MOUNTING TACK
AS DIRECTED
RE-USE EXISTING ANGLE BRACKETS
RE-USE EXISTING TUBE STEEL
BUILDING PRECAST
FACADE & PILASTERS
NEW 1
4" THICK MOUNTING PLATES FOR
2•• •• • • • •• • • • •• • •• • •• • • •• •• • •• •• • •• • • • • ••••••••••••••••••••••••••••••••••••••••
SPACING PER SIGN MANUF.
BUT NOT TO EXCEED 3'-0" O.C.
INSTALL RE-LOCATED BRACKETS
WITH NEW 5
16"x31
2" TAPCONS
RE-USE EXISTING BRACKETS (3 PER SIGN)
RE-LOCATE END BRACKETS AS REQ'D
SO THAT END BRACKETS ARE INSTALLED
APPROX. 2'-0" FROM END OF SIGN
TYPICAL SIGN TYPE R15 & R16
PROVIDE NEW STAINLESS STL EYE HOOKS,
NUTS, WASHERS, & 18•• •• • • • • •• • •• • • • • • • • • • • • • • • • • • • •
SIGN & ADJUST TO FINAL ELEVATION
EXTERIOR BUILDING FACADE
PRECAST PILASTERS
NEW L3x3x1
4 ANGLES TO BE
LOCATED AT MOUNTING
PLATE LOCATIONS
3/16"
TYPE i8 SIGN
EXISTING STL PIPE
CANOPY FRAMING
TYPICAL SIGN TRACK
CONTRACTOR TO VERIFY
LOCATION ON SIGN STRUCTURE
2•• •• • • • •• • • • •• • • • • • • • • • • • • • • • •
SIZE PER SIGN MANUF.
MOUNT TRACK TO NEW 38" x 4" WIDE PLATE
WELD TO EX. ANGLE & TUBE STL.
FINAL LENGTH TO BE DETERMINED BY
CONTRACTOR BASED ON SIGN TRACK SIZE.
MOUNTING PLATE SPACING PER SIGN MANUF
BUT NOT TO EXCEED 3'-0" O.C. MAX
3/16"
2•• •• • • • •• • • • •• • •• •• • • • • • • • • • • • • • • • • • • • • •
AS REQ'D BY MANUF.
SPACING PER MANUF.
TYPICAL SIGN TYPE i12
FOR SIGNS MOUNTED TO PILASTERS:
NO MOUNTING BRACKET REQ'D.
SIGNS NOT MOUNTED TO PILASTERS:
INSTALL 4" DEEP 14 GA Z-GIRTS OR EQ.
EACH Z-GIRT TO BE 8" LONG MIN. EXTERIOR BUILDING FACADE
PRECAST PILASTERS
2•• •• • • • • • •• • •• • • • • • • • • •
(2) PER Z-GIRT
MIN. (2) Z-GIRTS PER LETTER
NEW SIGN TYPE i12
PRECAST PILASTER14 GA Z-GIRTS
TYPE i9 SIGN
EXISTING
BRICK FACADE
TYPICAL SIGN TRACK
CONTRACTOR TO VERIFY
LOCATION ON SIGN STRUCTURE
MOUNT SPACING PER SIGN TRACK MANUF.
BUT NOT TO EXCEED 3'-0" O.C. MAX
TAPCON MIN SIZE 5
16"x31
2"
3 ANCHORS MIN PER SIGN
TYPE W2 SIGN
2 SIGNS MOUNT TO EXISTING STONE WALL
1 SIGN MOUNT TO EXISTING PRECAST BLDG FACADE
POST DRILL & EPOXY 12•• •• • • • •• • • • • • • • • • • • • •
OR SIZE PER EPOXY MANUF.
5" MIN. EMBEDMENT.
FRAME SIGN WITH
(4) C3x4.1 CHANNELS
2X3X1/4" STRUCTURAL
ALUMINUM ANGLE.
WELD TO CABINET FRAME
ALUMINUM CLADDING W/
ROUTED FACE SECURED W/
CONCEALED FASTENERS TO
CABINET FRAME
POST DRILL & EPOXY 12•• •• • • • •
OR SIZE PER EPOXY MANUF.
5" MIN. EMBEDMENT.
CONSTRUCTION NOTES:
1. ALL DIMENSIONS & DETAILS OF EXISTING STRUCTURE ARE APPROXIMATE.
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS. NOTIFY ENGINEER OF
ANY DISCREPANCIES BETWEEN THESE PLANS & FIELD CONDITIONS.
2. STEEL BOLTS & CONNECTION MEMBERS SHALL NOT BE IN DIRECT
CONTACT WITH ALUMINUM SIGNS OR TRACKS. CONTRACTOR TO PROVIDE
INSULATING WASHERS AT ALL CONNECTIONS.
3. SIGN ANCHOR SIZES SHALL BE 12•• •• • • • •• • ••••••••••••5
16"x31
2" TAPCONS U.N.O., OR
SHALL BE SIZED PER SIGN MANUFACTURER RECOMMENDATIONS.
4. SIGN ANCHOR SPACING SHALL BE PER MANUFACTURER REQUIREMENTS,
BUT SHALL NOT EXCEED 3 FEET ON CENTER U.N.O.
5. EPOXY SHALL BE HILTI HY-200 OR APPROVED EQUAL. DRILL PILOT HOLE
PRIOR TO ANCHOR HOLE AND INSTALLATION.
6. ANCHORS INTO STONE FACADE AND LIMESTONE SHALL BE INSTALLED IN
HIT-S PLASTIC MESH OR APPROVED EQUAL.
SIGN TYPE i10 & i11 SECTION1
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i13 (BACK ENTRANCE ONLY)- SECTION2
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i13 & i14 (FRONT ENTRANCE ONLY)- SECTION3
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i13 (FRONT ENTRANCE ONLY)- PLAN4
SS103 SCALE: 1/2" = 1'-0"
SIGN TYPE i12- SECTION5
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i12- PLAN6
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i8- SECTION8
SS103 SCALE: 1" = 1'-0"
SIGN TYPE R15 & R16- SECTION7
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i9- SECTION9
SS103 SCALE: 1" = 1'-0"
SIGN TYPE W2- SECTION10
SS103 SCALE: 1" = 1'-0"
SIGN TYPE i9- SECTION11
SS103 SCALE: 1" = 1'-0"
FINAL CONSTRUCTION DOCUMENTS
3919 Saw Mill Run Boulevard, Pittsburgh, PA 15227 | wfpros.com
The Gateway Engineers, Inc.
Pittsburgh, PA
Earl Swensson Associates, Inc.
Nashville, TN
Stewart C. Cluck, Architect, LLC York, PA
STRUCTURAL PLANS,
DETAILS & NOTES
VAPHS HEINZ, PITTSBURGH, PA
646-13-105
SITE
SS103
6 643-29-2018 BDS
MASTER WAYFINDING FOR VAPHS
SEE 1/S-101
FOR DETAILS
HX-N1 = 4'-1"
HX-W4 = 4'-1"
HX-i2 = 3'-9"
HX-N1 = 3'-7"
HX-W4 = 3'-7"
HX-i2 = 5'-91
4"
HX-N1 = 6'-41
2"
HX-W4 = 6'-41
2"
HX-i2 = 6-111 4"
NOTE:
THE DOUBLE POST FOUNDATION
APPLIES TO SIGN TYPES HX-N1,
HX-W4, AND HX-i2
HX-N1 = 3'-9"
HX-W4 = 3'-9"
HX-i2 = 3'-5"
4'-0"
(MIN.)
#3 TIES @ 18" O.C.
(4) #4 VERT. BARS
FIN. GRADE
8" MIN. AASHTO
#57 STONE
RETAINED OR
ENGINEERED FILL
SOIL FREE OF CLAYS AND ORGANICS
COMPACTED TO 95%. OVER-EXCAVATE IF
FINE SILT, CLAYS OR ORGANICS ARE
PRESENT UNTIL SUITABLE SUBGRADE IS
DISCOVERED OR 24" BELOW BOTTOM OF
CONCRETE. PROOF-ROLL AND BACKFILL
WITH AASHTO # 57 STONE
SIGN POST, BASE PLATE
& ANCHOR BOLTS
(BY OTHERS)
6" (MIN.)
1'-0"
2'-113 4"
5'-8"
NOTE:
THE SINGLE POST FOUNDATION
APPLIES TO SIGN TYPES HX-M2,
HX-M3, AND HX-M4
#3 TIES @ 18" O.C.
(4) #4 VERT. BARS • ••• •• • • • • • •
5'-6"
12'-7"
6'-0"
3'-6" 2'-101 2"
5'-71 2"
C12X20.7
5'-01 4"
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
FIN. GRADE
1'-0"
12'-7"
3'-6" 2'-101 2"
4'-0"
1'-11 4"
C12X20.7
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
(5) #5 BARS EQ.
SPACED T&B
0'-0"
6'-0"
0'-0"4'-0"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
C12X20.7
5'-7" X 1'-0" X 1"
THICK STEEL
PLATE
1'-0"
5'-7"
1/4 TYP.
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
(8) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • • • • • • •
BOLTS (EMBED. 6" MIN.)
1'-13 4"
2" MIN.
0'-6" 1'-4" 1'-4" 1'-4" 0'-6"
0'-41 2"
8'-6"
7'-31 4"
9'-0"
3'-6" 2'-101 2"
C12X20.7
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 24" LEG
FIN. GRADE
8'-01 4"
1'-0"
7'-31 4"
3'-6" 2'-101 2"
2'-6"
1'-11 4"
C12x20.7
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 12" LEG
(3) #5 BARS EQ.
SPACED T&B
8'-01 4"
9'-0"
1'-13 4"2'-6"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
C12X20.7
8'-5-1/2" X 1'-0" X
1" THICK STEEL
PLATE
1'-0"
8'-51 2"
1/4 TYP.
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
(8) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • • • • • • • • • • • • • • • • • • • •
BOLTS (EMBED. 6" MIN.)
1'-13 4"
2" MIN.
0'-41 2"
0'-61 8" 2'-3" 2'-6" 2'-3" 0'-61
8"
REINFORCING STEEL
1. REINFORCING STEEL SHALL BE DETAILED, INCLUDING HOOKS AND BENDS, AND PLACED IN ACCORDANCE WITH ACI
315 AND ACI 318.
2. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 OR A-706, GRADE 60.
3. ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
4. REINFORCING SPLICES SHALL BE MADE IN ACCORDANCE WITH CRSI LATEST EDITION (TENSION SPLICE CLASS "B").
5. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE
VERTICAL REINFORCING, RESPECTIVELY, UON.
6. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED
AND REVIEWED BY THE STRUCTURAL ENGINEER.
7. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED.
DESIGN LOADING
1. ALL FOUNDATIONS WERE DESIGNED IN ACCORDANCE TO 2009 INTERNATIONAL BUILDING CODE (2012 IBC) AND
ACI318-'05 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY".
2. THE FOUNDATIONS WERE DESIGNED BY USING THE APPROPRIATE LOAD COMBINATIONS TO GENERATE THE MAXIMUM LOAD EFFECTS, CONSIDERING BOTH THE STRENGTH AND STABILITY OF THE FOUNDATIONS . DEAD, LIVE, SNOW, WIND, SEISMIC, AND OTHER APPLICABLE LOADS WERE COMBINED USING THE FOLLOWING LOAD CASES, AS
REQUIRED BY ASCE 7-05, AND IBC 2012:
STRENGTH DESIGN: STABILITY DESIGN:
A: 1.4 DL A: 1.0 DL
B: 1.2 DL + 1.6 LL + 0.5 SL B: 1.0 DL + 1.0 L
C: 1.2 DL + 1.6 LL + 0.8 WL C: 1.0 DL + 1.0 SL
D: 1.2 DL + 1.6 WL + 1.0 LL + 0.5 SL D: 1.0 DL + 0.75 LL + 0.75 WL
E: 1.2 DL + 1.0 EL + 1.0 LL + 0.2 SL E: 1.0 DL + 1.0 WL
F: 0.9 DL + 1.6 WL F: 1.0 DL + 0.75 LL + 0.75 WL + 0.75 SL
G: 0.9 DL + 1.0 EL G: 0.6 DL + 1.0 WL
H: 0.6 DL + 0.7 EL
3. ALL FOUNDATIONS WERE DESIGNED FOR A MAXIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF.
CONCRETE
1. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE 'BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE' ACI 318 AND ACI 301, WITH MODIFICATIONS AS NOTED IN THE CONTRACT DOCUMENTS.
2. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 TYPE 1 OR TYPE II.
3. COARSE AND FINE AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33.
4. WATER SHALL BE CLEAR AND SHALL CONFORM TO ASTM C-94.
5. CONCRETE MIXING OPERATION SHALL CONFORM TO ASTM C-94.
6. ALL CONCRETE EXPOSED TO WEATHER SHALL BE ADMIXED WITH MICROAIR OR MBVR AIR ENTRAINING AGENT BY MASTERBUILDERS TO ATTAIN 5 PERCENT +/- 1 PERCENT ENTRAINED AIR, BY VOLUME, CONFORMING TO ASTM C-260.
ALL REFERENCE DATA USED FOR PAST PERFORMANCE DESIGN SHALL HAVE CONTAINED THE SAME ADMIXTURE
BRAND AS THAT USED IN THE MIX SUBMITTED.
7. ALL CONCRETE SHALL BE REQUIRED TO OBTAIN A MIMIMUM COMPRESSIVE STRENGTH OF 4,000 PSI. CONCRETE
STRENGTHS SHALL BE VERIFIED BY 28-DAY CYLINDER TESTS, UNLESS OTHERWISE APPROVED.
8. CONTRACTOR MAY USE AN ADMIXTURE SYSTEM TO PRODUCE FLOWABLE CONCRETE. MAXIMUM SLUMP SHALL NOT EXCEED 10 INCHES MEASURED AT THE PUMP. THE WATER/CEMENTIOUS MATERIAL RATIO OF THE APPROVED MIXES SHALL BE MAINTAINED OR LOWERED WHEN FLOWABLE CONCRETE IS USED. A REPRESENTATIVE OF THE ADMIXTURE SYSTEM SHALL ASSIST IN DETERMINING PROPORTIONS FOR FLOWABLE CONCRETE AND SHALL BE REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER AND ARCHITECT PRIOR TO EMPLOYING THIS
PROCEDURE.
9. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT PLACED IN CAST-IN-PLACE
CONCRETE:
CONCRETE
COVER
(MINIMUM)
A. CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 THROUGH #18 BARS 2"
#5 BAR, W31 OR D31 WIRE, AND SMALLER 1 1/2"
10. PROJECTING CORNERS OF BEAMS, WALLS, COLUMNS, ETC., SHALL BE FORMED WITH A 3/4 INCH CHAMFER, UNLESS
OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS.
11. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION
PRIOR TO PLACING CONCRETE.
12. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. REINFORCING
SHALL NOT BE CUT. CORING OF CONCRETE IS NOT PERMITTED EXCEPT AS INDICATED.
13. CURING COMPOUNDS USED ON CONCRETE TO RECEIVE A FINISH SHALL BE APPROVED BY THE FINISH APPLICATOR
BEFORE USE.
13. ALL JOINTS BETWEEN SEPARATE POURS SHALL BE KEYED TOGETHER. MIMIMUM KEY SIZE SHALL BE 2"DP X 4"W.
UNLESS OTHERWISE NOTED.
GENERAL NOTES:
1. THIS SECTION PROVIDES GUIDELINES FOR THE CONSTRUCTION OF REINFORCED CONCRETE FOUNDATIONS.
PROPER CONCRETE PRE-PLACEMENT AND PLACEMENT PROCEDURES ARE ESSENTIAL TO THE SUCCESSFUL
INSTALLATION OF SIGNAGE FOUNDATIONS.
2. CONSTRUCTION OF THE FOUNDATION SHALL BE PERFORMED IN A SAFE MANNER AND SHALL BE SUBJECT TO ALL
OSHA SAFETY REQUIREMENTS.
3. EXCAVATIONS FOR THE FOUNDATION SHALL BE MADE SAFE TO PREVENT ANY DANGER TO PERSONNEL OR
EXISTING STRUCTURES.
4. THE OWNER SHALL BE ADVISED IF CONSTRUCTION OF THE FOUNDATION WILL BLOCK AN EXISTING MEANS OF
EMERGENCY EGRESS FOR PERSONNEL AND/OR SAFETY EQUIPMENT.
SOIL CONDITIONS:
1. FOUNDATIONS WERE DESIGNED ASSUMING A MAXIMUM SOIL BEARING PRESSURE OF 2000 PSF.
2. FOUNDATIONS DESIGNED TO BE DIRECTLY SUPPORTED ON SOIL SHALL BE CONSTRUCTED ON UNDISTURBED SOIL OR FILL MATERIAL PROPERLY COMPACTED IN ACCORDANCE WITH SOUND ENGINEERING PRACTICES AND THE
PROJECT SPECIFICATIONS.
3. UNLESS OTHERWISE SPECIFIED, THE CONTRACTOR SHALL REQUIRE A QUALIFIED SOIL SPECIALIST TO INSPECT THE SOIL SUPPORTING THE FOUNDATION AND DETERMINE ITS ADEQUACY TO PROVIDE THE REQUIRED BEARING
CAPACITY.
4. UNLESS OTHERWISE SPECIFIED, PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT FOR ACCEPTANCE AND REVIEW THE QUALIFICATIONS OF THE PERSON RESPONSIBLE FOR PERFORMING THE SOIL
INSPECTION SPECIFIED IN 3.3.2.
FORMWORK:
1. ALL FORMWORK AND FORM ACCESSORIES SHALL BE IN ACCORDANCE WITH ACI 301.
2. UNLESS OTHERWISE INDICATED ON THE CONTRACT DRAWINGS, PROVIDE MINIMUM (34-INCH) CHAMFER STRIPS AT
ALL CORNERS ON PERMANENTLY EXPOSED SURFACES OR ON EDGES OF FORMED JOINTS.
3. UNLESS OTHERWISE SPECIFIED BY THE USER, REMOVAL OF FORMWORK SHALL BE IN ACCORDANCE WITH ACI 301.
REINFORCING STEEL:
1. REINFORCING STEEL MATERIALS, FABRICATION, AND PLACEMENT SHALL BE IN ACCORDANCE WITH ACI 301.
2. UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWING, ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615, "STANDARD SPECIFICATION FOR DEFORMED AND PLAIN BILLET-STEEL BARS FOR CONCRETE REINFORCEMENT," GRADE 60, WITH A MINIMUM YIELD STRENGTH OF 60 KIPS PER SQUARE INCH.
ANCHOR BOLTS AND SLEEVES:
1. ANCHOR BOLTS AND SLEEVES SHALL BE LOCATED TO THE SPECIFIED TOLERANCES IN ALL THREE PLANES AND
SECURELY SUPPORTED TO PREVENT MISALIGNMENT DURING THE CONCRETE PLACEMENT OPERATION. THE ANCHOR BOLTS SHALL NOT BE REDUCED IN DIAMETER NOR OFFSET TO FACILITATE ALIGNMENT WITH THE MOUNTING PLATE. MODIFICATION OF THE MOUNTING PLATE TO FACILITATE ALIGNMENT IS NOT PERMITTED UNLESS
AUTHORIZED BY THE DESIGNATED VA REPRESENTATIVE.
NOTE: THE USE OF A TEMPLATE AID IN THE PLACEMENT OF ANCHOR BOLTS IS RECOMMENDED. THE
TEMPLATE WILL ASSIST IN ACCURATELY PLACING THE ANCHOR BOLTS.
FIELD VERIFICATION PRIOR TO CONCRETE PLACEMENT:
1. IMMEDIATELY PRIOR TO CONCRETE PLACEMENT, THE ANCHOR BOLT LOCATIONS, PROJECTIONS, AND DIAMETERS
SHALL BE FIELD VERIFIED TO MATCH THE ANCHOR BOLT HOLE LOCATION IN THE MOUNTING PLATE. IN THE EVENT THAT THE BASEPLATE IS NOT AT THE SITE, THE ANCHOR BOLTS' LOCATION SHALL BE VERIFIED AGAINST THE STRUCTURAL FOUNDATION DRAWINGS AND THE MANUFACTURER'S DRAWINGS. THE ANCHOR BOLTS SHALL ALSO BE EXAMINED TO VERIFY THAT THEY HAVE BEEN INSTALLED PLUMB, HAVE THE CORRECT LENGTH AND PROJECTION, ARE ADEQUATELY SECURED TO PREVENT DISPLACEMENT DURING THE CONCRETE PLACEMENT, AND THE THREADS ARE NOT STRIPPED OR DAMAGED. ALL NECESSARY PROCEDURES SHALL BE TAKEN TO CORRECT ANY DISCREPANCIES OR DEFICIENCIES BEFORE CONCRETE OPERATIONS SHALL BE PERMITTED TO BEGIN.
2. ALL ANCHOR BOLT SLEEVES SHALL BE COVERED OR FILLED WITH A NONBONDING MOLDABLE MATERIAL TO
PREVENT ENTRY OF CONCRETE.
3. PRIOR TO CONCRETE PLACEMENT, THE PROPOSED ELEVATION OF THE TOP OF THE FOUNDATION CONCRETE SHALL BE VERIFIED WITH THE ELEVATION SPECIFIED ON THE FOUNDATION DRAWING, AND THE NECESSARY PROCEDURES
SHALL BE TAKEN TO CORRECT ANY DISCREPANCIES.
GENERAL FOUNDATION NOTES
CONCRETE MIXING AND PLACEMENT PROCEDURES:
1. CONCRETE MATERIALS, FORMWORK, HANDLING, MIXING, AND PLACEMENT SHALL CONFORM TO ACI 301.
2. MATERIALS, MIXING, HANDLING, AND PLACEMENT OF MASS CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301.
ADEQUATE CONTROL OF THE CONCRETE TEMPERATURE SHALL BE MAINTAINED AT THE POUR POINT.
3. UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS, AT THE POINT OF DELIVERY, CONCRETE SHALL HAVE MAXIMUM SLUMP OF 4 INCHES WHEN ACHIEVED BY WATER ALONE. IF A SLUMP GREATER THAN 4 INCHES IS REQUIRED FOR PROPER PLACEMENT OF CONCRETE, IT MAY BE INCREASED UP TO 8 INCHES USING AN APPROVED HIGH-RANGE
WATER-REDUCING AGENT.
4. THE FIELD ADDITION OF WATER TO INCREASE THE SLUMP SHALL NOT BE PERMITTED WITHOUT APPROVAL OF THE
USER.
5. FOUNDATIONS SHALL BE MADE IN ONE CONTINUOUS POUR UNLESS OTHERWISE APPROVED BY THE USER OR
SHOWN ON THE DRAWINGS.
6. IMMEDIATELY AFTER PLACEMENT, CONCRETE SHALL BE PROTECTED FROM COLD OR HOT WEATHER EXTREMES, MECHANICAL INJURY, AND PREMATURE DRYING AND SHALL BE CURED AS SPECIFIED IN ACI 301.
7. UNLESS OTHERWISE APPROVED BY THE USER, THE FOUNDATION PREPARATION PROCEDURES FOR GROUTING SPECIFIED IN THE GROUTING SECTION OF THIS SPECIFICATION OR THE SETTING OF ANY EQUIPMENT ON THE FOUNDATION SHALL NOT BE PERMITTED TO BEGIN UNTIL CONCRETE CURING IN ACCORDANCE WITH ACI 301 HAS BEEN COMPLETED, AND THE CONCRETE HAS ATTAINED THE SPECIFIED 28-DAY COMPRESSIVE STRENGTH AS
DEFINED IN ACI 301.
8. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 POUNDS PER SQUARE INCH AT 28 DAYS, UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS.
9. HIGH EARLY STRENGTH CONCRETE SHALL BE USED ONLY WITH THE APPROVAL OF THE EQUIPMENT USER AND
ENGINEER.
CONCRETE QUALITY CONTROL:
1. THE OWNER RESERVES THE RIGHT TO SUBJECT THE CONCRETE FOUNDATION CONSTRUCTION TO INSPECTION BY
AN ACI-CERTIFIED INSPECTOR OR ANY OWNER-DESIGNATED TESTING AGENCY. TESTS OF CONCRETE COMPRESSIVE STRENGTH, AIR CONTENT, AND SLUMP SHALL BE AS DESIGNATED BY THE OWNER OR IN
ACCORDANCE WITH ACI 301.
SCALE 1/2" = 1'-0"
FOUNDATION PLAN
SCALE 1/2" = 1'-0"
DOUBLE POST FOUNDATION DETAIL
SCALE 1/2" = 1'-0"
SINGLE POST FOUNDATION DETAIL
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
SIDE ELEVATION
SCALE 1/4" = 1'-0"
PLAN VIEW
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
SIDE ELEVATION
SCALE 1/4" = 1'-0"
PLAN VIEW
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SIGN TYPE UX-i31
SS104 SCALE: AS NOTED
SIGN TYPE HX-i12
SS104 SCALE: AS NOTED
SIGN TYPE HX-W23
SS104 SCALE: AS NOTED
FINAL CONSTRUCTION DOCUMENTS
3919 Saw Mill Run Boulevard, Pittsburgh, PA 15227 | wfpros.com
The Gateway Engineers, Inc.
Pittsburgh, PA
Earl Swensson Associates, Inc.
Nashville, TN
Stewart C. Cluck, Architect, LLC York, PA
STRUCTURAL PLANS,
DETAILS & NOTES
VAPHS HEINZ, PITTSBURGH, PA
646-13-105
SITE
SS104
7 643-29-2018 BDS
MASTER WAYFINDING FOR VAPHS
STRUCTURAL STEEL NOTES
1. STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (FOURTEENTH EDITION) AND THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS
AND BRIDGES".
2. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:
A.CHANNELS, ANGLES, PLATES AND MISCELLANEOUS CONNECTION MATERIAL- ASTM A36 WITH A MINIMUM
YIELD STRENGTH OF 36 KSI, U.N.O.
B.STEEL TUBE- ASTM A500, GRADE B, WITH A MINIMUM YIELD STENGTH OF 46 KSI.
3. BOLTS SHALL BE 3/4" DIAMETER ASTM A325 H.S. U.N.O. CONNECTIONS SHALL BE TYPE N FOR FRAMED
CONNECTIONS AND TYPE SC CLASS A FOR WIND MOMENT.
4. WELDING SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL WELDING CODE ANSI/AWS D1.1", AMERICAL
WELDING SOCIETY, LATEST EDITION. USE E70XX ELECTRODES.
5. FIELD WELDED SURFACES SHALL BE CLEANED, GROUND SMOOTH, AND COATED WITH APPROPRIATE
PRIMER/PAINT AS SPECIFIED.
6. STEEL IN EXTERIOR ELEMENTS OR EMBEDDED IN EXTERIOR WALL OR CAVITY SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM A-123. WHEN GALVANIZED STEEL IS FIELD WELDED, PROVIDE APPROPRIATE VENTILATION MEASURES. WELDED SURFACES SHALL BE GROUND SMOOTH AND COATED WITH
GALVANIZING REPAIR PAINT.
7. STRUCTURAL STEEL FABRICATOR SHALL PROVIDE FOR VERTICAL AND HORIZONTAL FIELD ADJUSTMENTS OF
SUPPORT ASSEMBLIES.
8. CUTS, HOLES, COPING, ETC. REQUIRED FOR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND
MADE IN THE SHOP. CUTS OR BURNING HOLES IN THE FIELD WILL NOT BE PERMITTED.
8'-6"
12'-21 4"
9'-0"
3'-6" 2'-101 2"
C12x20.7
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
FIN. GRADE
8'-01 4"
1'-0"
12'-21 4"
3'-6" 2'-101 2"
4'-0"
1'-11 4"
C12x20.7
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
#4 HORIZ. BARS
@ 12" O.C.
#6 VERT. BARS @
12" O.C. W/ 24" LEG
(5) #5 BARS EQ.
SPACED T&B
8'-01 4"
9'-0"
1'-13 4"4'-0"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
C12x20.7
8'-5-1/2" X 1'-0" X
1" THICK STEEL
PLATE
1'-0"
8'-51 2"
1/4 TYP.
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
(12) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • •
BOLTS (EMBED. 6" MIN.)
1'-13 4"
2" MIN.
0'-41 2"
0'-6" 1'-4" 1'-4" 1'-63 4" 1'-4" 1'-4" 0'-6"
4'-81 2"
3'-4"
2'-103 4"
3'-6"
4'-0"
2'-101 2"
3'-6"
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
C8X11.5
2'-8"
FIN. GRADE
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
BRICK
(BY OTHERS)
#4 TIES @
12" O.C.
(3) #5 BARS EQ.
SPACED T&B
#5 VERT. BARS @
12" O.C. W/ 12" LEG
#4 HORIZ. BARS
@ 12" O.C.
3/4" THICK PLATE
2'-0"
2'-101 2"
0'-91 4"
0'-8"
4'-81 2"
3'-6"
C8X11.5
2'-8"
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
(3) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 12" LEG
0'-0"
0'-0"
4'-0"
2'-0"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
C8X11.5
3'-4" X 0'-8" X 34"
THICK STEEL
PLATE
0'-8"
1/4
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
0'-93 4"
0'-8" 1'-0" 1'-0" 0'-8"
(3) 5 8•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
8•• •• • • • •• • • • • •• • • •• • • •• • • • • • •
BOLTS (EMBED. 6" MIN.)
2" MIN.
3'-4"
TYP.
3'-9"
3'-4"
2'-103 4"
3'-6"
4'-0"
2'-101 2"
3'-6"
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
C12X20.7
FIN. GRADE
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
BRICK
(BY OTHERS)
#4 TIES @
12" O.C.
(3) #5 BARS EQ.
SPACED T&B
#5 VERT. BARS @
12" O.C. W/ 12" LEG
#4 HORIZ. BARS
@ 12" O.C.
3/4" THICK PLATE
2'-0"
2'-101 2"
1'-11 4"
1'-0"
3'-9"
3'-6"
C12X20.7
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
(3) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 12" LEG
2'-103 4"
1'-13 4"
4'-0"
2'-0"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
C12X20.7
3'-4" X 1'-0" X 34"
THICK STEEL
PLATE
1'-0"
1/4
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
1'-13 4"
0'-6" 1'-103 4" 0'-6"
(4) 5 8•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
8•• •• • • • •• • • • • •• • • •• • • •• • • • • • •
BOLTS (EMBED. 6" MIN.)
2" MIN.
3'-4"
TYP.
0'-41 2"
8'-6"
5'-91 4"
9'-0"
3'-6" 2'-101 2"
C12X20.7
INFILL BETWEEN CHANNELS
W/ COLD-FORMED STEEL
(BY OTHERS)
6" MIN. AASHTO
#57 STONE
COMPACTED SUBGRADE;
FREE OF CLAYS AND
ORGANICS
#4 TIES @
12" O.C.
(5) #5 BARS EQ.
SPACED T&B
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 24" LEG
FIN. GRADE
8'-01 4"
1'-0"
5'-91 4"
3'-6" 2'-101 2"
2'-6"
1'-11 4"
C12X20.7
2"D X 4"W
KEYWAY
#4 TIES @
12" O.C.
#4 HORIZ. BARS
@ 12" O.C.
#5 VERT. BARS @
12" O.C. W/ 12" LEG
(3) #5 BARS EQ.
SPACED T&B
8'-01 4"
9'-0"
1'-13 4"2'-6"
CONCRETE
STEM WALL
CONCRETE
FOOTING
BRICK
(BY OTHERS)
C12X20.7
8'-5-1/2" X 1'-0" X
1" THICK STEEL
PLATE
1'-0"
8'-51 2"
1/4 TYP.
CONCRETE
STEM WALL
BRICK (BY
OTHERS)
(12) 3 4•• •• •• • ••• •• •• • • • • • • • • • • • • • •
POST-INSTALLED ANCHORS
W/ HIT-HY 200 ADHESIVE OR
4•• •• • • • •• • • • • •• • • •• • • •• • • • • • • • • • • • • • • • • • • • •
BOLTS (EMBED. 6" MIN.)
1'-13 4"
0'-6" 1'-4" 1'-4" 1'-63 4" 1'-4" 1'-4" 0'-6"
2" MIN.
0'-41 2"
3919 Saw Mill Run Boulevard, Pittsburgh, PA 15227 | wfpros.com
The Gateway Engineers, Inc.
Pittsburgh, PA
Earl Swensson Associates, Inc.
Nashville, TN
Stewart C. Cluck, Architect, LLC York, PA
STRUCTURAL PLANS,
DETAILS & NOTES
VAPHS HEINZ, PITTSBURGH, PA
646-13-105
SITE
SS105
8 643-29-2018 BDS
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
SIDE ELEVATION
SCALE 1/4" = 1'-0"
PLAN VIEW
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SCALE 1/2" = 1'-0"
FACE A ELEVATION
SCALE 1/2" = 1'-0"
SIDE ELEVATION
SCALE 1/2" = 1'-0"
PLAN VIEW
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SCALE 1/2" = 1'-0"
FACE A ELEVATION
SCALE 1/2" = 1'-0"
SIDE ELEVATION
SCALE 1/2" = 1'-0"
PLAN VIEW
SCALE 1" = 1'-0"
BASE PLATE DETAIL
SCALE 1/4" = 1'-0"
FACE A ELEVATION
SCALE 1/4" = 1'-0"
SIDE ELEVATION
SCALE 1/4" = 1'-0"
PLAN VIEW
SCALE 1" = 1'-0"
BASE PLATE DETAIL
MASTER WAYFINDING FOR VAPHS
SIGN TYPE HX-W31
SS105 SCALE: AS NOTED
SIGN TYPE HX-M13
SS105 SCALE: AS NOTED
SIGN TYPE HX-W14
SS105 SCALE: AS NOTED
SIGN TYPE HX-i32
SS105 SCALE: AS NOTED
FINAL CONSTRUCTION DOCUMENTS
File details come from the government source that posted it.